A polarized neutron beam and the Nab spectrometer (pNAB) at the Spallation Neutron Source will enable simultaneous measurements of the beta (A) and neutrino (B) asymmetries in free neutron decay. Combined Nab and pNAB measurements of the correlation parameters a, A, and B will determine the axial-vector to vector coupling ratio in the weak interaction with a precision of about 0.025%. Neutrons are polarized with supermirror polarizers and analyzed with polarized 3He. Together with precise neutron lifetime measurements, these results will provide the most stringent test of Cabibbo-Kobayashi-Maskawa (CKM) matrix unitarity from free neutron decay.
This paper presents a new technique to study the adsorption and desorption of ions and electrons on insulating surfaces in the presence of strong electric fields in cryoliquids. The experimental design consists of a compact cryostat coupled with a sensitive electro-optical Kerr device to monitor the stability of the electric fields. The behavior of nitrogen and helium ions on a poly(methyl methacrylate) (PMMA) surface was compared to a PMMA surface coated with a mixture of deuterated polystyrene and deuterated polybutadiene. Ion accumulation and removal on these surfaces were unambiguously observed. Within the precision of the data, both surfaces behave similarly for the physisorbed ions. The setup was also used to measure the (quasi-)static dielectric constant of PMMA at T = 70 K. The impact of the ion adsorption on the search for a neutron permanent electric dipole moment in a cryogenic environment, like the nEDM@SNS experiment, is discussed.
Fundamental neutron physics, combining precision measurements and theory, probes particle physics at short range with reach well beyond the highest energies probed by the LHC. Significant US efforts are underway that will probe BSM CP violation with orders of magnitude more sensitivity, provide new data on the Cabibbo anomaly, more precisely measure the neutron lifetime and decay, and explore hadronic parity violation. World-leading results from the US Fundamental Neutron Physics community since the last Long Range Plan, include the world's most precise measurement of the neutron lifetime from UCN$\tau$, the final results on the beta-asymmetry from UCNA and new results on hadronic parity violation from the NPDGamma and n-${^3}$He runs at the FNPB (Fundamental Neutron Physics Beamline), precision measurement of the radiative neutron decay mode and n-${}^4$He at NIST. US leadership and discovery potential are ensured by the development of new high-impact experiments including BL3, Nab, LANL nEDM and nEDM@SNS. On the theory side, the last few years have seen results for the neutron EDM from the QCD $\theta$ term, a factor of two reduction in the uncertainty for inner radiative corrections in beta-decay which impacts CKM unitarity, and progress on {\it ab initio} calculations of nuclear structure for medium-mass and heavy nuclei which can eventually improve the connection between nuclear and nucleon EDMs. In order to maintain this exciting program and capitalize on past investments while also pursuing new ideas and building US leadership in new areas, the Fundamental Neutron Physics community has identified a number of priorities and opportunities for our sub-field covering the time-frame of the last Long Range Plan (LRP) under development. This white paper elaborates on these priorities.
Neutron transport computations employ thermal scattering laws (TSLs) to account for the influence of material structure and collective excitations at low energy (< 10 eV). Recent work has been undertaken to improve TSL accuracy and expand the number of available materials in the Evaluated Nuclear Data File (ENDF). However, comparison of TSL to measured data is often sparse. We present a method to evaluate TSL accuracy in the Monte Carlo N-Particle (MCNP) code by simulating inelastic neutron scattering (INS) measurement and comparing to data. The method is briefly described with example application to the recently released ENDF-VIII TSL library for polyethylene as well as a cryogenic PE TSL we are separately developing.
We have experimentally studied growing a large (about 1 liter) ortho-deuterium crystal in a real UCN source cryostat and recorded the growing process optically using a camera. The best quality was observed when growing the crystal directly from a vapor phase. The crystal was grown at different mass flows of deuterium and annealed at different temperatures. Optimum conditions were found for both, obtaining an optically transparent crystal and cooling it down with minimal damage. We found that the quality, final shape and changes during annealing of the crystal are very much dependent on the temperature profile of the cryostat walls.
Differential cross sections for elastic Compton scattering from $^4$He have been measured with high statistical precision at the High Intensity $\gamma$-ray Source at laboratory scattering angles of $55^\circ$, $90^\circ$, and $125^\circ$ using a quasi-monoenergetic photon beam with a weighted mean energy value of $81.3$ MeV. The results are compared to previous measurements and similar fore-aft asymmetry in the angular distribution of the differential cross sections is observed. This experimental work is expected to strongly motivate the development of effective-field-theory calculations of Compton scattering from $^4$He to fully interpret the data.
