The 511 keV electron-positron annihilation feature near the galactic center has been detected for more than half a century, yet its origin remains a mystery. We describe a concept for a balloon-borne 511 keV gamma-ray mission called the 511-Spectrometer Mission. The mission will use transition-edge sensor (TES) arrays with thick metal absorbers that are thermally coupled to the TES. The strength of the approach is a projected energy resolution of 200-eV full-width half maximum (FWHM) at 511 keV, enabling detailed studies of the shape and substructure of the 511 keV emission from the galactic center region. A first mission equipped with 8192 gamma-ray detectors and a fully active shield and collimator could detect the galactic center with 35 sigma statistical significance. We present the mission concept as well as the first results obtained with a prototype detector equipped with 1.35 & times;1.35 & times;2 mm(3) Bi absorbers. The detector has a quantum efficiency of 15% for 511 keV photons in photoelectric effect interactions. In tests with a Cs-137 source, these prototype detectors show an energy resolution of 525 eV FWHM at 662 keV. We end with a discussion of follow-up missions that use coded mask imaging or use concentrating or focusing optics to scrutinize the sources of 511 keV gamma-rays on smaller angular scales.
We present the electro-thermal characterization of transition-edge sensor (TES) detectors suspended on Si membranes fabricated using a silicon-on-insulator (SOI) wafer. The use of an all-silicon fabrication platform, in contrast to the more commonly used silicon nitride membranes, is compatible with monolithic fabrication of integrated TES and SQUID circuits. The all-silicon architecture additionally allows efficient use of focal plane area; the readout circuitry may be positioned out of the focal plane by bending a thinned portion of the chip. Compatibility with integrated fabrication and efficient use of focal plane area provide a path to an efficient soft X-ray spectrometer. This work is motivated by our goal to develop a 10,000-pixel TES spectrometer to overcome critical measurement limitations in catalysis research. The characterization of fragile, carbon-based intermediates via techniques like Resonant Inelastic X-ray Scattering (RIXS) is often precluded by the slow, high-flux nature of existing technologies. The new instrument will allow for fast RIXS measurements to be made without causing sample damage. We verify the detector models and measure the energy resolution using a pulsed optical laser, demonstrating the viability of this approach for the final instrument to be deployed at the National Synchrotron Light Source II (NSLS-II).
Ultra-high energy resolution microcalorimeter gamma-ray spectroscopy—with energy resolution 5 to 10 times better than observed in spectra obtained by commercial-off-the-shelf high purity germanium detectors—is an enabling technology for ultra-precise isotope identification and quantification. Microcalorimeter gamma spectroscopy complements measurements requiring high-accuracy mass spectrometry, a costly, destructive analysis technique, and may offer benefits over mass spectrometry in the future. Microcalorimeter detectors are fabricated from superconducting materials and operate at ultra-low temperatures (<0.1 K), properties which permit measurement of spectra with peak full width half maximum (FWHM) of less than 100 eV at 100 keV. The microcalorimeter collaboration between Los Alamos National Laboratory, National Institute of Standards and Technology, and University of Colorado, Boulder has deployed three microcalorimeter gamma-ray spectrometers to nuclear facilities and analytical laboratories so far. These are the Spectrometer Optimized for Facility Integrated Applications (SOFIA), a portable system that can be moved to any facility, and two instruments called the High Efficiency and Resolution Microcalorimeter Spectrometers (HERMES) intended for permanent installation at Idaho National Laboratory and Pacific Northwest National Laboratory. Each spectrometer was customized to satisfy requirements for their specific applications. This work describes samples examined by microcalorimeter gamma-ray spectrometers, including recently irradiated materials, nuclear material from various stages of the fuel cycle, and medical isotope products. It also highlights useful signatures from actinide and fission product gamma-rays that are otherwise infeasible to observe or use for analysis without costly chemical separations and mass spectrometric assay. Microcalorimeter technology provides additional spectral signatures to existing techniques to better constrain the origin and intended use of nuclear and radioactive materials.
Time Division multiplexing (TDM) using superconducting quantum interference devices (SQUIDs) is being developed to read out Transition-edge sensor arrays for the Athena X-ray integral field unit (X-IFU) and Cosmic Microwave Background Stage-4, which have baselined differential TDM architectures. We present the design of symmetric multiplexer circuit read out by a second stage SQUID series array amplifier (SSAA) that has differential input coils that reject the current response to common mode pickup. We present measurements showing that readout with differential input coils has lower EMI susceptibility than with single ended input coils. We also present increases in bandwidth and reductions in crosstalk enabled by related changes to the multiplexer circuit.
