Objective.The advantage of apertures sharpening the edges of pencil beam scanning proton fields comes with the price of an increased out-of-field dose predominantly mediated by secondary neutrons. The objective of this study was to measure the increase in neutron ambient dose equivalent () for monoenergetic proton fields collimated by static brass apertures compared to non-collimated fields. The influence of the aperture material, i.e. brass and nickel, on the neutron contamination was investigated. The experimental results were compared with a Monte Carlo (MC) simulation framework.Approach.Experiments were conducted in a treatment room of a proton therapy center. Thewas measured with three extended-range rem-meters at multiple out-of-field positions at 2 m/1.12 m distance from the isocenter for quasi-monochromatic square proton fields (100, 140, 180 MeV) incident on a 30solid water target. The measurement results were compared to respective calculations with the TOPAS MC simulation framework.Main results.Collimating the edges of 10fields with apertures increased theon average by 23%. This increase was up to 74% in lateral direction to the beam and up to 6% in forward direction. With a reduction ofdown to 50% and 33% on average, nickel proved to be more favorable than brass. Placing a range-shifter upstream of the aperture is more favorable compared to the downstream placement since thewas on average 20% lower. Considering the associated uncertainties, the simulations and experiments agreed well with an average absolute deviation of 11.7% (1% to 34%).Significance.Concluding, the increase ofcaused by apertures sharpening scanned proton field edges is small to moderate with 23% on average. Neutron contamination can be reduced by material selection and the arrangement of beam-shaping devices. TOPAS is suited for the application under consideration.
Gunshot deaths due to homicide or military encounters are a major health concern. Noninvasive bullet characterization is of major importance for patients with lodged bullets or in mass disasters with multiple cadavers, which must be prioritized for autopsy. Therefore, the aim of this study was to investigate whether brass and lead bullets can be differentiated using photon-counting CT (PCCT). Nine different lead (n = 6) or brass (n = 3) bullets were investigated on a state-of-the-art PCCT using a clinically unavailable research mode. Here, four image sets were reconstructed for different energy thresholds (20, 55, 72, 90 keV). Three circular regions of interest were placed on the 20-keV threshold images by two readers and automatically copied to the three other threshold images. Based on measured HU mean and max values, dual-energy indices (DEI) were calculated for the low/high energy threshold pairs of 20/90, 55/90, and 72/90 keV. Significant differences of DEIs between lead and brass projectiles were observed for the 20/90 keV DEI for HU mean ± standard deviation values (Qr40 kernel, lead: -0.085 ± 0.021, brass: 0.024 ± 0.048) and HU max values (Qr40 kernel, lead: -0.093 ± 0.011, brass: 0.023 ± 0.057) (p < 0.001 for both). Differences decreased for the 55/90 and 72/90 keV DEIs between the two projectile materials but remained statistically significant. In this PCCT phantom study, significant differences were observed between lead and brass bullets in the different energy threshold images. Photon-counting CT could be a promising tool for bullet identification as significant differences were found in the different energy threshold images for lead and brass bullets, with application in clinical and forensic radiology.
PURPOSE:To investigate the relationship between the stereographic and azimuthal equidistant projection (AEP) of the human retina for radiotherapy planning with OPTOS optomap wide-field fundus images (Optos, UK). Further, the geometric accuracy of an OPTOS fundus image is quantified. METHODS:The fundamental relationship between both projection modes was applied to transform images acquired with an OPTOS Silverstone camera to the azimuthal equidistant projection using MATLAB. Fundus images of four patients were used to quantitatively demonstrate the impact for neglecting the proper projection. For that purpose, a delineated contour for each patient was analyzed if created in a treatment planning system, which assumes AEP, and compared with an OPTOS image. Furthermore, an eye model with a novel 3D printed retina pattern was used to quantify the geometric accuracy for an OPTOS optomap image. RESULTS:The difference between both projections was found substantial, leading to a change in delineated contours of more than 5 mm in the investigated cases and a change of delineated area of more than 40%. The geometric accuracy of OPTOS images of a customized eye model was found to be 0.2 mm on average, increasing to at most ∼0.5 mm at eye angles of 81°. CONCLUSION:The fundamental difference in the representation of the eye fundus needs to be accounted for in radiotherapy planning of uveal melanoma. The basic underlying relationship for transformation is known, but more research is required to quantify other aberrations. The novel use of 3D printed retina patterns with known dimensions is providing a flexible approach for further investigations.
