Objective: Clinical cardiac CT multiphase reconstructions generally provide acceptable image quality in end-diastole (ED) or end-systole (ES) phases, but in other phases may exhibit motion artifacts, especially in the right coronary artery (RCA). This limits ground-truth availability in 4D cardiac CT imaging research. We aim to construct a 4D cardiac CT dataset that is generally suitable to serve as pseudo ground truth. Methods: We propose Coronary Mask Guided Registration (CMGR) to produce a motion-preserved, artifact-reduced, and continuous-time 4D cardiac CT sequence from the clinical multiphase reconstruction of each patient. For artifact reduction, CMGR uses the ED or ES phase as the reference phase and warps the reference volume with deformation fields to produce the sequence. For motion preservation, CMGR registers the reference phase to each non-reference phase of the multiphase reconstruction. To capture the motion of both the RCA and other cardiac structures in each registration, CMGR regularizes RCA masks and incorporates them into image-domain registration. Time-continuity is achieved by interpolating the deformation fields for non-reference phases to arbitrary times. Results: CMGR outperformed representative image-domain registration methods in capturing RCA motion and providing reasonable RCA shape, and showed competitive performance in capturing whole-heart motion. Additionally, CMGR reduced motion artifacts from clinical multiphase reconstructions, and intermediate CMGR frames generally provided plausible transitions between discrete cardiac phases. Conclusion: CMGR provides an effective approach for constructing continuous-time 4D cardiac CT datasets. Significance: The dataset can be used in system design simulations and in reconstruction algorithm development, thereby facilitating advances in cardiac CT imaging.
Background There is still limited data on predictive value of coronary computed tomography angiography(CCTA)-derived fractional flow reserve(CT-FFR)for long term outcomes.We examined the long-term prognostic value of CT-FFR combined with CCTA-defined atherosclerotic extent in diabetic patients with coronary artery disease(CAD). Methods A retrospective pooled analysis of individual patient data was performed.Deep-learning-based vessel-specific CT-FFR was calculated.All patients enrolled were followed-up for at least 5 years.Predictive abilities for major adverse cardiac events(MACE)were compared among three models(model 1,constructed using clinical variables;model 2,model 1+CCTA-de-rived atherosclerotic extent(Leiden risk score);and model 3,model 2+CT-FFR. Results A total of 480 diabetic patients[median age,61(55-66)years;52.9%men]were included.During a median follow-up time of 2197(2126-2355)days,55 patients(11.5%)experienced MACE.In multivariate-adjusted Cox models,Leiden risk score(HR:1.06;95%CI:1.01-1.11;P=0.013)and CT-FFR≤0.80(HR:6.54;95%CI:3.18-13.45;P<0.001)were the independent predict-ors.The discriminant ability was higher in model 2 than in model 1(C-index,0.75 vs.0.63;P<0.001)and was further promoted by adding CT-FFR to model 3(C-index,0.81 vs.0.75;P=0.002).Net reclassification improvement(NRI)was 0.19(P=0.009)for model 2 beyond model 1.Of note,adding CT-FFR to model 3 also exhibited significantly improved reclassification compared with model 2(NRI=0.14;P=0.011). Conclusion In diabetic patients with CAD,CT-FFR provides robust and incremental prognostic information for predicting long-term outcomes.The combined model exhibits improved prediction abilities,which is beneficial for risk stratification.
Coronary computed tomography angiography (CCTA), which enables noninvasive assessment of luminal stenosis and atherosclerotic plaque components, has become the first-line technique for evaluating coronary artery disease. Artificial intelligence (AI) has the potential to revolutionize the CCTA workflow. However, it is crucial to evaluate the effectiveness and feasibility of AI algorithms before their clinical deployment. This expert consensus proposes three fundamental elements of research designs of AI in CCTA and offers corresponding recommendations. The consensus also reviews the existing evidence on AI applications in CCTA and provides recommendations on the current clinical applications of AI, including image acquisition and reconstruction, postprocessing, diagnosis, prognostic prediction, guiding prevention and treatment, and cardiovascular disease prevention.
