Magnetic resonance spectroscopy (MRS) enables non-invasive assessment of brain metabolites and is commonly implemented using single-voxel spectroscopy (SVS) or magnetic resonance spectroscopic imaging (MRSI). This study directly compares the reproducibility of SVS-based semi-localization by adiabatic selective refocusing (sLASER) and 3D-Concentric Ring Trajectory-based Free Induction Decay MRSI (3D-CRT-FID-MRSI) at 3T and 7T in the same cohort of healthy participants. To explore MRSI's capabilities for regional metabolite quantification and reproducibility assessment, three masking strategies were applied. Additionally, two spatial averaging approaches for MRSI, averaging before vs. after spectral fitting, were evaluated. Coefficients of variation (CV) and voxel-wise correlation analyses were used to assess intra-subject and inter-session reproducibility. Results showed good-to-excellent reproducibility across both techniques, with SVS generally providing lower CVs at 7T, while MRSI outperformed SVS in several metabolites at 3T. MRSI allowed tissue-specific analysis, with lower CVs observed in WM compared to GM, especially at 7T. Although MRSI reproducibility was slightly reduced at 7T likely due to longer scan times and lack of prospective motion correction, the spatial coverage and retrospective region analysis makes it an attractive alternative to SVS for many brain regions. This study demonstrates that both sLASER and CRT-FID-MRSI provide reproducible metabolite measurements at 3T and 7T. The findings highlight MRSI's advantages for retrospective multi-regional and tissue-specific analysis, facilitating its integration into future clinical research.
Magnetic Resonance Spectroscopic Imaging (MRSI) enables non-invasive mapping of brain metabolite concentrations but remains computationally intensive and challenging due to a low signal-to-noise ratio (SNR) and overlapping spectral features. Traditional spectral fitting methods, such as LCModel, are time-consuming and often lack comprehensive uncertainty quantification. In this study, we propose Physics-Informed Variational Encoder (PHIVE), a novel deep learning framework that integrates physics-based priors into a variational autoencoder architecture for rapid and accurate metabolite quantification. PHIVE enables simultaneous estimation of metabolite concentrations and uncertainty metrics, including Cramér-Rao Lower Bound (CRLB), aleatoric, and epistemic uncertainties. PHIVE is evaluated on whole-brain MRSI data from 7T acquisitions of healthy controls and multiple sclerosis (MS) patients. The method achieved comparable accuracy to LCModel for key metabolites, such as Total N-acetylaspartate (tNAA), Glutamate-Glutamine complex (Glx), and Myo-inositol (mIns) while demonstrating a six-order-of-magnitude reduction in computational time (6 ms per dataset). Uncertainty quantification highlighted PHIVE's robustness in regions with low SNR. Additionally, a conditional baseline modeling approach is introduced, enabling dynamic flexibility in spectral baseline estimation during inference time. These results suggest that PHIVE offers a fast, reliable, and interpretable solution for high-resolution metabolite quantification, paving the way for real-time MRSI applications in clinical and research settings. Future work will focus on expanding its validation across diverse datasets and investigating its utility in longitudinal and multi-center studies. Our code is available at https://github.com/amirshamaei/PHIVE.
