The INFN Laboratori Nazionali di Frascati was established in 1954 to host an electro-synchrotron, the first particle accelerator built in Italy, and since then played a crucial role in the field of nuclear and particle physics and for the development of acceleration and detection technologies. Within this historical tradition, a workshop was organized at LNF in the framework of the Nuclear Physics Mid Term Plan Italy, an initiative of the Nuclear Physics Division of the Istituto Nazionale di Fisica Nucleare, to discuss the detection techniques employed in nuclear physics and to identify the open issues to be addressed to realize the scientific programs of the experiments foreseen in a midterm perspective. The present report summarizes the outcome of the discussions.
Partial breast irradiation for the treatment of early-stage breast cancer patients can be performed by means of Intra Operative electron Radiation Therapy (IOeRT). One of the main limitations of this technique is the absence of a treatment planning system (TPS) that could greatly help in ensuring a proper coverage of the target volume during irradiation. An IOeRT TPS has been developed using a fast Monte Carlo (MC) and an ultrasound imaging system to provide the best irradiation strategy (electron beam energy, applicator position and bevel angle) and to facilitate the optimisation of dose prescription and delivery to the target volume while maximising the organs at risk sparing. The study has been performed in silico, exploiting MC simulations of a breast cancer treatment. Ultrasound-based input has been used to compute the absorbed dose maps in different irradiation strategies and a quantitative comparison between the different options was carried out using Dose Volume Histograms.The system was capable of exploring different beam energies and applicator positions in few minutes, identifying the best strategy with an overall computation time that was found to be completely compatible with clinical implementation. The systematic uncertainty related to tissue deformation during treatment delivery with respect to imaging acquisition was taken into account.The potential and feasibility of a GPU based full MC TPS implementation of IOeRT breast cancer treatments has been demonstrated in-silico. This long awaited tool will greatly improve the treatment safety and efficacy, overcoming the limits identified within the clinical trials carried out so far.
Introduction: Charged Particle Therapy plays a key role in the treatment of deep-seated tumours, because of the advantageous energy deposition culminating in the Bragg peak. However, knowledge of the dose delivered in the entrance channel is limited by the lack of data on the beam and fragmentation of the target.Methods: The FOOT experiment has been designed to measure the cross sections of the nuclear fragmentation of projectile and target with two different detectors: an electronic setup for the identification of Z ≥ 3 fragments and a nuclear emulsion spectrometer for Z ≤ 3 fragments. In this paper, we analyze the data taken by exposing four nuclear emulsion spectrometers, with C and C2H4 targets, to 200 MeV/n and 400 MeV/n oxygen beams at GSI Helmholtzzentrum für Schwerionenforschung (Darmstadt, Germany), and we report the charge identification of produced fragments based on the controlled fading induced on nuclear emulsion films.Results: The goal of identifying fragments as heavy as lithium has been achieved.Discussion: The results will contribute to a better understanding of the nuclear fragmentation process in charged particle therapy and have implications for refining treatment planning in the presence of deep-seated tumors.
The treatment of deep-seated tumours with electrons of very high energies (VHEE, 70–150 MeV) has already been explored in the past, suggesting that a dosimetric coverage comparable with state-of-the-art proton (PT) or photon radiotherapy (RT) could be achieved with a large ( > 10) number of fields and high electron energy. The technical and economical challenges posed by the deployment of such beams in treatment centres, together with the expected small therapeutic gain, prevented the development of such technique. This scenario could radically change in the light of recent developments that occurred in the compact, high-gradient, electron acceleration technology and, additionally, of the experimental evidence of the sparing of organs at risk achieved in ultra-high dose rate irradiation, also referred to as FLASH. Electrons with the energy required to treat intracranial lesions could be provided, at dose rates compatible with what is needed to trigger the FLASH effect, by accelerators that are a few metres long, and the organ sparing could be exploited to significantly simplify the irradiation geometry, decreasing the number of fields needed to treat a patient. In this paper, the case of two patients affected by a chordoma and a meningioma, respectively, treated with protons in Trento (IT) is presented. The proton plans have been compared with VHEE plans and X-ray intensity-modulated radiotherapy (IMRT) plans. The VHEE plans were first evaluated in terms of physical dose distribution and then assuming that the FLASH regimen can be achieved. VHEE beams demonstrated their potential in obtaining plans that have comparable tumour coverage and organs at risk sparing when benchmarked against current state-of-the-art IMRT and PT. These results were obtained with a number of explored fields that was in the range between 3 and 7, consistent with what is routinely performed in IMRT and PT conventional irradiations. The FLASH regimen, in all cases, showed its potential in reducing damage to the organs placed nearby the target volume, allowing, particularly in the chordoma case where the irradiation geometry is more challenging, a better tumour coverage with respect to the conventional treatments.
