BACKGROUND:Cardiac diffusion tensor imaging (cDTI) has traditionally relied on inefficient stimulated echo techniques to robustly assess microstructural changes over the cardiac cycle. Ultrahigh gradient strength systems (>80mT/m) allow shorter motion-compensated diffusion encoding. This study compares the ability of high and ultrahigh strength gradient systems to provide systolic and diastolic motion-compensated spin echo (MCSE) cDTI. METHODS:Second-order MCSE sequences were developed for a research-only Siemens 3T Connectom (300mT/m maximum gradient amplitude per axis), and breath-hold cDTI was acquired at peak systole and end diastole. Acquisitions used the maximum achievable gradient strength (GUH, 116mT/m) and also limited to typical high gradient strengths (GH, 66mT/m based on 80mT/m maximum allowable), giving TE = 48ms and 58 ms, respectively. Data were acquired at 2.8 × 2 .8 × 8mm3, b = 500 s/mm2 (8 averages) and b = 150 s/mm2 (2 averages) in 6 encoding directions. RESULTS:Twenty-two healthy subjects were recruited. 20/21 and 21/22 systolic acquisitions at GUH and GH, respectively, met the >50% criteria of the circumferential myocardium showing the expected transmural variation in helix angle. For GUH and GH (16/20) 80% and (16/22) 73% of diastolic acquisitions were successful, respectively. SNR was increased using GUH compared to GH (median [IQR]: 12.9 [3.8] vs. 9.6 [2.9], p = 0.0002 diastole, 15.6 [5.9] vs. 12.5 [6.7], p = 0.006 systole). Using GUH fractional anisotropy was lower in systole (0.349 [0.040] vs. 0.373 [0.019], p = 0.002) and GUH transmural helix angle gradient (HAG) was steeper in diastole (-0.70 [0.17] vs. -0.55 [0.12] ˚/%, p = 0.04). At both GUH and GH, sheetlet angle (|E2A|) was higher in systole than in diastole (30.7 [7.3] vs. 21.3 [6.7]˚ p = 10-4 and 32.6 [10.9] vs. 26.0 [7.4]˚, p = 0.03, respectively). Differences in HAG between phases were only apparent with GH (-0.88 [0.23] vs. -0.55 [0.15], p = 10-4) and differences in the mean diffusivity only with GUH (1.64 [0.11] vs. 1.52 [0.24] ×10-3mm2/s, p = 0.002). CONCLUSION:Ultrahigh-strength gradient systems deliver higher SNR for MCSE and more robust imaging in diastole. While further work is required to further improve the reliability in diastole, at ultrahigh gradient strengths, cDTI using MCSE can identify dynamic changes in the cardiac microstructure. These findings will lead to more widespread use of multiphase MCSE in cDTI clinical research.
The Gradient Impulse Response Function (GIRF) is widely used to model and correct gradient system imperfections in MRI, but scanner-specific GIRF measurement remains inaccessible to many research groups because existing approaches rely on specialised field monitoring hardware or fragmented and non-reproducible software workflows. To address this limitation, an open-source, end-to-end framework for phantom-based GIRF measurement is presented, providing a reproducible workflow requiring only standard MRI hardware and a spherical water phantom. The framework integrates vendor-independent pulse sequence generation, phantom-based data acquisition, automated data processing, and GIRF estimation. The framework was validated by comparing GIRF-predicted non-Cartesian k-space trajectories with independent measurements acquired using NMR field probes, which served as the gold-standard for trajectory characterization. Accurate prediction of rosette and spiral trajectories was demonstrated across multiple imaging orientations, with substantially lower trajectory error than the corresponding nominal trajectories. By providing the first openly available end-to-end implementation for phantom-based GIRF measurement, the barrier to routine scanner-specific GIRF characterisation is reduced, facilitating broader adoption of GIRF-based methods across the MRI community.
