Antimicrobials (e.g., antibiotics and biocides) are invaluable chemicals used to control microbes in numerous contexts. Because of the simultaneous use of antibiotics and biocides, questions have arisen as to whether environments commonly treated with biocides (e.g., hospitals, food processing, wastewater, agriculture, etc.) could act as a reservoir for the development of antibiotic cross-resistance. Theoretically, cross-resistance could occur if the mechanism of bacterial tolerance to biocides also resulted in antibiotic resistance. On the other hand, biocides would likely present a higher evolutionary barrier to the development of resistance given the different modes of action between biocides and antibiotics and the broad-based physicochemical effects associated with most biocides. Published studies have shown that the induction of biocide tolerance in a laboratory can result in cross-resistance to some antibiotics, most commonly hypothesized to be due to efflux pump upregulation. However, testing of environmental isolates for biocide tolerance and antibiotic cross-resistance has yielded conflicting results, potentially due to the lack of standardized testing. In this review, we aim to describe the state of the science on the potential linkage between biocide tolerance and antibiotic cross-resistance. Questions still remain about whether the directed evolution of biocide tolerance and the associated antibiotic cross-resistance in a laboratory are or are not representative of real-world settings. Thus, research should continue to generate informative data to guide policies and preserve these tools' utility and availability.
Abstract. Significance: Diffuse optical imaging (DOI) provides in vivo quantification of tissue chromophores such as oxy- and deoxyhemoglobin (HbO2 and HHb, respectively). These parameters have been shown to be useful for predicting neoadjuvant treatment response in breast cancer patients. However, most DOI devices designed for the breast are nonportable, making frequent longitudinal monitoring during treatment a challenge. Furthermore, hemodynamics related to the respiratory cycle are currently unexplored in the breast and may have prognostic value. Aim: To design, fabricate, and validate a high optode-density wearable continuous wave diffuse optical probe for the monitoring of breathing hemodynamics in breast tissue. Approach: The probe has a rigid-flex design with 16 dual-wavelength sources and 16 detectors. Performance was characterized on tissue-simulating phantoms, and validation was performed through flow phantom and cuff occlusion measurements. The breasts of N = 4 healthy volunteers were measured while performing a breathing protocol. Results: The probe has 512 unique source–detector (S-D) pairs that span S-D separations of 10 to 54 mm. It exhibited good performance characteristics: μa drift of 0.34%/h, μa precision of 0.063%, and mean SNR ≥ 24 dB up to 41 mm S-D separation. Absorption contrast was detected in flow phantoms at depths exceeding 28 mm. A cuff occlusion measurement confirmed the ability of the probe to track expected hemodynamics in vivo. Breast measurements on healthy volunteers during paced breathing revealed median signal-to-motion artifact ratios ranging from 8.1 to 8.7 dB. Median ΔHbO2 and ΔHHb amplitudes ranged from 0.39 to 0.67 μM and 0.08 to 0.12 μM, respectively. Median oxygen saturations at the respiratory rate ranged from 82% to 87%. Conclusions: A wearable diffuse optical probe has been designed and fabricated for the measurement of breast tissue hemodynamics. This device is capable of quantifying breathing-related hemodynamics in healthy breast tissue.
Abstract Objective Bone augmentation delays implant placement and increases risks due to additional surgeries. Implant systems compatible with reduced alveolar bone volume are required. To design, manufacture, and test a non‐cylindrical dental implant system using piezotomes and custom‐designed matching titanium mini‐implants to address the needs of patients with missing teeth and narrow jawbone. Materials and methods Tapered mini‐implants with a rectangular cross‐section (4.6 mm × 2.1 mm) were machined with dimensions that could accommodate narrow alveolar ridges. The performance of the implants were tested in both static and fatigue cycle 30° compression tests. Tapered, rectangular cutting tools that matched the overall trapezoidal morphology of the implant were also designed. These novel tools were engineered to be compatible with commercially available piezoelectric osteotomes. Tools were optimized using finite element analysis and were manufactured accordingly and were used by a periodontal surgery team in a pork rib bone model to monitor utility of the device and ease of use. Results The rectangular design of the implant allows for a full occlusal load due to the larger implant flexural rigidity compared to a similar diameter mini‐implant with a standard cylindrical design. During 30° compression fatigue tests, the implant tested at 340 N did not fail after 5M cycles as shown in Kaplan‐Meier survival curves. Finite element analysis allowed for functional optimization of the roughing and finishing tools. In the pork rib model, these tools successfully cut trapezoidal holes that matched the dimensions of the implant. Conclusions The implant system here demonstrates the feasibility of a mini‐implant system that has superior flexural rigidity and potentially circumvents the need for patient bone augmentation.