The physics model of a next-generation spallation-driven high-current ultracold neutron (UCN) source capable of delivering an extracted UCN rate of around an-order-of-magnitude higher than the strongest proposed sources, and around three-orders-of-magnitude higher than existing sources, is presented. This UCN-current-optimized source would dramatically improve cutting-edge UCN measurements that are currently statistically limited. A novel "Inverse Geometry" design is used with 40 L of superfluid $^4$He (He-II), which acts as a converter of cold neutrons (CNs) to UCNs, cooled with state-of-the-art sub-cooled cryogenic technology to $\sim$1.6 K. Our design is optimized for a 100 W maximum heat load constraint on the He-II and its vessel. In our geometry, the spallation target is wrapped symmetrically around the UCN converter to permit raster scanning the proton beam over a relatively large volume of tungsten spallation target to reduce the demand on the cooling requirements, which makes it reasonable to assume that water edge-cooling only is sufficient. Our design is refined in several steps to reach $P_{UCN}=2.1\times10^9\,/$s under our other restriction of 1 MW maximum available proton beam power. We then study effects of the He-II scattering kernel as well as reductions in $P_{UCN}$ due to pressurization to reach $P_{UCN}=1.8\times10^9\,/$s. Finally, we provide a design for the UCN extraction system that takes into account the required He-II heat transport properties and implementation of a He-II containment foil that allows UCN transmission. We estimate a total useful UCN current from our source of $R_{use}=5\times10^8\,/$s from a 18 cm diameter guide 5 m from the source. Under a conservative "no return" approximation, this rate can produce an extracted density of $>1\times10^4\,/$cm$^3$ in $<$1000~L external experimental volumes with a $^{58}$Ni (335 neV) cut-off potential.
A cryogenic apparatus is described that enables a new experiment, nEDM@SNS, with a major improvement in sensitivity compared to the existing limit in the search for a neutron Electric Dipole Moment (EDM). This apparatus uses superfluid 4He to produce a high density of Ultra-Cold Neutrons (UCN) which are contained in a suitably coated pair of measurement cells. The experiment, to be operated at the Spallation Neutron Source at Oak Ridge National Laboratory, uses polarized 3He from an Atomic Beam Source injected into the superfluid 4He and transported to the measurement cells where it serves as a co-magnetometer. The superfluid 4He is also used as an insulating medium allowing significantly higher electric fields, compared to previous experiments, to be maintained across the measurement cells. These features provide an ultimate statistical uncertainty for the EDM of 2−3× 10−28 e-cm, with anticipated systematic uncertainties below this level.
Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS) will implement the scheme of Golub & Lamoreaux [Phys. Rep., 237, 1 (1994)]. The unique properties of combining polarized ultracold neutrons, polarized 3He, and superfluid 4He will be exploited to provide a sensitivity to ∼ 10−28 e · cm. Our cryogenic apparatus will deploy two small (3 L) measurement cells with a high density of ultracold neutrons produced and spin analyzed in situ. The electric field strength, precession time, magnetic shielding, and detected UCN number will all be enhanced compared to previous room temperature Ramsey measurements. Our 3He co-magnetometer offers unique control of systematic effects, in particular the Bloch-Siegert induced false EDM. Furthermore, there will be two distinct measurement modes: free precession and dressed spin. This will provide an important self-check of our results. Following five years of “critical component demonstration,” our collaboration transitioned to a “large scale integration” phase in 2018. An overview of our measurement techniques, experimental design, and brief updates are described in these proceedings.
Solid deuterium (sD(2)) is used as an efficient converter to produce ultracold neutrons (UCN). It is known that the sD(2) must be sufficiently cold, of high purity and mostly in its ortho-state in order to guarantee long lifetimes of UCN in the solid from which they are extracted into vacuum. Also the UCN transparency of the bulk sD(2) material must be high because crystal inhomogeneities limit the mean free path for elastic scattering and reduce the extraction efficiency. Observations at the UCN sources at Paul Scherrer Institute and at Los Alamos National Laboratory consistently show a decrease of the UCN yield with time of operation after initial preparation or later treatment ("conditioning") of the sD(2). We show that, in addition to the quality of the bulk sD(2), the quality of its surface is essential. Our observations and simulations support the view that the surface is deteriorating due to a build-up of D-2 frost-layers under pulsed operation which leads to strong albedo reflections of UCN and subsequent loss. We report results of UCN yield measurements, temperature and pressure behavior of deuterium during source operation and conditioning, and UCN transport simulations. This, together with optical observations of sD(2) frost formation on initially transparent sD(2) in offline studies with pulsed heat input at the North Carolina State University UCN source, results in a consistent description of the UCN yield decrease.
