Immunocompatibility of gelatin-based hydrogels to be applied as implant coatings for local regenerative treatment has been studied. First, the bio- and immuno-acceptability of the methacrylamide-modified gelatin hydrogels per se was screened. The results indicated that the hydrogels support cell growth. Metabolic activity of normal cells and permanent cell lines representing various cell types (endothelial, epithelial, fibroblast, and monocyte/macrophage) cultivated on the gelatin hydrogels was moderately lower compared to cells cultivated on tissue culture plastic. The cells cultivated on the hydrogels produced identical cytokines as the control cells although at lower levels. Importantly, no inflammatory activity, measured by nitric oxide and pro-inflammatory cytokine (IL-1α, IL-6, and TNFα) production, was observed in peritoneal cells and monocyte/macrophage RAW 264.7 cell line cultivated on the hydrogels. Finally, polyimide (PI) implantable membranes were surface-modified with gelatin hydrogels and screened for their in vivo immunocompatibility. Their histological examination performed after subcutaneous implantation in mice produced a sound proof of immunoacceptability. Normal tissue repair, mild cellular infiltration and edema mainly induced by the surgery were observed after 2 and 6 days. No adverse tissue responses were induced by the implants. Analysis performed after 4 and 9 weeks indicated areas of foreign body granuloma without formation of a fibrous capsule.
An electronic sensor system for urinary bladder pressure monitoring requires an imbedding into a biocompatible, flexible, and liquid-impermeable material. Poly(dimethylsiloxane) (PDMS) was selected in the present set-up as packaging material because it fulfills the abovementioned requirements. However, the surface of PDMS is hydrophobic and causes undesired interactions with salts, proteins, and cells present in urine. To reduce possible interactions of urine salts in the urinary bladder, monomers, [2-(methacryloyloxy)ethyl]-dimethyl-3-sulfopropyl-ammonium hydroxide (sulfobetaine) and 2-acrylamido-2-methylpropyl sulfonic acid, were grafted onto the surface through oxygen plasma treatment. A reduction in salt deposition between the pure PDMS and the modified PDMS was observed both in vitro (artificial urine flow over the surface) and in vivo (implants into the urinary bladder of experimental pigs). Additionally, a 10-fold reduction in salt deposition was observed in vitro due to grafting of the monomers onto the surface. These modified PDMS materials proved also to be biocompatible in cell cultures, which was further confirmed by histological screening of the bladder tissue after implantation in an in vivo pig model.
In this study we chemospecifically functionalized alginate with thiol-ended peptides for tissue engineering (TE): a carbodiimide linker and the disulfide exchange scheme were used. First carboxyls of alginate were activated by introducing N-hydroxysuccinimide (NHS) ester groups; these react with primary amines of the heterobifunctional reagent 2-(2-pyridyldithio)ethyleneamine (PDEA). Thiol-reactive alginate (alginate-S-S-py) forms as cross-linking intermediate. The degree of pyridyldithio-functionalization is modified through variable PDEA concentration and it was determined using UV-VIS spectroscopy and proton nuclear magnetic resonance. The applicability of the alginate-S-S-py as platform for the chemoselective coupling of thiol-encled peptides was tested with glutathione as model peptide. Other SH-terminal peptides were successfully cross-linked. Moreover, the peptide-alginate keeps its gel-forming ability when treated with Ca2+ cations, leading to functionalized hydrogels that can be further used to obtain different multicomponent systems. The developed chemoselective strategy of functionalizing alginate with thiol-ended peptides could enhance the potential of this polymer for TE. (C) 2012 Elsevier Ltd. All rights reserved.
A new strategy for the synthesis of polyamides from polyesters of hydroxyl-containing amino acids using a multi O-N acyl transfer reaction was developed. This original approach allowed the synthesis of three generations of polymers from the same starting monomer. The polymerization of N-benzyloxycarbonyl-serine and its γ-homologated derivative provided the Z-protected polyesters; then the water-soluble polycationic polyesters were obtained by removal of the Z-protecting group; and finally the polyamides were obtained by a base-induced multi O-N acyl transfer, both in aqueous or organic medium. The key step transfer reaction was monitored by the disappearance and appearance of characteristic NMR proton signals and IR bands of polyesters and polyamides.