Proton therapy (PT) is an advancing radiotherapy modality increasingly integrated into clinical settings, transitioning from research facilities to hospital environments. A critical aspect of the commissioning of a proton pencil beam scanning delivery system is the acquisition of experimental beam data for accurate beam modelling within the treatment planning system (TPS). These guidelines describe in detail the acquisition of proton pencil beam modelling data. First, it outlines the intrinsic characteristics of a proton pencil beam—energy distribution, angular-spatial distribution and particle number. Then, it lists the input data typically requested by TPSs. Finally, it describes in detail the set of experimental measurements recommended for the acquisition of proton pencil beam modelling data—integrated depth-dose curves, spot maps in air, and reference dosimetry. The rigorous characterization of these beam parameters is essential for ensuring the safe and precise delivery of proton therapy treatments.
BACKGROUND:Quality assurance (QA) on a daily basis is an essential task in radiotherapy. In pencil beam scanning proton therapy (PBS), there is a lack of available practical QA devices for routine daily QA in comparison to conventional radiotherapy. PURPOSE:The aim was to characterize and evaluate a prototype for the task of daily QA routine for PBS with parameters recommended by the AAPM TG 224, that is, the dose output constancy, the spot position and the distal range verification. Furthermore, a time efficient calibration method for fast and reliable daily QA routine was established for the prototype. METHODS:First, a calibration routine was designed and evaluated, which characterizes the array response and allows for a conversion of the measured signal to clinically needed QA parameters. Finally, a time and resource efficient daily QA routine was developed and tested. RESULTS:The prototype array can distinguish spot position deviations with sub-millimeter accuracy, as well as changes in the spot size in terms of FWHM with a 2 % $\%$ sensitivity. The range and thus the energy can be evaluated at different depths also with sub-millimeter precision. After some training, the setup of the prototype device took roughly two minutes and the total beamtime was about one minute on cyclotron site and five minutes for synchrotrons. CONCLUSIONS:A prototype for daily QA in spot scanning proton therapy was evaluated, which features a fast and easy setup and allows for measuring relevant beam parameters, typically within less than a minute of beam time. All QA parameters as recommended by the AAPM TG 224 report can be analyzed with sufficient accuracy.
Background and purpose To establish an international quality standard for contouring and planning for high-risk neuroblastoma within the prospective High-Risk Neuroblastoma Study 2 of SIOP-Europe-Neuroblastoma (SIOPEN HR-NBL2), which includes a randomized question on dose escalation for residual disease. Materials and methods Data on four patients with high-risk neuroblastoma were selected and distributed to the radiotherapy committee of the HR-NBL2 study for independent contouring and planning. Differences in contouring were analyzed using apparent and kappa-corrected agreement. Plans were analyzed regarding the dose-volume histogram metrics. Results were discussed among experts and agreement was obtained. Results Substantial agreement was found for contouring of the heart (0.64), liver (0.70), left lung (0.74), and right lung (0.74). For contouring of the gastrointestinal tract (0.54), left kidney (0.60), and right kidney (0.59) moderate agreement was obtained. For target volume delineation, agreement for preoperative tumour extent was moderate (0.42), for CTV fair (0.35) and only low (0.06) for residual tumour, respectively. The dose planning strategies appeared to be relatively homogeneous among all experts. Conclusion Considerable variability was found for the delineation of target volumes, particularly the boost volume, whereas the contouring of the organs at risk and the planning strategy were reasonably consistent. In order to obtain reliable results from the randomized HR-NBL2 trial, standardization of target volume delineation based on adequate imaging is crucial.
