Objective:To evaluate the usability of Gafchromic HD-V2 film for dose dosimetry in the ultra-high dose-rate (UD) electron beam from a modified medical linac, and to investigate the response between the energy and dose-rate dependence to the film.Methods:The HD-V2 film was utilized to measure the average dose-rate of the UD electron beam. The measured result was compared with those by advanced Markus chamber and alanine pellets. And characteristics of the UD electron beam were also measured by HD-V2 film. Energy dependence of HD-V2 film at three beam energies (6 MV X-ray, 9 MeV and 16 MeV electron beam) was investigated by obtaining and comparing the calibration curves based on the clinical linear accelerator in the dose range of 10-300 Gy. The dose-rate dependence of HD-V2 film was also studied by varying the dose rate among 0.03 Gy/s, 0.06 Gy/s and 0.1 Gy/s, and range of 100-200 Gy/s.Results:The measured average maximum dose-rate of 9 MeV UD electron beam at source skin distance (SSD) 100 cm was approximately 121 Gy/s using HD-V2 film, consistent with the results by advanced Markus chamber and alanine pellets. The measured percentage depth dose (PDD) curve parameters of the UD electron beam were similar to the conventional 9 MeV beam. The off-axis dose distribution of the UD electron beam showed the highest central axis, and the dose was gradually decreased with the increase of off-axis distance. The energy dependence of HD-V2 film had no dependency of 6 MV and 9, 16 MeV while measuring the dose in the range from 20 to 300 Gy. The HD-V2 film had no significant dose-rate dependency at the dose rate of 0.03 Gy/s, 0.06 Gy/s and 0.1 Gy/s for the clinical linear accelerator. Likewise, there was also no dose-rate dependence in the range 100-200 Gy/s in the modified machine.Conclusion:HD-V2 film is suitable for measuring ultra-high dose rate electron beam, independent of energy and dose rate.
Objective:To investigate the feasibility of transforming conventional medical accelerator to achieve ultra-high dose rate required to achieve Flash radiotherapy (Flash-RT), and to understand the physical properties of the Flash-RT beam.Methods:By transforming the Varian 23CX medical accelerator, the radiation average dose rate at the isocenter was not less than 40 Gy/s. The relevant physical measurement scheme was designed to accurately measure the actual radiation dose rate of different source skin distance (SSD) conditions, the percent depth dose (PDD) curve and the off-axis dose distribution of the beam.Results:The average dose rate of 9 MeV electron beam after the transformation was measured using the HD-V2 type film, the average dose rate of 3 s was 97.9 Gy/s, and the average dose rate of 6 s was 99.27 Gy/s. When the SSD was 100 cm, 80 cm and 60 cm, the average dose rate of 9 MeV electron beam after the transformation was 99.3 Gy/s, 168 Gy/s and 297.5 Gy/s, respectively. After the transformation, the R100 of the 9 MeV beam was 2.2 cm underwater, R50 was 3.87 cm underwater, the electron range Rp was 4.58 cm, and the maximum possible energy Ep,0 on the phantom surface was 9.28 MeV. These parameters were slightly higher than those of the conventional 9 MeV beam, manifested with slight increase in the surface dose and widening high dose flat area. The overall deposit dose distribution exhibited the highest central axis and the increase in dose declines from the axis distance. Under the condition that the field size was 20 cm×20 cm and the SSD was 100 cm, the FWHM of the vertical and horizontal off-axis dose distribution curves were 16.6 cm and 16.4 cm, respectively. Conclusion:By transforming conventional medical accelerator, the average dose rate of the beam at the isocycle meets the requirement of Flash-RT, and the average dose rate under the condition of 60 cm SSD is much higher than the requirement of at least 40 Gy/s for Flash-RT.
Objective:To propose an automatic planning platform of the Raystation planning system suitable for multi-disease and multi-plan technique by using the Raystation built-in script function.Methods:IronPython and WPF user interface framework were utilized for programming and resolving the differences in the design of different types of plans for different diseases. The program was designed from prescription identification, visual plan parameter input and cost-function setting. The efficiency of automatic planning and manual planning was compared when applied in whole brain irradiation, nasopharyngeal carcinoma, cervical cancer, esophageal cancer and breast cancer, including IMRT and VMAT. The dosimetric parameters of the whole brain irradiation were chosen.Results:Physicists were only required to enter and select the necessary parameters to achieve the plan design by using the program. Compared with the five types of diseases, the maximum efficiency of automatic planning was 1.4 times higher than that of manual planning. In the dosimetric evaluation of the whole brain irradiation plan, both manual and automatic planning could meet the clinical needs, and the D 2%, CI and HI of the target area did not significantly differ (all P>0.05). The mean D 98% of the target area and the D max of lens in the manual plan were significantly higher than those in the automatic plan by 0.4% and 7.1%(both P<0.05). Conclusion:The developed program has the function of automatic planning system, which can realize the automatic planning of multi-disease and multi-type radiotherapy, significantly improve the efficiency of plan design and has important clinical application value.
Based on the traditional metal-dielectric-metal fishnet metamaterial,two new metamaterials were designed,each comprising four parallel or alternately arranged structural units of different permittivity of dielectric spacers as the unit cell.The left-handed properties for both fishnet structues were numerically investigated.The fishnet structure with two kinds of structural unit enabled different units to be excited at their corresponding frequencies compared with that of using single dielectric spacer,consequently resulting in dual left-handed bands.The behaviors of negative refractive index in both fishnet metamaterials were further validated by simulations of a wedge-shaped model and the backward wave propagation.One or more negative refraction bands in the fishnet metamaterials with two kinds of structural unit can be obtained by adjusting the permittivity of the spacer,which provided a feasible method for fabricating multi-band filters and variable-frequency microwave devices with better performances.
A novel dielectric-general dielectric-high plate structure is designed by using dielectric materials.For all dielectric structures,the displacement current induced by the incident electromagnetic wave can replace the conduction current in metal structure and excite specific resonance mode to result in negative index of refraction.The extracted effective medium parameters and the simulation of wedge-shaped prism confirm the left-hand property in all dielectric structures.The dependence of left-handed transmission band on the geometrical parameter of the high dielectric plate is also investigated.Using the high-dielectric material to build left-handed materials can overcome the limitations of structural complexity and high losses in metal-based left-handed materials,consequently providing a new design idea for high-frequency and low-loss electromagnetic metamaterials.
Tunablility of negative-refraction in metal-rod pair metamaterial by liquid crystals is demonstrated by numerical simulation.It is shown that negative index can be achieved in the frequency range from 0.648 THz to 0.413 THz,covering two atmospheric windows around 0.65 THz and 0.50 THz,by tuning the permittivity of liquid crystals from 2 to 4.Negative,zero or positive index can be obtained at any frequency within the negative refraction range by changing the permittivity of liquid crystals.Since the permittivity of liquid crystals can be tuned by an external bias or a light field,the frequency of negative refraction and the propagating direction of a THz wave can be well controlled.