The United States needs an integrated national strategy to address the twin challenges of bolstering its manufacturing sector and averting climate change. Timely federal RD&D and deployment policies targeted to specific manufacturing industries could create comparative advantage, expanding domestic investment and employment. KEY TAKEAWAYS ▪ Sincere efforts to fulfill national pledges to achieve net-zero emissions will drive a nearly complete retooling of global manufacturing. ▪ This retooling gives the United States a chance to rebuild domestic manufacturing while converting to clean production. To seize it, the federal government must act strategically and forcefully to leverage the nation’s strength in innovation. ▪ Clean hydrogen production will become a core sector of the global low-carbon economy. Focused policies could enable significant domestic investment and job creation, both in the industry itself and in hydrogen-using industries like steelmaking. ▪ Next-generation heat pumps, novel drying technologies, and related innovations will be in high demand worldwide to cut emissions from buildings and low-temperature industrial processes. Smart, targeted policies could bring their production onshore. ▪ Clean chemical manufacturing will require innovations in recycling and bio-based production. A well-funded and coordinated national program could convert U.S. strengths in this industry into durable advantages and large rural investments. ▪ Biotechnology-based proteins could displace emissions from agriculture. The United States is a global leader in this emerging industry, and a robust federal policy could help secure that position.
One of the main challenges in the diagnosis of infectious diseases is the need for rapid and accurate detection of the causative pathogen in any setting. Rapid diagnosis is key to avoiding the spread of the disease, to allow proper clinical decisions to be made in terms of patient treatment, and to mitigate the rise of drug-resistant pathogens. In the last decade, significant interest has been devoted to the development of point-of-care reverse transcription polymerase chain reaction (PCR) platforms for the detection of RNA-based viral pathogens. We present the development of a microfluidic, real-time, fluorescence-based, continuous-flow reverse transcription PCR system. The system incorporates a disposable microfluidic chip designed to be produced industrially with cost-effective roll-to-roll embossing methods. The chip has a long microfluidic channel that directs the PCR solution through areas heated to different temperatures. The solution first travels through a reverse transcription zone where RNA is converted to complementary DNA, which is later amplified and detected in real time as it travels through the thermal cycling area. As a proof of concept, the system was tested for Ebola virus detection. Two different master mixes were tested, and the limit of detection of the system was determined, as was the maximum speed at which amplification occurred. Our results and the versatility of our system suggest its promise for the detection of other RNA-based viruses such as Zika virus or chikungunya virus, which constitute global health threats worldwide.
A reduced channel height in microfluidic Lab-on-a-Chip (LOC) devices enables a reduction in the required volume of sample and reagents. LOC devices are most often manufactured by microstructuring a planar substrate and subsequently sealing it with a cover film. However, shallow chip designs, made from polymers, are sensitive to channel deformation during the sealing of the microfluidic device. Inappropriate bonding conditions often result in the loss of the microfluidic functionality. A systematic and practical approach for the identification of suitable bonding process parameters is missing. In this article, a straightforward approach for the optimization of channel integrity in the sealing of shallow microfluidic devices made from Cyclic Olefin Polymer (COP) is presented. Two COP materials were tested: COP Zeonex 690R (Glass transition temperature Tg = 135 °C) both as a cover film and substrate material, and COP ZF14 (Tg = 135 °C) as a film material. A mechanical analysis using microstructured Zeonex 690R substrates was performed to generate a matrix of low-distortion bonding parameters, including temperature, pressure and time. The well-established method of solvent-assisted bonding was used to enhance the characteristically low bond strengths of the native COP material. In addition, plasma-assisted bonding was tested and compared. The optimization approach was validated by the manufacture of a microfluidic test device, the demonstration of its microfluidic functionality, and the quantitative evaluation of the achieved channel integrity.
Stem cells play a dominant role in biological research and have a significant potential, as test systems for drug screening, disease modeling and therapeutic applications. The automated production of different stem cell types such as iPS and MSC has been realized in recent years by a few research groups. Yet, it requires different approaches in parallelization compared to conventional automated production because of the nature of the living cells on the one hand, and the production system with various interconnected devices on the other hand. Within this work, we present an approach for parallel processing on an automated cell culture platform.
