Background: enhanced methods of therapeutic drug monitoring are required to support the individualisation of antibiotic dosing based on pharmacokinetics (PK) parameters. PK studies can be hampered by limited total serum volume, especially in neonates, or by sensitivity in the case of critically ill patients. We aimed to develop a liquid chromatography-mass spectrometry (LC/MS) analysis of benzylpenicillin, phenoxymethylpenicillin and amoxicillin in single low volumes of human serum and interstitial fluid (ISF) samples, with an improved limit of detection (LOD) and limit of quantification (LOQ), compared with previously published assays. Methods: sample clean-up was performed by protein precipitation using acetonitrile. Reverse phase chromatography was performed using triple quadrupole LC/MS. The mobile phase consisted of 55% methanol in water + 0.1% formic acid, with a flow rate of 0.4 mL min-1. Antibiotics stability was assessed at different temperatures. Results: chromatographic separation was achieved within 3 minutes for all analytes. Three common penicillins can now be measured in a single low-volume blood and ISF sample (15 μL) for the first time. Validation has demonstrated the method to be linear over the range 0.0015-10 mg L-1, with an accuracy of 93-104% and high sensitivity, with LOD ≈ 0.003 mg L-1 and LOQ ≈ 0.01 mg L-1 for all three analytes, which is critical for use in dose optimisation/individualisation. All evaluated penicillins indicated good stability at room temperature over 4 h, at (4 °C) over 24 h and at -80 °C for 6 months. Conclusion: the developed method is simple, rapid, accurate and clinically applicable for the quantification of three penicillin classes.
Electrochemical aptamer-based (E-AB) sensors using conformational change-induced electron transfer kinetics are sensitive, reagent-less, and cost-effective tools for molecular sensing. Current advances in this technology can allow continuous drug pharmacokinetic monitoring in living animals (Dauphin-Ducharme et al., ACS Sens 4(10):2832-2837, 2019; Idili et al., Chem Sci 10(35):8164-8170, 2019), as well as automated analysis of hormone pulsatility (Liang et al., Nat Commun 10(1):852, 2019). In this chapter, we provide the methodology for an automated E-AB conformational change-based robotic sensing platform. By using an open-source programmable robotic system, this method can be adapted to a wide range of experimental scenarios.
We demonstrate a novel and versatile sensing platform, based on electrolyte-gated graphene field-effect transistors, for easy, low-cost and scalable production of chemical sensor test strips. The Lab-on-PCB platform is enabled by low-boiling, low-surface-tension sprayable graphene ink deposited on a substrate manufactured using a commercial printed circuit board process. We demonstrate the versatility of the platform by sensing pH and Na+ concentrations in an aqueous solution, achieving a sensitivity of 143 ± 4 μA per pH and 131 ± 5 μA per log10Na+, respectively, in line with state-of-the-art graphene chemical sensing performance.
We report the development of a label-free, affinity-based impedimetric biosensor for the quantitative detection of interleukin-8 (IL-8) present in the nasal epithelial lining fluid (NELF). Early diagnosis of IL-8 in NELF samples enables prognosis of inflammatory respiratory disorders including asthma, chronic obstructive pulmonary disease, and adult respiratory distress syndrome. The study involves the fabrication of an electrochemical biosensor by immobilising polyclonal anti-IL-8 antibody on the anti-fouling zwitterionic hydrogel; polycarboxybetaine methacrylate (pCBMA). The immunosensor was characterised using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), vertical scanning interferometry (VSI) and scanning electron microscopy (SEM). Faradaic EIS measurements were conducted to explore the performance of the immunosensor via changes in charge transfer resistance. The sensor exhibited a good analytical performance in the detection and quantification of IL-8 in complex biological media. The biosensor showed a wide range of IL-8 detection, ranging from 55 fM to 55 nM with a 10 fM limit of detection (LOD). The biosensor showed a high selectivity to IL-8 and 90% reproducibility using untreated NELF samples, with 15-min time to result. These results provide a promising potential for multiplexing the cytokine platform for the profiling, diagnosis and clinical signaturing of associated respiratory disorders.