Background Understanding pandemic-related reductions and subsequent recovery of cardiovascular testing in Asia is important for guiding regional public health efforts.Objectives This study sought to evaluate the recovery of cardiovascular testing in Asia 1 year into the COVID-19 pandemic.Methods In this subanalysis of a worldwide survey on the impact of COVID-19 on cardiovascular diagnostic care in April 2020 and April 2021, recovery of testing volume in Asia was compared among subregions, World Bank income groups and imaging modalities.Results Of 669 sites worldwide, 164 sites were in 33 Asian countries. Cardiovascular testing volumes in Asia decreased by 53% from March 2019 to April 2020, then recovered 96% of this decrease by April 2021, compared with 98% recovery in the rest of the world. Eastern Asia and Western and Central Asia reported recovery rates of 123% and 110%, compared with 50% and 80% recovery in Southern and South-eastern Asia. Testing volumes among high-income and upper-middle-income Asian countries recovered to 117% and 121% but remained depressed at 49% and 14% recovery in lower-middle and low-income countries, respectively. Stress ECG, stress echo and stress positron emission tomography studies experienced median reductions of 48%, 35% and 57% in testing volume between March 2019 and April 2021, while volumes of coronary artery calcium, coronary CT angiography and cardiac MR remained stable during this period.Conclusions The recovery of cardiovascular testing in Asia 1 year into the COVID-19 pandemic lagged in the Southern and South-eastern subregions, as well as in lower-income countries. Recovery favoured advanced cardiac imaging modalities over standard stress testing modalities.
To evaluate the clinical manifestations, image characteristics and prognosis of pulmonary artery dissection (PAD) compared with pulmonary hypertension (PH). Patients diagnosed with PAD and PH were retrospectively enrolled. The clinical presentation, image characteristics, and hemodynamic parameters of right heart catheterization were compared between the two groups. Kaplan–Meier survival analysis was used to evaluate the prognosis of PAD. Seventeen patients with PAD (mean age ± SD, 38 ± 11 years; 7 men [41.2
To validate a fully automated, deep learning model based on coronary computed tomography angiography (CCTA) for the diagnosis of obstructive coronary artery disease (CAD) with stenosis ≥ 50
RATIONALE AND OBJECTIVES:Takayasu's arteritis (TA) mainly affects the aorta and its branches involving the coronary arteries. Coronary CT angiography can be used to detect coronary artery lesions. Outcome of TA patients with coronary involvement has not been well established. Our study aimed to systematically analyze coronary lesions in patients with TA and to access long-term outcome in TA patients with coronary involvement. MATERIALS AND METHODS:A retrospective cohort study of TA patients with coronary CT angiography was conducted between January 2009 and October 2021. Baseline clinical characteristics, laboratory parameters, imaging features and therapeutic features were collected and analyzed. Follow-up was scheduled since the onset of TA. Overall survival and major adverse cardiovascular events (MACE) were analyzed in patients with coronary lesions. RESULTS:48 (59.3%) TA patients had coronary involvement. Coronary ostial stenosis was detected in 31 (64.6%) patients by MDCT. Prevalence of disease activity (p = 0.007) was higher in patients with ostial stenosis. The median follow-up was 10.0 years. Death was observed in nine patients including seven died from myocardial infarction. TA patients with ostial stenosis had higher rate of MACE (p = 0.013). Baseline activity(HR: 5.250, 95%CI 2.004-8.639), ostial involvement(HR:8.954, 95%CI 3.875-56.038), stenosis≥ 70% (HR: 10.822, 95%CI 2.764-61.230) and activity recurrence (HR:11.913, 95%CI 2.321-85.747) were independently associated with increased major cardiovascular events. CONCLUSION:MDCT should be performed in patients suspected with coronary involvement to make early diagnosis. Myocardial ischemia is the major cause of longterm death in TA patients with coronary lesions. Baseline disease activity, coronary ostial stenosis, stenosis ≥ 70% and activity recurrence were independent risk factors of cardiovascular events in TA patients.
