The aim of our work was to investigate practical and robust methods for the electrochemical analysis of DNT. Using gold WEs, we differentiated between the nitro substituents in 2,4- and 2,6-DNT in organic electrolyte systems. Switching to an aqueous electrolyte (2 M H2SO4), a limit of detection (LOD) of 0.158 ppm (0.87 μM) and a limit of quantitation (LOQ) of 0.48 ppm (2.64 μM) were observed for 2,4-DNT. Subsequent simplification to wooden craft pencils as WEs in aqueous 2 M H2SO4 electrolyte achieved a LOD of 4.8 ppm (26.48 μM) and a LOQ of 14.6 ppm (80.54 μM) for 2,4-DNT. Alongside this easily renewable WE choice, 2 M H2SO4 was found to improve the solubility of DNT in aqueous media and has not been previously reported as an electrolyte in DNT electroanalysis. On testing a range of pencil grades from 4H to 8B, it was found that 4B gave the best sensitivity. The work serves as a preliminary study into materials that, through their simplicity and availability, may be suitable for the development of a robust and portable instrumental method through the electrochemical work presented here.
Laser-induced breakdown spectroscopy (LIBS) and principal component analysis (PCA) are frequently used for analytical purposes in research and industry, but they seldom are part of the chemistry curriculum or laboratory exercises. This case study paper describes the combined application of LIBS and PCA during a research internship for an undergraduate student. The instructional method applied was based on a one-on-one mentorship, in which case the learner was engaged in a research work. The learning activities included theoretical introductions to the LIBS and PCA methods, numerical simulation, experiments, and data analysis. The study covered three main topics: analysis of LIBS spectra, application of PCA for clustering, and use of PCA for experimental design. The realization of the study was instructive for all parties involved: from the mentorship point of view, it is concluded that the topics can be covered during an internship or developed into a one semester long research-based module of a chemistry program or a final year project. The student, on the other hand, developed profound technical skills in performing experiments and using PCA software for data analysis.
We are demonstrating robust, single-layer ion-selective electrode (ISE) utilizing simple Ag/AgCl electrode as solid support without the need for intermediate polymer layer. We have created and chemically linked a family of imidazolium ionic liquids (ILs) with poly (vinyl chloride) (PVC) using click chemistry, resulting in hybrid materials with tunable characteristics. The resultant material inherently contains chloride ion thus offering the ability to stabilize interfacial potential. This allowed us to construct very simple, single-layer membranes with significantly reduced need for conditioning as an added bonus compared to traditional sensors. Chemical immobilization of ISE membrane components also led to extended lifetime as the potential for material loss is reduced and detection limits are lowered. In our characterization we focused on perchlorate as a model ion. It's levels of around 10(-7)M could be repeatedly quantified over a 100day period despite constant exposure of ISEs to aqueous solution over this time. Most importantly, the electrodes exhibited stable and reproducible signal with significantly simplified pre- and post-operation handling protocols. This offers potential for insitu applications as well as to advanced fabrication techniques and miniaturization. Simplicity of construction and operation, and low cost of the solid substrate allows for disposable ISE formats.
Molecular-logic based computation (MLBC) has grown by accumulating many examples of combinational logic gates and a few sequential variants. In spite of many inspirations being available in biology, there are virtually no examples of MLBC in chemistry where sequential and combinational operations are integrated. Here we report a simple alcohol-ketone redox interconversion which switches a macrocycle between a large or small cavity, with erect aromatic walls which create a deep hydrophobic space or with collapsed walls respectively. Small aromatic guests can be captured or released in an all or none manner upon chemical command. During capture, the fluorescence of the alcohol macrocycle is quenched via fluorescent photoinduced electron transfer switching, meaning that its occupancy state is self-indicated. This represents a chemically-driven RS Flip-Flop, one of whose outputs is fed into an INHIBIT gate. Processing of outputs from memory stores is seen in the injection of packaged neurotransmitters into synaptic clefts for onward neural signalling. Overall, capture-release phenomena from discrete supermolecules now have a Boolean basis.
This paper details a miniaturised, solid state ion-selective electrode selective for diclofenac. The sensor comprises a novel ionic liquid electroactive material - an imidazolium-diclofenac ion associate. The ion associate is present in a plasticised poly(vinyl chloride) (PVC) membrane on planar carbon electrodes, with an intermediate poly(3,4-ethylenedioxythiophene) layer. The sensitivity and selectivity of the sensor were determined using chronopotentiometric methods. In response to diclofenac, a slope of -53.3 +/- 3.6mV/dec was observed. A limit of detection of 2.90 x 10(-3)g L-1 is reported, with a linear range of 3.18 x 10(-3)g L-1 to 3.18g L-1. The sensors show good selectivity towards diclofenac against pertinent interferent molecules, with a response time of <15s.
