Medication errors are common at the time of administration. To prevent them, technologies allowing consistency check by bar code technology at bedside have been developed. Our study focuses on the evaluation of a BarCode Medication Administration (BCMA) called EASYSCAN with Electronic Medication Administration Record (e-MAR) to verify both patient's identity and medication to be administrated.A prospective observational study was conducted during seven weeks in a French medicine ward. The performance of the system was evaluated by the success rate of BCMA and by the average time for administration with and without EASYSCAN. A satisfaction questionnaire about BCMA was proposed to nurses.We observed 182 administrations including 87 (48%) with EASYSCAN. The verification of the patient's identity was successful in 77% of administrations and 65% of the drugs were scanned successfully. The main causes of check failures were the lack of datamatrix on the drug (81%), error messages (14%) and the lack of system functionality (5%). The average time for administration per patient was significantly increased: 4.68min/patient with versus 2.87min/patient without EASYSCAN.The study shows the EASYSCAN's performance in its first version. Material and software evolutions and an increase of nurses'pratices will be necessary to continue the experimentation of this system still unpublished in France.
objectives. - Medication errors are common at the time of administration. To prevent them, technologies allowing consistency check by bar code technology at bedside have been develo-ped. Our study focuses on the evaluation of a BarCode Medication Administration (BCMA) called EASYSCAN with Electronic Medication Administration Record (e-MAR) to verify both patient's identity and medication to be administrated.Methods. - A prospective observational study was conducted during seven weeks in a French medicine ward. The performance of the system was evaluated by the success rate of BCMA and by the average time for administration with and without EASYSCAN. A satisfaction questionnaire about BCMA was proposed to nurses.Results. - We observed 182 administrations including 87 (48%) with EASYSCAN. The verifica-tion of the patient's identity was successful in 77% of administrations and 65% of the drugs were scanned successfully. The main causes of check failures were the lack of datamatrix on the drug (81%), error messages (14%) and the lack of system functionality (5%). The average time for administration per patient was significantly increased: 4.68 min/patient with versus 2.87 min/patient without EASYSCAN.Conclusions. - The study shows the EASYSCAN's performance in its first version. Material and software evolutions and an increase of nurses'pratices will be necessary to continue the expe-rimentation of this system still unpublished in France.(c) 2021 Academie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.
Medication errors (ME) are frequently encountered and present at every step of the therapeutic process. This study's aims were to take stock of the ME reported to the region's pharmacovigilance (CRPV) and poison control centers (CAPTV) and to identify potential regional actions. A 2-months (January and February 2017) prospective gathering of the calls to the CAPTV regarding the ME and of the ME declarations to the region's CRPV (Clermont-Ferrand, Grenoble, Lyon, Saint-Etienne) has been carried out. The place of occurrence, the event's description and its consequences and data regarding the patient were collected. In addition to that, the regional drug observatory OMEDIT analysis has allowed to determine the ME's types (REMED characterization, never event?) and to took for the results of a potential thorough analysis. The study reported 580 calls for 590 ME and 583 patients. ME mostly affected the ambulatory/domicile sector (76%), the medico-social sector (14%) and the healthcare facilities sector (7%). It usually was about dose errors, medication errors and patient errors with a different profile in each sector. The majority of errors (85%) occurred at the administration step. Almost all the observed ME were confirmed errors having reached the patient (99.5%) but only a few had serious consequences. One out of 5 ME was eligible for a thorough analysis but even less were subjected to that kind of analysis. The main never event concerned the unidose in the ambulatory sector. The health products involved were mostly a single medication (75%) and then the patient's full treatment (12%). The CRPV/CAPTV/OMEDIT's skills are complementary for the gathering, the analysis and the management of the ME. Training campaigns and support are to be considered for the professionals and especially within the medico-social facilities. (C) 2019 Societe francaise de pharmacologie et de therapeutique. Published by Elsevier Masson SAS. All rights reserved.