Tuning a complex multi-loop PID based control system requires considerable experience. In today's power industry the number of available qualified tuners is dwindling and there is a great need for better tuning tools to maintain and improve the performance of complex multivariable processes. Multi-loop PID tuning is the procedure for the online tuning of a cluster of PID controllers operating in a closed loop with a multivariable process. This paper presents the first application of the simultaneous tuning technique to the multi-input-multi-output (MIMO) PID based nonlinear controller in the power plant control context, with the closed-loop system consisting of a MIMO nonlinear boiler/turbine model and a nonlinear cluster of six PID-type controllers. Although simplified, the dynamics and cross-coupling of the process and the PID cluster are similar to those used in a real power plant. The particular technique selected, iterative feedback tuning (IFT), utilizes the linearized version of the PID cluster for signal conditioning, but the data collection and tuning is carried out on the full nonlinear closed-loop system. Based on the figure of merit for the control system performance, the IFT is shown to deliver performance favorably comparable to that attained through the empirical tuning carried out by an experienced control engineer.
Future industrial use of wireless instrumentation will undoubtedly increase dramatically in the coming years. Deployment of such instrumentation in an industrial setting - with its security and robustness criteria that are much more stringent than residential performance criteria - hinges on user acceptance of verified performance as well as meeting cost requirements. Today, circa 2011, these industrial users are faced with many choices when specifying a wireless sensor network, including radio performance, battery life, interoperability concerns, and standards compliance. With industrial users standing on the precipice to order and deploy (literally) millions of wireless instruments, it is imperative that accurate information for applying the technology to real-world applications be available to the end-user.
As equipment ages in fossil-fueled power plants, component wear leading to machinery failure increases as a result. Extending equipment life requires increased attention to maintenance, and one way to improve maintenance planning is to detect faults prior to failure so maintenance can be scheduled at the most cost-effective, opportune time. This type of strategy benefits from the use of additional sensors, and wireless ones can often be installed with the least time and cost.
Multi-input-multi-output robust controllers recently designed for the megawatt output/throttle pressure control in a coal-fired power plant boiler/turbine unit have demonstrated performance robustness noticeably superior to that of the currently employed nonlinear PID-based controller. These controllers, however, have been designed only for the range of 150–185MW around the 185MW nominal operating point, exhibiting a significant loss of performance in the lower range of 120–150MW. Through system identification, the reason for this performance loss is demonstrated in the current work to be a pronounced dependence of the boiler/turbine unit steady state gains on the operating point. This problem is addressed via a hybrid control law consisting of two robust controllers and a robust switch between them activated by the set point change. The controllers are designed to cover the corresponding half-ranges of the full operating range. This permits attainment of the desired overall performance as well as reduction of modeling uncertainty induced by the operating point change to approximately 25% of that associated with the previous designs. Robust switching is accomplished through a novel hybrid mode of behavior—robustly controlled discrete transition. The latter mode is produced through realizing that the off-line transfer speedup suggested by Zaccarian and Teel (2005, “The L2(l2) bumpless Transfer Problem for Linear Parts: Its Definition and Solution,” Automatica, 41, pp. 1273–1280) can be taken to the limit and incorporating the result into a robust bumpless transfer technique recently developed by the authors. As demonstrated by simulation results, the proposed strategy provides an adequate solution to the problem of robust boiler/turbine unit performance over the full operating range. This fact combined with numerical algorithm tractability, relative ease of its design, its insensitivity to implementation nonidealities, and accompanying identification methodology for nominal model generation makes it a viable candidate for industrial acceptance.
A complete design and implementation methodology for the steady state bumpless controller transfer under controller uncertainty is presented. The off-line transfer speedup idea of Zaccarian and Teel is formalized to yield an implementation technique that completely eliminates the need for any performance/robustness trade-off in the transfer operator design and provides arbitrarily fast convergence of the offline controller output to that of the online one, removing a key obstacle to acceptance by practitioners of the technique proposed