Objective. The Monte Carlo simulation software is a valuable tool in radiation therapy, in particular to achieve the needed accuracy in the dose evaluation for the treatment plans optimisation. The current challenge in this field is the time reduction to open the way to many clinical applications for which the computational time is an issue. In this manuscript we present an innovative GPU-accelerated Monte Carlo software for dose valuation in electron and photon based radiotherapy, developed as an update of the FRED (Fast paRticle thErapy Dose evaluator) software.Approach. The code transports particles through a 3D voxel grid, while scoring their energy deposition along their trajectory. The models of electromagnetic interactions in the energy region between 1 MeV-1 GeV available in literature have been implemented to efficiently run on GPUs, allowing to combine a fast tracking while keeping high accuracy in dose assessment. The FRED software has been bench-marked against state-of-art full MC (FLUKA, GEANT4) in the realm of two different radiotherapy applications: Intra-Operative Radio Therapy and Very High Electron Energy radiotherapy applications.Results. The single pencil beam dose-depth profiles in water as well as the dose map computed on non-homogeneous phantom agree with full-MCs at 2% level, observing a gain in processing time from 200 to 5000.Significance. Such performance allows for computing a plan with electron beams in few minutes with an accuracy of ∼%, demonstrating the FRED potential to be adopted for fast plan re-calculation in photon or electron radiotherapy applications.
Organic plastic scintillators are largely exploited for fast timing detectors thanks to their short scintillation time with respect to inorganic crystals. Plastic scintillators are cheap to produce, light and easy to manipulate (any standard mechanical workshop can handle the cutting, polishing, etc.). Nowadays, fastest plastic scintillators available on the market are EJ-232 (Eljen Technology) and BC-422 (Saint Gobain) with a rise time of 350ps, a decay time of 1.6ns and a pulse width of 1.3ns. Foreseen the performance improvement of timing detectors based on plastic scintillators, the development of faster scintillators can give a crucial contribution. TOPS is a project focused on the development of a new class of organic scintillators producing several liquid and solid samples. Comparing the light output and the timing properties of the samples exploiting minimum ionising particles, a selection of the highly performing TOPS scintillators has been investigated and characterised. The performance achieved with TOPS samples are extremely promising: a time resolution improvement from 10 up to 35% with respect to the EJ-232 has been demonstrated. In addition, an increase of light output has been obtained for all samples with a consequent potential improvement in energy resolution measurements of a factor up to 35%.
The study of nuclear fragmentation plays a central role in many important applications: from the study of Particle Therapy (PT) up to radiation protection for space (RPS) missions and the design of shielding for nuclear reactors. The FragmentatiOn Of Target (FOOT) collaboration aims to study the nuclear reactions that describe the interactions with matter of different light ions (like H1 , He4 , C12 , O16 ) of interest for such applications, performing double differential fragmentation cross section measurements in the energy range of interest for PT and RPS. In this manuscript, we present the analysis of the data collected in the interactions of an oxygen ion beam of 400 MeV/u with a graphite target using a partial FOOT setup, at the GSI Helmholtz Center for Heavy Ion Research facility in Darmstadt. During the data taking the magnets, the silicon trackers and the calorimeter foreseen in the final FOOT setup were not yet available, and hence precise measurements of the fragments kinetic energy, momentum and mass were not possible. However, using the FOOT scintillator detectors for the time of flight (TOF) and energy loss (Δ E ) measurements together with a drift chamber, used as beam monitor, it was possible to measure the elemental fragmentation cross sections. The reduced detector set-up and the limited available statistics allowed anyway to obtain relevant results, providing statistically significant measurements of cross sections eagerly needed for PT and RPS applications. Whenever possible the obtained results have been compared with existing measurements helping in discriminating between conflicting results in the literature and demonstrating at the same time the proper functioning of the FOOT ΔE-TOF system. Finally, the obtained fragmentation cross sections are compared to the Monte Carlo predictions obtained with the FLUKA software.
The goals of the FOOT (FragmentatiOn Of Target) experiment are to measure the proton double differential fragmentation cross-section on H, C, O targets at beam energies of interest for hadrontherapy (50–250 MeV for protons and 50–400 MeV/u for carbon ions), and also at higher energy, up to 1 GeV/u for radioprotection in space. Given the short range of the fragments, an inverse kinematic approach has been chosen, requiring precise tracking capabilities for charged particles. One of the subsystems designed for the experiment will be the MSD (Microstrip Silicon Detector), consisting of three x-y measurement planes, each one made by two single sided silicon microstrip sensors. In this document, we will present a detailed description of the first MSD prototype assembly, developed by INFN Perugia group and the subsequent characterization of the detector performance. The prototype is a wide area (∼ 100 cm2) single sensor, 150 μm thick to reduce material budget and fragmentation probability along the beam path, with 50 μm strip pitch and 2 floating strip readout approach. The pitch adapter to connect strips with the readout channels of the ASIC has been implemented directly on the silicon surface. Beside the interest for the FOOT experiment, the results in terms of cluster signal, signal-to-noise ratio, dynamic range of the readout chips, as well as long-term stability studies in terms of noise, are relevant also for other experiments where the use of thin sensors is crucial.