BACKGROUND: The adult mammalian heart is incapable of regeneration, whereas a transient regenerative capacity is maintained in the neonatal heart, primarily through the proliferation of preexisting cardiomyocytes. Neonatal heart regeneration after myocardial injury is accompanied by an expansion of cardiac fibroblasts and compositional changes in the extracellular matrix. Whether and how these changes influence cardiomyocyte proliferation and heart regeneration remains to be investigated. METHODS: We used apical resection and myocardial infarction surgical models in neonatal and adult mice to investigate extracellular matrix components involved in heart regeneration after injury. Single-cell RNA sequencing and liquid chromatography–mass spectrometry analyses were used for versican identification. Cardiac fibroblast–specific Vcan deletion was achieved using the mouse strains Col1a2-2A-CreER and Vcan fl/fl . Molecular signaling pathways related to the effects of versican were assessed through Western blot, immunostaining, and quantitative reverse transcription polymerase chain reaction. Cardiac fibrosis and heart function were evaluated by Masson trichrome staining and echocardiography, respectively. RESULTS: Versican, a cardiac fibroblast–derived extracellular matrix component, was upregulated after neonatal myocardial injury and promoted cardiomyocyte proliferation. Conditional knockout of Vcan in cardiac fibroblasts decreased cardiomyocyte proliferation and impaired neonatal heart regeneration. In adult mice, intramyocardial injection of versican after myocardial infarction enhanced cardiomyocyte proliferation, reduced fibrosis, and improved cardiac function. Furthermore, versican augmented the proliferation of human induced pluripotent stem cell–derived cardiomyocytes. Mechanistically, versican activated integrin β1 and downstream signaling molecules, including ERK1/2 and Akt, thereby promoting cardiomyocyte proliferation and cardiac repair. CONCLUSIONS: Our study identifies versican as a cardiac fibroblast–derived pro-proliferative proteoglycan and clarifies the role of versican in promoting adult cardiac repair. These findings highlight its potential as a therapeutic factor for ischemic heart diseases.
Background Risk prediction rules are important to establish appropriate treatment and management strategy for patients with different risk classification of pulmonary embolism (PE). Neutrophils are considered to be related to PE as an essential marker of inflammation. However, few studies have reported the association between neutrophil levels and risk classification of acute PE (APE). The aim of this study was to investigate the role of neutrophil levels upon admission in the assessment of risk classification of APE. Methods A total of 299 consecutive APE patients and 90 patients without APE confirmed by computed tomographic pulmonary angiography were retrospectively screened. APE patients were stratified into two subgroups according to clinical guidelines: low- ( n = 233) and intermediate- and high-risk ( n = 60) APE. Results The neutrophil levels in intermediate- and high-risk APE patients were significantly higher compared to low-risk APE or non-APE patients ( P < 0.001). In multivariable logistic regression analysis, neutrophil levels were significantly and independently associated with intermediate- and high-risk APE (odds ratio = 1.239, 95% confidence interval [CI] 1.055–1.455, P = 0.009). Neutrophil levels were positively correlated with the pulmonary embolism severity index score ( r = 0.357, P < 0.001), high sensitive C-reactive protein, D-dimer and pulmonary artery obstruction index (PAOI), in the overall population of APE patients. Receiver-operating characteristic curve analysis revealed that neutrophils had a better diagnostic value for intermediate- and high-risk APE (area under the curve [AUC] = 0.760, 95% CI 0.695–0.826; P < 0.001) compared to PAOI (AUC = 0.719) and D-dimer (AUC = 0.645). Conclusions High neutrophil levels upon admission were significantly and independently associated with intermediate- and high-risk APE, which could be regarded as an indicator of inflammation and thrombosis in APE simultaneously. The potent diagnostic role of neutrophil levels and their competitive advantage over PAOI and D-dimer for the assessment of APE risk classification are suggested.
