Minor shoot injury significantly (P < 0.05) increased the level at which Salmonella enterica serovar Sofia persisted on cos lettuce in the greenhouse. Initial mean counts of the Salmonella on the injured and uninjured cos lettuce were on the order of 6 log CFU/g. After 3 days, the mean count decreased to 4.8 log CFU/g on the injured plants compared with the significantly (P < 0.05) smaller count of 3.4 log CFU/g on the uninjured plants. By the end of the 3-week experiment, the count from the injured plants was 2.9 log CFU/g compared with a count of below the level of detection from the uninjured plants. A similar pattern of bacterial persistence was observed on injured versus uninjured plants by using Listeria innocua on cos lettuce and S. enterica serovar Sofia on chive. The findings reaffirm earlier results with Escherichia coli and increase the impetus to avoid shoot injury during the production of cos lettuce and chive, if bacteria of food safety concern are present.
Previous studies defined easy and difficult to hydrolyze fractions of hemicellulose that may result from bonds among cellulose, hemicellulose, and lignin. To understand how such bonds affect hydrolysis, Populus trichocarpa × Populus deltoides, holocellulose isolated from P. trichocarpa × P. deltoides and birchwood xylan were subjected to hydrothermal flow-through pretreatment. Samples were characterized by glycome profiling, HPLC, and UPLC-MS. Glycome profiling revealed steady fragmentation and removal of glycans from solids during hydrolysis. The extent of polysaccharide fragmentation, hydrolysis rate, and total xylose yield were lowest for P. trichocarpa × P. deltoides and greatest for birchwood xylan. Comparison of results from P. trichocarpa × P. deltoides and holocellulose suggested that lignin-carbohydrate complexes reduce hydrolysis rates and limit release of large xylooligomers. Smaller differences between results with holocellulose and birchwood xylan suggest xylan-cellulose hydrogen bonds limited hydrolysis, but to a lesser extent. These findings imply cell wall structure strongly influences hydrolysis.
Sodium and potassium cyanide are highly toxic, produced in large amounts by the chemical industry, and linked to numerous high-profile crimes. The U.S. Centers for Disease Control and Prevention has identified cyanide as one of the most probable agents to be used in a chemical terrorism event. We investigated whether stable C and N isotopic content of sodium and potassium cyanide could serve as a forensic signature for sample matching, using a collection of 65 cyanide samples. Upon analysis, a few of the cyanide samples displayed nonhomogeneous isotopic content associated with degradation to a carbonate salt and loss of hydrogen cyanide. Most samples had highly reproducible isotope content. Of the 65 cyanide samples, >95% could be properly matched based on C and N isotope ratios, with a false match rate <3%. These results suggest that stable C and N isotope ratios are a useful forensic signature for matching cyanide samples.
Minor shoot injury to glasshouse celery, Cos lettuce and chive plants significantly increased the persistence of applied Escherichia coli (P<0.05). After 1 week, mean counts of about 5 log(10) CFU/g decreased to fewer than 0.5 log(10) CFU/g on the uninjured plants, compared to 4 log(10) CFU/g or more on injured plants. By the end of the 3-week long experiments, counts from the uninjured plants were 0.21 log(10) CFU/g or fewer, but 2.8, 2.3 and 5.1 log(10) CFU/g on injured Cos lettuce, celery and chive plants, respectively. A field experiment using Cos lettuce also showed that shoot injury increased E. coli persistence. Counts from the injured plants on days 1, 3, and 7 were, 4.2, 4.1 and 3.3 log(10) CFU/g, respectively, whereas the uninjured plants returned significantly (P<0.05) lower counts on those days, and were 2.8, 2.0 and 1.2 log(10) CFU/g, respectively. These findings reveal that increased E. coli persistence on injured tissue is common to different vegetables and can occur in the glasshouse and the field. The implications of this study on vegetable production practices are presented.
