
Abstract This paper proposes an image super-resolution restoration algorithm based on example learning and iterative directional kernel regression, which is used to solve the problem that the existing super-resolution restoration algorithm based on example learning cannot effect the restored image has a small degree of matching with the sample library and the problem of image restoration in the presence of noise. Among them, the example learning can achieve basic image restoration. In the directional kernel regression, the estimated smoothing matrix can obtain the minimum mean square estimation after multiple iterations, and further optimize the super-resolution restored image. Simulation results show that the improved algorithm improves the robustness and edge preservation characteristics of the super-resolution restoration image. Compared with the classical algorithm, the algorithm has better visual effects and the root mean square error can be improved over 15%, and reflect the effectiveness of the algorithm.
目的 分析乳腺影像报告与数据系统(BI-RADS)联合超声弹性成像(UE)技术对小乳腺癌的诊断价值.方法 以我院乳腺科2018年1月~2020年2月收治的274例乳腺肿块患者为研究对象,所有患者均进行病理检查,根据病理检查结果分为乳腺增生患者(165例)和小乳腺癌(109例)患者,比较乳腺增生患者和小乳腺癌患者BI-RADS和UE评分;根据病理结果,比较UE、BI-RADS单独检查和联合检查对小乳腺癌的检出情况,并分析UE、BI-RADS单独检查和联合检查对小乳腺癌的诊断价值.结果 经病理检查结果显示,本研究纳入的274例乳腺肿块患者中乳腺增生患者占比为60.22%,小乳腺癌患者占比为39.78%.小乳腺癌患者UE、BI-RADS评分均显著高于乳腺增生患者(P<0.05).UE、BI-RADS联合检查对小乳腺癌的检出率为91.74%,显著高于UE(76.15%)和BI-RADS(79.90%,P<0.05).UE、BI-RADS联合检查诊断小乳腺癌的灵敏度(91.74%)、特异度(95.15%)、阳性预测值(92.59%)、阴性预测值(94.58%)和准确度(93.80%)均高于UE和BI-RADS单独检查(76.15%、78.18%、69.75%、83.23%、77.37%和78.90%、81.82%、74.14%、85.44%、80.66%,P<0.05).结论 小乳腺癌患者UE、BI-RADS评分均显著高于乳腺增生患者,BI-RADS联合UE技术对小乳腺癌的检出率高于两者单独检查,同时其对小乳腺癌的诊断价值高于两者单独检查,因此临床可联合两者对乳腺肿块患者进行检查,提高小乳腺癌的检出率,进而及时治疗以改善患者预后.
通过对真实人物动作特征的抓取和分析,可以提高三维虚拟人物动作的仿真度和识别度,为此提出了一种基于三维虚拟动态成像的动作捕捉技术.通过立体空间立体扫描识别技术对真实人物的动作进行动态图像的特征抓取,基于AR虚拟现实技术对所获取动态图像的轮廓进行分割,将所有动态特征体现在直方图中,同时引入harris角点检测扫描技术捕捉真实人物的体操动作,以此来构建动态三维虚拟动作图像.实验结果显示,所提出的方法能够在捕捉图像中实现动态特征的高度匹配,具有较强的识别能力和虚拟图像构建能力.
目的:分析99mTC-MDP骨扫描联合PET CT检测肺癌骨转移价值的临床方回顾性分析2018年2月至2020年8月在我院就诊的肺癌骨患者120例的临床资料,其中58例患者行PET CT检查作为对照组,62例患者行99mTC-MDP骨扫描联合PET-CT作为观察组,比较两组的准确率、特异性、灵敏度、PPV(阳性预测值)、NPV(阴性预测值、准确性及骨转移灶和不同部位病灶的检出率.结果:两者联合检测的准确率、特异性、灵敏度、PPV(阳性预测值)、NPV(阴性预测值、准确性均高于PET-CT单独检测(P<0.05),观察组对骨转移灶的检出率总检出率高于对照组(P<0.05),见表3.对颈椎、胸椎、腰椎、骶椎、骨盆、肋骨、胸骨、胸骨、锁骨、肩胛骨、股骨、肱骨、颅骨等不同部位结果观察组检出数高于对照组,但是两组差异不显著(P>0.05).结论:99mTC-MDP骨扫描联合PET-CT检测肺癌骨转移具有良好的准确率、特异性、灵敏度,骨转移灶的检出率高于PET-CT单独检测,具有良好的临床应用价值.
目的 分析在达芬奇机器人器械消毒灭菌管理工作中的质量管理作用效果.方法 选取2018年1月至7月期间的75件达芬奇机器人器械作为对照组,另选取2018年8月至2019年12月期间的75件达芬奇机器人器械作为实验组.对照组采取常规消毒、灭菌处理,实验组在此基础上采取质量管理措施.对比两组达芬奇机器人的返洗器械率.结果 实验组返洗器械率(1.05%)相较对照组(6.67%)明显更低,两组对比有统计学差异(P<0.05),实验组各项器械消毒质量均明显高于对照组.结论 质量管理应用于达芬奇机器人器械消毒灭菌管理工作中,能够减少返洗器械率,提高消毒供应室工作质量,确保达芬奇机器人正常运行.