Background: Coronary computed tomography angiography (CCTA) is an established first-line test in the investigation of patients with suspected coronary artery disease (CAD), while the perivascular fat attenuation index (FAI) derived from CT seems to be a feasible and efficient tool for the identification of ischemia. The association between the FAI and lesion-specific ischemia as assessed by fractional flow reserve (FFR) remains unclear. Methods: In a total of 261 patients, 294 vessels were assessed for CCTA stenosis, vessel-specific FAI, lesion-specific FAI, and plaque characteristics. The diagnostic accuracies of each parameter and the combined approach were analyzed via the receiver operating characteristic curve (ROC) with FFR as the reference standard. The determinants of FAI were statistically analyzed. Results: The cutoff values of vessel-specific FAI and lesion-specific FAI scores calculated according to the Youden index were −70.97 and −73.95 HU, respectively. No significant differences were noted between them; however, they exhibited a strong correlation. No significant differences were noted between the area under the curve (AUC) scores of vessel-specific FAI (0.677), lesion-specific FAI (0.665), and CCTA (0.607) (p > 0.05 for all) results. The addition of two FAI measures to the CCTA showed improvements in the discrimination (AUC) and reclassification ability (relative integrated discrimination improvement (IDI) and category-free net reclassification index (NRI)), vessel-specific FAI (AUC, 0.696; NRI, 49.6%; IDI, 5.9%), and lesion-specific FAI scores (AUC, 0.676; NRI, 43.3%; IDI, 5.4%); (p < 0.01 for all). Multivariate analysis revealed that low-attenuation plaque (LAP) volume was an independent predictor of two FAI measures. Conclusion: The combined approach of adding vessel-specific FAI or lesion-specific FAI scores could improve the identification of ischemia compared with CCTA alone. The LAP volume was the independent risk factor for both tools.
Aims: To explore the effect of coronary calcification severity on the measurements and diagnostic performance of computed tomography-derived fractional flow reserve (FFR; CT-FFR). Methods: This study included 305 patients (348 target vessels) with evaluable coronary calcification (CAC) scores from CT-FFR CHINA clinical trial. The enrolled patients all received coronary CT angiography (CCTA), CT-FFR, and invasive FFR examinations within 7 days. On both per-patient and per-vessel levels, the measured values, accuracy, and diagnostic performance of CT-FFR in identifying hemodynamically significant lesions were analyzed in all CAC score groups (CAC = 0, > 0 to <100, ≥ 100 to <400, and ≥ 400), with FFR as reference standard. Results: In total, the sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and area under receiver operating characteristics curve (AUC) of CT-FFR were 85.8, 88.7, 86.9, 87.8, 87.1%, 0.90 on a per-patient level and 88.3, 89.3, 89.5, 88.2, 88.9%, 0.88 on a per-vessel level, respectively. Absolute difference of CT-FFR and FFR values tended to elevate with increased CAC scores (CAC = 0: 0.09 ± 0.10; CAC > 0 to <100: 0.06 ± 0.06; CAC ≥ 100 to <400: 0.09 ± 0.10; CAC ≥ 400: 0.11 ± 0.13; p = 0.246). However, no statistically significant difference was found in patient-based and vessel-based diagnostic performance of CT-FFR among all CAC score groups. Conclusion: This prospective multicenter trial supported CT-FFR as a viable tool in assessing coronary calcified lesions. Although large deviation of CT-FFR has a tendency to correlate with severe calcification, coronary calcification has no significant influence on CT-FFR diagnostic performance using the widely-recognized cut-off value of 0.8.
