Innovative 3D high-frequency magnetic sensors have been designed and manufactured in-house for installation on the Tokamak a Configuration Variable (TCV), and are currently routinely operational. These sensors combine the Low Temperature Co-fired Ceramic (LTCC) and the thick-film technologies, and are in various aspects similar to the majority of the inductive magnetic sensors currently being procured for ITER (290 out of 505 are LTCC-1D). The TCV LTCC-3D magnetic sensors provide measurements in the frequency range up to 1MHz of the perturbations to the toroidal (quasi-parallel: delta B-TOR(similar to)delta B-PAR), vertical (quasi-poloidal: delta B-V(ER)similar to delta B-PO(L)), and radial (delta B-RAD) magnetic field components, the latter being generally different from the component normal to the Last Closed Flux-Surface (delta B-NOR). The LTCC-3D delta B-RAD measurements improve significantly on the corresponding data with the saddle loops, which are mounted onto the wall and have a bandwidth of (similar to)3 kHz (due to the wall penetration time). The LTCC-3D delta B-TOR measurements (not previously available in TCV) provide evidence that certain MHD modes have a finite delta B-P(AR) at the LCFS, as recently calculated for pressure-driven instabilities. The LTCC-3D delta B-PO(L) measurements allow to cross-check the data obtained with the Mirnov coils, and led to the identification of large EM noise pick-up for the Mirnov DAQ. The LTCC-3D data for delta B-POL agree with those obtained with the Mirnov sensors in the frequency range where the respective data acquisition overlap, routinely up to 125kHz, and up to 250kHz in some discharges, when the EM noise pick-up on the Mirnov DAQ is removed. Finally, we look at what lessons can be learnt from our work for the forthcoming procurement, installation and operation of the LTCC-1D sensors in ITER.
This work addresses the issue of attaching the force-centring part (a round ball) to the load cell of a force sensor, a piezoresistive thick-film Wheatstone bridge deposited onto a ceramic cantilever. As the current soldering process requires expensive metallisation steps for both the ball and the cantilever, and subjects the solder pads used for mounting the cantilever to an additional reflow cycle, an alternative adhesive bonding process was developed, allowing both simpler production and the use of other ball materials such as ceramic and glass. The self-centring action of solder capillary forces was ensured by structuring the adhesive so as to form a mechanical cuvette allowing centring of the ball by gravity. The selected adhesive materials exhibited good printability and bonding, as well as surviving the subsequent soldering and cleaning process steps.
AbstractMiniature ceramic cantilevers have been successfully applied to the fabrication of simple and low-cost piezoresistive thick-film force-sensing cells, using different thick-film and LTCC (low-temperature co-fired ceramic) substrates. The availability of thin substrates for some materials allows much improved sensitivity compared to classical thick-film technology, with LTCC also featuring rather low substrate elastic modulus and fine structurability. However, practical applicability may be hindered by processing difficulties, such as printing and handling very thin fired substrates, or, in the case of co-fired tapes, warpage during firing. Also, signal drift is observed with some devices. In this work, we show that most of the previously-observed signal drift in some LTCC sensors is not due to self-heating, and therefore stems from defects such as micro-cracks within the ceramic cantilevers or plastic deformations in internal conductors. In a second step, we explore manufacturability of thick-film cantilevers on very thin substrates, and show that it is possible to print a single-sided design on substrates with thickness as low as 45 μm, although a lower limit of ~100 μm, depending on substrate material, is more practical.
The present contribution gives an overview of our work on non-conventional magnetic coil sensors for diagnostics and plasma stability control of nuclear fusion experiments in tokamaks. Instead of wire wound around a core, these devices consist of printed conductor wire coils on ceramic substrates, and are based on LTCC (low-temperature co-fired ceramic) and thick-film technology, which allow creation of monolithic multilayer coils with excellent stability. For 3D sensing, an innovative modular design combining LTCC coils and an alumina base has been developed. Finally, the important aspects of integration, manufacturing, mounting and interconnection are discussed.
To monitor high-frequency fluctuations of the equilibrium magnetic field in tokamaks, a 3D magnetic sensor has been developed. The sensor, which is positioned inside the vacuum vessel behind the protective tiles of the tokamak and is exposed to potential temperatures up to 400°C, is based on thick-film and LTCC (low-temperature co-fired ceramic) technology. To connect the sensor to the cabling that runs inside the vacuum vessel, mineral-insulated cables have to be brazed to the sensor to ensure electrical connection together with mechanical robustness and sufficient thermal stability. As the brazing temperature is about 600°C, direct brazing to the alumina sensor substrate can cause failure by cracking induced by thermal stresses. It arises both by temperature gradients stemming from the localised heating and by the high thermal mismatch of alumina with the braze and wire materials. In previous work, high stresses from temperature gradients were efficiently decoupled by brazing indirectly to alumina beams attached to the main substrate, and local thermal stresses between alumina and braze/wire by using a porous metallisation. However, as the slender alumina beams protruding out of the substrate are somewhat cumbersome and fragile, three alternatives were studied in the present work: 1) testing shorter and more robust beams, 2) replacing the alumina beam by a silver wire, and 3) depositing a porous temperature- and stress-decoupling dielectric to enable direct brazing on the main alumina substrate. These solutions are characterised with respect to their mechanical robustness and of the degree of thermal decoupling with the substrate they provide.