IntroductionDetermination of blood lactate levels supports decision-making in a range of medical conditions. Invasive blood-sampling and laboratory access are often required, and measurements provide a static profile at each instance. We conducted a phase I clinical study validating performance of a microneedle patch for minimally invasive, continuous lactate measurement in healthy volunteers.MethodsFive healthy adult participants wore a solid microneedle biosensor patch on their forearms and undertook aerobic exercise for 30 min. The microneedle biosensor quantifies lactate concentrations in interstitial fluid within the dermis continuously and in real-time. Outputs were captured as sensor current and compared with lactate concentrations from venous blood and microdialysis.ResultsThe biosensor was well-tolerated. Participants generated a median peak venous lactate of 9.25 mmol/L (IQR 6.73–10.71). Microdialysate concentrations of lactate closely correlated with blood. Microneedle biosensor current followed venous lactate concentrations and dynamics, with good agreement seen in all participants. There was an estimated lag-time of 5 min (IQR −4 to 11 min) between microneedle and blood lactate measurements.ConclusionThis study provides first-in-human data on use of a minimally invasive microneedle patch for continuous lactate measurement, providing dynamic monitoring. This low-cost platform offers distinct advantages to frequent blood sampling in a wide range of clinical settings, especially where access to laboratory services is limited or blood sampling is infeasible. Implementation of this technology in healthcare settings could support personalised decision-making in a variety of hospital and community settings.Trial registration numberNCT04238611.
Dopamine (DA), epinephrine (EP), and norepinephrine (NEP) are the main catecholamine of clinical interest, as they play crucial roles in the regulation of nervous and cardiovascular systems and are involved in some brain behaviors, such as stress, panic, anxiety, and depression. Therefore, there is an urgent need for a reliable sensing device able to provide their continuous monitoring in a minimally invasive manner. In this work, the first highly nanoporous gold (h-nPG) microneedle-based sensor is presented for continuous monitoring of catecholamine in interstitial fluid (ISF). The h-nPG microneedle-based gold electrode was prepared by a simple electrochemical self-templating method that involves two steps, gold electrodeposition and hydrogen bubbling at the electrode surface, realized by sweeping the potential between + 0.8 V and 0 V vs Ag/AgCl for 25 scans in a 10 mM HAuCl4 solution containing 2.5 M NH4Cl, and successively applying a fixed potential of - 2 V vs Ag/AgCl for 60 s. The resulting microneedle-based h-nPG sensor displays an interference-free total catecholamine detection expressed as NEP concentration, with a very low LOD of 100 nM, excellent sensitivity and stability, and fast response time (< 4 s). The performance of the h-nPG microneedle array sensor was successively assessed in artificial ISF and in a hydrogel skin model at typical physiological concentrations.
Microneedle arrays for minimally invasive continuous sensing in the dermal interstitial fluid (ISF) have been demonstrated in both amperometric and potentiometric modes, however there are no publication where microneedle arrays have been modified with lignin nanoparticles. Lignin, the most abundant polyphenol in nature, is the main byproduct in the pulp and paper manufacturing industry and biorefinery. Lignin nanoparticles (LNPs), easily produced by green methods, offer unique properties and have therefore gained interest for electrode modification. In this work, we have developed a novel green LNPs modified microneedles electrode platform for pain free continuous monitoring of glucose in artificial interstitial fluid (ISF). The gold surface of the microneedles has been modified with LNPs and electrochemically characterized. Functionalization with glucose oxidase enzyme and with an Osmium polymer as redox mediator allowed the continuous monitoring of glucose. The performance of the LNPs/microneedle biosensor for glucose detection was assessed in artificial interstitial fluid and in human serum, both spiked with glucose. The results reveal that the new LNPs microneedles biosensor holds interesting promise for the development of biocompatible, wearable, real-time monitoring devices to be used in clinical care and sport medicine. The proposed LNPs microneedles platform can be applied also for the detection of other important bioanalytes (such as lactate, hormones, etc).
Lipoic acid–gold nanoconjugates (GNPs–LA) decrease GNPs–α-synuclein-induced oxidative stress on living cells, making them a promising antioxidant system for the treatment of Parkinson's disease.