BACKGROUND The extent to which health care systems have adapted to the COVID-19 pandemic to provide necessary cardiac diagnostic services is unknown. OBJECTIVES The aim of this study was to determine the impact of the pandemic on cardiac testing practices, volumes and types of diagnostic services, and perceived psychological stress to health care providers worldwide. METHODS The International Atomic Energy Agency conducted a worldwide survey assessing alterations from baseline in cardiovascular diagnostic care at the pandemic's onset and 1 year later. Multivariable regression was used to determine factors associated with procedure volume recovery. RESULTS Surveys were submitted from 669 centers in 107 countries. Worldwide reduction in cardiac procedure volumes of 64% from March 2019 to April 2020 recovered by April 2021 in high- and upper middle-income countries (recovery rates of 108% and 99%) but remained depressed in lower middle- and low-income countries (46% and 30% recovery). Although stress testing was used 12% less frequently in 2021 than in 2019, coronary computed tomographic angiography was used 14% more, a trend also seen for other advanced cardiac imaging modalities (positron emission tomography and magnetic resonance; 22%-25% increases). Pandemic-related psychological stress was estimated to have affected nearly 40% of staff, impacting patient care at 78% of sites. In multivariable regression, only lower-income status and physicians' psychological stress were significant in predicting recovery of cardiac testing. CONCLUSIONS Cardiac diagnostic testing has yet to recover to prepandemic levels in lower-income countries. Worldwide, the decrease in standard stress testing is offset by greater use of advanced cardiac imaging modalities. Pandemic-related psychological stress among providers is widespread and associated with poor recovery of cardiac testing. (C) 2022 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation.
BACKGROUND:The association between pericoronary fat attenuation index (FAI), plaque characteristics, and lesion-specific ischemia identified by fractional flow reserve (FFR) remains unclear. METHODS:Coronary computed tomography angiography (CCTA) stenosis, FAI, plaque characteristics, FFR derived from computed tomography (FFRCT) and FFR were assessed in 280 vessels of 247 patients. Stenosis ≥50% was considered obstructive. Optimal thresholds of FAI and plaque variables were defined by the area under the receiver-operating characteristics curve (AUC) analysis. Ischemia was defined by FFR ≤ 0.80. RESULTS:FAI ≥ -71.9 HU, low-attenuation plaque (LAP) ≥ 49.62 mm3 and aggregate plaque volume (APV) ≥ 28.91% predicted ischemia independent of other plaque characteristics. The addition of FAI ≥ -71.9 HU improved discrimination (AUC, 0.720 vs. 0.674, P = 0.035) and reclassification abilities (category-free net reclassification index [NRI], 0.470, P < 0.001; relative integrated discrimination improvement [IDI], 0.047, P < 0.001) of ischemia compared with stenosis evaluation alone, with further discrimination (AUC, 0.772 vs. 0.720, P = 0.028) and reclassification abilities (NRI, 0.385, P = 0.001; relative IDI, 0.077, P < 0.001) of ischemia by adding information regarding LAP ≥49.62 mm3 + APV ≥ 28.91%. And the diagnostic performance of combination approach was comparable to that of FFRCT alone (AUC, 0.772 vs. 0.762, P = 0.771). CONCLUSIONS:Stenosis severity, FAI, plaque characteristics predicted lesion-specific ischemia. The combination of FAI and plaque assessment improved the discrimination of ischemia compared with stenosis assessment alone.
