Colorectal cancer represents a global health burden, being the third most fre-quently diagnosed cancer worldwide, counting about 1.9 million new cases annually, and the second leading cause of cancer-related deaths, counting over 900,000 deaths per year. These figures highlight the urgent need for innovative and non-invasive methods for early detection to improve current diagnostic approaches. In this study, two nanostructured chemoresistive gas sensors based on tin oxide–titanium oxide compo-sites were selected to detect the metabolic patterns associated with human healthy and colorectal cancer tissues. As an additional validation of the biopsy-derived results, the sensors were tested on two colorectal cancer-derived cell lines, namely Caco-2 and RKO. Both sensors demonstrated a clear ability to discriminate between healthy and cancerous samples, with discrimination powers of 11% and 8%, respectively. These results were further confirmed by principal component analysis (PCA), which showed a reasonable separation between healthy and cancerous samples in both the PC1–PC2 and PC1–PC3 score plots and a hierarchical clustering approach for cell samples. While these sensors cannot identify the specific metabolites associated with cancerous tissue, they outlined a characteristic volatile fingerprint of the samples, enabling reliable dis-crimination between healthy and tumor samples.
Colorectal cancer represents a global health burden, being the third most frequently diagnosed cancer worldwide, accounting for about 1.9 million new cases annually, and the second leading cause of cancer-related deaths. This highlights the need for innovative and effective methods for cancer detection, improving current diagnostic approaches. In this feasibility study, two nanostructured chemoresistive gas sensors based on tin oxide-titanium oxide composites were selected to detect the metabolic patterns associated with human healthy and colorectal cancer tissues, collected from 26 patients. To further validate the biopsy-derived results, the sensors were tested on two colorectal cancer-derived cell lines, namely Caco-2 and RKO. Both sensors were able to discriminate between healthy and tumor samples by comparing the mean sensor responses, using the paired t-test (p-value = 0.00018), and by using an LDA, achieving a cross-validated accuracy of 0.73. Moreover, the ROC analysis performed on the data projected along the discriminant direction led to an AUC of 0.83. Finally, the sensors exhibited distinct response profiles to Caco-2 and RKO exhalations, as expected given their different biological features. As a proof-of-feasibility study, these findings demonstrate that these sensors could capture a characteristic volatile fingerprint distinguishing the samples, although they cannot identify the specific cancer metabolites.
Head movements are detected and signalled to primary sensory neurons by vestibular types I and II hair cells. Signal transmission involves glutamate exocytosis from hair cells, which is triggered by Ca2+ inflow through voltage-gated CaV1.3 Ca2+ channels. In a previous study on mice, we reported a Ca2+-dependent exocytosis in both hair cell types, measured as a sustained change in cell membrane capacitance (ΔCm) following cell depolarization, which was significantly smaller in type I than in type II hair cells. By contrast, only type I hair cells showed a large transient ΔCm, which was still present in CaV1.3-/- mouse type I hair cells. Here we investigated the nature of this transient ΔCm. We found that it was unaffected by 10 mm intracellular EGTA, which blocked most of the sustained exocytosis in these cells, demonstrating its insensitivity to intracellular Ca2+. Moreover the amplitude of the transient ΔCm correlated with the degree of activation of the low-voltage activated outward rectifying K+ conductance, GK,L, expressed by type I, but not type II hair cells. Finally the sign and kinetics of the transient ΔCm changed based on voltage steps activating or deactivating GK,L. These findings are consistent with the transient ΔCm arising from the mobilization of charges during the gating of K,L channels, while excluding fast transient neurotransmitter exocytosis. Its large amplitude can be explained by the high resistance of the calyceal synaptic cleft since it was significantly reduced in Caspr-/- mice, which show a significantly larger synaptic cleft compared to wild type mice. KEY POINTS: Vestibular type I and type II hair cells signal head movement to the central nervous system. Signal transmission from both hair cell types relies on Ca2+-dependent glutamate exocytosis, measured here as a sustained change in cell membrane capacitance (ΔCm). Type I hair cells exhibit also a large transient ΔCm, whose nature has not been elucidated. In this study we found that the transient ΔCm does not involve exocytosis, but it is generated by the gating of the low-voltage activated outward rectifying K+ conductance, specifically expressed in type I hair cells. Transient ΔCm analysis (also carried out in mice lacking the core protein of the septate-like junction) conclusively demonstrates that type I hair cells, like type II ones, do not elicit a transient release of neurotransmitter. Knowledge of the basic mechanisms of vestibular signalling is crucial in the study of pharmacological treatment for vestibular disorders and in the drug side effects targeted there.
