A collaborative trial was conducted to determine the performance characteristics of an analytical method for the quantification of inorganic arsenic (iAs) in food.The method is based on (i) solubilisation of the protein matrix with concentrated hydrochloric acid to denature proteins and allow the release of all arsenic species into solution, and (ii) subsequent extraction of the inorganic arsenic present in the acid medium using chloroform followed by back-extraction to acidic medium. The final detection and quantification is done by flow injection hydride generation atomic absorption spectrometry (FI-HG-AAS).The seven test items used in this exercise were reference materials covering a broad range of matrices: mussels, cabbage, seaweed (hijiki), fish protein, rice, wheat, mushrooms, with concentrations ranging from 0.074 to 7.55mgkg−1.The relative standard deviation for repeatability (RSDr) ranged from 4.1 to 10.3%, while the relative standard deviation for reproducibility (RSDR) ranged from 6.1 to 22.8%.
The Institute for Reference Materials and Measurements (IRMM) of the Joint Research Centre (JRC), a Directorate General of the European Commission, operates the International Measurement Evaluation Program (IMEP). IMEP organises inter-laboratory comparisons in support of European Union policies. This paper presents the results of two proficiency tests (PTs): IMEP-116 and IMEP-39, organised for the determination of total Cd, Pb, As, Hg and inorganic As (iAs) in mushrooms. Participation in IMEP-116 was restricted to National Reference Laboratories (NRLs) officially appointed by national authorities in European Union member states. IMEP-39 was open to all other laboratories wishing to participate. Thirty-seven participants from 25 countries reported results in IMEP-116, and 62 laboratories from 36 countries reported for the IMEP-39 study. Both PTs were organised in support to Regulation (EC) No. 1881/2006, which sets the maximum levels for certain contaminants in food. The test item used in both PTs was a blend of mushrooms of the variety shiitake (Lentinula edodes). Five laboratories, with demonstrated measurement capability in the field, provided results to establish the assigned values (Xref). The standard uncertainties associated to the assigned values (uref) were calculated by combining the uncertainty of the characterisation (uchar) with a contribution for homogeneity (ubb) and for stability (ust), whilst uchar was calculated following ISO 13528. Laboratory results were rated with z- and zeta (ζ)-scores in accordance with ISO 13528. The standard deviation for proficiency assessment, σp, ranged from 10% to 20% depending on the analyte. The percentage of satisfactory z-scores ranged from 81% (iAs) to 97% (total Cd) in IMEP-116 and from 64% (iAs) to 84% (total Hg) in IMEP-39.
The Institute for Reference Materials and Measurements (IRMM) of the Joint Research Centre (JRC), a Directorate-General of the European Commission, operates the International Measurement Evaluation Programme® (IMEP). It organises various types of inter-laboratory comparisons in support of European Union policies. This paper presents the results of a proficiency testing exercise (PT) focusing on the determination of total cadmium (Cd) and total lead (Pb) mass fractions in baby food in support to Commission Regulation (EC) 1881/2006 of 19 December 2006 setting maximum levels for certain contaminants in foodstuffs. The test material used in this exercise was soya-based baby food formula purchased in a local pharmacy and prepared by the Reference Materials Unit of the IRMM for this exercise. Sixty-six laboratories from 23 countries registered to the exercise and 61 of them reported results. Each participant received one bottle containing approximately 15 g of test material. Participants were asked to quantify the measurands in the powder and in the reconstituted formula. Reference values independent from the participants’ results were established using isotope dilution inductively coupled plasma mass spectrometry. The total Cd mass fraction was determined by IRMM and LGC Ltd (UK), while the total Pb was determined by IRMM. The standard deviation for proficiency assessment was set at 22% of the assigned value for all measurands. Laboratories were rated with z- and ζ- (zeta) scores in accordance with ISO 13528. The outcome of this exercise is clearly influenced by the very low level of Cd and Pb content in the test material which triggered: a high number of ‘less than’ values; overestimated values especially for Pb very likely due to contamination; and a visible method influence in the case of Pb (methods based on atomic absorption were not sensitive enough to attain such low limits of detection). The results were also evaluated with regard to the reported limit of detection and some incoherencies were observed.
Two of the core tasks of the European Union Reference Laboratory for Heavy Metals in Feed and Food (EU-RL-HM) are to provide advice to the Directorate General for Health and Consumers (DG SANCO) on scientific matters and to organise proficiency tests among appointed National Reference Laboratories. This article presents the results of the 12th proficiency test organised by the EU-RL-HM (IMEP-112) that focused on the determination of total and inorganic arsenic in wheat, vegetable food and algae. The test items used in this exercise were: wheat sampled in a field with a high concentration of arsenic in the soil, spinach (SRM 1570a from NIST) and an algae candidate reference material. Participation in this exercise was open to laboratories from all around the world to be able to judge the state of the art of the determination of total and, more in particular, inorganic arsenic in several food commodities. Seventy-four laboratories from 31 countries registered to the exercise; 30 of them were European National Reference Laboratories. The assigned values for IMEP-112 were provided by a group of seven laboratories expert in the field of arsenic speciation analysis in food. Laboratory results were rated with z and ζ scores (zeta scores) in accordance with ISO 13528. Around 85 % of the participants performed satisfactorily for inorganic arsenic in vegetable food and 60 % did for inorganic arsenic in wheat, but only 20 % of the laboratories taking part in the exercise were able to report satisfactory results in the algae test material.
In 2008, the International Measurement Evaluation Programme, IMEP®, organised two proficiency tests (PTs) for the determination of heavy metals in mineral feed, named IMEP-105 and IMEP-27, respectively. IMEP-105 was organised in support of the activities of the European Union Reference Laboratory for Heavy Metals in Feed and Food, and participation was restricted to the officially nominated National Reference Laboratories (NRLs). IMEP-27 was open to all interested control laboratories in the field. The test material used in the two PTs was the same and the timeframe of the two exercises overlapped. The measurands in both exercises were total Cd, Pb and As and extractable Cd and Pb, as defined in Directive 2002/32/EC of the European Parliament and the Council on undesirable substances in animal feed. Forty-nine laboratories from 25 countries reported results to the two exercises, 29 to IMEP-105 and 20 to IMEP-27. In both PTs, external reference values were used instead of consensus values derived from the participants' results. It was shown that the concentration of total and extractable Cd according to Directive 2002/32/EC were identical, while the concentration of extractable Pb was ~80% of total Pb. The main outcome of these comparisons was that an underestimation of the concentrations of the addressed measurands, in particular total Pb, took place due to an erroneous estimation of the bias of the analytical methods used by most of the participants. It appeared that the nature of the certified reference materials chosen for method validation and recovery estimation was the cause of the problem (insufficient matching of the matrix characteristics between these materials and the test sample). No significant difference between the results reported to IMEP-105 and to IMEP-27 was observed.