Novel solid-contact iodide-selective electrodes based on covalently attached 1,2,3 triazole ionic liquid (IL) were prepared and investigated in this study. Triazole-based IL moieties were synthesized using click chemistry and were further copolymerized with lauryl methacrylate via a simple one-step free radical polymerization to produce a "self-plasticized" copolymer. The mechanical properties of the copolymer are suitable for the fabrication of plasticizer-free ion-selective membrane electrodes. We demonstrate that covalently attached IL moieties provide adequate functionality to the ion-selective membrane, thus achieving a very simple, one-component sensing membrane. We also demonstrate that the presence of iodide as the counterion in the triazole moiety has direct influence on the membrane's functionality. Potentiometric experiments revealed that each electrode displays high selectivity toward iodide anions over a number of inorganic anions. Moreover, the inherent presence of the iodide in the membrane reduces the need for conditioning. The nonconditioned electrodes show strikingly similar response characteristics compared to the conditioned ones. The electrodes exhibited a near Nernstian behavior with a slope of -56.1 mV per decade across a large concentration range with lower detection limits found at approximately 6.3 × 10(-8) M or 8 ppb. These all-solid-state sensors were utilized for the selective potentiometric determination of iodide ions in artificial urine samples in the nanomolar concentration range.
The applicability of ion exchange membranes is mainly defined by their permselectivity towards specific ions. For instance, the needed selectivity can be sought by modifying some of the components required for the preparation of such membranes. In this study, a new class of materials –trihexyl(tetradecyl)phosphonium based ionic liquids (ILs) were used to modify the properties of ion exchange membranes. We determined selectivity coefficients for iodide as model ion utilizing six phosphonium-based ILs and compared the selectivity with two classical plasticizers. The dielectric properties of membranes plasticized with ionic liquids and their response characteristics towards ten different anions were investigated using potentiometric and impedance measurements. In this large set of data, deviations of obtained selectivity coefficients from the well-established Hofmeister series were observed on many occasions thus indicating a multitude of applications for these ion-exchanging systems.
Polyaniline (PAni) is an example of a conducting polymer that can be switched between an insulating and a conductive state. This switching is accompanied by a colour change. Recently, interest has developed in the nanofibre form of PAni as these low dimensional structures have a very high surface area, thus enabling a faster response time. We investigate how the surface chemistry of these nanofibres can be modified by covalently attaching functional side-groups. In particular, we demonstrate the attachment of both amide and carboxylic acid groups. This can be achieved using a simple reflux technique. The modified material retains its nanomorphology and the intrinsic electrochemical, spectroscopic and redox properties of PAni are also preserved. Both acid and amine side-groups are interesting in that they provide a template, which could be further altered to enhance the selectivity of PAni. Acid terminated chains can also be used to introduce self-doping behaviour to PAni.
We report a new method for the real-time quantitative analysis of sodium in human sweat, consolidating sweat collection and analysis in a single, integrated, wearable platform. This temporal data opens up new possibilities in the study of human physiology, broadly applicable from assessing high performance athletes to monitoring Cystic Fibrosis (CF) sufferers. Our compact Sodium Sensor Belt (SSB) consists of a sodium selective Ion Selective Electrode (ISE) integrated into a platform that can be interfaced with the human body during exercise. No skin cleaning regime or sweat storage technology is required as the sweat is continually wicked from the skin to a sensing surface and from there to a storage area via a fabric pump. Our results suggest that after an initial equilibration period, a steady-state sodium plateau concentration was reached. Atomic Absorption Spectroscopy (AAS) was used as a reference method, and this has confirmed the accuracy of the new continuous monitoring approach. The steady-state concentrations observed were found to fall within ranges previously found in the literature, which further validates the approach. Daily calibration repeatability (n = 4) was +/- 3.0% RSD and over a three month period reproducibility was +/- 12.1% RSD (n = 56). As a further application, we attempted to monitor the sweat of Cystic Fibrosis (CF) sufferers using the same device. We observed high sodium concentrations symptomatic of CF (similar to 60 mM Na(+)) for two CF patients, with no conclusive results for the remaining patients due to their limited exercising capability, and high viscosity/low volume of sweat produced.
Quality control (QC) measures are less prevalent in teaching laboratories than commercial settings possibly owing to a lack of commercial incentives or teaching resources. This article focuses on the use of QC assessment in the analytical techniques of high performance liquid chromatography (HPLC) and ultraviolet–visible spectroscopy (UV–vis) at undergraduate and master’s level. Data were collected over 2 semesters and the use of limits generated by staff were compared to the limits based on student data. This comparison enabled us to balance the learning of practical laboratory skills with providing sufficient incidences requiring troubleshooting and discussion on quality within the class. The QC limits chosen do not necessarily follow the perceived difficulty of an instrumental procedure. Staff-generated limits proved the most useful for the HPLC experiment, while broader student-based limits were deemed necessary for the simpler UV–vis experiment. Corrected calculations and computer templates were used in later QC charts as calculation errors were found to overshadow the identification of laboratory errors. The unique QC limits for any instrumental practical can be established and fine tuned in the same way as in the examples illustrated here.