We analyze the spin flip loss for ultracold neutrons in magnetic bottles of the type used in experiments aiming at a precise measurement of the neutron lifetime, extending the one-dimensional field model used previously by Steyerl $\textit{et al.}$ [Phys.Rev.C $\mathbf{86}$, 065501 (2012)] to two dimensions for cylindrical multipole fields. We also develop a general analysis applicable to three dimensions. Here we apply it to multipole fields and to the bowl-type field configuration used for the Los Alamos UCN$\tau$ experiment. In all cases considered the spin flip loss calculated exceeds the Majorana estimate by many orders of magnitude but can be suppressed sufficiently by applying a holding field of appropriate magnitude to allow high-precision neutron lifetime measurements, provided other possible sources of systematic error are under control.
Position-sensitive detection of ultracold neutrons (UCNs) is demonstrated using an imaging charge coupled device (CCD) camera. A spatial resolution less than 15 pm has been achieved, which is equivalent to a UCN energy resolution below 2 pico-electron-volts through the relation delta E = m(0)g delta x. Here, the symbols delta E, delta x, m(0) and g are the energy resolution, the spatial resolution, the neutron rest mass and the gravitational acceleration, respectively. A multilayer surface convertor described previously is used to capture UCNs and then emits visible light for CCD imaging. Particle identification and noise rejection are discussed through the use of light intensity profile analysis. This method allows different types of UCN spectroscopy and other applications. (C) 2016 Elsevier B.V. All rights reserved.
Ultracold neutrons (UCNs) were produced in superfluid helium using the PF1B cold-neutron beam facility at the Institut Laue-Langevin. A 4-liter beryllium-coated converter volume with a mechanical valve and windowless stainless-steel extraction system were used to accumulate and guide UCNs to a detector at room temperature. At a converter temperature of 1.08 K the total storage time constant in the vessel was (20.3 +/- 1.2) s and the number of UCNs counted after accumulated was 91 700 +/- 300. From this, we derive a volumetric UCN production rate of (6.9 +/- 1.7) cm(-3) s(-1), which includes a correction for losses in the converter during UCN extraction caused by the short storage time, but not accounting for UCN transport and detection efficiencies. The up-scattering rate of UCNs caused by excitations in the superfluid was studied by scanning the temperature between 1.2 K and 2.4 K. Using the temperature-dependent UCN production rate calculated from inelastic neutron scattering data, the only UCN up-scattering process found to occur was from two-phonon scattering. Our analysis for T < 1.95 K rules out the contributions from roton-phonon scattering to <29% (95% C.I.) and from one-phonon absorption to <47% (95% C.I.) of their predicted levels.
Ultracold neutron (UCN) storage measurements were made in a trap constructed from a 1.3 T Halbach Octupole PErmanent (HOPE) magnet array aligned vertically, using the TES-port of the PF2 source at the Institut Laue-Langevin. A mechanical UCN valve at the bottom of the trap was used for filling and emptying. This valve was covered with Fomblin grease to induce non-specular reflections and was used in combination with a movable polyethylene UCN remover inserted from the top for cleaning of above-threshold UCNs. Loss due to UCN depolarization was suppressed with a minimum 2 mT bias field. Without using the UCN remover, a total storage time constant of $(712 \pm 19)$ s was observed; with the remover inserted for 80 s and used at either 80 cm or 65 cm from the bottom of the trap, time constants of $(824 \pm 32)$ s and $(835 \pm 36)$ s were observed. Combining the latter two values, a neutron lifetime of $\tau_{\rm n} = (887 \pm 39)$ s is extracted after primarily correcting for losses at the UCN valve. The time constants of the UCN population during cleaning were observed and compared to calculations based on UCN kinetic theory as well as Monte-Carlo studies. These calculations are used to predict above-threshold populations of $\sim 5\%$, $\sim 0.5\%$ and $\sim 10^{-12}\%$ remaining after cleaning in the no remover, 80~cm remover and 65~cm remover measurements. Thus, by using a non-specular reflector covering the entire bottom of the trap and a remover at the top of the trap, we have established an effective cleaning procedure for removing a major systematic effect in high-precision $\tau_{\rm n}$ experiments with magnetically stored UCNs.
We investigate experimentally the pressure dependence of the production of ultracold neutrons (UCNs) in superfluid helium in the range from saturated vapor pressure to 20 bar. A neutron velocity selector allows the separation of underlying single-phonon and multiphonon processes by varying the incident cold neutron (CN) wavelength in the range from 3.5 to 10 angstrom. The predicted pressure dependence of UCN production derived from inelastic neutron scattering data is confirmed for the single-phonon excitation. For multiphonon-based UCN production we found no significant dependence on pressure, whereas calculations from inelastic neutron scattering data predict an increase of 43(6)% at 20 bar relative to saturated vapor pressure. From our data we conclude that applying pressure to superfluid helium does not increase the overall UCN production rate at a typical CN guide.