A highly charged muonic ion is a unique few-body atomic system where a negatively charged muon and a few electrons are simultaneously bound to a single nucleus. We report the first state-selective observation of highly charged muonic Ar (mu Ar) by electronic K x-ray spectroscopy using an array of transition-edge sensor microcalorimeters. The high-precision K x-ray spectra provide a clear signature of the presence of muonic atoms with one, two, and three electrons, i.e., H-like, He-like, and Li-like mu Ar. With the aid of theoretical calculations, we confirmed that the peak positions are consistent with the x-ray energies from highly charged Cl ions, and the intensities reflect deexcitation dynamics of highly charged mu Ar.
The X-ray spectroscopy of the muonic atom has attracted atomic, nuclear, and particle physicists since its discovery. The properties of a muonic atom, such as its binding energy or atomic radius, are different from an ordinary atom because of the difference in the mass between the muon and electron. Our collaboration has employed superconductor transition-edge sensor (TES) microcalorimeters for the x-ray spectroscopy of the muonic atom. Thanks to the recent detector development, the 44-keV lines from muonic Ar, which is important for the precision test of bound-state quantum electrodynamics, and the 76-keV lines from muonic Si, which is of interest from the viewpoint of the measurement of nuclear radii, have been reached by the dynamic range of the state-of-art TES microcalorimeters. An accelerator facility that can produce a high-intensity muon beam is necessary for such spectroscopic experiments. We performed a commissioning experiment of the hard x-ray and gamma-ray TES microcalorimeter at the J-PARC MLF MUSE muon beam line. The energy resolution, gain stability, and performance of timing selection of the pulses were evaluated in the environment of a large-scale accelerator facility.
This project explores the design and development of a transition edge sensor (TES) spectrometer for resonant soft X-ray scattering (RSXS) measurements developed in collaboration between Argonne National Laboratory (ANL) and the National Institute of Standards and Technology (NIST). Soft X-ray scattering is a powerful technique for studying the electronic and magnetic properties of materials on a microscopic level. However, the lack of high-performance soft X-ray spectrometers has limited the potential of this technique. TES spectrometers have the potential to overcome these limitations due to their high energy resolution, high efficiency, and broad energy range. This project aims to optimize the design of a TES spectrometer for RSXS measurements and more generally soft X-ray spectroscopy at the Advanced Photon Source (APS) 29-ID, leading to improved understanding of advanced materials. We will present a detailed description of the instrument design and implementation. The spectrometer consists of a large array of approximately 250 high-speed and high-resolution pixels. The pixels have saturation energies of approximately 1 keV, sub-ms pulse duration and energy resolution of approximately 1 eV. The array is read out using microwave multiplexing chips with MHz bandwidth per channel, enabling efficient data throughput. To facilitate measurement of samples in situ under ultra-high vacuum conditions at the beamline, the spectrometer is integrated with an approximately 1 m long snout.
The X-ray Integral Field Unit (X-IFU) is an instrument of European Space Agency's future NewAthena space observatory, with the goal to provide high-energy resolution (<4 eV at X-ray energies up to 7 keV) and high-spatial resolution (9 in.) spectroscopic imaging over the X-ray energy range from 200 eV to 12 keV, by means of an array of similar to 1500 transition-edge sensors (TESs) read out via superconducting quantum interference device time-division multiplexing (TDM). A TDM-based laboratory test bed has been assembled at Netherlands Institute for Space Research, hosting an array of 75x75 mu m(2 )TESs that are read out via 2-column x 32-row TDM. A system component that is critical to high-performance operation is the wiring harness that connects the room-temperature electronics to the cryogenic readout componentry. We report here on our characterization of such a test bed, whose harness has a length close to what was envisioned for X-IFU, which allowed us to achieve a co-added energy resolution at a level of 2.7-eV full width half maximum at 6 keV via 32-row readout. In addition, we provide an outlook on the integration of TDM readout into the X-IFU focal plane assembly development model.
