Patients undergoing radiation therapy experience debilitating side effects because of toxicity arising from radiation-induced DNA strand breaks in normal peritumoural cells. Here, inspired by the ability of tardigrades to resist extreme radiation through the expression of a damage-suppressor protein that binds to DNA and reduces strand breaks, we show that the local and transient expression of the protein can reduce radiation-induced DNA damage in oral and rectal epithelial tissues (which are commonly affected during radiotherapy for head-and-neck and prostate cancers, respectively). We used ionizable lipid nanoparticles supplemented with biodegradable cationic polymers to enhance the transfection efficiency and delivery of messenger RNA encoding the damage-suppressor protein into buccal and rectal tissues. In mice with orthotopic oral cancer, messenger RNA-based radioprotection of normal tissue preserved the efficacy of radiation therapy. The strategy may be broadly applicable to the protection of healthy tissue from DNA-damaging agents.
Triggerable coatings, such as pH-responsive polymethacrylate copolymers, can be used to protect the active pharmaceutical ingredients contained within oral solid dosage forms from the acidic gastric environment and to facilitate drug delivery directly to the intestine. However, gastrointestinal pH can be highly variable, which can reduce delivery efficiency when using pH-responsive drug delivery technologies. We hypothesized that biomaterials susceptible to proteolysis could be used in combination with other triggerable polymers to develop novel enteric coatings. Bioinformatic analysis suggested that silk fibroin is selectively degradable by enzymes in the small intestine, including chymotrypsin, but resilient to gastric pepsin. Based on the analysis, we developed a silk fibroin-polymethacrylate copolymer coating for oral dosage forms. In vitro and in vivo studies demonstrated that capsules coated with this novel silk fibroin formulation enable pancreatin-dependent drug release. We believe that this novel formulation and extensions thereof have the potential to produce more effective and personalized oral drug delivery systems for vulnerable populations including patients that have impaired and highly variable intestinal physiology.
Wound closure is critical for the care of wounds by preventing foreign matter entry and supporting healing. Failure of wound closure because of mechanical compromise or inflammation can lead to failure of effective apposition of tissues and manifest in delayed healing and even death, depending on the site of the wound. Therefore, a platform capable of identifying inflammation as well as delivery of therapeutics, including chemical, biological, and cellular therapies, could transform our capacity to effectively sense potential failure as well as maximize healing. Here, we report the development of a decellularized gut suture platform capable of sensing inflammation as well as delivering a broad array of therapeutics, including small molecules, monoclonal antibodies, and cell-based therapeutics. We demonstrate the mechanical and biological functionalities of our platform in rodents and pigs. We anticipate that this platform could transform how we care for wounds and anastomoses of patients.
Patient adherence to chronic therapies can be suboptimal, leading to poor therapeutic outcomes. Dosage forms that enable reduction in dosing frequency stand to improve patient adherence. Variation in gastrointestinal transit time, inter-individual differences in gastrointestinal physiology and differences in physicochemical properties of drugs represent challenges to the development of such systems. To this end, a small intestine-targeted drug delivery system is developed, where prolonged gastrointestinal retention and sustained release are achieved through tissue adhesion of drug pills mediated by an essential intestinal enzyme catalase. Here proof-of-concept pharmacokinetics is demonstrated in the swine model for two drugs, hydrophilic amoxicillin and hydrophobic levodopa. It is anticipated that this system can be applicable for many drugs with a diverse of physicochemical characteristics.
Nucleic acids are enabling a new generation of therapeutics and vaccines to treat and prevent a range of diseases. While these therapies have typically been limited to parenteral dosing, patients and clinicians prefer oral dosage forms. Furthermore, oral delivery enables local transfection of cells in the gastrointestinal tract not easily targeted via parenteral administration. To address these challenges, we synthesized and screened a library of branched hybrid poly(beta-a-mino ester) mRNA nanoparticles for transfection efficiency; then we combined the highest performing formulations with ingestible milli injector capsules capable of delivering formulations directly into gastric tissue. We validated the performance of formulations and devices in rodents and pigs, demonstrating protein translation in the delta, gastric, and parietal cells of the gastric mucosa, in addition to systemic uptake. We anticipate oral delivery of mRNA could facilitate rapid deployment of episodic interventions, such as vaccines, and support long-term therapies.