Colorectal cancer represents 10% of all the annual tumors diagnosed worldwide, being often not timely diagnosed, because its symptoms are typically lacking or very mild. Therefore, it is crucial to develop and validate innovative low-invasive techniques to detect it before becoming intractable. To this aim, a device equipped with nanostructured gas sensors has been employed to detect the airborne molecules of blood samples collected from healthy subjects, and from colorectal cancer affected patients at different stages of their pre- and post-surgery therapeutic path. Data was scrutinized by using statistical standard techniques to highlight their statistical differences, and through principal component analysis and support vector machine to classify them. The device was able to readily distinguish between the pre-surgery blood samples (i.e., taken when the patient had cancer), and the ones up to three years post-surgery (i.e., following the tumor removal) or the ones from healthy subjects. Finally, the correlation of the sensor responses with the patient/healthy subject’s gender was investigated, resulting negligible. These results pave the path toward a clinical validation of this device to monitor the patient’s health status by detecting possible relapses, to parallel to clinical follow-up protocols.
Background: Pimozide is a conventional antipsychotic drug of the diphenylbutylpiperidine class, widely used for treating schizophrenia and delusional disorders and for managing motor and phonic tics in Tourette’s syndrome. Pimozide is known to block dopaminergic D2 receptors and various types of voltage-gated ion channels. Among its side effects, dizziness and imbalance are the most frequently observed, which may imply an effect of the drug on the vestibular sensory receptors, the hair cells. Amniotes possess two classes of vestibular hair cells, named type I and type II hair cells, which differ in terms of signal processing and transmission. We previously reported that Pimozide [3 μM] significantly increased a delayed outward rectifying K+ current (IK,V). Methods and Results: In the present study, using the whole-cell patch-clamp technique we additionally show that Pimozide decreases the inward rectifying K+ current (IK,1) and the mixed Na+/K+ current (Ih) of chicken embryo type II hair cells, whereas it does not affect type I hair cells’ ionic currents. Since ion channels’ expression can vary depending on age and animal species, in the present study, we also tested Pimozide in adult mouse vestibular hair cells. We found that, like in the chicken embryo, Pimozide significantly increases IK,V and decreases IK,1 and Ih in type II hair cells. However, in the adult mouse, Pimozide also slightly increased the outward rectifying K+ current in type I hair cells. Conclusions: While providing a possible explanation for the vestibular side effects of Pimozide in humans, its inhibitory action on mammalian hair cells might be of interest for the local treatment of vestibular disorders characterized by altered vestibular input, like Ménière’s disease.
Humidity is a well-known interference factor in metal oxide (MOX) gas sensors, significantly impacting their performance in various applications such as environmental monitoring and medical diagnostics. This study investigates the effects of adsorbed water on MOX conductivity using two different materials: pure tin oxide (SnO2) and a tin–titanium–niobium oxide mixture (SnTiNb)xO2 (STN). The results reveal that (SnTiNb)xO2 sensors exhibit reduced sensitivity to humidity compared to pure tin oxide, rendering them more suitable for applications where humidity presence is critical. We aimed to shed light on a still controversial debate over the mechanisms involved in the water surface interactions for the aforementioned materials also by exploring theoretical studies in the literature. Experimental analysis involves varying temperatures (100 to 800 °C) to understand the kinetics of surface reactions. Additionally, a brief high-temperature heating method is demonstrated to effectively remove adsorbed humidity from sensor surfaces. The study employs Arrhenius-like plots for graphical interpretation, providing insights into various water adsorption/desorption phenomena. Overall, this research contributes to a deeper understanding of the role of humidity in MOX gas sensor mechanisms and offers practical insights for sensor design and optimization.