Aims Inflammation is a risk factor for psychosis, yet the mechanisms underlying this association remain unclear. Elevated levels of the inflammatory markers C-reactive protein (CRP) and interleukin-6 (IL-6) in childhood have been associated with increased risk of developing later psychotic experiences (PEs) and psychotic disorders. This study investigates whether CRP and IL-6 levels at age 9 are associated with brain grey matter volume at age 20, and whether this association differs between individuals with and without PEs. We hypothesise that childhood inflammation will be linked to altered grey matter volumes in adulthood, and this association will be strongest among those who develop PEs. Methods In the Avon Longitudinal Study of Parents and Children (ALSPAC) birth cohort, MRI scans were acquired at age 20 years in participants with PEs (n = 71) and controls without PEs (n = 173). Voxel-based morphometry examined the association between childhood CRP or IL-6 and grey matter volume in adulthood, with interaction analyses testing for group differences by PEs status. Results In all participants (PEs and controls) elevated IL-6 in childhood was associated with smaller grey matter volume in adulthood, in several cortical regions which did not reach significance. After excluding 4 subjects with potential acute infection, IL-6 was associated with smaller grey matter volume in the left supramarginal gyrus (pFWE = 0.028, Z = 4.24, family-wise error (FWE) corrected), right parahippocampal gyrus (pFWE = 0.047; Z = 4.21; 292 voxels), and left precuneus (pFWE = 0.035; Z = 3.65). No interaction between IL-6 and PEs group on grey matter volume was found.A significant interaction between CRP and PEs group was observed on grey matter volume (pFWE = 0.013, Z = 4.13). Elevated CRP levels in childhood were associated with larger right superior frontal gyrus volume in individuals with PEs, whereas CRP did not impact grey matter volume in controls. Effect sizes reduced after excluding 5 subjects with potential acute infection. Conclusions These findings suggest that individuals who go on to develop PEs were more vulnerable to the effects of circulating CRP on grey matter volume, consistent with a possible disease-specific pathway linking inflammation to psychosis. In contrast, IL-6 was associated with smaller volume in regions of the default mode network regardless of PEs, suggesting a more general effect on brain development.
Quantitative imaging biomarkers (QIBs) are objective measures derived from quantitative imaging that can differentiate pathological changes from healthy biological processes. Diffusion MRI parameters derived from Diffusion Tensor Imaging (DTI) and Neurite Orientation Dispersion and Density Imaging (NODDI) could serve as potential QIBs for studying both healthy neurodevelopment and various neurological conditions. However, quantitative neuroimaging studies often require large datasets collected across multiple scanners, which introduces variability. To ensure the reliability of multi-centre studies, the inter-centre reproducibility of DTI and NODDI parameters must be thoroughly assessed before data collection begins. Discrepancies between results reported by previous studies can be explained by other sources of variability. The inter-scanner reproducibility of diffusion parameters needs to be determined when the other sources of variability, such as differences in acquisition parameters, processing and ROI segmentation are controlled for. We assess the reproducibility of DTI and NODDI parameters in clinically relevant white matter (WM) tracts across three scanners of the same model, ensuring consistency in the acquisition scheme and pre-processing pipelines. WM tract regions of interest (ROIs) are automatically segmented to standardise the analysis. Additionally, we investigate ROI and signal-to-noise ratio differences to better understand the sources of variability in diffusion parameters. According to the Koo and Li classification system, our results demonstrate excellent reproducibility for fractional anisotropy and mean diffusivity across scanners of the same model (ICC ≥ 0.964) when using identical acquisition schemes, pre-processing pipelines and automated ROI segmentation. NODDI orientation dispersion index and neurite density index exhibit a similar level of reproducibility (ICC ≥ 0.942 and ICC ≥ 0.911, respectively), while free water fraction (FWF) has ICC ≥ 0.862. However, statistically significant variability was observed in the FWF, specifically within the left inferior fronto-occipital fasciculus (CoV 9.43%) and optic radiation (CoV 9.95%), even when scanning the same cohort across sites. If there is an error in the signal fraction in one compartment in the NODDI model, the signal fractions from other compartments may likely be misestimated. The reproducibility and variability of diffusion parameters reported in this study provide guidance for future QIB research involving datasets derived from multiple scanners. These findings can help determine whether observed changes in diffusion parameters reflect meaningful biological differences or are highly influenced by measurement variability.