High-frequency, 3D magnetic sensors have been designed and manufactured in-house for installation on the Tokamak à Configuration Variable (TCV). To optimize the in-vessel volume occupation, the sensors are based on combining the Low Temperature Co-fired Ceramic (LTCC) and the classical thick-film technologies. The target requirements for the three measurement axes are an effective area NAEFF=100cm2 and end-to-end resonant frequency ω0/2π=1MHz. For the as-built sensors, an effective area NAEFF∼220cm2, self-inductance LSELF∼8μH and self-resonant frequency ω0/2π∼16MHz are obtained for the primary δBNOR measurement, while NAEFF∼265cm2, NAEFF∼300cm2, LSELF∼150μH and ω0/2π∼5.5MHz are obtained for the secondary δBTOR and δBPOL measurements. When including the cabling up to the front-end electronics, ω0/2π>2MHz is expected for all three measurement axes. To optimize the measurement performance of this new magnetic diagnostic system while limiting the number of elements for the first phase of installation on TCV, five 3D sensors will be installed along the toroidal direction, allowing detection of magnetic perturbations with toroidal mode numbers |n|>30, thus significantly improving on the previous detection capabilities, which were Nyquist-limited to |n|=8.
A novel sensor based on thick-film + LTCC (low-temperature cofired ceramic) technology has been recently developed for sensing high-frequency 3D magnetic fields in tokamak fusion devices. For integration within the walls of the tokamak, the sensor has to be connected to the mineral-insulated cabling, which is carried out by brazing to ensure sufficient thermal stability. However, thermal mismatch stresses between the braze and the cable vs. the alumina substrate may cause local cracking of the latter during cooling, as the basic dense silver metallisation of the alumina does not provide a sufficient degree of stress decoupling. To address this issue, a series of porous metallisations have been formulated by incorporation of a mix of silver and fugitive graphite powder into a thick-film paste. To allow co-firing of thick, multi-layered prints. Such porous metallisations have allowed successful brazing operations, without cracking of the alumina substrate. Metallisations were assessed by measuring their electrical resistivity and shear stress have been realised as preliminary results to measure the influence of the porosity on the maximal stress before cracking.
A complete line of resistors materials are tested for the manufacture of thick-film piezoresistive sensors and associated simple adjustment / amplification circuits: 10 kΩ compositions for the gauge resistors, together with 100 Ω and 100 kΩ ones for electronics and trimming, as well as PTC compositions for temperature compensation. Several aspects are considered, such as process sensitivity, overglazing and trimming.
Although inorganic thick-film materials are usually very stable, load sensors (i.e. force, torque and pressure) based on the piezoresistive effect of thick-film resistors often exhibit some drift, with major contributions stemming from a) temperature changes or gradients, coupled with the temperature coefficient of resistance (TCR) of the sensing bridge resistors, and b) ill- defined mechanical boundary conditions, due to insufficient decoupling, plastic deformation used materials, friction or loading errors. These problems also potentially affect test samples for measuring piezoresistive response, a.k.a. the gauge factors. Here, we examine and discuss effects on the output signal of simple cantilever force sensors of two disturbances: parasitic loads and temperature gradients, and discuss / demonstrate mitigation options, and a system to reliably measure gauge factor.
Readily-available and low-cost commercial polymer-based composite materials, such as standard epoxy-fibreglass printed circuit board (PCB) substrates and resin-carbon thick-film piezoresistors, were evaluated as a solution for medical force sensors, such as a wrist rehabilitation device and an implantable wireless artificial knee force sensor. We show that such materials have high sensitivity, and sufficient short-term stability – provided careful mechanical design and materials selection are made - to allow fabrication of low-cost, robust sensors, with low processing temperatures compatible with electronics integration. Example load-sensing applications are a multi-axis wrist rehabilitation device and a knee prosthesis.
Purpose – The purpose of this paper is to study tuneable positive temperature coefficient (PTC) effect in polymer-wax-carbon composite resistors. The resistivity dependence on temperature of composite resistors made of carbon fillers dispersed in an organic matrix is known to be strongly affected by the matrix thermal expansion. High PTC effects, i.e. essentially switching from resistive to quasi-insulating behaviour, can be caused by phase changes in the matrix and the assorted volume expansion, a behaviour that has been previously shown with both simple organic waxes and semi-crystalline polymers. However, waxes become very liquid on melting, possibly resulting in carbon sedimentation, and tuneability of semi-crystalline polymers is limited. Design/methodology/approach – The authors therefore study a ternary polymer-wax-conductor (ethylcellulose-octadecanol-graphite) composite resistor system, where polymer and wax fuse to a viscous liquid on heating, and re-solidify and separate by crystallisation of the wax on cooling. Findings – It is shown that with appropriate formulation, the resulting resistors exhibit strong PTC effects, linked with the melting and crystallisation of the wax component. The behaviour somewhat depends on sample history, and notably cooling speed. Research limitations/implications – The phase equilibria and transformation kinetics of the polymer-wax system (including possible wax polymorphism), as well as the exact mechanism of the conductivity transition, remain to be investigated. Originality/value – As many compatible polymer-wax systems with different melting/solidification behaviours are available, ternary polymer-wax-conductor composite PTC resistors allow a high tuneability of properties. Moreover, the high viscosity in the liquid state should largely avoid the sedimentation issues present with binary wax-conductor systems.