Nowadays, most medical-diagnostic, environmental monitoring, etc. devices employ sensors whose fabrication reproducibility and response repeatability assessment are crucial. The former consists of large-scale sensor manufacture through a standardized process with almost identical morphology and behavior, while the latter consists of giving the same response upon repeating the same stimulus. The thermo-activated chemoresistive sensors, which change their conductance by interacting with the molecules composing the surrounding gas, are currently employed in many devices: in particular, thick-film (SnTiNb)O2 nanosensors were demonstrated to be particularly suitable in the medical and biological fields. Therefore, a set of thirteen of them, randomly selected from the same screen-printing deposition, were laboratory tested, and the outcomes were statistically analyzed in order to assess their consistency. At first, the working temperature that maximized both the sensor sensitivity and response repeatability was identified. Then, the sensors were subjected to different gas concentrations and humidities at this optimal working temperature. It resulted in the (SnTiNb)O2 nanosensors detecting and discriminating CO concentrations as low as 1 ppm and at high humidity degrees (up to 40%) with high repeatability since the response relative standard error ranged from 0.8 to 3.3% for CO and from 3.6 to 5.4% for water vapor.
Chemoresistive nanostructured gas sensors are employed in many diverse applications in the medical, industrial, environmental, etc. fields; therefore, it is crucial to have a device that is able to quickly calibrate and characterize them. To this aim, a portable, user-friendly device designed to easily calibrate a sensor in laboratory and/or on field is introduced here. The device comprises a small hermetically sealed chamber (containing the sensor socket and a temperature/humidity sensor), a pneumatic system, and a custom electronics controlled by a Raspberry Pi 4 developing board, running a custom software (Version 1.0) whose user interface is accessed via a multitouch-screen. This device automatically characterizes the sensor heater in order to precisely set the desired working temperature, it acquires and plots the sensor current-to-voltage and Arrhenius relationships on the touch screen, and it can record the sensor responses to different gases and environments. These tests were performed in dry air on two representative sensors based on widely used SnO2 material. The device demonstrated the independence of the Arrhenius plot from the film applied voltage and the linearity of the I–Vs, which resulted from the voltage step length (1–30 min) and temperature (200–550 °C).
Exposure of human lung epithelial cells (A549 cell line) to the oxidant pollutant ozone (O3) alters cell membrane currents inducing its decrease, when the cell undergoes to a voltage-clamp protocol ranging from-90 to +70mV. The membrane potential of these cells is mainly maintained by the interplay of potassium and chloride currents. Our previous studies indicated the ability of O3 to activate ORCC (Outward Rectifier Chloride Channel) and consequently increases the chloride current.In this paper our aim was to understand the response of potassium current to oxidative stress challenge and to identify the kind potassium channel involved in O3 induced current changes.After measuring the total membrane current using an intracellular solution with or without potassium ions, we obtained the contribution of potassium to the overall membrane current in control condition by a mathematical approach. Repeating these experiments after O3 treatment we observed a significant decrease of Ipotassium. Treatment of the cells with Iberiotoxin (IbTx), a specific inhibitor of BK channel, we were able to verify the presence and the functionality of BK channels. In addition, the administration of 4-Aminopyridine (an inhibitor of voltage dependent K channels but not BK channels) and Tetraethylammonium (TEA) before and after O3 treatment we observed the formation of BK oxidative post-translation modifications.Our data suggest that O3 is able to inhibit potassium current by targeting BK channel. Further studies are needed to better clarify the role of this BK channel and its interplay with the other membrane channels under oxidative stress conditions. These findings can contribute to identify the biomolecular pathway induced by O3 allowing a possible pharmacological intervention against oxidative stress damage in lung tissue.