Although several studies have demonstrated that perceptual discrimination of complex scenes relies on an extended hippocampal posteromedial system, we currently have limited insight into the specific functional and structural properties of this system in humans. Here, combining electrophysiological (magnetoencephalography) and advanced microstructural (multishell diffusion magnetic resonance imaging; quantitative magnetization transfer) imaging in healthy human adults (30 females/10 males), we show that both theta power modulation of the hippocampus and fiber restriction/hindrance (reflecting axon packing/myelination) of the fornix (a major input/output pathway of the hippocampus) were independently related to scene, but not face, perceptual discrimination accuracy. Conversely, microstructural features of the inferior longitudinal fasciculus (a long-range occipitoanterotemporal tract) correlated with face, but not scene, perceptual discrimination accuracy. Our results provide new mechanistic insight into the neurocognitive systems underpinning complex scene discrimination, providing novel support for the idea of multiple processing streams within the human medial temporal lobe.
This paper introduces the Welsh Advanced Neuroimaging Database (WAND), a multi-scale, multi-modal imaging dataset comprising in vivo brain data from 170 healthy volunteers (aged 18–63 years), including 3 Tesla (3 T) magnetic resonance imaging (MRI) with ultra-strong (300 mT/m) magnetic field gradients, structural and functional MRI and nuclear magnetic resonance spectroscopy at 3 T and 7 T, magnetoencephalography (MEG), and transcranial magnetic stimulation (TMS), together with trait questionnaire and cognitive data. Data are organised using the Brain Imaging Data Structure (BIDS). In addition to raw data, we provide brain-extracted T1-weighted images, and quality reports for diffusion, T1- and T2-weighted structural data, and blood-oxygen level dependent functional tasks. Reasons for participant exclusion are also included. Data are available for download through our GIN repository, a data access management system designed to reduce storage requirements. Users can interact with and retrieve data as needed, without downloading the complete dataset. Given the depth of neuroimaging phenotyping, leveraging ultra-high-gradient, high-field MRI, MEG and TMS, this dataset will facilitate multi-scale and multi-modal investigations of the healthy human brain.
The lower infrastructure requirements of portable ultra-low field MRI (ULF-MRI) systems have enabled their use in diverse settings such as intensive care units and remote medical facilities. The UNITY Project is an international neuroimaging network harnessing this technology, deploying portable ULF-MRI systems globally to expand access to MRI for studies into brain development. Given the wide range of environments where ULF-MRI systems may operate, there are external factors that might influence image quality. This work aims to introduce the quality control (QC) framework used by the UNITY Project to investigate how robust the systems are and how QC metrics compare between sites and over time. We present a QC framework using a commercially available phantom, scanned with 64 mT portable MRI systems at 17 sites across 12 countries on four continents. Using automated, open-source analysis tools, we quantify signal-to-noise, image contrast, and geometric distortions. Our results demonstrated that the image quality is robust to the varying operational environment, for example, electromagnetic noise interference and temperature. The Larmor frequency was significantly correlated to room temperature, as was image noise and contrast. Image distortions were less than 2.5 mm, with high robustness over time. Similar to studies at higher field, we found that changes in pulse sequence parameters from software updates had an impact on QC metrics. This study demonstrates that portable ULF-MRI systems can be deployed in a variety of environments for multi-center neuroimaging studies and produce robust results.
PURPOSE:Diffusion tensor imaging (DTI) is commonly used in cardiac diffusion magnetic resonance imaging (dMRI). However, the tissue's microstructure (cells, membranes, etc.) restricts the movement of the water molecules, making the spin displacements deviate from Gaussian behavior. This effect may be observed with diffusion kurtosis imaging (DKI) using sufficiently high b-values ( b > 450 s/mm 2 $$ \mathrm{b}>450\kern0.2em \mathrm{s}/{\mathrm{mm}}^2 $$ ), which are presently outside the realm of routine cardiac dMRI due to the limited gradient strength of clinical scanners. The Connectom scanner with G max = 300 mT / m $$ {\mathrm{G}}_{\mathrm{max}}=300\kern0.2em \mathrm{mT}/\mathrm{m} $$ enables high b-values at echo times (TE) similar to DTI on standard clinical scanners, therefore facilitating cardiac DKI