Due to its relatively low level of antigenicity and high durability, titanium has successfully been used as the major material for biological implants. However, because the typical interface between titanium and tissue precludes adequate transmission of load into the surrounding bone, over time, load-bearing implants tend to loosen and revision surgeries are required. Osseointegration of titanium implants requires presentation of both biological and mechanical cues that promote attachment of and trigger mineral deposition by osteoblasts. While many factors contribute to differentiation, the relative importance of the various cues is unclear. To substantially improve osseointegration of titanium implants, we generated a gelatin methacryloyl (GelMA) scaffold, using an extrusion-based 3D bioprinter, which can be directly printed on and grafted to the titanium implant surface. We demonstrate that this scaffold is able to trigger mineral deposition of both MG63 osteoblasts and primary normal human osteoblasts in the absence of any exogenous osteogenic factors. Films of the same formulation failed to promote mineral deposition suggesting that the three dimensional scaffold was able to tip the balance in favor of differentiation despite other potentially unfavorable differentiation cues of the material. We further show that these GelMA lattices can be directly grafted to titanium alloy and are secure in vitro over a period of seven weeks. When grafted within a groove system, the GelMA hydrogel is protected from shearing forces in a marrow implantation model. This prepares the way for osteogenic coatings to be directly manufactured on the implant surface and packaged for surgery.
Bacteremia is a life-threatening condition for which antibiotics must be prescribed within hours of clinical diagnosis. Since the current gold standard for bacteremia diagnosis is based on conventional methods developed in the mid-1800s—growth on agar or in broth—identification and susceptibility profiling for both Gram-positive and Gram-negative bacterial species requires at least 48–72 h. Recent advancements in accelerated phenotypic antibiotic susceptibility testing have centered on the microscopic growth analysis of small bacterial populations. These approaches are still inherently limited by the bacterial growth rate. Our approach is fundamentally different. By applying environmental stress to bacteria in a microfluidic platform, we can correctly assign antibiotic susceptibility profiles of clinically relevant Gram-negative bacteria within two hours of antibiotic introduction rather than 8–24 h. The substantial expansion to include a number of clinical isolates of important Gram-negative species— Enterobacter cloacae , Escherichia coli , Klebsiella pneumoniae , and Pseudomonas aeruginosa —reported here underscores the broad utility of our approach, complementing the method’s proven utility for Gram-positive bacteria. We also demonstrate that the platform is compatible with antibiotics that have varying mechanisms of action—meropenem, gentamicin, and ceftazidime—highlighting the versatility of this platform.
Viable cells from healthy tissues are a rich resource in high demand for many next-generation therapeutics and regenerative medicine applications. Cell extraction from the dense connective matrix of most tissues is a labor-intensive task and high variability makes cGMP compliance difficult. To reduce costs and ensure greater reproducibility, automated tissue dissociators compatible with robotic liquid handling systems are required. Here we demonstrate the utility of our automated tissue dissociator that is compatible with standard microtiter well plates for high-throughput processing. We show that viable cell yields match or exceed manual methods while reducing processing time by at least 85%.
Traditional methods for identifying pathogens in bacteremic patients are slow (24-48+ h). This can lead to physicians making treatment decisions based on an incomplete diagnosis and potentially increasing the patient's mortality risk. To decrease time to diagnosis, we have developed a novel technology that can recover viable bacteria directly from whole blood and identify them in less than 7 h. Our technology combines a sample preparation process with surface-enhanced Raman spectroscopy (SERS). The sample preparation process enriches viable microorganisms from 10 mL of whole blood into a 200 μL aliquot. After a short incubation period, SERS is used to identify the microorganisms. We further demonstrated that SERS can be used as a broad detection method, as it identified a model set of 17 clinical blood culture isolates and microbial reference strains with 100% identification agreement. By applying the integrated technology of sample preparation and SERS to spiked whole blood samples, we were able to correctly identify both Staphylococcus aureus and Escherichia coli 97% of the time with 97% specificity and 88% sensitivity.