Additive manufacturing is poised to enable the next biomedical revolution, where customized, patient-specific tools, therapies, pharmaceuticals, and even replacement organs are taking strides in the biomedical research and development space. Polymeric materials are capable of making inroads in a wide variety of biomedical applications, and in recent years a growing number are being used with additive manufacturing techniques. This review highlights some of the emerging classes of polymers used in additive manufacturing and examples of their use in biomedical applications, with a focus on the delineation of ‘hard’ polymers versus ‘soft’ polymers and the specific applications where they are utilized.
One of the main challenges in the diagnosis of infectious diseases is the need for rapid and accurate detection of the causative pathogen in any setting. Rapid diagnosis is key to avoiding the spread of the disease, to allow proper clinical decisions to be made in terms of patient treatment, and to mitigate the rise of drug-resistant pathogens. In the last decade, significant interest has been devoted to the development of point-of-care reverse transcription polymerase chain reaction (PCR) platforms for the detection of RNA-based viral pathogens. We present the development of a microfluidic, real-time, fluorescence-based, continuous-flow reverse transcription PCR system. The system incorporates a disposable microfluidic chip designed to be produced industrially with cost-effective roll-to-roll embossing methods. The chip has a long microfluidic channel that directs the PCR solution through areas heated to different temperatures. The solution first travels through a reverse transcription zone where RNA is converted to complementary DNA, which is later amplified and detected in real time as it travels through the thermal cycling area. As a proof of concept, the system was tested for Ebola virus detection. Two different master mixes were tested, and the limit of detection of the system was determined, as was the maximum speed at which amplification occurred. Our results and the versatility of our system suggest its promise for the detection of other RNA-based viruses such as Zika virus or chikungunya virus, which constitute global health threats worldwide.
A reduced channel height in microfluidic Lab-on-a-Chip (LOC) devices enables a reduction in the required volume of sample and reagents. LOC devices are most often manufactured by microstructuring a planar substrate and subsequently sealing it with a cover film. However, shallow chip designs, made from polymers, are sensitive to channel deformation during the sealing of the microfluidic device. Inappropriate bonding conditions often result in the loss of the microfluidic functionality. A systematic and practical approach for the identification of suitable bonding process parameters is missing. In this article, a straightforward approach for the optimization of channel integrity in the sealing of shallow microfluidic devices made from Cyclic Olefin Polymer (COP) is presented. Two COP materials were tested: COP Zeonex 690R (Glass transition temperature Tg = 135 °C) both as a cover film and substrate material, and COP ZF14 (Tg = 135 °C) as a film material. A mechanical analysis using microstructured Zeonex 690R substrates was performed to generate a matrix of low-distortion bonding parameters, including temperature, pressure and time. The well-established method of solvent-assisted bonding was used to enhance the characteristically low bond strengths of the native COP material. In addition, plasma-assisted bonding was tested and compared. The optimization approach was validated by the manufacture of a microfluidic test device, the demonstration of its microfluidic functionality, and the quantitative evaluation of the achieved channel integrity.