in humans. METHODS:Cardiac-gated, second-order motion-compensated dMRI was performed with b max = 1350 s / m m 2 $$ {\mathrm{b}}_{\mathrm{m}\mathrm{ax}}=1350\kern0.2em \mathrm{s}/\mathrm{m}{\mathrm{m}}^2 $$ in 10 healthy volunteers on a 3T MRI scanner with G max = 300 mT / m $$ {\mathrm{G}}_{\mathrm{max}}=300\kern0.2em \mathrm{mT}/\mathrm{m} $$ . The signal was fitted to a cumulant expansion up to and including the kurtosis term, and diffusion metrics such as fractional anisotropy (FA), mean diffusivity (MD), mean kurtosis (MK), axial kurtosis (AK), and radial kurtosis (RK) were calculated. RESULTS:We demonstrate deviation of the signal from monoexponential decay for b-values > 450 s / m m 2 $$ >450\kern0.2em \mathrm{s}/\mathrm{m}{\mathrm{m}}^2 $$ ( MK = 0 . 32 ± 0 . 03 $$ \mathrm{MK}=0.32\pm 0.03 $$ ). Radial kurtosis ( RK = 0 . 35 ± 0 . 04 $$ \mathrm{RK}=0.35\pm 0.04 $$ ) was observed slightly larger than axial kurtosis ( AK = 0 . 27 ± 0 . 02 $$ \mathrm{AK}=0.27\pm 0.02 $$ ), and the difference is statistically significant ( RK - AK = 0 . 08 ± 0 . 04 $$ \mathrm{RK}-\mathrm{AK}=0.08\pm 0.04 $$ , p = 2 e - 4 $$ \mathrm{p}=2\mathrm{e}-4 $$ ). CONCLUSION:This work demonstrates the feasibility of quantifying kurtosis effect in the human heart in vivo (at an echo time shorter than typical TEs reported for cardiac DTI), using high-performance gradient systems (which are 4-8 times stronger than on standard clinical scanners). Our work lays the foundation for exploring new biomarkers in cardiac dMRI beyond DTI.
Although several studies, including our own ([Hodgetts et al., 2015][1]), have demonstrated that perceptual discrimination of complex scenes relies on an extended hippocampal network, distinct from the anterotemporal network supporting the perceptual discrimination of faces, we currently have limited insight into the specific functional and structural properties of these networks. Here, combining electrophysiological (magnetoencephalography, MEG) and microstructural (multi-shell diffusion MRI, dMRI) imaging in healthy human adults, we show that both hippocampal theta power modulation and fibre restriction of the fornix (a major input/output pathway of the hippocampus) independently related to accuracy during scene, but not face, perceptual discrimination. Conversely, inferior longitudinal fasciculus (a long-range occipito-anterotemporal tract) tissue properties correlated with face, but not scene, oddity discrimination accuracy. Our results provide new mechanistic insight into the neurocognitive systems underpinning complex scene and face perception, providing support for multiple-system representation-based accounts of the medial temporal lobe. ### Competing Interest Statement The authors have declared no competing interest. [1]: #ref-62
Psychotic experiences (PEs) occur in 5–10% of the general population and are associated with exposure to childhood trauma and obstetric complications. However, the neurobiological mechanisms underlying these associations are unclear. Using the Avon Longitudinal Study of Parents and Children (ALSPAC), we studied 138 young people aged 20 with PEs ( n = 49 suspected, n = 53 definite, n = 36 psychotic disorder) and 275 controls. Voxel-based morphometry assessed whether MRI measures of grey matter volume were associated with (i) PEs, (ii) cumulative childhood psychological trauma (weighted summary score of 6 trauma types), (iii) cumulative pre/peri-natal risk factors for psychosis (weighted summary score of 16 risk factors), and (iv) the interaction between PEs and cumulative trauma or pre/peri-natal risk. PEs were associated with smaller left posterior cingulate ( p FWE < 0.001, Z = 4.19) and thalamus volumes ( p FWE = 0.006, Z = 3.91). Cumulative pre/perinatal risk was associated with smaller left subgenual cingulate volume ( p FWE < 0.001, Z = 4.54). A significant interaction between PEs and cumulative pre/perinatal risk found larger striatum ( p FWE = 0.04, Z = 3.89) and smaller right insula volume extending into the supramarginal gyrus and superior temporal gyrus ( p FWE = 0.002, Z = 4.79), specifically in those with definite PEs and psychotic disorder. Cumulative childhood trauma was associated with larger left dorsal striatum ( p FWE = 0.002, Z = 3.65), right prefrontal cortex ( p FWE < 0.001, Z = 4.63) and smaller left insula volume in all participants ( p FWE = 0.03, Z = 3.60), and there was no interaction with PEs group. In summary, pre/peri-natal risk factors and childhood psychological trauma impact similar brain pathways, namely smaller insula and larger striatum volumes. The effect of pre/perinatal risk was greatest in those with more severe PEs, whereas effects of trauma were seen in all participants. In conclusion, environmental risk factors affect brain networks implicated in schizophrenia, which may increase an individual’s propensity to develop later psychotic disorders.
