В работе рассматривается влияние чистого и модифицированного сверхкритического диоксида углерода на полиэтилен 5118 с целью определения возможности использования сверхкритических флюидовв качестве стерилизующего агента медицинских изделий из полимерных материалов. Представлено аппаратурное оформление и методика проведения эксперимента по изучению адсорбции полиэтиленом сверхкритического СО2. Выявлено отсутствие растворимости испытуемого полимерного материала в стерилизанте.
The authors consider the possibility of the use of supercritical fluids as sterilizing agents for medical devices. They conducted studies on the inactivation of Bacillus atrophaeus with pure and modified supercritical carbon dioxide. It has been found that under certain thermodynamic parameters, modified CO2 is an effective sterilizing agent against Bacillus atrophaeus spores. The duration of achieving complete inactivation is also determined.
Стерилизация медицинских изделий является одной из актуальных проблем в современной медицине.Разнообразие медицинского инструментария, наличие деталей в их конструкции из полимерных и других материалов, труднодоступность отдельных узлов для обработки, создают определённые сложности при стерилизации, а также в выборе оптимального метода в каждом конкретном случае.Принимая во внимание, что в России за последнее десятилетие наблюдается динамичный рост объемов производства одноразовых полимерных изделий медицинского назначения, то в данный момент это увеличение приближается к своему пределу по причине нехватки мощности стерилизационных центров в целом по стране и их полное отсутствие во многих регионах, в том числе, в Поволжье.В частности, с 2015 по 2018 год внутреннее производство медицинских изделий выросло более чем на 15% [1].Например, на предприятиях Республики Татарстан производится более 3000 наименований медицинских инструментов, в том числе: стоматологический инструментарий (твердосплавные боры и фрезы
The thermal conductivity of binary ammonia + water mixtures was measured over the temperature range from 278 K to 356 K and at pressures to 20 MPa using the steady-state hot-wire method. Measurements were made for ten compositions over the entire concentration range from 0 to 1 mole fraction of ammonia, namely, 0.0, 0.1905, 0.2683, 0.3002, 0.4990, 0.5030, 0.6704, 0.7832, 0.9178, and 1.0 mole fraction of ammonia. In total, 316 experimental data points were obtained. The expanded uncertainty, with a coverage factor of k = 2, of the thermal conductivity, pressure, temperature, and concentration measurements is estimated to be 3%, 0.05%, 0.02 K, and 0.0014%, respectively. The average absolute deviation (AAD) between the measured and calculated reference values for pure water and ammonia is 1.3% and 1.4%, respectively. Correlation models for the thermal conductivity of liquid ammonia + water mixtures were also developed. (C) 2013 Elsevier Ltd and IIR. All rights reserved.
Synthesis of methyl and ethyl esters of fatty acids via transesterification of vegetable oils in supercritical methanol and ethanol is carried out on a pilot installation with a continuous flow reactor. The corresponding procedures are described, and the results are analyzed. The effect of preliminary ultrasonic treatment of the initial mixture on the product yield is studied, and the correlation between the stability of the obtained emulsions and the composition of the initial mixture, as well as the intensity of the ultrasonic treatment, are determined. The isobaric heat capacity of the supercritical alcohol (methanol, ethanol) — vegetable oil mixtures is measured.
The influence of the pretreatment procedures with supercritical CO 2 (SC-CO 2 ) on the elemental composition of tealeaf is studied. Fourier-transform infrared absorption spectroscopy is used to examine the effect of SC-CO 2 on the structure of Chinese green tea and cellulose.
In the thermally conducting calorimeter measured values of the coefficient of thermal expansion, isobaric heat capacity, thermal diffusivity of oleic acid in the temperature range 298 363K and pressures of 0.098 147MPa. In this article was comparison of the experimental data with the literature and with results of the calculation. The generalized dependences for determination of a thermal capacity and thermal diffusivity are offered