This paper details the development of a textile based fluid handling system with integrated wireless biochemical sensors. Such research represents a new advancement in the area of wearable technologies. The system contains pH, sodium and conductivity sensors. It has been demonstrated during on-body trials that the pH sensor has close agreement with measurements obtained using a reference pH probe. Initial investigations into the sodium and conductivity sensors have shown their suitability for integration into the wearable system. It is thought that applications exist in personal health and sports performance and training.
In the crystal structure of the title compound, C(19)H(17)Cl(2)NO, the indoline and benzopyran ring systems are approximately perpendicular to each other. The indoline ring is in an envelope conformation with the spiro C atom as the flap. The N atom of the indoline ring forms a pyramidal environment, the sum of the angles at this atom being 352.46°.
An entry from the Cambridge Structural Database, the world’s repository for small molecule crystal structures. The entry contains experimental data from a crystal diffraction study. The deposited dataset for this entry is freely available from the CCDC and typically includes 3D coordinates, cell parameters, space group, experimental conditions and quality measures.
Textile based devices for biochemical analysis of body fluids represent a new development in the area of wearable sensors. This paper outlines the development of a fluid handling system and wireless sensors for the real-time analysis of sweat pH and sodium levels during exercise. Liquid is drawn into the system using a moisture wicking material and passive pump. The sensor then displays pH induced colorimetric changes, which are recorded using an optical detection system. The device has been tested under laboratory conditions and can easily detect increments of 0.2 pH units. At present, changes in sodium content are determined using a specially constructed classic ion selective electrode and reference electrode, combined to form a single probe. This is placed in contact with the fabric of the fluid handling system in order to obtain a real-time potentiometric sodium measurement. Both devices have successfully been used for the investigation of sweat composition during on-body trials.
In the crystal structure of the title compound, C19H17Cl2NO, the indoline and benzopyran ring systems are approximately perpendicular to each other. The indoline ring is in an envelope conformation with the spiro C atom as the flap. The N atom of the indoline ring forms a pyramidal environment, the sum of the angles at this atom being 352.46°.
A wearable fluid handling platform based on polyamide lycra has been developed for non-invasive, real-time biochemical analysis of bodily fluids. Main challenges include sample collection and delivery, sensor integration and waste sample handling. The system is able to collect sweat as it is expired through the skin and transports it through a channel defined in the fabric using a hydrophobic membrane. A superabsorbent material is placed at the end of the channel to provide continuous sample delivery and storage. A colorimetric sensor is fabricated directly on the textile channel to determine the changes in sweat pH. This is coupled with a wireless optical sensor integrated into the cover of the fluidic platform to measure colour change. Sodium and conductivity sensors have also been developed. This textile based sensing system has applications in personal health and for the analysis of sports performance and training.
Textile based sensors which can be used to measure the chemical composition of bodily fluids represents a major advancement in the area of wearable technology. BIOTEX is an EU funded project aiming to develop such sensors with a particular interest in monitoring perspiration. A textile based fluid handling system has been developed for sample collection and transport. Sodium, conductivity and pH sensors have also been developed. This paper details the integration and testing of these sensors. Results show that the developed system can collect and analyze sweat in real time during exercise and transmit this data wirelessly to a remote receiver.
Urea - calix[ 4] arenes 1 and 2 were synthesised and incorporated into ISE membranes for assessment as sensors for inorganic anions in water. 1 revealed a strong response to all anions following the Hofmeister selectivity order. For ISEs of 2, the response to a portion of the anion series was suppressed, increasing the margin of selectivity of nitrate over chloride, a common interferant of nitrate in fresh and marine water samples. The performance of ISEs containing 2 was compared to commercially available alkylammonium nitrate ion-exchange salts used for nitrate sensing. Our ISEs performed favourably in terms of sensitivity, linear range and LOD with an improved selectivity coefficient over chloride of log K-NO3 (Cl) (pot) of - 3.4, an order of magnitude better than commercially available nitrate ISEs. The pre-conditioning of ISEs in non-primary chloride salt was essential for obtaining these results.
We report both the preparation and sensor evaluation of a new metal-free calixarene bridged binuclear phthalocyanine.
A neutral 2-site chloride selective compound has been developed (3), based on a 1,3-alternate tetrasubstituted calix[4]arene providing a preorganized supramolecular scaffold. The resultant supramolecular cavity is among the first to combine urea functional groups bridged with single methylene spacers to pyrene moieties. It combines a naturally and synthetically proven H-bonding system with the elegant ratiometric fluorescent signaling properties of an intramolecular pyrene excimer system, triggered by conformational changes upon anion coordination. The excimer emission of 3 is quenched, with a simultaneous rise in the monomer emission solely by the chloride anion among a wide variety of anions tested. 3 has an association constant of 2.4 x 10(4) M(-1) with chloride. The suitability and advantages of ratiometric optical sensor compounds like 3 for use in practical sensor devices is discussed. 3 has an LOD of 8 x 10(-6) M with chloride in acetonitrile-chloroform (95:5 v/v). A dynamic fluorescence study revealed a response time of < 3 s. A recently developed and simple HPLC-based purification method complimented conventional organic work up methods to yield pure product.