HOLMES is an ERC project started in 2014 that will perform a model independent measurement of the neutrino mass with a sensitivity of the order of 1 eV. In order to reach its goal sensitivity, HOLMES will use 1000 low temperature microcalorimeters, each implanted with an activity of 300 Bq of 163Ho, performing thus a calorimetric measurement. This contribution presents the recent results achieved that lay the grounds for the low-activity phase of the HOLMES experiment, that will lead to its first limit on the neutrino mass.
One of the major challenges in nowadays particle physics and astrophysics is the determination of the absolute neutrino mass scale. The HOLMES experiment aims at exploiting the calorimetric approach to directly measure the neutrino mass through the kinematic measurement of the decay products of Ho-163 electron capture (EC). The high energy portion of the calorimetric spectrum of this decay is affected by the non-vanishing neutrino mass value. Given the small fraction of events falling the region of interest, to achieve a high experimental sensitivity on the neutrino mass it is important to have a high activity combined with a very small undetected pile-up contribution. To achieve these targets, the final configuration of HOLMES foresees the deployment of a large number of Ho-163 ion-implanted TESs characterized by an ambitiously high activity of 300 Hz each. This contribution will provide an overview on the HOLMES project with its physics reach and technical challenges together with the status of the major tasks that will bring HOLMES to achieve a statistical sensitivity on the neutrino mass as low as 2 eV.
The Lite (Light) satellite for the study of B-mode polarization and Inflation from cosmic background Radiation Detection (LiteBIRD) is a space mission to search for and characterize the signature of inflation in the polarized signal from the cosmic microwave background (CMB), and probe fundamental physics. LiteBIRD will precisely measure the polarization of the cosmic microwave background on large angular scales ≳ 1 deg. It will survey the full sky with three telescopes covering 15 frequency bands centered at frequencies from 40 to 402 GHz. The pixel design for the low- and mid-frequency telescopes features a hemispherical lenslet coupled to a broadband sinuous antenna. The radiation detected by the sinuous antenna propagates through a superconducting microstrip and on-chip bandpass filters before being detected by superconducting transition edge sensor (TES) bolometers. The TES design fulfills requirements for low saturation power of the space environment while maintaining a fast time response for use with a continuously-rotating half-wave plate. We present measurements of the electrical and thermal properties of the TES detectors with values required for the LiteBIRD mission, the design and measurements of a dual-polarization trichroic pixel at 40, 60, and 78 GHz suitable for the low-frequency telescope, and the design and preliminary measurements for a detector array at 100, 140, and 195 GHz suitable for the mid-frequency telescope.
LiteBIRD is a cosmic microwave background polarization experiment with the goal of measuring the tensor-to-scalar ratio with a total uncertainty of $$\delta r <0.001$$. It will survey the full sky from space for 3 years in 15 frequency bands spanning 34–448 GHz. We are developing detector arrays for the six lowest frequency bands covering 34–99 GHz. The arrays are populated with lenslet-coupled sinuous antennas, triplexer bandpass filters, and transition-edge sensor (TES) bolometers. We have measured the electrical and thermal properties of several TES designs to determine space-optimized parameters. The design balances requirements for low saturation power of the space environment while maintaining a fast time response for use with a continuously rotating half-wave plate. We have achieved detector saturation powers below 1 pW, with time constants faster than 1 ms, at a 100 mK bath temperature measured using both time- and frequency-division multiplexed SQUID readout systems. Using this information, we have fabricated multi-chroic pixels with antenna-coupled space-optimized bolometers.
HOLMES is an experiment aiming at performing a direct measurement of the neutrino mass from the electron capture (EC) spectrum of \(^{163}\hbox {Ho}\). In order to reach a sensitivity of the order of \(\sim \)1 eV/c\(^2\) on the neutrino mass, it is necessary to gather as many as \(10^{13}\) events in the 3-year projected live time of HOLMES, keeping the pileup fraction as low as \(10^{-4}\). This is not a trivial matter when it comes to low- temperature calorimeters, which usually have a rather slow time response. At the same time, a large number of detectors need to be operated simultaneously, and hence, in order to avoid an extremely large cryogenic facility, multiplexing is required. In this contribution, I will outline the current status and perspective of HOLMES, with special care devoted to the detectors and readout system, which have currently reached their target performance.