Carrots are one of the highest dietary sources of beta-carotene and are naturally high in the (all-E)-beta-carotene isomer, which has higher bioavailability, provitamin A activity, and antioxidant capacity compared to Z (cis) isomers. The objectives of the present study were to investigate the effects of storage temperature, time, and cooking (boiling for 15 min) on the levels of carotene isomers in 'Stefano' carrots. Storing carrots at either 4 degrees C to simulate long-term storage or 20 degrees C to simulate marketing practices resulted in increases in (all-E)-beta-carotene of 20.3% after 3 days at 4 degrees C and 34.4% after 14 days at 20 degrees C, respectively. The levels of Z isomers in raw carrots were low with (13Z)-beta-carotene and (9Z)-beta-carotene accounting for less that 1.8% of the total beta-carotene present. Levels of (9Z)-beta-carotene decreased during storage at either temperature, whereas storage at 4 degrees C resulted in a 109% increase in (13Z)-beta-carotene after 56 days. Cooking significantly increased the levels of (13Z)-beta-carotene and (9Z)-beta-carotene and resulted in the production of (15Z)-beta-carotene, which was absent in raw carrots. Storage at 4 degrees C for 15 days or more prior to cooking reduced the susceptibility of (all-E)-beta-carotene to thermal isomerization during cooking, resulting in lower levels of all three Z-beta-carotene isomers being generated, while storage at 20 degrees C for up to 21 days resulted in significantly higher levels of (all-E)-beta-carotene before and after cooking but had no effect on Z-isomer production during cooking. Consequently, we conclude that, for the greatest health benefit, fresh carrots can be stored for up to 21 days at 20 degrees C or at 4 degrees C for up to 56 days without significant reduction in (all-E)-beta-carotene and should be consumed raw or boiled for less than 15 min to limit Z-beta-carotene isomer formation.
Desorption electrospray ionization mass spectrometry was investigated as a means to qualitatively identify and to quantify analytes directly from developed normal-phase thin-layer chromatography plates. The atmospheric sampling capillary of a commercial ion trap mass spectrometer was extended to permit sampling and ionization of analytes in bands separated on intact TLC plates (up to 10 cmx10 cm). A surface positioning software package and the appropriate hardware enabled computer-controlled surface scanning along the length of development lanes or at fixed Rf value across the plates versus the stationary desorption electrospray emitter. Goldenseal (Hydrastis canadensis) and related alkaloids and commercial dietary supplements were used as standards and samples. Alkaloid standards and samples were spotted and separated on aluminum- or glass-backed plates using established literature methods. The mass spectral signal levels as a function of desorption spray solvent were investigated with acetonitrile proving superior to methanol. The detection levels (approximately 5 ng each or 14-28 pmol) in mass spectral full-scan mode were determined statistically from the calibration curves (2.5-100 pmol) for the standards berberine, palmatine, and hydrastinine spotted as a mixture and separated on the plates. Qualitative screening of the major alkaloids present in six different over-the-counter "goldenseal" dietary supplements was accomplished by obtaining full-scan mass spectra during surface scans along the development lane in the direction of increasing Rf value. In one sample, alkaloids were detected that strongly suggested the presence of at least one additional herb undeclared on the product label. These same data indicated the misidentification of one of the alkaloids in the TLC literature. Quantities of the alkaloids present in two of the samples determined using the mass spectral data were in reasonable agreement with the label values, indicating the quantitative ability of the method. The advantage of mass spectral measurements in identifying and quantifying materials within overlapping bands and in providing positive identification for even minor species in a mixture was also demonstrated.
The flavonoid composition of immature leaves of pak choi [Brassica rapa L. ssp. chinensis L. (Hanelt.)] was investigated. Flavonol aglycone content was measured in 11 pak choi varieties, indicating significant differences (P < 0.05) in content between varieties and relatively high contents of kaempferol and isorhamnetin. Levels of quercetin ranged from 3.2 to 6.1 mg/100 g of dry weight (DW), whereas levels of isorhamnetin and kaempferol were significantly higher (8.1-35.1 and 36.0-102.6 mg/100 g of DW, respectively). A large number of glycoside and hydroxycinnamic acid derivatives of quercetin, kaempferol, and isorhamnetin were identified in cv. 'Shanghai' by LC/UV-DAD/ESI-MS/MS. The UV-DAD data allowed identification of hydroxycinnamic acid derivatives, but detailed MS/MS fragmentations were required for the structure elucidation. Pak choi could be a potentially important source of dietary flavonols, in particular, kaempferol and isorhamnetin.