Intravesical instillation is an efficient drug delivery route for the local treatment of various urological conditions. Nevertheless, intravesical instillation is associated with several challenges, including pain, urological infection, and frequent clinic visits for catheterization; these difficulties support the need for a simple and easy intravesical drug delivery platform. Here, we propose a novel biodegradable intravesical device capable of long-term, local drug delivery without a retrieval procedure. The intravesical device is composed of drug encapsulating biodegradable polycaprolactone (PCL) microcapsules and connected by a bioabsorbable Polydioxanone (PDS) suture with NdFeB magnets in the end. The device is easily inserted into the bladder and forms a 'ring' shape optimized for maximal mechanical stability as informed by finite element analysis. In this study, inserted devices were retained in a swine model for 4 weeks. Using this device, we evaluated the system's capacity for delivery of lidocaine and resiquimod and demonstrated prolonged drug release. Moreover, a cost-effectiveness analysis supports device implementation compared to the standard of care. Our data support that this device can be a versatile drug delivery platform for urologic medications.
Glycemic control through titration of insulin dosing remains the mainstay of diabetes mellitus treatment. Insulin therapy is generally divided into dosing with long -and short-acting insulin, where long-acting insulin provides basal coverage and short-acting insulin supports glycemic excursions associated with eating. The dosing of short-acting insulin often involves several steps for the user including blood glucose measurement and integration of potential carbohydrate loads to inform safe and appropriate dosing. The significant burden placed on the user for blood glucose measurement and effective carbohydrate counting can manifest in substantial effects on adherence. Through the application of computer vision, we have developed a smartphone-based system that is able to detect the carbohydrate load of food by simply taking a single image of the food and converting that information into a required insulin dose by incorporating a blood glucose measurement. Moreover, we report the development of comprehensive all-in-one insulin delivery systems that streamline all operations that peripheral devices require for safe insulin administration, which in turn significantly reduces the complexity and time required for titration of insulin. The development of an autonomous system that supports maximum ease and accuracy of insulin dosing will transform our ability to more effectively support patients with diabetes.
Maintaining an ample supply of personal protective equipment continues to be a challenge for the healthcare industry, especially during emergency situations and times of strain on the supply chain. Most critically, healthcare workers exposed to potential airborne hazards require sufficient respiratory protection. Respirators are the only type of personal protective equipment able to provide adequate respiratory protection. However, their ability to shield hazards depends on design, material, proper fit, and environmental conditions. As a result, not all respirators may be adequate for all scenarios. Additionally, factors including user comfort, ease of use, and cost contribute to respirator effectiveness. Therefore, a careful consideration of these parameters is essential for ensuring respiratory protection for those working in the healthcare industry. Here respirator design and material characteristics are reviewed, as well as properties of airborne hazards and potential filtration mechanisms, regulatory standards of governmental agencies, respirator efficacy in the clinical setting, attitude of healthcare personnel toward respiratory protection, and environmental and economic considerations of respirator manufacturing and distribution.
Administering medicines to 0- to 5-year-old children in a resource-limited environment requires dosage forms that circumvent swallowing solids, avoid on-field reconstitution, and are thermostable, cheap, versatile, and taste masking. We present a strategy that stands to solve this multifaceted problem. As many drugs lack adequate water solubility, our formulations used oils, whose textures could be modified with gelling agents to form “oleogels.” In a clinical study, we showed that the oleogels can be formulated to be as fluid as thickened beverages and as stiff as yogurt puddings. In swine, oleogels could deliver four drugs ranging three orders of magnitude in their water solubilities and two orders of magnitude in their partition coefficients. Oleogels could be stabilized at 40°C for prolonged durations and used without redispersion. Last, we developed a macrofluidic system enabling fixed and metered dosing. We anticipate that this platform could be adopted for pediatric dosing, palliative care, and gastrointestinal disease applications.
Drug metabolism leads to biotransformations of pharmaceutical substances that alter drug efficacy, toxicity, as well as drug interactions. Modeling these processes ex vivo stands to greatly accelerate our capacity to develop safe and efficacious drugs and formulations. Recognizing the liver as the primary site of drug metabolism, here we report a novel whole-tissue ex vivo liver screening platform that enabled modeling of hepatic metabolism and tracking of hepatotoxic drug metabolites. We applied the system for the characterization of acetaminophen (APAP) metabolism and identified interactions that can mitigate the generation of toxic metabolites ex vivo . Combining our experimental platform with state-of-the-art machine learning, we validated two novel functional excipients that can prevent APAP hepatotoxicity in vivo in mice. To assess translational potential, we prototyped a novel solid dosage form with controlled release of both APAP and our functional excipients. Our this platform provides innovative potential access to actionable data on drug metabolism to support the development of new therapeutic approaches.