HOLMES is an experiment aimed at directly measuring the neutrino mass through the calorimetric measurement of the Ho-163 electron capture decay. The final goal of the project consists in providing a sensitivity on the neutrino mass below 2 eV; in addition, it will establish the potential of this approach to achieve a sub-eV sensitivity. The detectors performances play a crucial role in achieving the desired sensitivity. Indeed, for such an experiment, the following characteristics are required: short response time (similar to 1 mu s) to solve pile-up events, great energy resolution (similar to 1 eV @ 2.8 keV) and compatibility to be multiplexed in large detector arrays (greater than or similar to 1000). HOLMES will deploy 1000 Transition Edge Sensors which will be readout with the microwave multiplexing technique. In this contribution we outline the experimental setup used in the characterization phase of the detectors.
We present the first performance results obtained with microwave multiplexed Transition Edge Sensors prototypes specifically designed for the HOLMES experiment, a project aimed at directly measuring the electron neutrino mass through the calorimetric measurement of the $$^{163}$$ Ho electron capture spectrum. The detectors required for such an experiment feature a high energy resolution at the Q–value of the transition, around $$\sim $$ 2.8 keV, and a fast response time combined with the compatibility to be multiplexed in large arrays in order to collect a large statistics while keeping the pile-up contribution as small as possible. In addition, the design has to be suitable for future ion-implantation of $$^{163}$$ Ho. The results obtained in these tests allowed us to identify the optimal detector design among several prototypes. The chosen detector achieved an energy resolution of (4.5 ± 0.3) eV on the chlorine K $$_\alpha $$ line, at $$\sim $$ 2.6 keV, obtained with an exponential rise time of 14 $$\upmu $$ s. The achievements described in this paper pose a milestone for the HOLMES detectors, setting a baseline for the subsequent developments, aiming to the actual ion-implantation of the $$^{163}$$ Ho nuclei. In the first section the HOLMES experiment is outlined along with its physics goal, while in the second section the HOLMES detectors are described; the experimental set-up and the calibration source used for the measurements described in this paper are reported in Sects. 3 and 4, respectively; finally, the details of the data analysis and the results obtained are reported in Sect. 6.
Measuring the neutrino mass is one of the most compelling issues in particle physics. HOLMES is an experiment for a direct measurement of the neutrino mass. HOLMES will perform a precise measurement of the end point of the electron capture decay spectrum of \(^{163}\hbox {Ho}\) in order to extract information on the neutrino mass with a sensitivity as low as 1 eV. HOLMES, in its final configuration, will deploy a 1000-pixel array of low-temperature microcalorimeters: each calorimeter is made of an absorber, where the Ho atoms will be implanted, coupled to a transition-edge sensor (TES) thermometer. The detectors will be operated at the working temperature of \(100\,\hbox { mK}\) provided by a dilution refrigerator. In order to read out the 1000-detector array of HOLMES, a multiplexing system is necessary: the choice is to couple the transition-edge sensors to a multiplexed rf-SQUID. In this contribution we outline the progress made towards the final configuration of HOLMES regarding both the performances of the TES detectors and the characteristics of the multiplexing system.
We performed small-scale demonstrations at GSFC of high-resolution X-ray TES microcalorimeters read out using a microwave SQUID multiplexer. This work is part of our effort to develop detector and readout technologies for future space-based X-ray instruments such as the microcalorimeter spectrometer envisaged for Lynx, a large mission concept under development for the Astro 2020 Decadal Survey. In this paper we describe our experiment, including details of a recently designed, microwave-optimized low-temperature setup that is thermally anchored to the 55 mK stage of our laboratory ADR. Using a ROACH2 FPGA at room temperature, we read out pixels of a GSFC-built detector array via a NIST-built multiplexer chip with Nb coplanar waveguide resonators coupled to rf-SQUIDs. The resonators are spaced 6 MHz apart (at \(\sim \) 5.9 GHz) and have quality factors of \(\sim \) 15,000. In our initial demonstration, we used flux-ramp modulation frequencies of 125 kHz to read out 5 pixels simultaneously and achieved spectral resolutions of 2.8–3.1 eV FWHM at 5.9 keV. Our subsequent work is ongoing: to-date we have achieved a median spectral resolution of 3.4 eV FWHM at 5.9 keV while reading out 28 pixels simultaneously with flux-ramp frequencies of 160 kHz. We present the measured system-level noise and maximum slew rates and briefly describe our future development work.