The X-ray Integral Field Unit (X-IFU) is an instrument of ESA's future NewAthena space observatory, with the goal to provide high-energy resolution (< 4 eV at X-ray energies up to 7 keV) and high-spatial resolution (9") spectroscopic imaging over the X-ray energy range from 200 eV to 12 keV, by means of an array of about 1500 transition-edge sensors (TES) read out via SQUID time-division multiplexing (TDM). In 2022, to aid in the transfer of TDM readout technology from the laboratory toward flight hardware, our team commissioned a new TDM-based laboratory test-bed at SRON. This setup hosts an array of 75× 75 μm^2 TESs that are read out via 2-column × 32-row TDM. A system component that is critical to high-performance operation is the wiring harness that connects the room-temperature electronics to the cryogenic readout componentry. In November 2023, we implemented a re-designed flex harness, which in the SRON test-bed has a length close to what is envisioned for the X-IFU flight harness. We report here on our characterization of the TDM system with the new flex harness, which allowed the system to achieve a co-added energy resolution at a level of 2.7 eV FWHM at 6 keV via 32-row readout. In addition, we provide an outlook on the upcoming integration of TDM readout into the X-IFU Focal-Plane Assembly Development Model.
X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but it is difficult to implement due to the competing requirements of X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial resolution while addressing the limitations of conventional tomography tools. The instrument combines the electron beam of a scanning electron microscope (SEM) with the precise, broadband X-ray detection of a superconducting transition-edge sensor (TES) microcalorimeter. The electron beam generates a highly focused X-ray spot on a metal target held micrometers away from the sample of interest, while the TES spectrometer isolates target photons with a high signal-to-noise ratio. This combination of a focused X-ray spot, energy-resolved X-ray detection, and unique system geometry enables nanoscale, element-specific X-ray imaging in a compact footprint. The proof of concept for this approach to X-ray nanotomography is demonstrated by imaging 160 nm features in three dimensions in six layers of a Cu-SiO2 integrated circuit, and a path toward finer resolution and enhanced imaging capabilities is discussed.
Time division SQUID multiplexing is being developed as the TES readout technology for the ATHENA X-ray integral field unit and CMB-S4. Close packing of TDM and dc-biased SQUID components is motivated by chip area constraints but has resulted in significant physical neighbor crosstalk in previous generation chips. We present techniques to reduce physical neighbor crosstalk in both linear and two dimensional (2D) TDM chips as well as measurements of crosstalk in these chips.
Superconducting transition-edge sensors (TESs) used in X-ray and γ -ray microcalorimeters suffer degraded performance if cooled in a magnetic field B sufficient to trap flux in the sensors. We report measurements of γ -ray TESs before and after implementing measures to reduce stray B fields from sources inside and outside the cryostat. These measurements showed a correlation between anomalous features in TES current–voltage (IV) curves and degraded energy resolution. After reducing internal sources of stray B field and improving shielding against external sources, both IV curves and energy resolution improved. Finally, we placed magnetized screws with remnant fields ∼ 10 T near similar γ -ray TESs in a different type of detector package and observed the same effects.
HOLMES is an ERC project started in 2014 that will perform a model independent measurement of the neutrino mass with a sensitivity of the order of 1 eV. In order to reach its goal sensitivity, HOLMES will use 1000 low temperature microcalorimeters, each implanted with an activity of 300 Bq of 163Ho, performing thus a calorimetric measurement. This contribution presents the recent results achieved that lay the grounds for the low-activity phase of the HOLMES experiment, that will lead to its first limit on the neutrino mass.
We report on the 1,000-element transition-edge sensor (TES) x-ray spectrometer implementation of the TOMographic Circuit Analysis Tool (TOMCAT). TOMCAT combines a high spatial resolution scanning electron microscope (SEM) with a highly efficient and pixelated TES spectrometer to reconstruct three-dimensional maps of nanoscale integrated circuits (ICs). A 240-pixel prototype spectrometer was recently used to reconstruct ICs at the 130 nm technology node, but to increase imaging speed to more practical levels, the detector efficiency needs to be improved. For this reason, we are building a spectrometer that will eventually contain 3,000 TES microcalorimeters read out with microwave superconducting quantum interference device (SQUID) multiplexing, and we currently have commissioned a 1,000 TES subarray. This still represents a significant improvement from the 240-pixel system and allows us to begin characterizing the full spectrometer performance. Of the 992 maximimum available readout channels, we have yielded 818 devices, representing the largest number of TES x-ray microcalorimeters simultaneously read out to date. These microcalorimeters have been optimized for pulse speed rather than purely energy resolution, and we measure a FWHM energy resolution of 14 eV at the 8.0 keV Cu K$\bm {\alpha}$ line.