Implantable drug depots have the capacity to locally meet therapeutic requirements by maximizing local drug efficacy and minimizing potential systemic side effects. Tubular organs including the gastrointestinal tract, respiratory tract and vasculature all manifest with endoluminal disease. The anatomic distribution of localized drug delivery for these organs using existing therapeutic modalities is limited. Application of local depots in a circumferential and extended longitudinal fashion could transform our capacity to offer effective treatment across a range of conditions. Here we report the development and application of a kirigami-based stent platform to achieve this. The stents comprise a stretchable snake-skin-inspired kirigami shell integrated with a fluidically driven linear soft actuator. They have the capacity to deposit drug depots circumferentially and longitudinally in the tubular mucosa of the gastrointestinal tract across millimetre to multi-centimetre length scales, as well as in the vasculature and large airways. We characterize the mechanics of kirigami stents for injection, and their capacity to engage tissue in a controlled manner and deposit degradable microparticles loaded with therapeutics by evaluating these systems ex vivo and in vivo in swine. We anticipate such systems could be applied for a range of endoluminal diseases by simplifying dosing regimens while maximizing drug on-target effects through the sustained release of therapeutics and minimizing systemic side effects. A kirigami-inspired stent-based system has been developed for extended local drug delivery to the gastrointestinal and respiratory tracts as well as the vascular system.
Alternative means for drug delivery are needed to facilitate drug adherence and administration. Microneedles (MNs) have been previously investigated transdermally for drug delivery. To date, drug loading into MNs has been limited by drug solubility in the polymeric blend. We designed a highly drug-loaded MN patch to deliver macromolecules and applied it to the buccal area, which allows for faster delivery than the skin. We successfully delivered 1-mg payloads of human insulin and human growth hormone to the buccal cavity of swine within 30 s. In addition, we conducted a trial in 100 healthy volunteers to assess potential discomfort associated with MNs when applied in the oral cavity, identifying the hard palate as the preferred application site. We envisage that MN patches applied on buccal surfaces could increase medication adherence and facilitate the painless delivery of biologics and other drugs to many, especially for the pediatric and elderly populations.
Importance:Adoption of mask wearing in response to the COVID-19 pandemic alters daily communication.Objective:To assess communication barriers associated with mask wearing in patient-clinician interactions and individuals who are deaf and hard of hearing.Design, Setting, and Participants:This pilot cross-sectional survey study included the general population, health care workers, and health care workers who are deaf or hard of hearing in the United States. Volunteers were sampled via an opt-in survey panel and nonrandomized convenience sampling. The general population survey was conducted between January 5 and January 8, 2021. The health care worker surveys were conducted between December 3, 2020, and January 3, 2021. Respondents viewed 2 short videos of a study author wearing both a standard and transparent N95 mask and answered questions regarding mask use, communication, preference, and fit. Surveys took 15 to 20 minutes to complete.Main Outcomes and Measures:Participants' perceptions were assessed surrounding the use of both mask types related to communication and the ability to express emotions.Results:The national survey consisted of 1000 participants (mean [SD] age, 48.7 [18.5] years; 496 [49.6%] women) with a response rate of 92.25%. The survey of general health care workers consisted of 123 participants (mean [SD] age, 49.5 [9.0] years; 84 [68.3%] women), with a response rate of 11.14%. The survey of health care workers who are deaf or hard of hearing consisted of 45 participants (mean [SD] age, 54.5 [9.0] years; 30 [66.7%] women) with a response rate of 23.95%. After viewing a video demonstrating a study author wearing a transparent N95 mask, 781 (78.1%) in the general population, 109 general health care workers (88.6%), and 38 health care workers who are deaf or hard of hearing (84.4%) were able to identify the emotion being expressed, in contrast with 201 (20.1%), 25 (20.5%), and 11 (24.4%) for the standard opaque N95 mask. In the general population, 450 (45.0%) felt positively about interacting with a health care worker wearing a transparent mask; 76 general health care workers (61.8%) and 37 health care workers who are deaf or hard of hearing (82.2%) felt positively about wearing a transparent mask to communicate with patients.Conclusions and Relevance:The findings of this study suggest that transparent masks could help improve communication during the COVID-19 pandemic, particularly for individuals who are deaf and hard of hearing.