Background: The aim of this study is to examine the dosimetric influence of endorectal balloons (ERB) on rectal sparing in prostate cancer patients with implanted hydrogel rectum spacers treated with dose-escalated or hypofractionated intensity-modulated proton beam therapy (IMPT). Methods: Ten patients with localized prostate cancer included in the ProRegPros study and treated at our center were investigated. All patients underwent placement of hydrogel rectum spacers before planning. Two planning CTs (with and without 120 cm3 fluid-filled ERB) were applied for each patient. Dose prescription was set according to the h strategy, with 72 Gray (Gy)/2.4 Gy/5× weekly to prostate + 1 cm of the seminal vesicle, and 60 Gy/2 Gy/5× weekly to prostate + 2 cm of the seminal vesicle. Planning with two laterally opposed IMPT beams was performed in both CTs. Rectal dosimetry values including dose-volume statistics and normal tissue complication probability (NTCP) were compared for both plans (non-ERB plans vs. ERB plans). Results: For ERB plans compared with non-ERB, the reductions were 8.51 ± 5.25 Gy (RBE) (p = 0.000) and 15.76 ± 11.11 Gy (p = 0.001) for the mean and the median rectal doses, respectively. No significant reductions in rectal volumes were found after high dose levels. The use of ERB resulted in significant reduction in rectal volume after receiving 50 Gy (RBE), 40 Gy (RBE), 30 Gy (RBE), 20 Gy (RBE), and 10 Gy (RBE) with p values of 0.034, 0.008, 0.003, 0.001, and 0.001, respectively. No differences between ERB and non-ERB plans for the anterior rectum were observed. ERB reduced posterior rectal volumes in patients who received 30 Gy (RBE), 20 Gy (RBE), or 10 Gy (RBE), with p values of 0.019, 0.003, and 0.001, respectively. According to the NTCP models, no significant reductions were observed in mean or median rectal toxicity (late rectal bleeding ≥ 2, necrosis or stenosis, and late rectal toxicity ≥ 3) when using the ERB. Conclusion: ERB reduced rectal volumes exposed to intermediate or low dose levels. However, no significant reduction in rectal volume was observed in patients receiving high or intermediate doses. There was no benefit and also no disadvantage associated with the use of ERB for late rectal toxicity, according to available NTCP models.
BACKGROUND:A Faraday cup (FC) facilitates a quite clean measurement of the proton fluence emerging from clinical spot-scanning nozzles with narrow pencil-beams. The utilization of FCs appears to be an attractive option for high dose rate delivery modes and the source models of Monte-Carlo (MC) dose engines. However, previous studies revealed discrepancies of 3%-6% between reference dosimetry with ionization chambers (ICs) and FC-based dosimetry. This has prevented the widespread use of FCs for dosimetry in proton therapy. PURPOSE:The current study aims at bridging the gap between FC dosimetry and IC dosimetry of proton fields delivered with spot-scanning treatment heads. Particularly, a novel method to evaluate FC measurements is introduced. METHODS:A consistency check is formulated, which makes use of the energy balance and the reciprocity theorem. The measurement data comprise central-axis depth distributions of the absorbed dose of quasi-monochromatic fields with a width of about 28.5 cm and FC measurements of the reciprocal fields with a single spot. These data are complemented by a look-up of energy-range tables, the average Q-value of transmutations, and the escape energy carried away by neutrons and photons. The latter data are computed by MC simulations, which in turn are validated with measurements of the distal dose tail and neutron out-of-field doses. For comparison, the conventional approach of FC evaluation is performed, which computes absorbed dose from the product of fluence and stopping power. The results from the FC measurements are compared with the standard dosimetry protocols and improved reference dosimetry methods. RESULTS:The deviation between the conventional FC-based dosimetry and the IC-based one according to standard dosimetry protocols was -4.7 ( ± $\pm$ 3.3)% for a 100 MeV field and -3.6 ( ± $\pm$ 3.5)% for 200 MeV, thereby agreeing within the reported uncertainties. The deviations could be reduced to -4.0 ( ± $\pm$ 2.9)% and -3.0 ( ± $\pm$ 3.1)% by adopting state-of-the-art reference dosimetry methods. The alternative approach using the energy balance gave deviations of only -1.9% (100 MeV) and -2.6% (200 MeV) using state-of-the-art dosimetry. The standard uncertainty of this novel approach was estimated to be about 2%. CONCLUSIONS:An alternative concept has been established to determine the absorbed dose of monoenergetic proton fields with an FC. It eliminates the strong dependence of the conventional FC-based approach on the MC simulation of the stopping-power and of the secondary ions, which according to the study at hand is the major contributor to the underestimation of the absorbed dose. Some contributions to the uncertainty of the novel approach could potentially be reduced in future studies. This would allow for accurate consistency tests of conventional dosimetry procedures.