Purpose: Loss of corneal endothelial cells (CECs) bears disastrous consequences for the patient, including corneal clouding and blindness. Corneal transplantation is currently the only therapy for severe corneal disorders. However, the worldwide shortages of corneal donor material generate a strong demand for personalized stem cell–based alternative therapies. Because human mesenchymal stem cells are known to be sensitive to their mechanical environments, we investigated the mechanotransductive potential of Descemet membrane–like microtopography (DLT) to differentiate human mesenchymal stem cells into CEC-like cells. Methods: Master molds with inverted DLT were produced by 2-photon lithography (2-PL). To measure the mechanotransductive potential of DLT, mesenchymal stem cells were cultivated on silicone or collagen imprints with DLT. Changes in morphology were imaged, and changes in gene expression of CEC typical genes such as zonula occludens (ZO-1), sodium/potassium (Na/K)-ATPase, paired-like homeodomain 2 (PITX2), and collagen 8 (COL-8) were measured with real-time polymerase chain reaction. At least immunofluorescence analysis has been conducted to confirm gene data on the protein level. Results: Adhesion of MSCs to DLT molded in silicone and particularly in collagen initiates polygonal morphology and monolayer formation and enhances not only transcription of CEC typical genes such as ZO-1, Na/K-ATPase, PITX2, and COL-8 but also expression of the corresponding proteins. Conclusions: Artificial reproduction of Descemet membrane with respect to topography and similar stiffness offers a potential innovative way to bioengineer a functional CEC monolayer from autologous stem cells.
The rapid evolution of antibiotic resistance in bacterial pathogens is driving the development of innovative, rapid antibiotic susceptibility testing (AST) tools as a way to provide more targeted and timely antibiotic treatment. We have previously presented a stress-based microfluidic method for the rapid determination of antibiotic susceptibility in methicillin-susceptible Staphylococcus aureus (MSSA) and methicillin-resistant Staphylococcus aureus (MRSA). In this method, stress is used to potentiate the action of antibiotics, and cell death is measured as a proxy for susceptibility. The method allows antibiotic susceptibility to be determined within an hour from the start of the antibiotic introduction. However, the relatively low dynamic range of the signal (2–10% cell response) even with high antibiotic concentrations (10–50 µg/mL) left room for the method’s optimization. We have conducted studies in which we varied the flow patterns, the media composition, and the antibiotic concentration to increase the cell death response and concordantly decrease the required antibiotic concentration down to 1–3 µg/mL, in accordance with the Clinical and Laboratory Standards Institute’s (CLSI) guidelines for AST breakpoint concentrations.
Stem cells play a dominant role in biological research and have a significant potential, as test systems for drug screening, disease modeling and therapeutic applications. The automated production of different stem cell types such as iPS and MSC has been realized in recent years by a few research groups. Yet, it requires different approaches in parallelization compared to conventional automated production because of the nature of the living cells on the one hand, and the production system with various interconnected devices on the other hand. Within this work, we present an approach for parallel processing on an automated cell culture platform.
The increased world-wide availability of point-of-care (POC) tests utilizing fingerstick blood has led to testing scenarios in which multiple separate fingersticks are performed during a single patient encounter, generating cumulative discomfort and reducing testing efficiency. We have developed a device capable of a) collection of up to 100 μL of fingerstick blood from a single fingerstick by capillary action, and b) dispensing this blood in variable increments set by the user. We tested the prototype device both in a controlled laboratory setting and in a fingerstick study involving naive device users, and found it to have accuracy and precision similar to a conventional pipettor. The users also found the device to be easy to use, and recommended minor ergonomic improvements. Our device would allow performance of multiple POC tests from a single fingerstick blood sample, thus providing a novel functionality that may be of use in many testing settings worldwide.
Due to its relatively low level of antigenicity and high durability, titanium has successfully been used as the major material for biological implants. However, because the typical interface between titanium and tissue precludes adequate transmission of load into the surrounding bone, over time, load-bearing implants tend to loosen and revision surgeries are required. Osseointegration of titanium implants requires presentation of both biological and mechanical cues that promote attachment of and trigger mineral deposition by osteoblasts. While many factors contribute to differentiation, the relative importance of the various cues is unclear. To substantially improve osseointegration of titanium implants, we generated a gelatin methacryloyl (GelMA) scaffold, using an extrusion-based 3D bioprinter, which can be directly printed on and grafted to the titanium implant surface. We demonstrate that this scaffold is able to trigger mineral deposition of both MG63 osteoblasts and primary normal human osteoblasts in the absence of any exogenous osteogenic factors. Films of the same formulation failed to promote mineral deposition suggesting that the three dimensional scaffold was able to tip the balance in favor of differentiation despite other potentially unfavorable differentiation cues of the material. We further show that these GelMA lattices can be directly grafted to titanium alloy and are secure in vitro over a period of seven weeks. When grafted within a groove system, the GelMA hydrogel is protected from shearing forces in a marrow implantation model. This prepares the way for osteogenic coatings to be directly manufactured on the implant surface and packaged for surgery.