IMPORTANCE Before the widespread implementation of robotic systems to provide patient care during the COVID-19 pandemic occurs, it is important to understand the acceptability of these systems among patients and the economic consequences associated with the adoption of robotics in health care settings. OBJECTIVE To assess the acceptability and feasibility of using a mobile robotic system to facilitate health care tasks. DESIGN, SETTING, AND PARTICIPANTS This study included 2 components: a national survey to examine the acceptability of using robotic systems to perform health care tasks in a hospital setting and a single-site cohort study of patient experiences and satisfaction with the use of a mobile robotic system to facilitate triage and telehealth tasks in the emergency department (ED). The national survey comprised individuals living in the US who participated in a sampling-based survey via an online analytic platform. Participants completed the national survey between August 18 and August 21, 2020. The single-site cohort study included patients living in the US who presented to the ED of a large urban academic hospital providing quaternary care in Boston, Massachusetts between April and August 2020. All data were analyzed from August to October 2020. EXPOSURES Participants in the national survey completed an online survey to measure the acceptability of using a mobile robotic system to perform health care tasks (facilitating telehealth interviews, acquiring vital signs, obtaining nasal or oral swabs, placing an intravenous catheter, performing phlebotomy, and turning a patient in bed) in a hospital setting in the contexts of general interaction and interaction during the COVID-19 pandemic. Patients in the cohort study were exposed to a mobile robotic system, which was controlled by an ED clinician and used to facilitate a triage interview. After exposure, patients completed an assessment to measure their satisfaction with the robotic system. MAIN OUTCOMES AND MEASURES Acceptability of the use of a mobile robotic system to facilitate health care tasks in a hospital setting (national survey) and feasibility and patient satisfaction regarding the use of a mobile robotic system in the ED (cohort study). RESULTS For the national survey, 1154 participants completed all acceptability questions, representing a participation rate of 35%. After sample matching, a nationally representative sample of 1000 participants (mean [SD] age, 48.7 [17.0] years; 535 women [53.5%]) was included in the analysis. With regard to the usefulness of a robotic system to perform specific health care tasks, the response of "somewhat useful" was selected by 373 participants (37.3%) for facilitating telehealth interviews, 350 participants (35.0%) for acquiring vital signs, 307 participants (30.7%) for obtaining nasal or oral swabs, 228 participants (22.8%) for placing an intravenous catheter, 249 participants (24.9%) for performing phlebotomy, and 371 participants (37.1%) for turning a patient in bed. The response of "extremely useful" was selected by 287 participants (28.7%) for facilitating telehealth interviews, 413 participants (41.3%) for acquiring vital signs, 192 participants (19.2%) for obtaining nasal or oral swabs, 159 participants (15.9%) for placing an intravenous catheter, 167 participants (16.7%) for performing phlebotomy, and 371 participants (37.1%) for turning a patient in bed. In the context of the COVID-19 pandemic, the median number of individuals who perceived the application of robotic systems to be acceptable for completing telehealth interviews, obtaining nasal and oral swabs, placing an intravenous catheter, and performing phlebotomy increased. For the ED cohort study, 51 individuals were invited to participate, and 41 participants (80.4%) enrolled. One participant was unable to complete the study procedures because of a signaling malfunction in the robotic system. Forty patients (mean [SD] age, 45.8 [2.7] years; 29 women [72.5%]) completed the mobile robotic system-facilitated triage interview, and 37 patients (92.5%) reported that the interaction was satisfactory. A total of 33 participants (82.5%) reported that their experience of receiving an interview facilitated by a mobile robotic system was as satisfactory as receiving an in-person interview from a clinician. CONCLUSIONS AND RELEVANCE In this study, a mobile robotic system was perceived to be acceptable for use in a broad set of health care tasks among survey respondents across the US. The use of a mobile robotic system enabled the facilitation of contactless triage interviews of patients in the ED and was considered acceptable among participants. Most patients in the ED rated the quality of mobile robotic system-facilitated interaction to be equivalent to in-person interaction with a clinician.
Continuous monitoring in the intensive care setting has transformed the capacity to rapidly respond with interventions for patients in extremis. Noninvasive monitoring has generally been limited to transdermal or intravascular systems coupled to transducers including oxygen saturation or pressure. Here it is hypothesized that gastric fluid (GF) and gases, accessible through nasogastric (NG) tubes, commonly found in intensive care settings, can provide continuous access to a broad range of biomarkers. A broad characterization of biomarkers in swine GF coupled to time-matched serum is conducted . The relationship and kinetics of GF-derived analyte level dynamics is established by correlating these to serum levels in an acute renal failure and an inducible stress model performed in swine. The ability to monitor ketone levels and an inhaled anaesthetic agent (isoflurane) in vivo is demonstrated with novel NG-compatible sensor systems in swine. Gastric access remains a main stay in the care of the critically ill patient, and here the potential is established to harness this establishes route for analyte evaluation for clinical management.