In this paper, we present a portable and low cost point-of-care (POC) PCR system for quantitative detection of pathogens. Our system is based on continuous flow PCR which maintains fixed temperatures zones and pushes the PCR solution between two heated areas allowing for faster heat transfer and as a result, a faster PCR. The PCR system is built around a 46.0 mm × 30.9 mm × 0.4 mm disposable thermoplastic chip. In order to make the single-use chip economically viable, it was manufactured by hot embossing and was designed to be compatible with roll-to-roll embossing for large scale production. The prototype instrumentation surrounding the chip includes two heaters, thermal sensors, and an optical system. The optical system allows for pathogen detection via real time fluorescence measurements. FAM probes were used as fluorescent reporters of the amplicons generated during the PCR. To demonstrate the function of the chip, two infectious bacteria targets were selected: Chlamydia trachomatis and Escherichia coli O157:H7. For both bacteria, the limit of detection of the system was determined, PCR efficiencies were calculated, and different flow velocities were tested. We have demonstrated successful detection for these two bacterial pathogens highlighting the versatility and broad utility of our portable, low-cost, and rapid PCR diagnostic device.
We have developed a three-dimensional (3D) bioprinting system capable of multimaterial and multiscale deposition to enable the next generation of “bottom-up” tissue engineering. This area of research resides at the interface of engineering and life sciences. As such, it entails the design and implementation of diverse elements: a novel hydrogel-based bioink, a 3D bioprinter, automation software, and mammalian cell culture. Our bioprinter has three components uniquely combined into a comprehensive tool: syringe pumps connected to a selector valve that allow precise application of up to five different materials with varying viscosities and chemistries, a high velocity/high-precision x–y–z stage to accommodate the most rapid speeds allowable by the printed materials, and temperature control of the bioink reservoirs, lines, and printing environment. Our custom-designed bioprinter is able to print multiple materials (or multiple cell types in the same material) concurrently with various feature sizes (100 μm–1 mm wide; 100 μm–1 cm high). One of these materials is a biocompatible, printable bioink that has been used to test for cell survival within the hydrogel following printing. Hand-printed (HP) controls show that our bioprinter does not adversely affect the viability of the printed cells. Here, we report the design and build of the 3D bioprinter, the optimization of the bioink, and the stability and viability of our printed constructs.
Appropriate care for bacteremic patients is dictated by the amount of time needed for an accurate diagnosis. However, the concentration of microbes in the blood is extremely low in these patients (1-100 CFU/mL), traditionally requiring growth (blood culture) or amplification (e.g., PCR) for detection. Current culture-based methods can take a minimum of two days, while faster methods like PCR require a sample free of inhibitors (i.e., blood components). Though commercial kits exist for the removal of blood from these samples, they typically capture only DNA, thereby necessitating the use of blood culture for antimicrobial testing. Here, we report a novel, scaled-up sample preparation protocol carried out in a new microbial concentration device. The process can efficiently lyse 10 mL of bacteremic blood while maintaining the microorganisms' viability, giving a 30-μL final output volume. A suite of six microorganisms (Staphylococcus aureus, Streptococcus pneumoniae, Escherichia coli, Haemophilus influenzae, Pseudomonas aeruginosa, and Candida albicans) at a range of clinically relevant concentrations was tested. All of the microorganisms had recoveries greater than 55% at the highest tested concentration of 100 CFU/mL, with three of them having over 70% recovery. At the lowest tested concentration of 3 CFU/mL, two microorganisms had recoveries of ca. 40-50% while the other four gave recoveries greater than 70%. Using a Taqman assay for methicillin-sensitive S. aureus (MSSA)to prove the feasibility of downstream analysis, we show that our microbial pellets are clean enough for PCR amplification. PCR testing of 56 spiked-positive and negative samples gave a specificity of 0.97 and a sensitivity of 0.96, showing that our sample preparation protocol holds great promise for the rapid diagnosis of bacteremia directly from a primary sample.