Bacteremia is a life-threatening condition for which antibiotics must be prescribed within hours of clinical diagnosis. Since the current gold standard for bacteremia diagnosis is based on conventional methods developed in the mid-1800s—growth on agar or in broth—identification and susceptibility profiling for both Gram-positive and Gram-negative bacterial species requires at least 48–72 h. Recent advancements in accelerated phenotypic antibiotic susceptibility testing have centered on the microscopic growth analysis of small bacterial populations. These approaches are still inherently limited by the bacterial growth rate. Our approach is fundamentally different. By applying environmental stress to bacteria in a microfluidic platform, we can correctly assign antibiotic susceptibility profiles of clinically relevant Gram-negative bacteria within two hours of antibiotic introduction rather than 8–24 h. The substantial expansion to include a number of clinical isolates of important Gram-negative species— Enterobacter cloacae , Escherichia coli , Klebsiella pneumoniae , and Pseudomonas aeruginosa —reported here underscores the broad utility of our approach, complementing the method’s proven utility for Gram-positive bacteria. We also demonstrate that the platform is compatible with antibiotics that have varying mechanisms of action—meropenem, gentamicin, and ceftazidime—highlighting the versatility of this platform.
Viable cells from healthy tissues are a rich resource in high demand for many next-generation therapeutics and regenerative medicine applications. Cell extraction from the dense connective matrix of most tissues is a labor-intensive task and high variability makes cGMP compliance difficult. To reduce costs and ensure greater reproducibility, automated tissue dissociators compatible with robotic liquid handling systems are required. Here we demonstrate the utility of our automated tissue dissociator that is compatible with standard microtiter well plates for high-throughput processing. We show that viable cell yields match or exceed manual methods while reducing processing time by at least 85%.
Traditional methods for identifying pathogens in bacteremic patients are slow (24-48+ h). This can lead to physicians making treatment decisions based on an incomplete diagnosis and potentially increasing the patient's mortality risk. To decrease time to diagnosis, we have developed a novel technology that can recover viable bacteria directly from whole blood and identify them in less than 7 h. Our technology combines a sample preparation process with surface-enhanced Raman spectroscopy (SERS). The sample preparation process enriches viable microorganisms from 10 mL of whole blood into a 200 μL aliquot. After a short incubation period, SERS is used to identify the microorganisms. We further demonstrated that SERS can be used as a broad detection method, as it identified a model set of 17 clinical blood culture isolates and microbial reference strains with 100% identification agreement. By applying the integrated technology of sample preparation and SERS to spiked whole blood samples, we were able to correctly identify both Staphylococcus aureus and Escherichia coli 97% of the time with 97% specificity and 88% sensitivity.
The dominant molecular species contributing to the surface-enhanced Raman spectroscopy (SERS) spectra of bacteria excited at 785 nm are the metabolites of purine degradation: adenine, hypoxanthine, xanthine, guanine, uric acid, and adenosine monophosphate. These molecules result from the starvation response of the bacterial cells in pure water washes following enrichment from nutrient-rich environments. Vibrational shifts due to isotopic labeling, bacterial SERS spectral fitting, SERS and mass spectrometry analysis of bacterial supernatant, SERS spectra of defined bacterial mutants, and the enzymatic substrate dependence of SERS spectra are used to identify these molecular components. The absence or presence of different degradation/salvage enzymes in the known purine metabolism pathways of these organisms plays a central role in determining the bacterial specificity of these purine-base SERS signatures. These results provide the biochemical basis for the development of SERS as a rapid bacterial diagnostic and illustrate how SERS can be applied more generally for metabolic profiling as a probe of cellular activity. Graphical Abstract Bacterial typing by metabolites released under stress.
