Recent data show that the quality of anticoagulation evaluated in patients receiving vitamin K antagonists (VKA) is not optimal in France. The aim of this retrospective study was to estimate the performances of six French anticoagulant clinics that manage VKA treatments over a 3-year period, from 2009 to 2011.All clinics used the same rule based software. We determined the time spent in the therapeutic range (TTR), a surrogate end-point of quality of treatment with VKA.The overall duration of follow-up was 2755 patient-years concerning 2385 patients. The time spent in the therapeutic range 2 to 3 assigned for 89% of the patients, was 73%. On the other hand the time spent in the therapeutic range for the other two INR ranges (2.5-3.5 and 3-4.5) concerning 11% of patients with prosthetic heart valve was lower (63.7% and 68.8% respectively) with an imbalance in favour of the time below the range. In this study, warfarin (Coumadine(®)) and fluindione (Previscan(®)) allowed an equivalent quality of anticoagulation. The 1728 patients of age ranged from 60 to 100 years spent more time in TTR than the 651 younger patients. The percentage of time spent with an INR greater than 5 was extremely reduced which is a guarantee of safety.These results prove that anticoagulant clinics in France have the same good performances as their counterparts abroad. It can be assumed that a high TTR contributes to a low incidence of both bleedings and thrombosis.
Purpose. - Recent data show that the quality of anticoagulation evaluated in patients receiving vitamin K antagonists (VKA) is not optimal in France. The aim of this retrospective study was to estimate the performances of six French anticoagulant clinics that manage VKA treatments over a 3-year period, from 2009 to 2011.Methods. - All clinics used the same rule based software. We determined the time spent in the therapeutic range (TTR), a surrogate end-point of quality of treatment with VKA.Results. - The overall duration of follow-up was 2755 patient-years concerning 2385 patients. The time spent in the therapeutic range 2 to 3 assigned for 89% of the patients, was 73%. On the other hand the time spent in the therapeutic range for the other two INR ranges (2.5-3.5 and 3-4.5) concerning 11% of patients with prosthetic heart valve was lower (63.7% and 68.8% respectively) with an imbalance in favour of the time below the range. In this study, warfarin (Coumadine (R)) and fluindione (Previscan (R)) allowed an equivalent quality of anticoagulation. The 1728 patients of age ranged from 60 to 100 years spent more time in TTR than the 651 younger patients. The percentage of time spent with an INR greater than 5 was extremely reduced which is a guarantee of safety.Conclusion. - These results prove that anticoagulant clinics in France have the same good performances as their counterparts abroad. It can be assumed that a high TTR contributes to a low incidence of both bleedings and thrombosis. (C) 2013 Societe nationale francaise de medecine interne (SNFMI). Publie par Elsevier Masson SAS. Tous droits reserves.
The aim of this study was to determine the incidence of congenital toxoplasmosis (CT) and to assess the performances of prenatal and neonatal diagnoses. From 1994-2005, in Toulouse University Hospital, France, amniocentesis was performed on 352 pregnant women who were infected during pregnancy. All women were treated with spiramycin and pyrimethamine-sulfadoxine when prenatal diagnosis was positive. Among the 275 foetuses with follow-up, 66 (24%) were infected. The transmission rates of Toxoplasma gondii were 7%, 24% and 59% in the first, second and third trimesters, respectively. The sensitivity and specificity of PCR on amniotic fluid (AF) were 91% and 99.5%, respectively. One case was diagnosed by mouse inoculation with AF and six cases were diagnosed by neonatal or postnatal screening. The sensitivity and specificity of PCR on placentas were 52% and 99%, respectively. The sensitivity of tests for the detection of specific IgA and IgM in cord blood was 53% and 64%, respectively, and specificity values were 91% and 92%. In conclusion, PCR performed on AF had the highest levels of sensitivity and specificity for the diagnosis of CT. This permits an early diagnosis of most cases and should be recommended.