IntroductionDiffusion-weighted magnetic resonance spectroscopy (DW-MRS) offers improved cellular specificity to microstructure—compared to water-based methods alone—but spatial resolution and SNR is severely reduced and slow-diffusing metabolites necessitate higher b-values to accurately characterize their diffusion properties. Ultra-strong gradients allow access to higher b-values per-unit time, higher SNR for a given b-value, and shorter diffusion times, but introduce additional challenges such as eddy-current artefacts, gradient non-uniformity, and mechanical vibrations.MethodsIn this work, we present initial DW-MRS data acquired on a 3T Siemens Connectom scanner equipped with ultra-strong (300 mT/m) gradients. We explore the practical issues associated with this manner of acquisition, the steps that may be taken to mitigate their impact on the data, and the potential benefits of ultra-strong gradients for DW-MRS. An in-house DW-PRESS sequence and data processing pipeline were developed to mitigate the impact of these confounds. The interaction of TE, b-value, and maximum gradient amplitude was investigated using simulations and pilot data, whereby maximum gradient amplitude was restricted. Furthermore, two DW-MRS voxels in grey and white matter were acquired using ultra-strong gradients and high b-values.ResultsSimulations suggest T2-based SNR gains that are experimentally confirmed. Ultra-strong gradient acquisitions exhibit similar artefact profiles to those of lower gradient amplitude, suggesting adequate performance of artefact mitigation strategies. Gradient field non-uniformity influenced ADC estimates by up to 4% when left uncorrected. ADC and Kurtosis estimates for tNAA, tCho, and tCr align with previously published literature.DiscussionIn conclusion, we successfully implemented acquisition and data processing strategies for ultra-strong gradient DW-MRS and results indicate that confounding effects of the strong gradient system can be ameliorated, while achieving shorter diffusion times and improved metabolite SNR.
Purpose The use of high-performance gradient systems (i.e., high gradient strength and/or high slew rate) for human MRI is limited by physiological effects (including the elicitation of magnetophosphenes and peripheral nerve stimulation (PNS)). These effects, in turn, depend on the interaction between time-varying magnetic fields and the body, and thus on the participant's position with respect to the scanner's isocenter. This study investigated the occurrence of magnetophosphenes and PNS when scanning participants on a high-gradient (300 mT/m) system, for different gradient amplitudes, ramp times, and participant positions. Methods Using a whole-body 300 mT/m gradient MRI system, a cohort of participants was scanned with the head, heart, and prostate at magnet isocenter and a train of trapezoidal bipolar gradient pulses, with ramp times from 0.88 to 4.20 ms and gradient amplitudes from 60 to 300 mT/m. Reports of magnetophosphenes and incidental reports of PNS were obtained. A questionnaire was used to record any additional subjective effects. Results Magnetophosphenes were strongly dependent on participant position in the scanner. 87% of participants reported the effect with the heart at isocenter, 33% with the head at isocenter, and only 7% with the prostate at isocenter. PNS was most widely reported by participants for the vertical gradient axis (67% of participants), and was the dominant physiological effect for ramp times below 2 ms. Conclusion This study evaluates the probability of eliciting magnetophosphenes during whole-body imaging using an ultra-strong gradient MRI system. It provides empirical guidance on the use of high-performance gradient systems for whole-body human MRI.