Although RNA aptamers can show comparable or better specificity and affinity to antibodies and have the advantage of being able to access different live cell compartments, they are often much less stable in vivo. We report here the first aptamer that binds human retinoblastoma protein (RB) and is stable in live cells. RB is both a key protein in cell cycle control and also a tumour suppressor. The aptamer was selected from an RNA library against a unique 12-residue helical peptide derived from RB rather than the whole protein molecule. It binds RB with high affinity (Kd = 5.1 ± 0.1 nM) and is a putative RNA G-quadruplex structure formed by an 18-nucleotide sequence (18E16 - GGA GGG UGG AGG GAA GGG), which may account for its high stability. Confocal fluorescence microscopy of live cells transfected with the aptamer shows it is stable intracellularly and efficient in entering the nucleus where an analogous antibody was inaccessible. The findings demonstrate this aptamer is an advanced probe for RB in live cell applications.
Endoscopy is the gold standard investigation in the diagnosis of gastrointestinal cancers and the management of early and pre-malignant lesions either by resection or ablation. Recently gold nanoparticles have shown promise in cancer diagnosis and therapeutics (theranostics). The combination of multifunctional gold nanoparticles with near infrared fluorescence endoscopy for accurate mapping of early or pre-malignant lesions can potentially enhance diagnostic efficiency while precisely directing endoscopic near infrared photothermal therapy for established cancers. The integration of endoscopy with near infrared fluorescence imaging and photothermal therapy was aided by the accumulation of our multifunctionalized PEG-GNR-Cy5.5-anti-EGFR-antibody gold nanorods within gastrointestinal tumor xenografts in BALB/c mice. Control mice (with tumors) received either gold nanorods or photothermal therapy, while study mice received both treatment modalities. Local (tumor-centric) and systemic effects were examined for 30 days. Clear endoscopic near infrared fluorescence signals were observed emanating specifically from tumor sites and these corresponded precisely to the tumor margins. Endoscopic fluorescence-guided near infrared photothermal therapy successfully induced tumor ablations in all 20 mice studied, with complete histological clearance and minimal collateral damage. Multi-source analysis from histology, electron microscopy, mass spectrometry, blood, clinical evaluation, psychosocial and weight monitoring demonstrated the inherent safety of this technology. The combination of this innovative nanotechnology with gold standard clinical practice will be of value in enhancing the early optical detection of gastrointestinal cancers and a useful adjunct for its therapy.
In this paper, we present the first highly porous gold (h-PG) microneedles-based second-generation biosensor for minimally invasive monitoring of glucose in artificial interstitial fluid (ISF). A highly porous microneedles-based electrode was prepared by a simple electrochemical self-templating method that involves two steps, gold electrodeposition and hydrogen bubbling at the electrode, which were realized by applying a potential of −2 V versus a saturated calomel electrode (SCE). The highly porous gold surface of the microneedles was modified by immobilization of 6-(ferrocenyl)hexanethiol (FcSH) as a redox mediator and subsequently by immobilization of a flavin adenine dinucleotide glucose dehydrogenase (FAD-GDH) enzyme using a drop-casting method. The microneedles-based FcSH/FAD-GDH biosensor allows for the detection of glucose in artificial interstitial fluid with an extended linear range (0.1–10 mM), high sensitivity (50.86 µA cm−2 mM−1), stability (20% signal loss after 30 days), selectivity (only ascorbic acid showed a response about 10% of glucose signal), and a short response time (3 s). These properties were favourably compared to other microneedles-based glucose biosensors reported in the literature. Finally, the microneedle-arrays-based second-generation biosensor for glucose detection was tested in artificial interstitial fluid opportunely spiked with different concentrations of glucose (simulating healthy physiological conditions while fasting and after lunch) and by placing the electrode into a simulated chitosan/agarose hydrogel skin model embedded in the artificial ISF (continuous glucose monitoring). The obtained current signals had a lag-time of about 2 min compared to the experiments in solution, but they fit perfectly into the linearity range of the biosensor (0.1–10 mM). These promising results show that the proposed h-PG microneedles-based sensor could be used as a wearable, disposable, user-friendly, and automated diagnostic tool for diabetes patients.
