The UCNA experiment was designed to measure the neutron β-asymmetry parameter A_0 using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the spectrometer. A value for A_0 was then extracted from the asymmetry in the numbers of counts in the two detector packages. We summarize all of the results from the UCNA experiment, obtained during run periods in 2007, 2008–2009, 2010, and 2011–2013, which ultimately culminated in a 0.67% precision result for A_0.
Directly laser driven and X-radiation driven DT filled capsules differ in the relationship between neutron and X-ray images. Shot N110217, a directly driven DT-filled glass micro-balloon provided the first neutron images at the National Ignition Facility. As seen in implosions on the Omega laser, the neutron image can be enclosed inside time integrated X-ray images. HYDRA simulations show the X-ray image is dominated by emission from the hot glass shell while the neutron image arises from the DT fuel it encloses. In the absence of mix or jetting, X-ray images of a cryogenically layered THD fuel capsule should be dominated by emission from the hydrogen rather than the cooler plastic shell that is separated from the hot core by cold DT fuel. This cool, dense DT, invisible in X-ray emission, shows itself by scattering hot core neutrons. Germanium X-ray emission spectra and Ross pair filtered X-ray energy resolved images suggest that germanium doped plastic emits in the torus shaped hot spot, probably reducing the neutron yield.
The accuracy of density measurements and position resolution in flash (40 ns) radiography of thick objects with 24 Gev/c protons is investigated. A global model fit to step wedge data is shown to give a good description spanning the periodic table. The parameters obtained from the step wedge data are used to predict transmission through the French Test Object (FTO), a test object of nested spheres, to a precision better than 1%. Multiple trials have been used to show that the systematic errors are less than 2%. Absolute agreement between the average radiographic measurements of the density and the known density is 1%. Spatial resolution has been measured to be 200 μm at the center of the FTO. These data verify expectations of the benefits provided by high energy hadron radiography for thick objects.
The design, construction, and performance of a type of sealed 3He drift tubes for neutron detection are presented. Because the 3He pressure is in the 25–300mbar range, the detector costs are not dominated by the 3He gas. Intrinsic neutron detection efficiencies up to 5% have been observed by using high-density polyethylene moderation. Sensitive measurements of the detector lifetime are achieved by monitoring the full-energy peak of the 3He(n, p)3H reaction as a function of time. The neutron peak position shows a 24-h cycle that may be explained by the physical adsorption of gases onto the wall. The estimated lifetimes of the detectors are sufficiently long and therefore, the design and the construction are robust and practical for applications such as fissile material detection.
We report the first measurement of an angular correlation parameter in neutron beta decay using polarized ultracold neutrons (UCN). We utilize UCN with energies below about 200 neV, which we guide and store for approximately 30 s in a Cu decay volume. The interaction of the neutron magnetic dipole moment with a static 7 T field external to the decay volume provides a 420 neV potential energy barrier to the spin state parallel to the field, polarizing the UCN before they pass through an adiabatic fast passage spin flipper and enter a decay volume, situated within a 1 T field in a 2x2pi solenoidal spectrometer. We determine a value for the beta-asymmetry parameter A_{0}=-0.1138+/-0.0046+/-0.0021.
Over 120 million vehicles enter the United States each year. Many are capable of transporting hidden nuclear weapons or nuclear material. Currently deployed X-ray radiography systems are limited because they cannot be used on occupied vehicles and the energy and dose are too low to penetrate many cargos. We present a new technique that overcomes these limitations by obtaining tomographic images using the multiple scattering of cosmic radiation as it transits each vehicle. When coupled with passive radiation detection, muon interrogation could contribute to safe and robust border protection against nuclear devices or material in occupied vehicles and containers.
A new search for a permanent electric dipole moment (EDM) of the neutron is underway using ultracold neutrons produced and held in a bath of superfluid helium. Attaining the target sensitivity requires maintaining an electric field of several tens of kilovolts per centimeter across the experimental cell, which is nominally 7.5 cm wide and will contain about 4 liters of superfluid. The electrical properties of liquid helium are expected to be sufficient to meet the design goals, but little is known about these properties for volumes and electrode spacings appropriate to the EDM experiment. Furthermore, direct application of the necessary voltages from an external source to the experimental test cell is impractical. An apparatus to amplify voltages in the liquid helium environment and to test the electrical properties of the liquid for large volumes and electrode spacings has been constructed. The device consists of a large-area parallel plate capacitor immersed in a 200 liter liquid helium dewar. Preliminary results show the breakdown strength of normal state liquid helium is at least 90 kV/cm at these volumes, at the helium vapor pressure corresponding to 4.38 K. These fields hold for more than 11 hours with leakage currents less than 170 pA (about 20% of the maximum tolerable in the EDM experiment). The system is also found to be robust against anticipated radiation backgrounds. Preliminary results for superfluid show that fields of at least 30 kV/cm can be sustained at the volumes required for the EDM experiment, about 60% of the design goal. These results are likely limited by the low pressure that must be maintained above the superfluid bath.
We describe a neutron radiography technique that can be used to map the distribution of 3He impurities in liquid 4He, providing direct and quantitative access to underlying transport processes. Images reflecting finite normal- and superfluid-component 4He velocity fields are presented.
The PHENIX Muon Arms detect muons at rapidities of |y|=(1.2–2.4) with full azimuthal acceptance. Each muon arm must track and identify muons and provide good rejection of pions and kaons (∼10−3). In order to accomplish this we employ a radial field magnetic spectrometer with precision tracking (Muon Tracker) followed by a stack of absorber/low resolution tracking layers (Muon Identifier). The design, construction, testing and expected run parameters of both the muon tracker and the muon identifier are described.
We have used a neutron radiography technique to investigate the spatial distribution of 3He atoms in very dilute liquid 3He–4He mixtures at temperatures below the superfluid transition temperature. By imposing heat currents and monitoring the subsequent redistribution of 3He within the sample volume we obtain a direct measurement of the relevant mass diffusion coefficient. Data from these experiments provides a striking demonstration of the manner in which the distribution of impurity atoms within the liquid can be influenced by the presence of a free surface.
The PHENIX detector is designed to perform a broad study of A–A, p–A, and p–p collisions to investigate nuclear matter under extreme conditions. A wide variety of probes, sensitive to all timescales, are used to study systematic variations with species and energy as well as to measure the spin structure of the nucleon. Designing for the needs of the heavy-ion and polarized-proton programs has produced a detector with unparalleled capabilities. PHENIX measures electron and muon pairs, photons, and hadrons with excellent energy and momentum resolution. The detector consists of a large number of subsystems that are discussed in other papers in this volume. The overall design parameters of the detector are presented.
The role of 3He-3He collisions in our diffusion experiment is addressed and shown to not be relevant to the measurement of 3He diffusion against phonons in superfluid helium.
We have used a neutron radiography technique to investigate the spatial distribution of 3 He atoms in very dilute liquid 3 He- 4 He mixtures at temperatures below the superfluid transition temperature. By imposing heat currents and monitoring the subsequent redistribution of 3 He within the sample volume we obtain a direct measurement of the relevant mass diffusion coefficient. Data from these experiments provides a striking demonstration of the manner in which the distribution of impurity atoms within the liquid can be influenced by the presence of a free surface.