To assess the diagnostic performance of fractional flow reserve (FFR) derived from coronary computed tomography angiography (CTA) (CT-FFR) obtained by a new computational fluid dynamics (CFD) algorithm to detect ischemia, using FFR as a reference, and analyze the characteristics of "gray zone" and misdiagnosed lesions. This prospective multicenter clinical trial (NCT03692936, https://clinicaltrials.gov/) analyzed 317 patients with coronary stenosis between 30 and 90% in 366 vessels from five centers undergoing CTA and FFR between November 2018 and March 2020. CT-FFR were obtained from a CFD algorithm (Heartcentury Co., Ltd., Beijing, China). Diagnostic performance of CT-FFR and CTA in detecting ischemia was assessed. Coronary atherosclerosis characteristics of gray zone and misdiagnosed lesions were analyzed. Per-vessel sensitivity, specificity and accuracy for CT-FFR and CTA were 89.9, 87.8, 88.8% and 89.3, 35.5, 60.4%, respectively. Accuracy of CT-FFR was 80.0% in gray zone lesions. In gray zone lesions, lumen area and diameter were significantly larger than lesions with FFR < 0.76 (both p < 0.001), lesion length, non-calcified and calcified plaque volume were all significantly higher than non-ischemic lesions (all p < 0.05). In gray zone lesions, Agatston score (OR = 1.009, p = 0.044) was the risk factor of false negative results of CT-FFR. In non-ischemia lesions, coronary stenosis >50% (OR = 2.684, p = 0.03) was the risk factor of false positive results. Lumen area (OR = 0.567, p = 0.02) and diameter (OR = 0.296, p = 0.03) had a significant negative effect on the risk of false positive results of CT-FFR. In conclusion, CT-FFR based on the new parameter-optimized CFD model provides better diagnostic performance for lesion-specific ischemia than CTA. For gray zone lesions, stenosis degree was less than those with FFR < 0.76, and plaque load was heavier than non-ischemic lesions.
ObjectiveDelayed enhancement cardiac CT is a reliable tool for the diagnosis of left atrial appendage thrombus but limited for scanning heterogeneity. We aimed to explore the improvement of the 1 and 3-min delay phase at the diagnostic level to detect left atrial appendage thrombus, in order to set up a reasonable CT scanning scheme.Materials and MethodsA total of 6,524 patients were continuously retrieved from January 2015 to September 2020 retrospectively. The patients had undergone Transesophageal echocardiography (TEE) and cardiac CT with complete period include the arterial enhancement phase, 1 and 3-min delay phase, TEE were used as the reference standard. The final study included 329 patients. Three experienced radiologists independently assessed each phase of the cardiac CT images for thrombus diagnosis. We explored the improvement of the diagnostic ability of different delayed contrast-enhanced phases for left atrial appendage thrombus detection. Multiple logistic regression analysis were used for further high-risk stratification to avoid an additional 1-min delayed scan.ResultsIn total, 29 thrombosis were detected at TEE. For all cardiac CT phases, sensitivity and negative predictive were 100%. The specificity were 0.54, 0.93, and 1.00, respectively; The positive predictive values (PPV) were 0.17, 0.57, and 1.00, respectively; Area under curve (AUC) were 0.75, 0.95, and 0.98, respectively. High risk factors that cannot be clearly diagnosed with 1-min delay phase included reduced cardiac function, increased CHA2DS2-VAScscore and left atrial enlargement. Compared with the arterial enhanced phase, increased radiation doses in the 1 and 3-min delay phases were 1.7 ± 1.3 msv and 1.5 ± 0.8 msv (mean ± standard deviation).ConclusionUsing TEE as the reference standard, early contrast-enhanced CT scanning with 1 and 3-min delay is necessary for the diagnosis of left appendage thrombus, which could significantly improve the diagnostic efficiency. Patients with high-risk stratification are suitable for direct 3-min delayed scanning.