Le syndrome des anticardiolipides peut etre primitif ou secondaire a des connectivites, le plus souvent au lupus erythemateux dissemine, a des pathologies infectieuses ou neoplasiques [3]. Les anticoagulants circulants sont le plus souvent recherches face a un allongement anormal de certains test de l'hemostase in vitro. Les anticardiolipides sont un groupe heterogene d'anticorps. Ils reconnaissent des epitopes constitues par la region anionique des phospholipides et/ou leur cofacteur proteique, tel que la beta2-glycoproteine I (apolipoproteine H), la prothrombine, ou les proteines S et C [2]. La presence de ces anticorps peut avoir des implications pathologiques, car un titre eleve d'anticardiolipides anti-beta2-glycoproteine I d'isotype G est en effet correle a une forte incidence de thromboses arterielles ou veineuses [4]. Nous rapportons ici une observation de syndrome primitif des anticardiolipides, compliquee d'une necrose hemorragique bilaterale des surrenales, atteinte peu decrite dans la litterature [1, 2, 5, 6].
Dealing daily with various machines and various control specimens provides a lot of data that cannot be processed manually. In order to help decision-making we wrote specific software coping with the traditional QC, with patient data (mean of normals, delta check) and with criteria related to the analytical equipment (flags and alarms). Four machines (3 Ektachem 700 and 1 Hitachi 911) analysing 25 common chemical tests are controlled. Every day, three different control specimens and one more once a week (regional survey) are run on the various pieces of equipment. The data are collected on a 486 microcomputer connected to the central computer. For every parameter the standard deviation is compared with the published acceptable limits and the Westgard's rules are computed. The mean of normals is continuously monitored. The final decision induces either an alarm sound and the print-out of the cause of rejection or, if no alarms happen, the daily print-out of recorded data, with or without the Levey Jennings graphs.
In Europe, the KC 10, manufactured by Amelung Germany, is one of the instruments most commonly found in coagulation laboratories. For facilitating the work of technical validation, we wrote a software adapted to any IBM or compatible PC running under MS-DOS, to manage the analyser performance. Data are automatically collected via the BCD interface from the analyser or keyed in for the other techniques. The software deals with 64 different analyses entirely 'user defined'. An 'electronic worksheet' presents the results, by page of ten patients. This enables the laboratory technician to assess the coherence of the various data and to perform verifications or complementary tests if necessary. As an option, a blinking asterisk can signal all results outside predetermined range. By moving the cursor through the table, a test result can be deleted, modified or added. A function displays the patient's previous files in a window because the data are recorded in long-term archives at the end of the day. This long-term recording allows a search of previous files to decide additional tests if the patient is unknown. A daily archive function classifies and prints the whole day's work in alphabetical order. A protocol of communication allows connection to a mainframe Bayer-Technicon computer. This program and the user's manual are free, available on request from address above.
The Electra 800 automatic coagulation analyser rapidly performs most chronometric coagulation tests with high precision. To facilitate data handling, software, adaptable to any PC running under MS-DOS(R), was written to manage the analyser. Data are automatically collected via the RS232 interface or can be manually input. The software can handle 64 different analyses, all entirely 'user defined'. An 'electronic worksheet' presents the results in pages of ten patients. This enables the operator to assess the data and to perform verifications or complementary tests if necessary. All results outside a predetermined range can be flagged and results can be deleted, modified or added. A patient's previous files can be recalled as the data are archived at the end of the day. A 120 Mb disk can store approximately 130000 patient files. A daily archive function can print the day's work in alphabetical order. A communication protocol allows connection to a mainframe computer. This program and the user's manual are available on request, free of charge, from the authors.
Results of prospective studies indicate that increased fibrinogen concentration is significantly associated with the risk of arteriosclerotic vessel disease. As the fibrinogen concentration is considered to rise with aging, determination of its physiological values with various methods in strictly healthy adult and aged individuals is a prerequisite to evaluating the relative contribution of fibrinogen to cardiovascular diseases. Fibrinogen concentration was determined in 209 healthy subjects, aged 19 to 96 years. Persons over the age of 60 were recruited according to the stringent criteria of the Senieur protocol established for human immunogerontological studies. Fibrinogen concentrations, obtained by heating precipitation and by thrombin clotting time with both electromagnetic water-bath and semiautomatic coagulometer, ranged from 1.55 to 3.70 g/L. A rise in plasma concentration was observed with aging. Independently of age, females exhibited higher concentrations than males. Significantly higher values were observed in subjects over 60 years of age, in both sexes, in comparison with the younger groups.
The Electra 800 automatic analyzer performs at high speed and with great precision almost all chronometric coagulation tests. However, the results have to be recopied by hand and if necessary converted using standard graphs if the machine does not have the Data Management option. We therefore developed a data management program for this analyzer, for use with a PC or AT (IBM®) compatible microcomputer.