We present a lab-on-a-chip and associated instrument for heterogeneous enzyme-linked immunosorbent assay (ELISA)-based detection of proteins from liquid samples. The system performs all necessary ELISA steps (starting from antigen incubation) in a quarter of the time required for corresponding plate-based protocols. We have previously described the instrument, which automates fluidic control via remote valve switching and detects fluorescence from reacted substrate, for use in a molecular diagnostics application. The ELISA chip reported here utilizes a high surface area bead bed to enhance capture efficiency and increase the dynamic range of the assay as compared to a standard plate-based ELISA. Its functionality is demonstrated using human IL-10 as a model antigen, but theoretically any sandwich ELISA could be ported onto this "open source platform." We show that our automated on-chip assays have greater sensitivities than the corresponding standard manual plate-based ELISAs, and that single samples can be assayed in a fraction of the time.
BACKGROUND:Compared with traditional open surgery, minimally invasive surgery may improve recovery and patient satisfaction while maintaining surgical principles. Laparoscopic, single incision, natural orifice, and robotic approaches hold their own appeal. However, they lack the ability to manipulate organs as easily as the human hand. Advances in minimally invasive surgical techniques require new tools with increased functionality of the end effectors. Multifunctional tools with greater dexterity than those currently available are highly desired.METHODS:To address this need, we designed, fabricated, and tested the first prototype of a laparoscopic tool that provides the dexterity of a hand. The "hand" has two jointed fingers and a jointed thumb attached to a laparoscopic sheath that can be collapsed to fit through a 12-mm trocar or small orifice. The handle provides control for three independent degrees of freedom: finger motion (bending/spreading), fingertip bending, and thumb bending. The tool can be used for pinching, grasping, and spreading motions. Furthermore, the thumb is "double jointed" so that the tool can be converted to a rake configuration to allow lifting motions. The initial prototype has been tested in a cadaver lab to demonstrate its utility.RESULTS:Our "lap-hand" was used to complete standard surgical tasks in a simulation device in a time comparable to open and laparoscopic approaches, including "bowel" manipulation and peg movement. Cadaver testing confirmed the ability to grasp, elevate, and move liver, stomach, colon, and small bowel in a fashion expected by the hand. No adverse events were noted, and no bowel injury or perforation resulted from over-grasping.CONCLUSIONS:We have designed, built, and tested a first prototype of an artificial hand for minimally invasive surgery. Use of such tools could both reduce the number of hand-incisions required and potentially transition more patients to undergo their abdominal procedures laparoscopically.
We have developed a rapid microfluidic method for antibiotic susceptibility testing in a stress-based environment. Fluid is passed at high speeds over bacteria immobilized on the bottom of a microfluidic channel. In the presence of stress and antibiotic, susceptible strains of bacteria die rapidly. However, resistant bacteria survive these stressful conditions. The hypothesis behind this method is new: stress activation of biochemical pathways, which are targets of antibiotics, can accelerate antibiotic susceptibility testing. As compared to standard antibiotic susceptibility testing methods, the rate-limiting step - bacterial growth - is omitted during antibiotic application. The technical implementation of the method is in a combination of standard techniques and innovative approaches. The standard parts of the method include bacterial culture protocols, defining microfluidic channels in polydimethylsiloxane (PDMS), cell viability monitoring with fluorescence, and batch image processing for bacteria counting. Innovative parts of the method are in the use of culture media flow for mechanical stress application, use of enzymes to damage but not kill the bacteria, and use of microarray substrates for bacterial attachment. The developed platform can be used in antibiotic and nonantibiotic related drug development and testing. As compared to the standard bacterial suspension experiments, the effect of the drug can be turned on and off repeatedly over controlled time periods. Repetitive observation of the same bacterial population is possible over the course of the same experiment.