The necessity of detecting and recognizing gases is crucial in many research and application fields, boosting, in the last years, their continuously evolving technology. The basic detection principle of gas sensors relies on the conversion of gas concentration changes into a readable signal that can be analyzed to calibrate sensors to detect specific gases or mixtures. The large variety of gas sensor types is here examined in detail, along with an accurate description of their fundamental characteristics and functioning principles, classified based on their working mechanisms (electrochemical, resonant, optical, chemoresistive, capacitive, and catalytic). This review is particularly focused on chemoresistive sensors, whose electrical resistance changes because of chemical reactions between the gas and the sensor surface, and, in particular, we focus on the ones developed by us and their applications in the medical field as an example of the technological transfer of this technology to medicine. Nowadays, chemoresistive sensors are, in fact, strong candidates for the implementation of devices for the screening and monitoring of tumors (the second worldwide cause of death, with ~9 million deaths) and other pathologies, with promising future perspectives that are briefly discussed as well.
Colorectal cancer (CRC) represents 10% of the annual tumor diagnosis and deaths occurring worldwide. Given the lack of specific symptoms, which could determine a late diagnosis, the research for specific CRC biomarkers and for innovative low-invasive methods to detect them is crucial. Therefore, on the basis of previously published results, some volatile organic compounds (VOCs), detectable through gas sensors, resulted in particularly promising CRC biomarkers, making these sensors suitable candidates to be employed in CRC screening devices. A new device was employed here to analyze the exhalations of blood samples collected from CRC-affected patients at different stages of their pre- and post-surgery therapeutic path, in order to assess the sensor’s capability for discriminating among these samples. The stages considered were: the same day of the surgical treatment (T1); before the hospital discharge (T2); after one month and after 10–12 months from surgery (T3 and T4, respectively). This device, equipped with four different sensors based on different metal–oxide mixtures, enabled a distinction between T1 and T4 with a sensitivity and specificity of 93% and 82%, respectively, making it suitable for clinical follow-up protocols, patient health status monitoring and to detect possible post-treatment relapses.
The detection of volatile organic compounds (VOCs) exhaled by human body fluids is a recent and promising method to reveal tumor formations. In this feasibility study, a patented device, based on nanostructured chemoresistive gas sensors, was employed to explore the gaseous exhalations of tumoral, immortalized, and healthy cell lines, with the aim of distinguishing their VOC patterns. The analysis of the device output to the cell VOCs, emanated at different incubation times and initial plating concentrations, was performed to evaluate the device suitability to identify the cell types and to monitor their growth. The sensors ST25 (based on tin and titanium oxides), STN (based on tin, titanium, and niobium oxides), and TiTaV (based on titanium, tantalum and vanadium oxides) used here, gave progressively increasing responses upon the cell density increase and incubation time; the sensor W11 (based on tungsten oxide) gave instead unreliable responses to all cell lines. All sensors (except for W11) gave large and consistent responses to RKO and HEK293 cells, while they were less responsive to CHO, A549, and CACO-2 ones. The encouraging results presented here, although preliminary, foresee the development of sensor arrays capable of identifying tumor presence and its type.
Some hearing, vestibular, and vision disorders are imputable to voltage-gated Ca2+ channels of the sensory cells. These channels convey a large Ca2+ influx despite extracellular Na+ being 70-fold more concentrated than Ca2+; such high selectivity is lost in low Ca2+, and Na+ can permeate. Since the permeation properties and molecular identity of sensory Ca2+ channels are debated, in this paper, we examine the Na+ current flowing through the L- and R-type Ca2+ channels of labyrinth hair cells. Ion currents and cytosolic free Ca2+ concentrations were simultaneously monitored in whole-cell recording synchronous to fast fluorescence imaging. L-type and R-type channels were present with different densities at selected sites. In 10 nM Ca2+, the activation and deactivation time constants of the L-type Na+ current were accelerated and its maximal amplitude increased by 6-fold compared to physiological Ca2+. The deactivation of the R-type Na+ current was not accelerated, and its current amplitude increased by 2.3-fold in low Ca2+; moreover, it was partially blocked by nifedipine in a voltage- and time-dependent manner. In conclusion, L channel gating is affected by the ion species permeating the channel, and its selectivity filter binds Ca2+ more strongly than that of R channel; furthermore, external Ca2+ prevents nifedipine from perturbing the R selectivity filter.