Purpose: Heating of gradient coils and passive shim components is a common cause of instability in the B0 field, especially when gradient intensive sequences are used. The aim of the study was to set a benchmark for typical drift encountered during MR spectroscopy (MRS) to assess the need for real-time field-frequency locking on MRI scanners by comparing field drift data from a large number of sites. Method: A standardized protocol was developed for 80 participating sites using 99 3T MR scanners from 3 major vendors. Phantom water signals were acquired before and after an EPI sequence. The protocol consisted of: minimal preparatory imaging; a short pre-fMRI PRESS; a ten-minute fMRI acquisition; and a long post-fMRI PRESS acquisition. Both pre- and post-fMRI PRESS were non-water suppressed. Real-time frequency stabilization/adjustment was switched off when appropriate. Sixty scanners repeated the protocol for a second dataset. In addition, a three-hour post-fMRI MRS acquisition was performed at one site to observe change of gradient temperature and drift rate. Spectral analysis was performed using MATLAB. Frequency drift in pre-fMRI PRESS data were compared with the first 5:20 minutes and the full 30:00 minutes of data after fMRI. Median (interquartile range) drifts were measured and showed in violin plot. Paired t-tests were performed to compare frequency drift pre- and post-fMRI. A simulated in vivo spectrum was generated using FID-A to visualize the effect of the observed frequency drifts. The simulated spectrum was convolved with the frequency trace for the most extreme cases. Impacts of frequency drifts on NAA and GABA were also simulated as a function of linear drift. Data from the repeated protocol were compared with the corresponding first dataset using Pearson's and intraclass correlation coefficients (ICC). Results: Of the data collected from 99 scanners, 4 were excluded due to various reasons. Thus, data from 95 scanners were ultimately analyzed. For the first 5:20 min (64 transients), median (interquartile range) drift was 0.44 (1.29) Hz before fMRI and 0.83 (1.29) Hz after. This increased to 3.15 (4.02) Hz for the full 30 min (360 transients) run. Average drift rates were 0.29 Hz/min before fMRI and 0.43 Hz/min after. Paired t-tests indicated that drift increased after fMRI, as expected (p < 0.05). Simulated spectra convolved with the frequency drift showed that the intensity of the NAA singlet was reduced by up to 26%, 44 % and 18% for GE, Philips and Siemens scanners after fMRI, respectively. ICCs indicated good agreement between datasets acquired on separate days. The single site long acquisition showed drift rate was reduced to 0.03 Hz/min approximately three hours after fMRI. Discussion: This study analyzed frequency drift data from 95 3T MRI scanners. Median levels of drift were relatively low (5-min average under 1 Hz), but the most extreme cases suffered from higher levels of drift. The extent of drift varied across scanners which both linear and nonlinear drifts were observed.
Neuroimaging offers a valuable insight into human brain development by allowing in vivo assessment of structure, connectivity and function. Multimodal neuroimaging data have been obtained as part of three sub-studies within the Avon Longitudinal Study of Parents and Children, a prospective multigenerational pregnancy and birth cohort based in the United Kingdom. Brain imaging data were acquired when offspring were between 18 and 24 years of age, and included acquisition of structural, functional and magnetization transfer magnetic resonance, diffusion tensor, and magnetoencephalography imaging. This resource provides a unique opportunity to combine neuroimaging data with extensive phenotypic and genotypic measures from participants, their mothers, and fathers.
We provide a rich multi-contrast microstructural MRI dataset acquired on an ultra-strong gradient 3T Connectom MRI scanner comprising 5 repeated sets of MRI microstructural contrasts in 6 healthy human participants. The availability of data sets that support comprehensive simultaneous assessment of test-retest reliability of multiple microstructural contrasts (i.e., those derived from advanced diffusion, multi-component relaxometry and quantitative magnetisation transfer MRI) in the same population is extremely limited. This unique dataset is offered to the imaging community as a test-bed resource for conducting specialised analyses that may assist and inform their current and future research. The Microstructural Image Compilation with Repeated Acquisitions (MICRA) dataset includes raw data and computed microstructure maps derived from multi-shell and multi-direction encoded diffusion, multi-component relaxometry and quantitative magnetisation transfer acquisition protocols. Our data demonstrate high reproducibility of several microstructural MRI measures across scan sessions as shown by intra-class correlation coefficients and coefficients of variation. To illustrate a potential use of the MICRA dataset, we computed sample sizes required to provide sufficient statistical power a priori across different white matter pathways and microstructure measures for different statistical comparisons. We also demonstrate whole brain white matter voxel-wise repeatability in several microstructural maps. The MICRA dataset will be of benefit to researchers wishing to conduct similar reliability tests, power estimations or to evaluate the robustness of their own analysis pipelines.