Theranostics involves finding the biomarkers of a disease, fighting them through site specific drug delivery and following them for prognosis of the disease. Microneedle array technology has been used for drug delivery and extended for continuous monitoring of analytes present in the skin compartment. We envisage the use of microneedle arrays for future theranostic applications. The potential of combining microneedle array-based drug delivery and diagnostics as part of closed-loop control system for the management of diseases and delivery of precision drugs in individual patients is reported in this paper.
Compared with therapeutics, diagnostic devices account for a relatively small proportion of healthcare expenditure (less than 10%) and yet timely diagnosis as well as continuous monitoring of molecular markers can have a major impact on disease outcomes. In particular point of care (or near patient) tests can empower individuals to become active participants in the management of their conditions, giving them and their medical support greater insight into both their conditions and their response to treatment. In an extension of the point of care paradigm, continuous monitors of biomarkers and/or therapeutics allow high frequency data to be gathered and patterns of variation to be analyzed in ways that are not possible with infrequent and sporadic testing. The advent of novel materials, fabrication methods and data analysis have opened the way to new devices, assay formats and molecular targets. In this paper we will discuss some aspects of our work in this area with a particular focus on microneedles for continuous, minimally invasive sensing and the use of nucleic acid aptamers in both electrochemical and lateral flow assays.
The capability of the crude extract of Rhodococcus UKMP-5M was enhanced by adopting the technology of immobilization. Among the matrices screened to encapsulate the crude extract, gellan gum emerged as the most suitable immobilization material, exceeding the activity of cyanide-degrading enzyme by 61% and 361% in comparison to alginate carrier and non-immobilized crude extract, respectively. Improved bead mechanical strength which supported higher biocatalyst activity by 63% was observed when concentration of gellan gum, concentration of calcium chloride, number of beads and bead size were optimized. The immobilized crude extract demonstrated higher tolerance towards broad range of pH (5-10) and temperature (30°C-40°C), superior cyanide-degrading activity over time and improved storage stability by maintaining 76% of its initial activity after 30 days at 4°C. Furthermore, repeated use of the gellan gum beads up to 20 batches without substantial loss in the catalytic activity was documented in the present study, indicating that the durability of the beads and the stability of the enzyme are both above adequate. Collectively, the findings reported here revealed that the utilization of the encapsulated crude extract of Rhodococcus UKMP-5M can be considered as a novel attempt to develop an environmentally favourable and financially viable method in cyanide biodegradation.
In article number 1804798, Max Grell, Firat Guder, and co-workers describe a method for depositing a wide range of metals inside fabrics which they call Si ink-enabled autocatalytic metallization. Without requiring surface modification, the method provides access to devices as diverse as antennas, batteries, biosensors, or Raman spectroscopy substrates. Future research might bring many more applications for this highly adaptable method.
The first example of an octadentate gadolinium unit based on DO3A (hydration number q=1) with a dithiocarbamate tether has been designed and attached to the surface of gold nanoparticles (around 4.4 nm in diameter). In addition to the superior robustness of this attachment, the restricted rotation of the Gd complex on the nanoparticle surface leads to a dramatic increase in relaxivity (r1 ) from 4.0 mm-1 s-1 in unbound form to 34.3 mm-1 s-1 (at 10 MHz, 37 °C) and 22±2 mm-1 s-1 (at 63.87 MHz, 25 °C) when immobilised on the surface. The one-pot synthetic route provides a straightforward and versatile way of preparing a range of multifunctional gold nanoparticles. The incorporation of additional surface units for biocompatibility (PEG and thioglucose units) and targeting (folic acid) leads to little detrimental effect on the high relaxivity observed for these non-toxic multifunctional materials. In addition to the passive targeting attributed to gold nanoparticles, the inclusion of a unit capable of targeting the folate receptors overexpressed by cancer cells, such as HeLa cells, illustrates the potential of these assemblies.
