SERRS (surface-enhanced resonance Raman scattering) is a vibrational spectroscopy which allows extremely sensitive and selective detection of labelled DNA sequences with detection limits which rival, and in most cases surpass, that of fluorescence. SERRS relies on a visible chromophore adsorbing on to an enhancing surface. DNA itself is not SERRS-active, as it lacks a suitable visible chromophore and has poor adsorption properties on to the surfaces used for enhancement. The surface normally used for enhancement in these sorts of studies are metallic nanoparticles and, through modification of DNA probes by the addition of suitable SERRS labels, signals can be obtained that are highly sensitive and very selective. The aggregation state of the nanoparticles is critical to the sensitivity, and, in the present paper, we show how straightforward detection of labelled DNA probes can be achieved using SERRS in a quantitative manner and with a variety of different commercially available labels. In a second approach, we show how the properties of aggregation to turn on the SERRS effect can be exploited through DNA hybridization to give identification of a particular DNA sequence. This approach lends itself to closed-tube formats and is a promising way forward for molecular diagnostics using SERRS.
Detection of specific DNA sequences is central to modern molecular biology and also to molecular diagnostics where identification of a particular disease is based on nucleic acid identification. Many methods exist, and fluorescence spectroscopy dominates the detection technologies employed with different assay formats. This study demonstrates the use of surface-enhanced resonance Raman scattering (SERRS) to detect specific DNA sequences when coupled with modified SERRS-active probes that have been designed to modify the affinity of double- and single-stranded DNA for the surface of silver nanoparticles resulting in discernible differences in the SERRS which can be correlated to the specific DNA hybridization event. The principle of the assay lies on the lack of affinity of double-stranded DNA for silver nanoparticle surfaces; therefore, hybridization of the probe to the target results in a reduction in the SERRS signal. Use of locked nucleic acid (LNA) residues in the DNA probes resulted in greater discrimination between exact match and mismatches when used in comparison to unmodified labeled DNA probes. Polymerase chain reaction (PCR) products were detected using this methodology, and ultimately a multiplex detection of sequences relating to a hospital-acquired infection, namely, methicillin-resistant Staphylococcus aureus (MRSA), demonstrated the versatility and applicability of this approach to real-life situations.
The evaluation of phthalocyanine labels for the surface-enhanced resonance Raman scattering (SERRS) detection of oligonucleotides is reported. Three phthalocyanine-labelled oligonucleotides were assessed, each containing a different metal centre. Detection limits for each labelled oligonucleotide were determined using two excitation frequencies where possible. Limits of detection as low as 2.8 x 10(-11) mol. dm(-3) were obtained which are comparable to standard fluorescently labelled probes used in previous SERRS studies. The identification of two phthalocyanine-labelled oligonucleotides without separation was also demonstrated indicating their suitability for multiplexing. This study extends the range of labels suitable for quantitative surface-enhanced resonance Raman scattering with silver nanoparticles and offers more flexibility and choice when considering SERRS for quantitative DNA detection.
Surface-enhanced resonance Raman scattering (SERRS) from silver nanoparticles using 514.5-nm excitation has been shown to offer huge potential for applications in highly sensitive multiplexed DNA assays. If the technique is to be applied to real biological samples and integrated with other methods, then the use of gold nanoparticles and longer wavelengths of excitation are desirable. The data presented here demonstrate that dye-labeled oligonucleotide sequences can be directly detected by SERRS using gold nanoparticles in a quantitative manner for the first time. The performance of gold and silver nanoparticles as SERRS substrates was assessed using 514.5-, 632.8-, and 785-nm excitation and a range of 13 commercially available dye-labeled oligonucleotides. The quantitative response allowed the limit of detection to be determined for each case and demonstrates that the technique is highly effective, sensitive, and versatile. The possibility of excitation at multiple wavelengths further enhances the multiplexing potential of the technique. The importance of effectively combining the optical properties of the nanoparticle and the dye label is demonstrated. For example, at 632.8-nm excitation, the dye BODIPY TR-X and gold nanoparticles make a strong SERRS combination with very little background fluorescence. This study allows the choice of nanoparticle and dye label for particular experimental setups, and significantly expands the applicability of enhanced Raman scattering for use in many disciplines.
Careful control of surface chemistry results in strong surface enhanced resonance Raman scattering from dye-labelled oligonucleotides assembled on nanostructured gold surfaces, releasing their potential as reliable enhancing surfaces.