The assessment of neutrino absolute mass scale is still a crucial challenge in today particle physics and cosmology. Beta or electron capture spectrum end-point study is currently the only experimental method which can provide a model-independent measurement of the absolute scale of neutrino mass. HOLMES is an experiment funded by the European Research Council to directly measure the neutrino mass. HOLMES will perform a calorimetric measurement of the energy released in the electron capture decay of the artificial isotope $$^{163}$$ Ho. In a calorimetric measurement, the energy released in the decay process is entirely contained into the detector, except for the fraction taken away by the neutrino. This approach eliminates both the issues related to the use of an external source and the systematic uncertainties arising from decays on excited final states. The most suitable detectors for this type of measurement are low-temperature thermal detectors, where all the energy released into an absorber is converted into a temperature increase that can be measured by a sensitive thermometer directly coupled with the absorber. This measurement was originally proposed by De Rujula and Lusignoli (Nucl Phys B 219:277, 1983. https://doi.org/10.1016/0550-3213(83)90642-9 ), but only in the last decade the technological progress in detectors development has allowed to design a sensitive experiment. HOLMES plans to deploy a large array of low-temperature microcalorimeters with implanted $$^{163}$$ Ho nuclei. In this contribution we outline the HOLMES project with its physics reach and technical challenges, along with its status and perspectives.
The assessment of the neutrino absolute mass scale is still a crucial challenge in today particle physics and cosmology. Beta or electron capture spectrum end-point study is currently the only experimental method which can provide a model independent measurement of the absolute scale of neutrino mass. HOLMES is an experiment to directly measure the neutrino mass by performing a calorimetric measurement of the energy released in the electron capture decay of the artificial isotope 163Ho. In a calorimetric measurement the energy released in the decay process is entirely contained into the detector, except for the fraction taken away by the neutrino. This approach eliminates both the issues related to the use of an external source and the systematic uncertainties arising from decays on excited final states. HOLMES will deploy a large array of low temperature microcalorimeters implanted with 163Ho nuclei. The achievable neutrino mass statistical sensitivity is expected in the eV range, thereby making HOLMES an important step forward in the direct neutrino mass measurement with a calorimetric approach as an alternative to spectrometry. HOLMES will also establish the potential of this approach to achieve a sub-eV sensitivity. HOLMES is designed to collect about 3 × 1013 decays with an instrumental energy resolution around 1 eV FWHM and a time resolution around 1 µs. To achieve this in three years of measuring time, HOLMES is going to deploy 16 sub-arrays of TES microcalorimeters. Each sub-array has 64 pixels ion implanted with 163Ho nuclei to give a pixel activity of 300 Bq per pixel. The TES arrays are read out using microwave multiplexed rf-SQUIDs in combination with a Software Designed Radio data acquisition system. The commissioning of the first implanted sub-array is scheduled for 2018 and it will provide first high statistics data about the EC decay of 163Ho together with a preliminary limit on the neutrino mass. In this contribution we outline the HOLMES project with its physics reach and technical challenges, along with its status and perspectives. In particular we will present the status of the HOLMES activities concerning the 163Ho isotope production by neutron irradiation and purification, the TES pixel design and optimization, the multiplexed array read-out characterization, the cryogenic set-up installation, and the setting up of the mass separation and ion implantation system for the isotope embedding in the TES absorbers.
We performed a small-scale demonstration at GSFC of high-resolution x-ray TES microcalorimeters read out using a microwave SQUID multiplexer. This work is part of our effort to develop detector and readout technologies for future space based x-ray instruments such as the microcalorimeter spectrometer envisaged for Lynx, a large mission concept under development for the Astro 2020 Decadal Survey. In this paper we describe our experiment, including details of a recently designed, microwave-optimized low-temperature setup that is thermally anchored to the 50 mK stage of our laboratory ADR. Using a ROACH2 FPGA at room temperature, we simultaneously read out 32 pixels of a GSFC-built detector array via a NIST-built multiplexer chip with Nb coplanar waveguide resonators coupled to RF SQUIDs. The resonators are spaced 6 MHz apart (at approx. 5.9 GHz) and have quality factors of approximately 15,000. Using flux-ramp modulation frequencies of 160 kHz we have achieved spectral resolutions of 3 eV FWHM on each pixel at 6 keV. We will present the measured system-level noise and maximum slew rates, and briefly describe the implications for future detector and readout design.