The metal of choice to treat critical size bone defects are up to today still titanium (Ti) and its alloys. These biometals possess advantageous characteristics for bone tissue engineering applications. Despite the strong biocompatibility the bone binding capacity and the bioactivity of Ti are not sufficient to realise a true bond between the implant and the surrounding bone tissue, implying a nonoptimal osseointegration. In the present work, we studied the immobilisation of the biopolymer gelatin type B onto the surface of three dimensional regular Ti scaffolds to improve their surface bio-activity.
In the present work, the development of imprinted polymers selective towards mycophenolic acid and their application in food analysis are reported for the first time. To synthesize the molecularly imprinted polymer (MIP) 4-vinylpyridine and ethyleneglycol dimethacrylate were applied as functional monomer and cross-linker, respectively. Besides the toxin itself, the implementation of structural analogues as templates was evaluated. A molecularly imprinted solid-phase extraction (MISPE) procedure was designed for the selective clean-up of maize extracts. Binding experiments and Scatchard analysis indicated the presence of specific binding sites in the imprinted polymers. The imprinting effect varied along with the selected template. The dissociation constant (K(D)) of the higher affinity binding sites ranged from 0.8 μmol/l to 15.6 μmol/l, while the K(D) of the lower affinity binding sites was in the range of 138.5-519.3 μmol/l. The performance of the MIPs throughout the clean-up of spiked maize sample extracts was evaluated and compared with the results obtained when applying a non-imprinted polymer. Depending on the polymers and the spiked concentration, recoveries after MISPE and non-imprinted solid-phase extraction varied respectively from 49% to 84% and from 28% to 31%. The imprinted polymers were superior regarding matrix effect, limit of detection (LOD) and limit of quantification (LOQ). LOD ranged from 0.17 μg/kg to 0.25 μg/kg and LOQ varied from 0.57 μg/kg to 0.82 μg/kg. Analysis of 15 maize samples by liquid chromatography tandem mass spectrometry revealed that the MIPs could be excellent sorbents for clean-up of contaminated food samples.
The presence of polyamine groups on the surface of dielectrics potentially improves the adhesion with electrochemically deposited metals. In this article, first cyanuric chloride is covalently bound to the surface hydroxyl groups of the epoxy resin. The remaining reactive sites on the coupled cyanuric chloride molecule are the used to anchor polyamines. The surface reactions are monitored and characterized by means of ATR-IR, SEM-EDS, XPS and ToF-SIMS.
Pluronic® F127 is a biocompatible, injectable, and thermoresponsive polymer with promising biomedical applications. In this study, a chemically modified form, i.e., Pluronic ALA-L with tailored degradation rate, was tested as an encapsulation vehicle for osteoblastic cells. UV cross-linking of the modified polymer results in a stable hydrogel with a slower degradation rate. Toxicological screening showed no adverse effects of the modified Pluronic ALA-L on the cell viability. Moreover, high viability of embedded cells in the cross-linked Pluronic ALA-L was observed with life/death fluorescent staining during a 7-day-culture period. Cells were also cultured on macroporous, cross-linked gelatin microbeads, called CultiSpher-S® carriers, and encapsulated into the modified cross-linked hydrogel. Also, in this situation, good cell proliferation and migration could be observed in vitro. Preliminary in vivo tests have shown the formation of new bone starting from the injected pre-loaded CultiSpher-S® carriers.
Hydrogels are physically or chemically cross-linked polymer networks that are able to absorb large amounts of water. They can be classified into different categories depending on various parameters including the preparation method, the charge, and the mechanical and structural characteristics. The present review aims to give an overview of hydrogels based on natural polymers and their various applications in the field of tissue engineering. In a first part, relevant parameters describing different hydrogel properties and the strategies applied to finetune these characteristics will be described. In a second part, an important class of biopolymers that possess thermosensitive properties (UCST or LCST behavior) will be discussed. Another part of the review will be devoted to the application of cryogels. Finally, the most relevant biopolymer-based hydrogel systems, the different methods of preparation, as well as an in depth overview of the applications in the field of tissue engineering will be given.
A new concept of top-down electrospinning is described. A dedicated apparatus was designed including the adaptation of a movable needle system in combination with a thin conveyor belt made of an insulation material on the top of the grounded collector plate. The new design, termed 'needle printing', permits to electrospin mats with increased size, homogeneous and controllable thicknesses. Due to the increase of bending instability and to the 'needle printing', the produced fibres are more regular in shape, longer and are deposited more stretched. In contrast to traditional electrospinning, the fibre population is the same in all regions of the mats imparting the same morphological and mechanical properties to each point of the produced structures.