Quantitative determination of caffeine on reversed-phase C8 thin-layer chromatography plates using a surface sampling electrospray ionization system with tandem mass spectrometry detection is reported. The thin-layer chromatography/electrospray tandem mass spectrometry method employed a deuterium-labeled caffeine internal standard and selected reaction monitoring detection. Up to nine parallel caffeine bands on a single plate were sampled in a single surface scanning experiment requiring 35 min at a surface scan rate of 44 mum/s. A reversed-phase HPLC/UV caffeine assay was developed in parallel to assess the mass spectrometry method performance. Limits of detection for the HPLC/UV and thin-layer chromatography/electrospray tandem mass spectrometry methods determined from the calibration curve statistics were 0.20 ng injected (0.50 muL) and 1.0 ng spotted on the plate, respectively. Spike recoveries with standards and real samples ranged between 97 and 106% for both methods. The caffeine content of three diet soft drinks (Diet Coke, Diet Cherry Coke, Diet Pepsi) and three diet sport drinks (Diet Turbo Tea, Speed Stack Grape, Speed Stack Fruit Punch) was measured. The HPLC/UV and mass spectrometry determinations were in general agreement, and these values were consistent with the quoted values for two of the three diet colas. In the case of Diet Cherry Coke and the diet sports drinks, the determined caffeine amounts using both methods were consistently higher (by approximately 8% or more) than the literature values.
This report documents the results of Phase 1 of the ''Air Force Hydrazine Detector Characterization and Calibration Project''. A method for calibrating model MDA 7100 hydrazine detectors in the United States Air Force (AF) inventory has been developed. The calibration system consists of a Kintek 491 reference gas generation system, a humidifier/mixer system which combines the dry reference hydrazine gas with humidified diluent or carrier gas to generate the required humidified reference for calibrations, and a gas sampling interface. The Kintek reference gas generation system itself is periodically calibrated using an ORNL-constructed coulometric titration system to verify the hydrazine concentration of the sample atmosphere in the interface module. The Kintek reference gas is then used to calibrate the hydrazine monitors. Thus, coulometric titration is only used to periodically assess the performance of the Kintek reference gas generation system, and is not required for hydrazine monitor calibrations. One advantage of using coulometric titration for verifying the concentration of the reference gas is that it is a primary standard (if used for simple solutions), thereby guaranteeing, in principle, that measurements will be traceable to SI units (i.e., to the mole). The effect of humidity of the reference gas was characterized by using the results of concentrations determined by coulometric titration to develop a humidity correction graph for the Kintek 491 reference gas generation system. Using this calibration method, calibration uncertainty has been reduced by 50% compared to the current method used to calibrate hydrazine monitors in the Air Force inventory and calibration time has also been reduced by more than 20%. Significant findings from studies documented in this report are the following: (1) The Kintek 491 reference gas generation system (generator, humidifier and interface module) can be used to calibrate hydrazine detectors. (2) The Kintek system output concentration is less than the calculated output of the generator alone but can be calibrated as a system by using coulometric titration of gas samples collected with impingers. (3) The calibrated Kintek system output concentration is reproducible even after having been disassembled and moved and reassembled. (4) The uncertainty of the reference gas concentration generated by the Kintek system is less than half the uncertainty of the Zellweger Analytics' (ZA) reference gas concentration and can be easily lowered to one third or less of the ZA method by using lower-uncertainty flow rate or total flow measuring instruments. (5) The largest sources of uncertainty in the current ORNL calibration system are the permeation rate of the permeation tubes and the flow rate of the impinger sampling pump used to collect gas samples for calibrating the Kintek system. Upgrading the measurement equipment, as stated in (4), can reduce both of these. (6) The coulometric titration technique can be used to periodically assess the performance of the Kintek system and determine a suitable recalibration interval. (7) The Kintek system has been used to calibrate two MDA 7100s and an Interscan 4187 in less than one workday. The system can be upgraded (e.g., by automating it) to provide more calibrations per day. (8) The humidity of both the reference gas and the environment of the Chemcassette affect the MDA 7100 hydrazine detector's readings. However, ORNL believes that the environmental effect is less significant than the effect of the reference gas humidity. (9) The ORNL calibration method based on the Kintek 491 M-B gas standard can correct for the effect of the humidity of the reference gas to produce the same calibration as that of ZA's. Zellweger Analytics calibrations are typically performed at 45%-55% relative humidity. (10) Tests using the Interscan 4187 showed that the instrument was not accurate in its lower (0-100 ppb) range. Subsequent discussions with Kennedy Space Center (KSC) personnel also indicated that the Interscan units were not reproducible when new sensors were used. KSC had discovered that the Interscan units read incorrectly on the low range because of the presence of carbon dioxide. ORNL did not test the carbon dioxide effect, but it was found that the units did not read zero when a test gas containing no hydrazine was sampled. According to the KSC personnel that ORNL had these discussions with, NASA is phasing out the use of these Interscan detectors.