State of the art energy-resolving detectors for synchrotrons are required to take full advantage of the capabilities of these facilities. Most spectroscopic applications at x-ray beam-lines require energy resolutions of the order of E/E>1000 and high detection efficiencies, which is beyond the capabilities of both semiconducting detectors and wavelength-dispersive spectrometers. Transition Edge Sensors represent the best candidates for this role by providing high-energy resolution with non-dispersive operation, and with much higher photon-collection efficiency. Recently a novel readout scheme for TESs based on microwave resonators has been introduced by NIST that allows array scalability to high pixel counts. In this work, we describe its application to TESs for x-ray, with particular attention to the optimization of the readout settings. Parameters such noise, linearity and sampling rate represent the benchmarks of this characterization.
Ultra-high resolution microcalorimeter gamma spectroscopy is a new non-destructive assay technology for measurement of plutonium isotopic composition, with the potential to reduce total measurement uncertainty to a level competitive with destructive analysis methods [1-4]. Achieving this level of performance in practical applications requires not only the energy resolution now routinely achieved with transition-edge sensor microcalorimeter arrays (an order of magnitude better than for germanium detectors) but also high throughput. Microcalorimeter gamma spectrometers have not yet achieved detection efficiency and count rate capability that is comparable to germanium detectors, largely because of limits from existing readout technology. Microcalorimeter detectors must be operated at low temperature to achieve their exceptional energy resolution. Although the typical 100 mK operating temperatures can be achieved with reliable, cryogen-free systems, the cryogenic complexity and heat load from individual readout channels for large sensor arrays is prohibitive. Multiplexing is required for practical systems. The most mature multiplexing technology at present is time-division multiplexing (TDM) [3, 5-6]. In TDM, the sensor outputs are switched by applying bias current to one SQUID amplifier at a time. Transition-edge sensor (TES) microcalorimeter arrays as large as 256 pixels have been developed for X-ray and gamma-ray spectroscopy using TDM technology. Due to bandwidth limits and noise scaling, TDM is limited to a maximum multiplexing factor of approximately 32-40 sensors on one readout line [8]. Increasing the size of microcalorimeter arrays above the kilopixel scale, required to match the throughput of germanium detectors, requires the development of a new readout technology with a much higher multiplexing factor.
Assessing the absolute neutrino mass scale is one of the major challenges in particle physics and astrophysics nowadays. A powerful tool to directly estimate the effective electron neutrino mass consists in the calorimetric measurement of the energy released within a nuclear beta decay. The progresses made over the last few decades on low-temperature detector technologies have permitted to design experiments with expected sensitivities on the neutrino mass below 1 eV/c 2 with the calorimetric approach. Despite the remarkable performances in both energy (~ eV at keV) and time resolutions $(\sim\! 1\ \mu\text{s})$ on the single channel, a large number of detectors working in parallel is required to reach a sub-eV sensitivity. Microwave frequency-domain readout provides a powerful technique to read out large arrays of low-temperature detectors, such as transition edge sensors (TESs) or microwave kinetic inductance detectors (MKIDs). In this way, the multiplex factor is only limited by the bandwidth of the available commercial fast digitizers. The microwave multiplexing system will be used to read out the TES array of the HOLMES experiment, which is made of 1000 163 Ho-implanted microcalorimeters. HOLMES is a new experiment that aims to measure the electron neutrino mass by means of the electron capture decay of 163 Ho with an expected sensitivity of the order of the eV/c 2 .
The Atacama Cosmology Telescope Polarimeter (ACTPol) is a polarization sensitive receiver for the 6-m Atacama Cosmology Telescope (ACT) and measures the small angular scale polarization anisotropies in the cosmic microwave background (CMB). The full focal plane is composed of three detector arrays, containing over 3000 transition edge sensors (TES detectors) in total. The first two detector arrays, observing at 146 GHz, were deployed in 2013 and 2014, respectively. The third and final array is composed of multichroic pixels sensitive to both 90 and 146 GHz and saw first light in February 2015. Fabricated at NIST, this dichroic array consists of 255 pixels, with a total of 1020 polarization sensitive bolometers and is coupled to the telescope with a monolithic array of broad-band silicon feedhorns. The detectors are read out using time-division SQUID multiplexing and cooled by a dilution refrigerator at 110 mK. We present an overview of the assembly and characterization of this multichroic array in the lab, and the initial detector performance in Chile. The detector array has a TES detector electrical yield of 85 %, a total array sensitivity of less than 10 \(\upmu \)K\(\sqrt{\text {s}}\), and detector time constants and saturation powers suitable for ACT CMB observations.
