To test the hypothesis that single-photon emission computed tomography (SPECT) could actually determine left ventricular LV mass in humans, SPECT measurements of LV mass were compared with LV mass determined by cineangiography in 12 patients with normal coronary arteries and LV function. Repeat SPECT determinations of LV mass were carried out in 5 patients. Projection images of the left ventricle were acquired after intravenous injection of thallium-201 (TI-201) using a rotating gamma camera. Transverse sections were reconstructed by filtered backprojection. The boundary of LV uptake of TI-201 in each transverse section was defined using a 3-dimensional threshold detector. Scintigraphic LV mass (total number of voxels demonstrating LV TI-201 uptake X voxel volume X specific gravity of myocardium) was compared with angiographic LV mass. There was good correlation between LV mass determined by SPECT and that determined by cineangiography. Mean angiographic LV mass was 208 +/- 45 g (+/- standard deviation). Mean SPECT LV mass was 204 +/- 42 g. Linear regression analysis revealed the following relation: SPECT LV mass = 0.76 X angiographic LV mass + 46.1 (r = 0.82, root-mean-square deviation from regression = 24.7). The SPECT values of LV mass varied an average of 10.4 +/- 4.6% (+/- standard deviation) in the 5 patients in whom 2 determinations were made. Thus, SPECT of TI-201 can accurately measure LV mass in humans.
Single photon-emission computed tomography (SPECT) with 99mTc-pyrophosphate (PPi) has been shown to estimate size of myocardial infarction accurately in animals. We tested the hypothesis that SPECT with 99mTc-PPi and blood pool subtraction can provide prompt and accurate estimates of size of myocardial infarction in patients. SPECT estimates are potentially available early after the onset of infarction and should correlate with estimates of infarct size calculated from serial measurements of plasma MB-creatine kinase (CK) activity. Thirty-three patients with acute myocardial infarction and 16 control patients without acute myocardial infarction were studied. Eleven of the patients had transmural anterior myocardial infarction, 16 had transmural inferior myocardial infarction, and six had nontransmural myocardial infarction. SPECT was performed with a commercially available rotating gamma camera. Identical projection images of the distribution of 99mTc-PPi and the ungated cardiac blood pool were acquired sequentially over 180 degrees. Reconstructed sections were color coded and superimposed for purposes of localization of infarct. Areas of increased PPi uptake within myocardial infarcts were thresholded at 65% of peak activity. The blood pool was thresholded at 50% and subtracted to determine the endocardial border for the left ventricle. Myocardial infarcts ranged in size from 1 to 126 gram equivalents (geq) MB-CK. The correlation of MB-CK estimates of size of infarct with size determined by SPECT (both in geq) was good (r = .89 with a regression line of y = 13.1 + 1.5x).(ABSTRACT TRUNCATED AT 250 WORDS)