Biomaterial substrates can be engineered to present topographical signals to cells which, through interactions between the material and active components of the cell membrane, regulate key cellular processes and guide cell fate decisions. However, targeting mechanoresponsive elements that reside within the intracellular domain is a concept that has only recently emerged. Here, we show that mesoporous silicon nanoneedle arrays interact simultaneously with the cell membrane, cytoskeleton, and nucleus of primary human cells, generating distinct responses at each of these cellular compartments. Specifically, nanoneedles inhibit focal adhesion maturation at the membrane, reduce tension in the cytoskeleton, and lead to remodeling of the nuclear envelope at sites of impingement. The combined changes in actin cytoskeleton assembly, expression and segregation of the nuclear lamina, and localization of Yes-associated protein (YAP) correlate differently from what is canonically observed upon stimulation at the cell membrane, revealing that biophysical cues directed to the intracellular space can generate heretofore unobserved mechanosensory responses. These findings highlight the ability of nanoneedles to study and direct the phenotype of large cell populations simultaneously, through biophysical interactions with multiple mechanoresponsive components.
Commercially available metal inks are mainly designed for planar substrates (for example, polyethylene terephthalate foils or ceramics), and they contain hydrophobic polymer binders that fill the pores in fabrics when printed, thus resulting in hydrophobic electrodes. Here, a low-cost binder-free method for the metallization of woven and nonwoven fabrics is presented that preserves the 3D structure and hydrophilicity of the substrate. Metals such as Au, Ag, and Pt are grown autocatalytically, using metal salts, inside the fibrous network of fabrics at room temperature in a two-step process, with a water-based silicon particle ink acting as precursor. Using this method, (patterned) metallized fabrics are being enabled to be produced with low electrical resistance (less than 3.5 Ω sq-1). In addition to fabrics, the method is also compatible with other 3D hydrophilic substrates such as nitrocellulose membranes. The versatility of this method is demonstrated by producing coil antennas for wireless energy harvesting, Ag-Zn batteries for energy storage, electrochemical biosensors for the detection of DNA/proteins, and as a substrate for optical sensing by surface enhanced Raman spectroscopy. In the future, this method of metallization may pave the way for new classes of high-performance devices using low-cost fabrics.
ABSTRACT In the present study, locally isolated Rhodococcus strains were attempted as biological tools for methyl red removal, a mutagenic azo dye posing threat to the environment if left untreated. Rhodococcus strain UCC 0016 demonstrated superior methyl red-decolourizing activity of 100% after 24 h at static condition in comparison to Rhodococcus strain UCC 0008 which recorded 65% decolourization after 72 h. Optimization of physicochemical parameters at 30°C, pH 7 and supplementing glucose as the carbon source resulted in improved methyl red-decolourizing activity at static condition and reduced the time taken to achieve complete decolourization by 80%. Higher concentration of methyl red (5 g/L) was able to be decolourized completely within 10 h by adopting the technology of immobilization. The encapsulated cells of Rhodococcus strain UCC 0016 demonstrated higher substrate affinity (Km = 0.6995 g/L) and an accelerated rate of disappearance of methyl red (Vmax = 0.3203 g/L/h) compared to the free cells. Furthermore, the gellan gum beads could be reused up to nine batches without substantial loss in the catalytic activity indicating the economic importance of this protocol. Analysis of methyl red degradation products revealed no germination inhibition on Triticum aestivum and Vigna radiata demonstrating complete toxicity removal of the parent dye after biological treatment. The occurrence of new and altered peaks (UV–Vis and FTIR) further supported the notion that the removal of methyl red by Rhodococcus strain UCC 0016 was indeed through biodegradation. Therefore, this strain has a huge potential as a candidate for efficient bioremediation of wastewater containing methyl red. GRAPHICAL ABSTRACT
The performance of a Malaysian isolated strain, Rhodococcus UKMP-5M in remediating nitriles was evaluated. Biotransformation of acrylonitrile by resting cells of Rhodococcus UKMP-5M as biocatalyst was performed. The reaction conditions in biotransformation of acrylonitrile were optimized by varying parameters. The optimal biotransformation reaction was of 30oC, 2 house of reaction, agitation at 80 rpm, pH 6 of initial pH of phosphate buffer solution and 5% v/v of resting cells. Other factors affecting biotransformation was also evaluated. It showed that the strain has higher affinity towards longer chain of aliphatic and aromatic nitriles and amides; good tolerance of high concentrations of acrylonitrile (150-200 mM) as well a good thermal stability (50 and 60°C for 3 hours and 40°C for 5 hours). It suggested that Rhodococcus UKMP-5M has a potential as biocatalyst in remediating nitriles.