Thyroid nodules are a frequent clinical finding and the most common endocrine malignancy is thyroid cancer. The standard of care in the management of a patient with a thyroid nodule is to perform a preoperative fine needle aspiration (FNA) biopsy of the suspect nodule under ultrasound imaging guidance. In a significant percentage of the cases, cytological assessment of the biopsy material yields indeterminate results, the consequence of which is diagnostic thyroidectomy. Unfortunately, 75–80% of diagnostic thyroidectomies following indeterminate cytology result in benign designation by post-surgery histopathology, indicating potentially unnecessary surgeries. Clearly, the potential exists for the improvement in patient care and the reduction of overall procedure costs if an improved preoperative diagnostic technique was developed. Elastic scattering spectroscopy (ESS) is an optical biopsy technique that is mediated by optical fiber probes and has been shown to be effective in differentiating benign from malignant thyroid tissue in ex vivo surgical tissue samples. The goal of the current research was to integrate the ESS fiber optic probes into a device that can also collect cells for cytological assessment and, thus, enable concurrent spectroscopic interrogation and biopsy of a suspect nodule with a single needle penetration. The primary challenges to designing the device included miniaturizing the standard ESS fiber optic probe to fit within an FNA needle and maintaining the needle’s aspiration functionality. We demonstrate the value of the fabricated prototype devices by assessing their preliminary performance in an on-going clinical study with >120 patients. The devices have proven to be clinically friendly, collecting both aspirated cells and optical data from the same location in thyroid nodules and with minimal disruption of clinical procedure. In the future, such integrated devices could be used to complement FNA-based cytological results and have the potential to both reduce the number of diagnostic thyroidectomies on benign nodules and improve the surgical approach for patients with thyroid malignancies, thereby, decreasing healthcare costs and improving patient outcomes.
Many new and exciting portable HIV viral load testing technologies are emerging for use in global medicine. While the potential to provide fast, isothermal, and quantitative molecular diagnostic information to clinicians in the field will soon be a reality, many of these technologies lack a robust front end for sample clean up and nucleic acid preparation. Such a technology would enable many different downstream molecular assays. Here, we present a portable system for centrifuge-free room temperature nucleic acid extraction from small volumes of whole blood (70 µL), using only thermally stable reagents compatible with storage and transport in low resource settings. Quantitative reverse transcriptase polymerase chain reaction (qRT-PCR) analysis of simulated samples demonstrate a lower limit of detection of 1000 copies/ml, with the ability to detect differences in viral load across four orders of magnitude. The system can also be used to store extracted RNA on detachable cartridges for up to one week at ambient temperature, and can be operated using only hand generated air pressure.
To accurately diagnose microbial infections in blood, it is essential to recover as many microorganisms from a sample as possible. Unfortunately, recovery of such microorganisms depends significantly on their adhesion to the surfaces of diagnostic devices. Consequently, we sought to minimize the adhesion of methicillin-sensitive Staphylococcus aureus (MSSA) to the surface of polypropylene-and acrylic-based bacteria concentration devices. These devices were treated with 11 different coatings having various charges and hydrophobicities. Some coatings promoted bacterial adhesion under centrifugation, whereas others were more likely to prevent it. Experiments were run using a simple buffer system and lysed blood, both inoculated with MSSA. Under both conditions, Hydromer's 7-TS-13 and Aqua 65JL were most effective in reducing bacterial adhesion.
Traditionally, bacterial pathogens in the blood have been identified using culture-based methods that can take several days to obtain results. This can lead to physicians making treatment decisions based on an incomplete diagnosis, which can increase the patient's risk of death. One major limitation to the development of faster diagnostic methods is that bacteria are found in very low concentrations in the blood, thus to detect them one either needs to increase their numbers by culturing the bacteria or effectively isolate and concentrate them from the blood. We are developing a device that purifies as few as 10 bacteria from 10 milliliters of whole blood, and concentrates the bacteria into a ∼30 microliter volume through a combination of preferential cell lysis and centrifugation steps. To enable the efficient capture of so few bacteria in a sea of billions of blood cells, the material properties of the device were optimized. Critical parameters include material selection, manufacturing method, surface roughness, and surface chemistry. In this paper, we present the design of this novel concentrator, optimization of these parameters, and the achieved performance.