The effects of post-harvest and packaging treatments on glucoraphanin (4-methylsulfinylbutyl glucosinolate), the glucosinolate precursor of anticancer isothiocyanate sulforaphane [4-methylsulfinylbutyl isothiocyanate], were examined in broccoli (Brassica oleracea var. italica) during storage times. The results showed that at 20 degrees C, 55% loss of glucoraphanin concentration occurred in broccoli stored in open boxes during the first 3 days of the treatment and 56% loss was found in broccoli stored in plastic bags by day 7. Under both air and controlled atmosphere (CA) storage, glucoraphanin concentration appeared to fluctuate slightly during 25 days of storage and the concentrations under CA was significantly higher than those stored under air treatment. In modified atmosphere packaging (MAP) treatments, glucoraphanin concentration in air control packaging decreased significantly whereas there were no significant changes in glucoraphanin concentration in MAP with no holes at 4 degrees C and two microholes at 20 degrees C for up to 10 days. Decreases in glucoraphanin concentration occurred when the broccoli heads deteriorated. In the present study, the best method for preserving glucoraphanin concentration in broccoli heads after harvest was storage of broccoli in MAP and refrigeration at 4 degrees C. This condition maintained the glucoraphanin concentration for at least 10 days and also maintained the visual quality of the broccoli heads.
The objective of this investigation was to determine the extent of areal and day-to-day variability of stationary environmental tobacco smoke (ETS) concentrations in a single large facility where smoking was both prevalent and unrestricted, and to determine the degree of daily variation in the personal exposure levels of ETS constituents in the same facility. The subject facility was a relatively new four-story office building with an approximate volume of 1.3 million ft 3 . The exchange of outside air in the building was determined to be between 0.6 and 0.7 air changes per hour. Eighty-seven area samples (excluding background) were collected at 29 locations over the course of 6 days of sampling. Locations included offices and cubicles occupied by smokers and nonsmokers, common areas, and the computer and mail rooms. Twenty-four nonsmoking subjects wore personal sampling systems to collect breathing zone air samples on each of 3 days in succession. This generated a total of seventy-two 8-h time-weighted average (TWA) personal exposure samples. In all samples, respirable suspended particulate matter, ultraviolet light-absorbing and fluorescing particulate matter, solanesol, nicotine, and 3-ethenyl pyridine were determined. With the exception of a few locations, tobacco-specific airborne constituents were determined in all samples. Not surprisingly, areas with the highest ETS constituent concentrations were offices and cubicles of smokers. Median and 95th percentile concentrations for all area samples, excluding background, were determined to be 1.5 and 8.7 μg/m 3 for nicotine, and 8.2 and 59 μg/m 3 for ETS-specific particles (as solanesol-related particulate matter, Sol-PM), respectively. Personal exposure concentrations of ETS components were similar to those levels found in the area samples (median nicotine and Sol-PM concentrations were 1.24 and 7.1 μg/m 3 , respectively), but the range of concentrations was somewhat smaller. For example, the 95th percentile 8-h TWA nicotine and ETS-specific particle (as Sol-PM) concentrations were 3.58 and 21.9 μg/m 3 , respectively. Intrasubject variation of daily concentrations ranged from 20% to 60%, depending on the component. Self-reported proximity to smokers was supported by higher ETS concentrations determined from the personal monitors, but only to a modest extent. Although smoking was completely unrestricted inside the main office areas of the facility, ETS levels, either areal or from personal exposure measurements, were lower than those estimated by Occupational Safety and Health Administration to be present in such facilities.