Simple, low-cost and acid-resistant carbon-based screen-printed electrodes (SPEs) addressed to detection of hexavalent chromium species, Cr(VI), in sulfuric acid at pH about 1, were prepared and characterized. Working and counter electrodes were prepared jointly on the same substrate in a single strip (working-counter electrodes pair). The batch printing process allowed obtaining many working-counter electrode pairs in a unique step. The developed working electrodes are comprised of several layers deposited on an alumina substrate: (1) bottom silver conductor, (2) dense organic-graphite composite conductor, (3) active layer consisting of a porous organic-graphite composite which contains a Cr(III) ionophore for testing Cr(III) obtained after reducing Cr(VI), and (4) an insulating and protective dielectric. All materials except the bottom Ag conductor were made on an organic matrix based on a thermoplastic polymer, polyvinylbutyral (PVB). The amperometric determination of Cr(VI) species at pH 1 was performed over a wide concentration range (dynamic range 3 mu M-40 mM). The range for linear amperometric response is 3 mu M-10mM, with sensitivity about 0.08 mAmM(-1). The sensitivity is improved in comparison with previously developed sensors, while keeping a low limit of detection (LOD about 1 mu M). The response of the sensors are not interfered by the presence of Cr(III) in the solution, although the sensor can detect local formation of Cr(III) at the electrode surface after the reduction of Cr(VI) when diethylenetriaminepentaacetic acid (DTPA), a complexing agent for Cr(III) is incorporated into the pastes. (C) 2014 Elsevier B.V. All rights reserved.
1. Introduction 2. Structuration techniques 3. Examples - integration 4. Mechanical sensors & reliability 5. Thermal & chemical issues 6. Conclusion & outlook
Speciation analyses of an element allow obtaining information on the concentrations of its chemical forms present in specific environments. Chromium is largely distributed in industrial effluents often at acid pH, with the relevant oxidation states Cr (III) and Cr (VI) having contrasting impacts on the environment and health. While trivalent chromium is relatively harmelss and is an essential trace element, the hexavalent form is highly toxic. Therefore, it is important to know which species is stable, and pollution monitoring requires robust sensors that tolerate very acid pH levels. We investigate carbon-based screen-printed electrodes (SPEs), which are practical, disposable and low-cost devices and are easy to tailor to specific uses. Here, we add a specific ionophore, cuprizone, i.e. (cyclohexanone)oxaldihydrazone by electrodeposition to an electrode consisting of graphite bound with polyvinylbutyral (PVB). This matrix exhibits sufficient resistance to the acid working conditions. The combination of the analytical yield and the enormous possibilities of SPEs open the door to new sensor designs meeting the current needs of environmental and pharmacological chemical analysis.
Increasing situational awareness at human-machine interface level is a key success factor for high efficiency therapies and surgical procedures. On a technical level, cost-effective, reliable sensor integration becomes the most critical element where multi-disciplinary approaches are needed in the fields of sensor design, sensory intelligence, energy management, packaging and materials. We present two examples of mechanical human-machine-interfaces (HMIs) in completely different use cases in the medical field where sensor integration adds significant value.
Depending on the materials and processing parameters, composite materials consisting of an insulating matrix and a conductive filler may be electrically insulating, resistive or conducting. Previously, we had manufactured composites consisting of a resin and a conducting magnetic filler, and shown that polymerisation under magnetic field could achieve oriented conductors, with essentially unidirectional electrical conduction. In this work, we explore the possibility of replacing the resin matrix by a thermoplastic material, allowing in principle free reconfiguration of the filler by re-melting the matrix under different magnetic field strengths and orientations, and thereby tuning of the electrical transport properties. The formulation, fabrication and first results are reported on such materials, with an ethylcellulose - wax matrix and conducting powders based on Ag-coated Fe3O4 and Fe2CoO4 ferrites.
The Quantime project aims at developing a miniature atomic clock suited for the telecom market, requiring a wide operating temperature range (from -40 to +85°C), and a low production cost. The CPT (Coherent Population Trapping) technique for atomic interrogation is used for miniaturization and low power consumption. In the first phase of the project, the clock architecture was chosen, and the main sub-systems were developed. A clock breadboarding demonstrator was assembled and the measured Allan deviation of 1E-11 at 400 s confirms the operation of all the sub-systems.