FLASH Radiotherapy is currently being studied and actively explored by medical and radiobiology communities as one of the most promising technological break-through in the future of cancer treatment as it could considerably improve the sparing of healthy tissues when compared to conventional radiotherapy. However, the FLASH effect activation mechanism still needs a thorough investigation before the characteristics of a therapeutic beam could be properly defined. In this manuscript, a new method for the on-line monitoring of therapeutic beams at FLASH intensities, based on air fluorescence and developed within the FlashDC project, is presented.
Morphological changes that may arise through a treatment course are probably one of the most significant sources of range uncertainty in proton therapy. Non-invasive in-vivo treatment monitoring is useful to increase treatment quality. The INSIDE in-beam Positron Emission Tomography (PET) scanner performs in-vivo range monitoring in proton and carbon therapy treatments at the National Center of Oncological Hadrontherapy (CNAO). It is currently in a clinical trial (ID: NCT03662373) and has acquired in-beam PET data during the treatment of various patients. In this work we analyze the in-beam PET (IB-PET) data of eight patients treated with proton therapy at CNAO. The goal of the analysis is twofold. First, we assess the level of experimental fluctuations in inter-fractional range differences (sensitivity) of the INSIDE PET system by studying patients without morphological changes. Second, we use the obtained results to see whether we can observe anomalously large range variations in patients where morphological changes have occurred. The sensitivity of the INSIDE IB-PET scanner was quantified as the standard deviation of the range difference distributions observed for six patients that did not show morphological changes. Inter-fractional range variations with respect to a reference distribution were estimated using the Most-Likely-Shift (MLS) method. To establish the efficacy of this method, we made a comparison with the Beam’s Eye View (BEV) method. For patients showing no morphological changes in the control CT the average range variation standard deviation was found to be 2.5 mm with the MLS method and 2.3 mm with the BEV method. On the other hand, for patients where some small anatomical changes occurred, we found larger standard deviation values. In these patients we evaluated where anomalous range differences were found and compared them with the CT. We found that the identified regions were mostly in agreement with the morphological changes seen in the CT scan.
Long-lived particles decaying to e ^±μ ^∓ν , with masses between 7 and 50 GeV/c^2 and lifetimes between 2 and 50 ps , are searched for by looking at displaced vertices containing electrons and muons of opposite charges. The search is performed using 5.4 fb ^-1 of p p collisions collected with the LHCb detector at a centre-of-mass energy of √(s) = 13 TeV . Three mechanisms of production of long-lived particles are considered: the direct pair production from quark interactions, the pair production from the decay of a Standard-Model-like Higgs boson with a mass of 125 GeV/c^2 , and the charged current production from an on-shell W boson with an additional lepton. No evidence of these long-lived states is obtained and upper limits on the production cross-section times branching fraction are set on the different production modes.
A search is performed for heavy neutrinos in the decay of a W boson into two muons and a jet. The data set corresponds to an integrated luminosity of approximately 3.0 fb-1 of proton-proton collision data at centre-of-mass energies of 7 and 8 TeV collected with the LHCb experiment. Both same-sign and opposite-signmuons in the final state are considered. Data are found to be consistent with the expected background. Upper limits on the coupling of a heavy neutrino with the Standard Model neutrino are set at 95% confidence level in the heavy-neutrino mass range from 5 to 50GeV/c2. These are of the order of 10(-3) for lepton-number-conserving decays and of the order of 10(-4) for lepton-number-violating heavy-neutrino decays.
The production of ${\ensuremath{\chi}}_{c1}(3872)$ and $\ensuremath{\psi}(2S)$ hadrons is studied as a function of charged particle multiplicity in $pp$ collisions at a center-of-mass energy of 8 TeV, corresponding to an integrated luminosity of $2\text{ }\text{ }{\mathrm{fb}}^{\ensuremath{-}1}$. For both states, the fraction that is produced promptly at the collision vertex is found to decrease as charged particle multiplicity increases. The ratio of ${\ensuremath{\chi}}_{c1}(3872)$ to $\ensuremath{\psi}(2S)$ cross sections for promptly produced particles is also found to decrease with multiplicity, while no significant dependence on multiplicity is observed for the equivalent ratio of particles produced away from the collision vertex in $b$-hadron decays. This behavior is consistent with a calculation that models the ${\ensuremath{\chi}}_{c1}(3872)$ structure as a compact tetraquark. Comparisons with model calculations and implications for the binding energy of the ${\ensuremath{\chi}}_{c1}(3872)$ state are discussed.
The ratio of the B-s(0) and B-0 fragmentation fractions, f(s)/f(d), in proton-proton collisions at the LHC, is obtained as a function of B-meson transverse momentum and collision center-of-mass energy from the combined analysis of different B-decay channels measured by the LHCb experiment. The results are described by a linear function of the meson transverse momentum or with a function inspired by Tsallis statistics. Precise measurements of the branching fractions of the B-s(0) -> J/psi phi and B-s(0)-> D-s(-)pi(+) decays are performed, reducing their uncertainty by about a factor of 2 with respect to previous world averages. Numerous B-s(0) decay branching fractions, measured at the LHCb experiment, are also updated using the new values of f(s)/f(d) and branching fractions of normalization channels. These results reduce a major source of systematic uncertainty in several searches for new physics performed through measurements of B-s(0) branching fractions.