A two-temperature continuous-flow polymerase chain reaction (PCR) polymer chip has been constructed that takes advantage of droplet technology to avoid sample contamination and adsorption at the surface. Samples contained in aqueous droplets are continuously moved by an oil carrier-fluid through various temperature zones, introducing the possibility of real-time quantitative PCR. In the present paper, we investigate many of the factors affecting droplet-based PCR chip design, including thermal mass, flow rate, and thermal resistance. The study focuses particularly on the fluid and substrate temperature distribution within the PCR chip and the droplet residence times in critical temperature zones. The simulations demonstrate that the flow rate strongly affects the temperature field within the carrier-fluid. Above a critical flow rate, the carrier-fluid fails to achieve the required temperatures for DNA amplification. In addition, the thermal resistances of the different layers in the chip are shown to have a major impact on the temperature profile in the channel.
A new approach to the synthesis of polymer beads that give surface-enhanced resonance Raman scattering (SERRS) is reported. Controlling the aggregation of silver nanoparticles by silica seeding prior to encapsulation into a polymer is shown to yield a highly reproducible bead with a relative standard deviation (RSD) diameter down to 5%. The reliable and intense SERRS response is attributed to the combined resonance of the reporter dye (435 nm) and the nanoparticle cluster ( 440 nm). The presence of heavier clustered particles within the bead core means the activity can be further improved to around 93% by means of sedimentation purification. This is a significant step towards a reproducible and reliable reporter unit for the many varied potential biodiagnostic applications of SERRS.
A two-temperature continuous-flow PCR polymer chip has been constructed that takes advantage of droplet technology to avoid sample contamination and adsorption at the surface. Samples contained in aqueous droplets are continuously moved by an oil carrier-fluid through various temperature zones, introducing the possibility of real-time quantitative PCR. The use of droplet technology also makes it possible to perform high throughput analyses of single cells allowing the study of populations of cells and facilitating a more comprehensive understanding of biological variance with relation to disease. In the present device, the thermal cycling time is significantly reduced and the PCR samples are exposed to more uniform temperatures. This paper investigates many of the factors affecting droplet-based PCR chip design, including specific heat capacity, density, flow rate, and thermal resistance. The study focuses particularly on the fluid and substrate temperature distribution within the PCR chip and the droplet residence times in critical temperature zones. The results show that, in general, the carrier-fluid should have a low thermal mass to ensure minimal heating and cooling times. It was found that the predicted temperature distribution in the chip arises from a subtle thermal interaction between the substrate and the carrier-fluid. The simulations demonstrate that the flow rate strongly affects the carrier-fluid’s temperature field. Above a critical flow rate, the carrier-fluid fails to achieve the temperatures required for DNA amplification. Moreover, the thermal resistance of the different layers is shown to have a major impact on the temperature profile in the channel.
In this study, uniform spherical molecularly imprinted polymer beads were prepared via controlled suspension polymerization in a spiral-shaped microchannel using mineral oil and perfluorocarbon liquid as continuous phases. Monodisperse droplets containing the monomers, template, initiator, and porogenic solvent were introduced into the microchannel, and particles of uniform size were produced by subsequent UV polymerization, quickly and without wasting polymer materials. The droplet/particle size was varied by changing the flow conditions in the microfluidic device. The diameter of the resulting products typically had a coefficient of variation (CV) below 2%. The specific binding sites that were created during the imprinting process were analysed via radioligand binding analysis. The molecularly imprinted microspheres produced in the liquid perfluorocarbon continuous phase had a higher binding capacity compared with the particles produced in the mineral oil continuous phase, though it should be noted that the aim of this study was not to optimize or maximize imprinting performance, but rather to demonstrate broad applicability and compatibility with known MIP production methods. The successful imprinting against a model compound using two very different continuous phases (one requiring a surfactant to stabilize the droplets the other not) demonstrates the generality of this current simple approach.
We demonstrate two new methods for coalescing aqueous microdroplets in an oil filled flow channel. In the first method two droplets produced by shear induced detachment are merged by the application of a D.C. voltage. In the second method, three aqueous microdroplets, again in an oil filled flow, channel, are coalesced simultaneously by the application of a D.C. voltage, with one microdroplet being produced by shear induced detachment and the other two being electrically produced, on-demand.