User-friendly, low-cost equipment for preventive screening of severe or deadly pathologies are one of the most sought devices by the National Health Services, as they allow early disease detection and treatment, often avoiding its degeneration. In recent years more and more research groups are developing devices aimed at these goals employing gas sensors. Here, nanostructured chemoresistive metal oxide (MOX) sensors were employed in a patented prototype aimed to detect volatile organic compounds (VOCs), exhaled by blood samples collected from patients affected by colorectal cancer and from healthy subjects as a control. Four sensors, carefully selected after many years of laboratory tests on biological samples (cultured cells, human stools, human biopsies, etc.), were based here on various percentages of tin, tungsten, titanium, niobium, tantalum and vanadium oxides. Sensor voltage responses were statistically analyzed also with the receiver operating characteristic (ROC) curves, that allowed the identification of the cut-off discriminating between healthy and tumor affected subjects for each sensor, leading to an estimate of sensitivity and specificity parameters. ROC analysis demonstrated that sensors employing tin and titanium oxides decorated with gold nanoparticles gave sensitivities up to 80% yet with a specificity of 70%.
Despite the great progress in screening techniques and medical treatments, colorectal cancer remains one of the most widespread cancers in both sexes, with a high death rate. In this work, the volatile compounds released from human colon cancer tissues were detected by a set of four different chemoresistive sensors, made with a nanostructured powder of metal-oxide materials, inserted into an innovative patented device. The sensor responses to the exhalation of a primary cancer sample and of a healthy sample (both of the same weight, collected during colorectal surgery from the intestine of the same patient) were statistically analyzed. The sensors gave reversible, reproducible, and fast responses for at least one year of continuous use, making them quite superior in respect to the existing diagnostic methods. Preliminary results obtained using principal component analysis of the sensor responses to samples removed from 13 patients indicate that the nanostructured sensors employed in this study were able to distinguish between healthy and tumor tissue samples with coherent responses (the discrimination power of the most sensitive sensor was about 17%), highlighting a strong potential for clinical practice.
Preventive screening does not only allow to preemptively intervene on pathologies before they can harm the host; but also to reduce the costs of the intervention itself; boosting the efficiency of the NHS (National Health System) by saving resources for other purposes. To improve technology advancements in this field; user-friendly yet low-cost devices are required; and various applications for gas sensors have been tested and proved reliable in past studies. In this work; cell cultures and blood samples have been studied; using nanostructured chemoresistive sensors; to both verify if this technology can reliably detect tumor markers; and if correlations between responses from tumor line metabolites and the screening outcomes on human specimens could be observed. The results showed how sensors responded differently to the emanations from healthy and mutant (for cells) or tumor affected (for blood) samples, and how those results were consistent between them, since the tumoral specimens had higher responses compared to the ones of their healthy counterparts. Even though the patterns in the responses require a bigger population to be defined properly; it appeared that the different macro-groups between the same kind of samples are distinguishable from some of the sensors chosen in the study; giving promising outcomes for further research.
To understand the working principles of the nervous system is key to figure out its electrical activity and how this activity spreads along the neuronal network. It is therefore crucial to develop advanced techniques aimed to record in real time the electrical activity, from compartments of single neurons to populations of neurons, to understand how higher functions emerge from coordinated activity. To record from single neurons, a technique will be presented to fabricate patch pipettes able to seal on any membrane with a single glass type and whose shanks can be widened as desired. This dramatically reduces access resistance during whole-cell recording allowing fast intracellular and, if required, extracellular perfusion. To simultaneously record from many neurons, biocompatible probes will be described employing multi-electrodes made with novel technologies, based on diamond substrates. These probes also allow to synchronously record exocytosis and neuronal excitability and to stimulate neurons. Finally, to achieve even higher spatial resolution, it will be shown how voltage imaging, employing fast voltage-sensitive dyes and two-photon microscopy, is able to sample voltage oscillations in the brain spatially resolved and voltage changes in dendrites of single neurons at millisecond and micrometre resolution in awake animals.