The present work reports on the synthesis and evaluation of a crosslinkable thiolated gelatin derivative. The effect of varying two parameters including the pH of the reaction buffer and the thiolating agent applied (i.e. N-acetylhomocysteine thiolactone versus Traut’s reagent) on the obtained modification degree was studied in a first part. The gelatin derivatives synthesized starting from N-acetylhomocysteine thiolactone and Traut’s reagent were characterized in depth using size exclusion chromatography and UV–VIS spectrophotometry. In a subsequent part of the present work, hydrogel films were prepared starting from the thiolated gelatin derivative developed using N-acetylhomocysteine thiolactone. The contributions of both the chemical and the physical crosslinking of the hydrogels developed were studied in depth using rheology, swelling experiments and texturometry. The results indicate that the physical structuring, inherent to gelatin, contributes to a large extent to the mechanical properties. However, the chemical crosslinking mostly determines the final hydrogel properties and can be controlled to a large extent. The gelatin-based gels are flexible, strong and transparent. A major advantage of disulfide-crosslinked hydrogels is the fact that the crosslinking is reversible. The latter could be interesting in view of future applications as cell carriers for tissue engineering.
The vast majority of studies in the bone tissue engineering field are focused on the surface modification of titanium scaffolds to obtain integration of the scaffold in the surrounding bone tissue. Our approach consisted in benefiting from the advantages of the cell-interaction capabilities of collagen and gelatin. The biopolymers were immobilised onto the Ti surface through different methods and the stability of the obtained coatings was determined. The obtained results reveal that covalent immobilisation of collagen and gelatin is required to obtain stable surface coatings.
There is a lack of methods suitable for generation of data about the dynamics of effects on cell membranes with a high sensitivity. Such methods are urgently needed to support the optimisation of interaction of substances, particles or materials with cell. The goal of this article is to use an improved microhole chip system to monitor the alterations of cells due to the interactions of polymer–DNA complexes. This should demonstrate exemplarily that subtoxic effect of biological relevant particles or substances at relevant concentrations can be monitored for several hours. By using a microhole cell chip and a microfluidic unit single cells can be electrically interfaced via microholes and the use of small electrodes with high impedances is not necessary. For separation and positioning of the cells onto the hole negative pressure is applied on the reverse side of the chip. Under cell culture conditions the cell starts to spread on the biocompatible insulating chip membrane resulting in a stable interface to an adherent growing cell. After the spreading process is finished, the polymer/polyplex solution is added and the impedance is measured with respect to time. To illustrate the cellular parameter which can affect the measured impedance a simple simulation based on the finite element method (FEM) is performed. It was shown for the first time that the impedance-based method predicated on the microhole chip can be used for biological relevant substances at relevant concentrations and that it is more sensitive than the well-established biological marker.
Polydimethylsiloxane (PDMS) is an elastomer that is widely used in construction and for biological and biomedical applications. The biocompatibility of PDMS was improved by different surface treatment methods, i.e., plasma treatment or a combination of plasma treatment with UV-irradiation or redox initiator, to minimize the effects of deposition of salts and proteins. In this work we used the vinyl monomers sulfobetaine and AMPS which have good biocompatible properties.
Subretinal implants aim to replace the photoreceptor function in patients suffering from degenerative retinal disease by topically applying electrical stimuli in the subretinal space. Critical obstacles in the design of high-resolution subretinal implants include the proximity of stimulating electrodes to the target cells and enabling nutrient flow between the retina and the choroid. The present work evaluates the adhesion, migration and survival of retinal cells on an ultrathin (5 μm), highly porous (Ø 1 μm spaced 3 μm), gelatin-coated polyimide (PI) membrane. The biocompatibility was examined in mice indicating a good tolerance upon subcutaneous implantation with only a mild inflammatory response. In addition, organotypic cultures of rat retina evidenced that the porous membrane allowed the necessary nutrient flow for the retinal cell survival and maintenance. A transscleral implantation technique was applied to position the membrane into the subretinal space of rats. The effect on the obtained retinal integration was investigated in vivo using scanning laser ophthalmoscopy (SLO) and optical coherence tomography (OCT). In 12 out of 18 rat eyes, the implant was successfully placed subretinally. SLO and OCT demonstrated complete retinal attachment and fluorescein angiography showed no retinal vascular abnormalities over and around the implant, immediately after and up to four weeks after the implantation. Histological examination of the eyes showed a close attachment of a thin fibrocyte layer to the implant, the occlusion of the pores by living cells and the survival of some photoreceptors at the implantation site.