Aim The quantitative flow ratio (QFR) is favorable for functional assessment of coronary artery stenosis without pressure wires and induction of hyperemia. The aim of this study was to explore whether angiographic lesion morphology provides incremental value to generalize QFR for predicting myocardial ischemia in unselected patients. Methods This study was a substudy to the CT-FFR CHINA trial, referring 345 participants from five centers with suspected coronary artery disease on coronary CT angiography for diagnostic invasive coronary angiography (ICA). Fractional flow reserve (FFR) was measured in all vessels with 30–90% diameter stenosis. QFR was calculated in 186 lesions from 159 participants in a blinded manner. In addition, parameters to characterize lesion features were recorded or measured, including left anterior descending arteries (LADs)-involved lesions, side branch located at stenotic lesion (BL), multiple lesions (ML), minimal lumen diameter (MLD), reference lumen diameter (RLD), percent diameter stenosis (%DS), lesion length (LL), and LL/MLD4. Logistic regression was used to construct two kinds of models by combining single or two lesion parameters with the QFR. The performances of these models were compared with that of QFR on a per-vessel level. Results A total of 148 participants (mean age: 59.5 years; 101 men) with 175 coronary arteries were included for final analysis. In total, 81 (46%) vessels were considered hemodynamically significant. QFR correctly classified 82.29% of the vessels using FFR with a cutoff of 0.80 as reference standard. The area under the receiver operating characteristic curve (AUC) of QFR was 0.86 with a sensitivity, specificity, positive predictive value, and negative predictive value of 80.25, 84.04, 81.25, and 83.16%, respectively. The combined models (QFR + LAD + MLD, QFR + LAD + %DS, QFR + BL + MLD, and QFR + BL + %DS) outperformed QFR with higher AUCs (0.91 vs. 0.86, P = 0.02; 0.91 vs. 0.86, P = 0.02; 0.91 vs. 0.86, P = 0.02; 0.90 vs. 0.86, P = 0.03, respectively). Compared with QFR, the sensitivity of the combined models (QFR + BL and QFR + MLD) was improved (91.36 vs. 80.25%, 91.36 vs. 80.25%, respectively, both P < 0.05) without compromised specificity or accuracy. Conclusion Combined with angiographic lesion parameters, QFR can be optimized for predicting myocardial ischemia in unselected patients.
Background: For complicated Stanford type B aortic dissection (TBAD), thoracic endovascular aortic repair (TEVAR) is the recommended treatment; however, the type of renal artery that should be repaired remains controversial. The study aimed to investigate the changes in the renal artery and renal volume in complicated TBAD after TEVAR and the predictors of renal atrophy. Methods: The cohort study retrospectively enrolled patients with acute and subacute complicated TBAD who underwent aortic computed tomography angiography (CTA) 1 month before as well as 1 week and half a year after TEVAR from January 2010 to May 2017. According to the source of blood supply shown in preoperative CT, the renal artery was classified in 3 ways: type 1, supplied by the aortic true lumen; type 2, supplied by the aortic false lumen; or type 3, supplied by both the true and false lumen. Results: A total of 91 patients (81 men and 10 women) with an average age of 48.12 +/- 10.35 years were enrolled. Renal arteries were classified as type 1 (n=91), type 2 (n=35), and type 3 (n=56). There was no difference in the distribution of the 3 types on the left and right sides (type 1 vs. type 2 vs. type 3: 52:39 vs. 15:20 vs. 24:32; P=0.152). After TEVAR, type 3 was more likely to have spontaneous healing than type 2 (16.1% vs. 2.9%; P=0.049). There was no significant difference in the preoperative volume of kidneys of the 3 types (type 1 vs. type 2 vs. type 3: 198.23 +/- 38.68 vs. 197.37 +/- 41.77 vs. 195.10 +/- 36.11 mL; P=0.893). The postoperative volume of types 2 and 3 was smaller than that of type 1 (type 1 vs. type 2 vs. type 3: 190.09 +/- 43.25 vs. 165.15 +/- 52.63 vs. 170.70 +/- 45.28 mL; P=0.006). The renal volume was reduced in all 3 types of renal artery, especially in type 2 (the change of renal volume for type 1 vs. type 2 vs. type 3: -8.14 +/- 29.31 vs. -32.22 +/- 41.59 vs. -24.41 +/- 38.44 mL; P=0.001). The relative change of renal volume for type 1 vs. type 2 vs. type 3: (-3.64 +/- 15.69)% vs. (-16.00 +/- 21.29)% vs. (-11.97 +/- 18.22)%; P=0.001). During the median follow-up of 668 days, 7 patients (7.7%) belonging to types 2 and 3 developed renal atrophy. False lumen thrombosis in the abdominal aorta and/or the renal artery was the predictor of renal atrophy [hazard ratio (HR) =17.757; P=0.008]. Conclusions: Patients with type 2 or 3 renal artery and false lumen thrombosis in the abdominal aorta and/or renal artery should be monitored closely and actively intervened to prevent renal atrophy.