One of the greatest goals in medicine is early-stage tumor detection. An effective prevention is crucial to allow physicians and surgeons to intervene on patients with the available therapies, usually successful on small volume cancers only. The purpose of this research relies on the identification of cancer presence by detecting the volatile organic biomarkers directly produced by cancer cells. Cancer cell biomarkers are different by the ones exhaled by healthy cells and this difference can be recognized by means of a specific chemoresistive sensor array. In this study, a fast-responding, reliable and reproducible sensing technique proved to discriminate cancerous from healthy cells, making it an efficient low invasive screening system. The device employed, named SCENT B1 [1] combines a specific electronic and pneumatic system to a sensor core made of four nanostructured chemoresistive metal-oxide sensors (nanograins with average size of 40-50 nm) manufactured in the Sensor Laboratory of the University of Ferrara. The sample is inserted inside a specific sample box in a specific support composed by Petri dishes, while an ambient airflow, humidity stabilized, conveys the exhalations to sensors. Sensors responses are then analyzed by principal component analysis (PCA). Measurements have been performed on cancer and healthy tissues extracted during surgery from human colon and rectum, with the future aim of extending the study to the other type of tumors. Neoplastic tissues exhibit altered metabolic processes with respect to the metabolism of healthy cells, therefore the chemicals (metabolites) expelled during cellular respiration depend upon the cell health status. Sensors chosen to compose the array have been selected after a feasibility study performed on immortalized cells of diverse types, correlating also sensors responses with cell concentration inside the Petri dish (after 24, 48, 72 hours of incubation). Sensors chosen are: a mixture of tin and titanium oxides with addition of gold (ST25Au), tungsten oxide (W11), a mixture of tin, titanium and niobium oxides (STN) and a solid solution of titanium oxide, tantalum and vanadium (TiTaV). The voltage output of each sensor is directly proportional to its conductance, that depends on the chemical reactions happening on sensor surface [2,3]. In Figure (a) the response R=DG/G for each sensor is reported, where DG is the difference between the sensor conductance with and without the metabolites expelled by the cells of a tissue. All four sensors gave larger responses (although with different amplitudes) to the tumor tissue with respect to the healthy one. Smaller responses were given by the breeding ground (DMEM) only, confirming that it does not alter the measurement. Results are consistent with the stronger metabolism of tumor cells with respect to the healthy ones, because the former emits larger amounts of volatile biomarkers [4,5]. Other tests proved also that different initial plating concentrations (250k, 500k and 1M) of cell give increasing responses, as shown in Figure (b). From this study what emerges is that the the device is capable of distinguishing different cell samples basing on their health status and concentrations, laying the foundation for a deepen study for the clinical validation of the device as a oncologic screening device. References SCENT B1, Italian Patent Number: 102015000057717; Zonta, G. Anania, B. Fabbri, A. Gaiardo, S. Gherardi, A. Giberti, V. Guidi, N. Landini, C. Malagù; “Detection of colorectal cancer biomarkers in the presence of interfering gases”; Sensors and Actuators B 218 (2015), 289–295; Zonta, G. Anania, B. Fabbri, A. Gaiardo, S. Gherardi, A. Giberti, N. Landini, C. Malagù, L. Scagliarini, V. Guidi, Preventive screening of colorectal cancer with a device based on chemoresistive sensors. Sensors and Actuators B, 238, 1098–110, 2016. F. Altomare, M. Di Lena, F. Porcelli, L. Trizio, E. Travaglio, M. Tutino, S. Dragonieri, V. Memeo, G. de Gennaro; “Exhaled volatile organic compounds identify patients with colorectal cancer”; British Journal of Surgery 100 (2013), 144-150; Chan, E.C.Y., Koh, P.K., Mal, M., Cheah, P.Y., Eu, K.W., Backshall, A., Cavill, R., Nicholson, J.K., Keun, H.C., 2009. “Metabolic Profiling of Human Colorectal Cancer Using High-Resolution Magic Angle Spinning Nuclear Magnetic Resonance (HR-MAS NMR) Spectroscopy and Gas Chromatography Mass Spectrometry (GC/MS)”, Journal of Proteome Research 8(1), 352–361; Figure 1