We present a new continuous-wave (CW) wearable diffuse optical device aimed at investigating the hemodynamic response of locally advanced breast cancer patients during a patient's first neoadjuvant chemotherapy infusion. The system consists of a flexible substrate that supports an array of surface-mount LED and photodiode pairs (i.e. optodes). Probe performance was evaluated using solid tissue-simulating phantoms. Measurements revealed high SNR (65dB), low source-detector crosstalk (-59 dB), high measurement precision (0.17%), and good thermal stability (0.2% V-rms/degrees C). A cuff occlusion experiment was performed on the forearm of a healthy volunteer to demonstrate the ability to track rapid hemodynamic changes.
In this paper, we present a portable and low cost point-of-care (POC) PCR system for quantitative detection of pathogens. Our system is based on continuous flow PCR which maintains fixed temperatures zones and pushes the PCR solution between two heated areas allowing for faster heat transfer and as a result, a faster PCR. The PCR system is built around a 46.0 mm × 30.9 mm × 0.4 mm disposable thermoplastic chip. In order to make the single-use chip economically viable, it was manufactured by hot embossing and was designed to be compatible with roll-to-roll embossing for large scale production. The prototype instrumentation surrounding the chip includes two heaters, thermal sensors, and an optical system. The optical system allows for pathogen detection via real time fluorescence measurements. FAM probes were used as fluorescent reporters of the amplicons generated during the PCR. To demonstrate the function of the chip, two infectious bacteria targets were selected: Chlamydia trachomatis and Escherichia coli O157:H7. For both bacteria, the limit of detection of the system was determined, PCR efficiencies were calculated, and different flow velocities were tested. We have demonstrated successful detection for these two bacterial pathogens highlighting the versatility and broad utility of our portable, low-cost, and rapid PCR diagnostic device.
The 5-year survival rate for ovarian cancer is only 45% largely due to lack of effective screening methods. Current methods include palpation, transvaginal ultrasound, and the CA-125 blood test. Finding disease reliably and at an early stage increase survival to 92%. We have designed and built a 0.7 mm endoscope for the early detection of ovarian cancer. Inserted transvaginally through the working channel of a hysteroscope, the falloposcope creates a minimally invasive procedure for the screening of high risk women. To improve the ease-of-use and safety of falloposcope deployment, we are working to create an everting balloon. Currently, the falloposcope would require a skilled user to operate due to the challenging anatomy of the fallopian tubes - a small opening from the uterus (< 1 mm), tortuous path, and delicate lumenal features. A balloon delivery system would gently open the fallopian tube and guide the falloposcope down the center of lumen. We show balloon design and discuss integration with the falloposcope prototype. We test possible mechanical damage to the tissue due to scraping, puncture, or overstretching. Successful introduction of the everting balloon to simplify falloposcope delivery could expand screening beyond specialized centers to smaller clinical locations.
We have developed a three-dimensional (3D) bioprinting system capable of multimaterial and multiscale deposition to enable the next generation of “bottom-up” tissue engineering. This area of research resides at the interface of engineering and life sciences. As such, it entails the design and implementation of diverse elements: a novel hydrogel-based bioink, a 3D bioprinter, automation software, and mammalian cell culture. Our bioprinter has three components uniquely combined into a comprehensive tool: syringe pumps connected to a selector valve that allow precise application of up to five different materials with varying viscosities and chemistries, a high velocity/high-precision x–y–z stage to accommodate the most rapid speeds allowable by the printed materials, and temperature control of the bioink reservoirs, lines, and printing environment. Our custom-designed bioprinter is able to print multiple materials (or multiple cell types in the same material) concurrently with various feature sizes (100 μm–1 mm wide; 100 μm–1 cm high). One of these materials is a biocompatible, printable bioink that has been used to test for cell survival within the hydrogel following printing. Hand-printed (HP) controls show that our bioprinter does not adversely affect the viability of the printed cells. Here, we report the design and build of the 3D bioprinter, the optimization of the bioink, and the stability and viability of our printed constructs.