Time-division multiplexing (TDM) of transition-edge-sensor (TES) microcalorimeters is being developed as the readout technology for the Athena X-ray integral field unit (X-IFU) and CMB-S4. We present an experimental demonstration of our latest TDM architecture, which has been implemented in a 4-column × 34-row chip that is fully compatible with the X-IFU design specifications. This new “mux21” architecture is designed for differential readout and uses two-layer switches to reduce the number of row-address lines while also incorporating changes that reduce power to roughly 40% and the total number of SQUIDs to half that of TDM chips used in previous publications. With the 160 ns row durations specified for X-IFU, we obtained (2.02 ± 0.03) eV FWHM energy resolution at 5.9 keV in 2-column × 34-row TDM readout of a NASA X-IFU-like TES array, which meets the requirements of X-IFU's energy-resolution budget. Finally, a scaling analysis of our improved TDM readout chain to bolometer applications indicates that multiplexing factors on the scale of several hundred are possible, depending on the readout requirements.
One of the major challenges in nowadays particle physics and astrophysics is the determination of the absolute neutrino mass scale. The HOLMES experiment aims at exploiting the calorimetric approach to directly measure the neutrino mass through the kinematic measurement of the decay products of Ho-163 electron capture (EC). The high energy portion of the calorimetric spectrum of this decay is affected by the non-vanishing neutrino mass value. Given the small fraction of events falling the region of interest, to achieve a high experimental sensitivity on the neutrino mass it is important to have a high activity combined with a very small undetected pile-up contribution. To achieve these targets, the final configuration of HOLMES foresees the deployment of a large number of Ho-163 ion-implanted TESs characterized by an ambitiously high activity of 300 Hz each. This contribution will provide an overview on the HOLMES project with its physics reach and technical challenges together with the status of the major tasks that will bring HOLMES to achieve a statistical sensitivity on the neutrino mass as low as 2 eV.
To test bound-state quantum electrodynamics (BSQED) in the strong-field regime, we have performed high precision x-ray spectroscopy of the 5g-4f and 5f- 4d transitions (BSQED contribution of 2.4 and 5.2 eV, respectively) of muonic neon atoms in the low-pressure gas phase without bound electrons. Muonic atoms have been recently proposed as an alternative to few-electron high-Z ions for BSQED tests by focusing on circular Rydberg states where nuclear contributions are negligibly small. We determined the 5g_{9/2}- 4f_{7/2} transition energy to be 6297.08±0.04(stat)±0.13(syst) eV using superconducting transition-edge sensor microcalorimeters (5.2-5.5 eV FWHM resolution), which agrees well with the most advanced BSQED theoretical prediction of 6297.26 eV.
The 511 keV gamma-ray emission from the galactic center region may fully or partially originate from the annihilation of positrons from dark matter particles with electrons from the interstellar medium. Alternatively, the positrons could be created by astrophysical sources, involving exclusively standard model physics. We describe here a new concept for a 511 keV mission called 511-CAM (511 keV gamma-ray CAmera using Micro-calorimeters) that combines focusing gamma-ray optics with a stack of Transition Edge Sensor (TES) microcalorimeter arrays in the focal plane. The 511-CAM detector assembly has a projected 511 keV energy resolution of 390 eV Full Width Half Maximum (FWHM) or better, and improves by a factor of at least 11 on the performance of state-of-the-art Ge-based Compton telescopes. Combining this unprecedented energy resolution with sub-arcmin angular resolutions afforded by Laue lens or channeling optics could make substantial contributions to identifying the origin of the 511 keV emission by discovering and characterizing point sources and measuring line-of-sight velocities of the emitting plasmas.
We have measured the 3d→2p transition x rays of kaonic ^{3}He and ^{4}He atoms using superconducting transition-edge-sensor microcalorimeters with an energy resolution better than 6 eV (FWHM). We determined the energies to be 6224.5±0.4(stat)±0.2(syst) eV and 6463.7±0.3(stat)±0.1(syst) eV, and widths to be 2.5±1.0(stat)±0.4(syst) eV and 1.0±0.6(stat)±0.3(stat) eV, for kaonic ^{3}He and ^{4}He, respectively. These values are nearly 10 times more precise than in previous measurements. Our results exclude the large strong-interaction shifts and widths that are suggested by a coupled-channel approach and agree with calculations based on optical-potential models.