Neuroimaging offers a valuable insight into human brain development by allowing in vivo assessment of structure, connectivity and function. Multimodal neuroimaging data have been obtained as part of three sub-studies within the Avon Longitudinal Study of Parents and Children, a prospective multigenerational pregnancy and birth cohort based in the United Kingdom. Brain imaging data were acquired when offspring were between 18 and 24 years of age, and included acquisition of structural, functional and magnetization transfer magnetic resonance, diffusion tensor, and magnetoencephalography imaging. This resource provides a unique opportunity to combine neuroimaging data with extensive phenotypic and genotypic measures from participants, their mothers, and fathers.
Is motor response inhibition supported by a specialised neuronal inhibitory control mechanism, or by a more general system of action updating? This pre-registered study employed a context-cueing paradigm requiring both inhibitory and non-inhibitory action updating in combination with functional magnetic resonance imaging to test the specificity of responses under different updating conditions, including the cancellation of actions. Cortical regions of activity were found to be common to multiple forms of action updating. However, functional specificity during response inhibition was observed in the anterior right inferior frontal gyrus. In addition, fronto-subcortical activity was explored using a novel contrast method. These exploratory results indicate that the specificity for response inhibition observed in right prefrontal cortex continued downstream and was observed in right hemisphere subcortical activity, while left hemisphere activity was associated with right-hand response execution. Overall, our findings reveal both common and distinct correlates of response inhibition in prefrontal cortex, with exploratory analyses supporting putative models of subcortical pathways and extending them through the demonstration of lateralisation.
Diffusion MRI is being used increasingly in studies of the brain and other parts of the body for its ability to provide quantitative measures that are sensitive to changes in tissue microstructure. However, inter-scanner and inter-protocol differences are known to induce significant measurement variability, which in turn jeopardises the ability to obtain 'truly quantitative measures' and challenges the reliable combination of different datasets. Combining datasets from different scanners and/or acquired at different time points could dramatically increase the statistical power of clinical studies, and facilitate multi-centre research. Even though careful harmonisation of acquisition parameters can reduce variability, inter-protocol differences become almost inevitable with improvements in hardware and sequence design over time, even within a site. In this work, we present a benchmark diffusion MRI database of the same subjects acquired on three distinct scanners with different maximum gradient strength (40, 80, and 300 mT/m), and with 'standard' and 'state-of-the-art' protocols, where the latter have higher spatial and angular resolution. The dataset serves as a useful testbed for method development in cross-scanner/cross-protocol diffusion MRI harmonisation and quality enhancement. Using the database, we compare the performance of five different methods for estimating mappings between the scanners and protocols. The results show that cross-scanner harmonisation of single-shell diffusion data sets can reduce the variability between scanners, and highlight the promises and shortcomings of today's data harmonisation techniques.
Precuneus/posterior cingulate cortex (PCu/PCC) are key components of a midline network, activated during rest but also in tasks that involve construction of scene or situation models. Despite growing interest in PCu/PCC functional alterations in disease, the underlying neurochemical modulators of PCu/PCC’s task-induced activity are largely unstudied. Here, a multimodal imaging approach was applied to investigate whether inter-individual differences in PCu/PCC fMRI activity, elicited during perceptual discrimination of scene stimuli, were correlated with local brain metabolite levels, measured during resting-state 1 H-MRS. Forty healthy young adult participants (12 male) completed an fMRI perceptual odd-one-out task for scenes, objects and faces. 1 H-MRS metabolites N-acetyl-aspartate (tNAA), glutamate (Glx) and γ-amino-butyric acid (GABA+) were quantified via PRESS and MEGA-PRESS scans in a PCu/PCC voxel and an occipital (OCC) control voxel. Whole brain fMRI revealed a cluster in right dorsal PCu/PCC that showed a greater BOLD response to scenes versus faces and objects. When extracted from an independently defined PCu/PCC region of interest, scene activity (versus faces and objects and also versus baseline) was positively correlated with PCu/PCC, but not OCC, tNAA. A complementary fMRI analysis restricted to the PCu/PCC MRS voxel area identified a significant PCu/PCC cluster, confirming the positive correlation between scene-related BOLD activity and PCu/PCC tNAA. There were no correlations between PCu/PCC fMRI activity and Glx or GABA+ levels. These results demonstrate, for the first time, that scene activity in PCu/PCC is linked to local tNAA levels, identifying a neurochemical influence on inter-individual differences in the task-driven activity of a key brain hub.