Purpose: The primary fluence of a proton pencil beam exiting the accelerator is enveloped by a region of secondaries, commonly called "spray". Although small in magnitude, this spray may affect dose distributions in pencil beam scanning mode e.g., in the calculation of the small field output, if not modelled properly in a treatment planning system (TPS). The purpose of this study was to dosimetrically benchmark the Monte Carlo (MC) dose engine of the RayStation TPS (v.10A) in small proton fields and systematically compare single Gaussian (SG) and double Gaussian (DG) modeling of initial proton fluence providing a more accurate representation of the nozzle spray.Methods: The initial proton fluence distribution for SG/DG beam modeling was deduced from two-dimensional measurements in air with a scintillation screen with electronic readout. The DG model was either based on direct fits of the two Gaussians to the measured profiles, or by an iterative optimization procedure, which uses the measured profiles to mimic in-air scan-field factor (SF) measurements. To validate the DG beam models SFs, i.e. relative doses to a 10 x 10 cm(2) field, were measured in water for three different initial proton energies (100MeV, 160MeV, 226.7MeV) and square field sizes from 1x1cm(2) to 10x10cm(2) using a small field ionization chamber (IBA CC01) and an IBA ProteusPlus system (universal nozzle). Furthermore, the dose to the center of spherical target volumes (diameters: 1cm to 10cm) was determined using the same small volume ionization chamber (IC). A comprehensive uncertainty analysis was performed, including estimates of influence factors typical for small field dosimetry deduced from a simple two-dimensional analytical model of the relative fluence distribution. Measurements were compared to the predictions of the RayStation TPS.Results: SFs deviated by more than 2% from TPS predictions in all fields <4x4cm(2) with a maximum deviation of 5.8% for SG modeling. In contrast, deviations were smaller than 2% for all field-sizes and proton energies when using the directly fitted DG model. The optimized DG model performed similarly except for slightly larger deviations in the 1x1cm(2) scan-fields. The uncertainty estimates showed a significant impact of pencil beam size variations (+/- 5%) resulting in up to 5.0% standard uncertainty. The point doses within spherical irradiation volumes deviated from calculations by up to 3.3% for the SG model and 2.0% for the DG model.Conclusion: Properly representing nozzle spray in RayStation's MC-based dose engine using a DG beam model was found to reduce the deviation to measurements in small spherical targets to below 2%. A thorough uncertainty analysis shows a similar magnitude for the combined standard uncertainty of such measurements.
Background and purposeAs a part of the commissioning and quality assurance in proton beam therapy, lateral dose profiles and output factors have to be acquired. Such measurements can be performed with point detectors and are especially challenging in small fields or steep lateral penumbra regions as the detector's volume effect may lead to perturbations. To address this issue, this work aims to quantify and correct for such perturbations of six point detectors in small proton fields created via three different delivery techniques. MethodsLateral dose profile and output measurements of three proton beam delivery techniques (pencil beam scanning, pencil beam scanning combined with collimators, passive scattering with collimators) were performed using high-resolution EBT3 films, a PinPoint 3D 31022 ionization chamber, a microSilicon diode 60023 and a microDiamond detector 60019 (all PTW Freiburg, Germany). Detector specific lateral dose response functions K(x,y) acting as the convolution kernel transforming the undisturbed dose distribution D(x,y) into the measured signal profiles M(x,y) were applied to quantify perturbations of the six investigated detectors in the proton fields and correct the measurements. A signal theoretical analysis in Fourier space of the dose distributions and detector's K(x,y) was performed to aid the understanding of the measurement process with regard to the combination of detector choice and delivery technique. ResultsQuantification of the lateral penumbra broadening and signal reduction at the fields center revealed that measurements in the pencil beam scanning fields are only compromised slightly even by large volume ionization chambers with maximum differences in the lateral penumbra of 0.25 mm and 4% signal reduction at the field center. In contrast, radiation techniques with collimation are not accurately represented by the investigated detectors as indicated by a penumbra broadening up to 1.6 mm for passive scattering with collimators and 2.2 mm for pencil beam scanning with collimators. For a 3 mm diameter collimator field, a signal reduction at field center between 7.6% and 60.7% was asserted. Lateral dose profile measurements have been corrected via deconvolution with the corresponding K(x,y) to obtain the undisturbed D(x,y). Corrected output ratios of the passively scattered collimated fields obtained for the microDiamond, microSilicon and PinPoint 3D show agreement better than 0.9% (one standard deviation) for the smallest field size of 3 mm. ConclusionPoint detector perturbations in small proton fields created with three delivery techniques were quantified and found to be especially pronounced for collimated small proton fields with steep dose gradients. Among all investigated detectors, the microSilicon diode showed the smallest perturbations. The correction strategies based on detector's K(x,y) were found suitable for obtaining unperturbed lateral dose profiles and output factors. Approximation of K(x,y) by considering only the geometrical averaging effect has been shown to provide reasonable prediction of the detector's volume effect. The findings of this work may be used to guide the choice of point detectors in various proton fields and to contribute toward the development of a code of practice for small field proton dosimetry.