BACKGROUND:The coronavirus disease 2019 (COVID-19) pandemic has adversely affected diagnosis and treatment of noncommunicable diseases. Its effects on delivery of diagnostic care for cardiovascular disease, which remains the leading cause of death worldwide, have not been quantified. OBJECTIVES:The study sought to assess COVID-19's impact on global cardiovascular diagnostic procedural volumes and safety practices. METHODS:The International Atomic Energy Agency conducted a worldwide survey assessing alterations in cardiovascular procedure volumes and safety practices resulting from COVID-19. Noninvasive and invasive cardiac testing volumes were obtained from participating sites for March and April 2020 and compared with those from March 2019. Availability of personal protective equipment and pandemic-related testing practice changes were ascertained. RESULTS:Surveys were submitted from 909 inpatient and outpatient centers performing cardiac diagnostic procedures, in 108 countries. Procedure volumes decreased 42% from March 2019 to March 2020, and 64% from March 2019 to April 2020. Transthoracic echocardiography decreased by 59%, transesophageal echocardiography 76%, and stress tests 78%, which varied between stress modalities. Coronary angiography (invasive or computed tomography) decreased 55% (p < 0.001 for each procedure). In multivariable regression, significantly greater reduction in procedures occurred for centers in countries with lower gross domestic product. Location in a low-income and lower-middle-income country was associated with an additional 22% reduction in cardiac procedures and less availability of personal protective equipment and telehealth. CONCLUSIONS:COVID-19 was associated with a significant and abrupt reduction in cardiovascular diagnostic testing across the globe, especially affecting the world's economically challenged. Further study of cardiovascular outcomes and COVID-19-related changes in care delivery is warranted.
OBJECTIVES This study sought to quantify and compare the decline in volumes of cardiovascular procedures between the United States and non-U.S. institutions during the early phase of the coronavirus disease-2019 (COVID-19) pandemic. BACKGROUND The COVID-19 pandemic has disrupted the care of many non-COVID-19 illnesses. Reductions in diagnostic cardiovascular testing around the world have led to concerns over the implications of reduced testing for cardiovascular disease (CVD) morbidity and mortality. METHODS Data were submitted to the INCAPS-COVID (International Atomic Energy Agency Non-Invasive Cardiology Protocols Study of COVID-19), a multinational registry comprising 909 institutions in 108 countries (including 155 facilities in 40 U.S. states), assessing the impact of the COVID-19 pandemic on volumes of diagnostic cardiovascular procedures. Data were obtained for April 2020 and compared with volumes of baseline procedures from March 2019. We compared laboratory characteristics, practices, and procedure volumes between U.S. and non-U.S. facilities and between U.S. geographic regions and identified factors associated with volume reduction in the United States. RESULTS Reductions in the volumes of procedures in the United States were similar to those in non-U.S. facilities (68% vs. 63%, respectively; p 1/4 0.237), although U.S. facilities reported greater reductions in invasive coronary angiography (69% vs. 53%, respectively; p < 0.001). Significantly more U.S. facilities reported increased use of telehealth and patient screening measures than non-U.S. facilities, such as temperature checks, symptom screenings, and COVID-19 testing. Reductions in volumes of procedures differed between U.S. regions, with larger declines observed in the Northeast (76%) and Midwest (74%) than in the South (62%) and West (44%). Prevalence of COVID-19, staff redeployments, outpatient centers, and urban centers were associated with greater reductions in volume in U.S. facilities in a multivariable analysis. CONCLUSIONS We observed marked reductions in U.S. cardiovascular testing in the early phase of the pandemic and significant variability between U.S. regions. The association between reductions of volumes and COVID-19 prevalence in the United States highlighted the need for proactive efforts to maintain access to cardiovascular testing in areas most affected by outbreaks of COVID-19 infection. (C) 2021 by the American College of Cardiology Foundation.