Four astrophysics missions are currently being studied by NASA as candidate large missions to be chosen in the 2020 astrophysics decadal survey.(1) One of these missions is the "X-Ray Surveyor" (XRS), and possible configurations of this mission are currently under study by a science and technology definition team (STDT). One of the key instruments under study is an X-ray microcalorimeter, and the requirements for such an instrument are currently under discussion. In this paper we review some different detector options that exist for this instrument, and discuss what array formats might be possible. We have developed one design option that utilizes either transition-edge sensor (TES) or magnetically coupled calorimeters (MCC) in pixel array-sizes approaching 100 kilo-pixels. To reduce the number of sensors read out to a plausible scale, we have assumed detector geometries in which a thermal sensor such a TES or MCC can read out a sub-array of 20-25 individual 1" pixels. In this paper we describe the development status of these detectors, and also discuss the different options that exist for reading out the very large number of pixels.
The absolute neutrino mass scale is still an outstanding challenge in both particle physics and cosmology. The calorimetric measurement of the energy released in a nuclear beta decay is a powerful tool to determine the effective electron-neutrino mass. In the last years, the progress on low temperature detector technologies has allowed to design large scale experiments aiming at pushing down the sensitivity on the neutrino mass below 1 eV. Even with outstanding performances in both energy (~ eV on keV) and time resolution (~ 1 μs) on the single channel, a large number of detectors working in parallel is required to reach a sub-eV sensitivity. Microwave frequency domain readout is the best available technique to readout large array of low temperature detectors, such as Transition Edge Sensors (TESs) or Microwave Kinetic Inductance Detectors (MKIDs). In this way a multiplex factor of the order of thousands can be reached, limited only by the bandwidth of the available commercial fast digitizers. This microwave multiplexing system will be used to readout the HOLMES detectors, an array of 1000 microcalorimeters based on TES sensors in which the 163Ho will be implanted. HOLMES is a new experiment for measuring the electron neutrino mass by means of the electron capture (EC) decay of 163Ho. We present here the microwave frequency multiplex which will be used in the HOLMES experiment and the microwave frequency multiplex used to readout the MKID detectors developed in Milan as well.
Advanced ACTPol (AdvACT) is a third-generation cosmic microwave background receiver to be deployed in 2016 on the Atacama Cosmology Telescope (ACT). Spanning five frequency bands from 25 to 280 GHz and having just over 5600 transition-edge sensor (TES) bolometers, this receiver will exhibit increased sensitivity and mapping speed compared to previously fielded ACT instruments. This paper presents the fabrication processes developed by NIST to scale to large arrays of feedhorn-coupled multichroic AlMn-based TES polarimeters on 150-mm diameter wafers. In addition to describing the streamlined fabrication process which enables high yields of densely packed detectors across larger wafers, we report the details of process improvements for sensor (AlMn) and insulator (SiN\(_x\)) materials and microwave structures, and the resulting performance improvements.
Measuring the neutrino mass is one of the most compelling issues in particle physics. The European Research Council has funded HOLMES, a new experiment for a direct measurement of neutrino mass that started in 2014. HOLMES will perform a precise measurement of the end point of the Electron Capture decay spectrum of \(^{163}\)Ho in order to extract information on neutrino mass with a sensitivity as low as 0.4 eV. HOLMES, in its final configuration, will deploy a 1000 pixel array of low-temperature microcalorimeters: each calorimeter consists of an absorber, where the Ho atoms will be implanted, coupled to a transition edge sensor thermometer. The read out for an array of 1000 cryogenic detectors is a crucial matter: for HOLMES, a special radio-frequency-based multiplexing system is being developed. In this contribution, we outline the performance and special features of the multiplexing system and readout methods chosen for HOLMES.