Cancer patients undergoing therapeutic radiation routinely develop injury of the adjacent gastrointestinal (GI) tract mucosa due to treatment. To reduce radiation dose to critical GI structures including the rectum and oral mucosa, 3D-printed GI radioprotective devices composed of high-Z materials are generated from patient CT scans. In a radiation proctitis rat model, a significant reduction in crypt injury is demonstrated with the device compared to without (p < 0.0087). Optimal device placement for radiation attenuation is further confirmed in a swine model. Dosimetric modeling in oral cavity cancer patients demonstrates a 30% radiation dose reduction to the normal buccal mucosa and a 15.2% dose reduction in the rectum for prostate cancer patients with the radioprotectant material in place compared to without. Finally, it is found that the rectal radioprotectant device is more cost-effective compared to a hydrogel rectal spacer. Taken together, these data suggest that personalized radioprotectant devices may be used to reduce GI tissue injury in cancer patients undergoing therapeutic radiation.
Oral administration provides a simple and non-invasive approach for drug delivery. However, due to poor absorption and swift enzymatic degradation in the gastrointestinal tract, a wide range of molecules must be parenterally injected to attain required doses and pharmacokinetics. Here we present an orally dosed liquid auto-injector capable of delivering up to 4-mg doses of a bioavailable drug with the rapid pharmacokinetics of an injection, reaching an absolute bioavailability of up to 80% and a maximum plasma drug concentration within 30 min after dosing. This approach improves dosing efficiencies and pharmacokinetics an order of magnitude over our previously designed injector capsules and up to two orders of magnitude over clinically available and preclinical chemical permeation enhancement technologies. We administered the capsules to swine for delivery of clinically relevant doses of four commonly injected medications, including adalimumab, a GLP-1 analog, recombinant human insulin and epinephrine. These multi-day dosing experiments and oral administration in awake animal models support the translational potential of the system.
Diurnal variation in enzymes, hormones, and other biological mediators has long been recognized in mammalian physiology. Developments in pharmacobiology over the past few decades have shown that timing drug delivery can enhance drug efficacy. Here, we report the development of a battery-free, refillable, subcutaneous, and trocar-compatible implantable system that facilitates chronotherapy by enabling tight control over the timing of drug administration in response to external mechanical actuation. The external wearable system is coupled to a mobile app to facilitate control over dosing time. Using this system, we show the efficacy of bromocriptine on glycemic control in a diabetic rat model. We also demonstrate that antihypertensives can be delivered through this device, which could have clinical applications given the recognized diurnal variation of hypertension-related complications. We anticipate that implants capable of chronotherapy will have a substantial impact on our capacity to enhance treatment effectiveness for a broad range of chronic conditions.
OBJECTIVES:To compare the impact of respirator extended use and reuse strategies with regard to cost and sustainability during the COVID-19 pandemic. DESIGN:Cost analysis. SETTING:USA. PARTICIPANTS:All healthcare workers within the USA. INTERVENTIONS:Not applicable. MAIN OUTCOME MEASURES:A model was developed to estimate usage, costs and waste incurred by several respirator usage strategies over the first 6 months of the pandemic in the USA. This model assumed universal masking of all healthcare workers. Estimates were taken from the literature, government databases and commercially available data from approved vendors. RESULTS:A new N95 respirator per patient encounter would require 7.41 billion respirators, cost $6.38 billion and generate 84.0 million kg of waste in the USA over 6 months. One respirator per day per healthcare worker would require 3.29 billion respirators, cost $2.83 billion and generate 37.22 million kg of waste. Decontamination by ultraviolet germicidal irradiation would require 1.64 billion respirators, cost $1.41 billion and accumulate 18.61 million kg of waste. H2O2 vapour decontamination would require 1.15 billion respirators, cost $1.65 billion and produce 13.03 million kg of waste. One reusable respirator with daily disposable filters would require 18 million respirators, cost $1.24 billion and generate 15.73 million kg of waste. Pairing a reusable respirator with H2O2 vapour-decontaminated filters would reduce cost to $831 million and generate 1.58 million kg of waste. The use of one surgical mask per healthcare worker per day would require 3.29 billion masks, cost $460 million and generate 27.92 million kg of waste. CONCLUSIONS:Decontamination and reusable respirator-based strategies decreased the number of respirators used, costs and waste generated compared with single-use or daily extended-use of disposable respirators. Future development of low-cost,simple technologies to enable respirator and/or filter decontamination is needed to further minimise the economic and environmental costs of masks.