AbstractThe interest in analytical procedures for explosives residues in environmental media steadily increases as more and more formerly utilized military sites are certified and converted to full‐ or part‐time civilian use. Careful statistical studies have clearly demonstrated that analyses based on randomly collected “grab” samples of soils frequently produce a false picture of the extent of explosives contamination. Well‐designed sampling plans, which employ multiple samples taken from small areas and which consider the distribution of the soil particles, are mandatory for understanding the true extent of contamination. Because site remediation is such a costly venture, there is a strong need for analytical procedures which are capable of quantitating explosives in soil and groundwater samples quickly and accurately, using equipment and methods which may be operated reliably by nontechnical personnel. For that reason, scientific interest is gradually moving away from the completely laboratory‐based, statistically validated, and highly technical standardized methods, such as high‐pressure liquid chromatography (HPLC) and gas chromatography (GC) and their mass spectroscopic analogs, towards the many fieldable analytical techniques. Some of these, such as ion mobility spectrometry and the various magnetic resonance techniques, are still in their infancy; their potential and utility are still to be fully developed. Others, such as the colorimetric and enzyme‐based field test kits, have been fully tested and, in some cases, have been adopted as standard methods themselves. Still others, such as the various mass spectrometric methods, involve highly technical equipment which must be simplified before it can be used routinely in the field. However, the extreme sensitivities characteristic of these state‐of‐the‐art instruments partially offset the need for extensive operator training. A variety of mass spectrometric techniques may yet be used routinely for explosives residue analysis in the field. Some of these new methods may be used in, or even be derived from, forensic applications.
A method is described for determining methylphosphonic acid, ethyl methylphosphonic acid and isopropyl methylphosphonic acid, which are hydrolysis products of the nerve agents VX (S-2-diisopropylaminoethyl O-ethyl methylphosphonothiolate) and GB (sarin, isopropylmethyl phosphonofluoridate). The analytes are extracted from 50 ml groundwater using a solid-phase extraction column packed with 500 mg of silica with a bonded quaternary amine phase, and are eluted and derivatized with methanolic trimethylphenylammonium hydroxide. Separation and quantitation are achieved using a capillary column gas chromatograph equipped with a flame photometric detector operated in its phosphorus-selective mode. Two independent statistically-unbiased procedures were employed to determine the detection limits, which ranged between 3 and 9 μg/l, for the three analytes.
Di-isopropyl methylphosphonate (DIMP) is a byproduct from the manufacture of the nerve agent Sarin. The persistence of DIMP in the ground water is an important question in evaluating the potential environmental impacts of DIMP contamination. The half-life of DIMP in ground water at 10 deg C was estimated to be 500 years with a 95% confidence interval of 447 to 559 years from measurements of the hydrolysis rates at temperatures between 70 to 98 deg C.Extrapolation of the kinetics to 10 deg C used the Arrhenius equation, and calculation of the half-life assumed first-order kinetics. Inorganic phosphate was not detected.
Part 1 Background indoor air contaminants: general considerations combustion products volatile organic compounds. Part 2 Mainstream and sidestream cigarette smoke: terms and conventions formation and properties mainstream and sidestream constituents. Part 3 Properties and measures of environmental tobacco smoke: physical characteristics of ETS chemical composition of ETS markers for environmental tobacco smoke. Part 4 General sampling and analysis considerations: general considerations sampling methods and materials measurement methodologies area sampling vs. personal monitoring experimental designs and supporting observations. Part 5 Field studies - particulate matter: sampling and analysis methods results of field studies. Part 6 Field studies - nicotine: sampling and analysis methods results of field studies nicotine uptake by non-smokers. Part 7 Field studies - carbon monoxide: sampling and analysis field studies. Part 8 Field studies - oxides of nitrogen: sampling and analysis field studies. Part 9 Field studies - formaldehyde: sampling and analysis methods field studies. Part 10 Field studies - volatile organic compounds: sampling and analysis methods field studies. Part 11 Field studies - trace constituents: polycyclic aromatic hydrocarbons n-nitrosamines. Part 12: appendices.