Using a long-term chloride wet-dry cycling test method,the effects of different steel fiber volume fractions on the chloride ion transport properties of UHPC were investigated.The time-dependent variation of the apparent chloride diffusion coefficient and surface chloride concentration was analyzed.Results indicate that:(1)after 180 days of wet-dry cycles,a convection zone develops at a depth of 2 mm in UHPC,with the internal chloride ion concentration distribution following Fick's second law;(2)the addition of steel fibers does not alter the formation of the convection zone,while in the early stages of erosion,the apparent diffusion coefficient of UHPC increases with higher steel fiber volume fractions but gradually decreases with time;(3)the surface chloride concentration stabilizes over time,conforming to an exponential model.
随着我国城镇化进入新格局,乡村聚落进入不平衡收缩过程.村庄居民点布局规划是对农村人居环境发展与建设的重要引导依据.本文以道萨迪亚斯的"人类聚居学"理论为基础,通过GIS空间分析与数据量化的统计制定从镇域层面出发的整体协调发展策略,提出宏观层面城乡关系、中观层面镇域空间到微观层面人居环境的整体协调发展的规划策略,将其视为一个整体对象进行考虑,制定精准规划促进农村人居环境建设的可持续发展.
本文结合某地下管廊工程案例,概述了利用电渗透技术解决管廊隧道渗水的问题,介绍了电渗透抗渗系统的设计、施工及验收过程.讨论了电渗透系统抗渗效果的验证方式,为电渗透系统相关工程提供参考.
以粉煤灰掺量和水玻璃模数为主要参数,进行了地聚合物混凝土净浆和胶砂试验,确定了最优模数和液固比.结果表明:水玻璃模数取1.4,液固比为0.65,胶砂比为1∶1.6时,粉煤灰地聚合物混凝土的流动性和抗折抗压强度相对较好.
为实现隔震技术在高层建筑结构中的应用,本文结合相关规范及规程提出一套高层隔震结构简洁清晰的设计步骤,并按此步骤对云南龙陵某高层商住楼进行隔震设计和分析,时程分析表明:在基本周期方面,隔震结构的周期比抗震结构的周期延长了许多;在基本地震作用下,本文采用的是8度(0.3g),通过计算得到的结构X、Y方向的减震系数分别达到0.36和0.37,层间位移的减震比在X、Y方向分别为0.26和0.37,加速度在X、Y方向的减震比分别为12.2%和8.4%,结构的地震作用效应大幅降低,隔震层的支座应力、位移、弹性恢复力及风荷载下的稳定性等验算均满足要求,充分地验证了本文提出的设计步骤的可行性,且进一步验证了高层隔震结构的减震效果,最终,使得该工程在确保合理设计的同时,可以获得良好的社会经济效益,并为工程技术人员将隔震技术应用到高层结构提供了有益的借鉴.