Introduction: Ultra-high-field magnetic resonance (MR) systems (7 T and 9.4 T) offer the ability to probe human brain metabolism with enhanced precision. Here, we present the preliminary findings from 3D MR spectroscopic imaging (MRSI) of the human brain conducted with the world's first 10.5 T whole-body MR system. Methods: Employing a custom-built 16-channel transmit and 80-channel receive MR coil at 10.5 T, we conducted MRSI acquisitions in six healthy volunteers to map metabolic compounds in the human cerebrum in vivo. Three MRSI protocols with different matrix sizes and scan times (4.4 × 4.4 × 4.4 mm³: 10 min, 3.4 × 3.4 × 3.4 mm³: 15 min, and 2.75×2.75×2.75 mm³: 25 min) were tested. Concentric ring trajectories were utilized for time-efficient encoding of a spherical 3D k-space with ∼4 kHz spectral bandwidth. B0/B1 shimming was performed based on respective field mapping sequences and anatomical T1-weighted MRI were obtained. Results: By combining the benefits of an ultra-high-field system with the advantages of free-induction-decay (FID-)MRSI, we present the first metabolic maps acquired at 10.5 T in the healthy human brain at both high (voxel size of 4.4³ mm³) and ultra-high (voxel size of 2.75³ mm³) isotropic spatial resolutions. Maps of 13 metabolic compounds (aspartate, choline compounds and creatine + phosphocreatine, γ-aminobutyric acid (GABA), glucose, glutamine, glutamate, glutathione, myo-inositol, scyllo-inositol, N-acetylaspartate (NAA), N-acetylaspartylglutamate (NAAG), taurine) and macromolecules were obtained individually. The spectral quality was outstanding in the parietal and occipital lobes, but lower in other brain regions such as the temporal and frontal lobes. The average total NAA (tNAA = NAA + NAAG) signal-to-noise ratio over the whole volume of interest was 12.1± 8.9 and the full width at half maximum of tNAA was 24.7± 9.6 Hz for the 2.75 × 2.75 × 2.75 mm³ resolution. The need for an increased spectral bandwidth in combination with spatio-spectral encoding imposed significant challenges on the gradient system, but the FID approach proved very robust to field inhomogeneities of ∆B0 = 45 ± 38 Hz (frequency offset ± spatial STD) and B1+ = 65 ± 11° within the MRSI volume of interest. Discussion: These preliminary findings highlight the potential of 10.5 T MRSI as a powerful imaging tool for probing cerebral metabolism. By providing unprecedented spatial and spectral resolution, this technology could offer a unique view into the metabolic intricacies of the human brain, but further technical developments will be necessary to optimize data quality and fully leverage the capabilities of 10.5 T MRSI.
Cerebrospinal fluid (CSF) flow is a key component of the brain's waste clearance system. However, our understanding of CSF flow in the human brain, particularly within the brain-wide subarachnoid space (SAS), is limited due to a lack of non-invasive tools for measuring slow flow. Here, we propose a CSF flowmetry technique using phase-contrast MRI combined with a slow-flow-sensitized acquisition. It achieves high sensitivity in measuring slow CSF flow (e.g., 100 μm/s), and enables quantitative measurement of the velocity and direction with whole-brain coverage, spanning from ventricles to SAS. Our proof-of-concept results demonstrate repeatable flow measurements and show that cardiac pulsation induces coherent CSF flow changes within the SAS. Our data also suggest that cardiac pulsation has a stronger driving effect on brain-wide CSF flow compared to respiration. This technique provides a valuable tool for investigating CSF dynamics and pathways to advance a holistic understanding of brain-wide CSF flow.
Dynamic deuterium (2H)-MRSI enables mapping of metabolic fluxes in vivo, but its sensitivity is hampered by the low 2H gyromagnetic ratio and 2H-labelled metabolite concentrations. Low-rank denoising can enhance MRSI sensitivity by separating signal from noise. Several methods have been proposed, but the optimal approach for dynamic 2H-MRSI remains unclear. This work compares six low-rank denoising methods for dynamic 2H-MRSI: four variations of spatiospectral partial separability (PS)-Global PS, Local PS, Stacked PS and SPectral and temporal INtegration for SVD (SPIN-SVD)-as well as global-local higher order singular value decomposition (GL-HOSVD) and tensor Marchenko-Pastur principal component analysis (tMPPCA). Performance was evaluated using realistic 2H-MRSI brain simulations across a range of noise and B0 inhomogeneity levels, including a lesion model featuring focal metabolic alteration, and in vivo data. For simulations at the in vivo SNR and B0 level, the concentration root-mean-square errors (RMSE) of the fitted metabolite maps against gold standard maps were reduced by 29.3%, 24.4%, 20.2%, 33.4%, 23.5% and 21.9% following denoising with Global PS, Local PS, Stacked PS, SPIN-SVD, GL-HOSVD and tMPPCA, respectively. Across all simulated noise levels and all but the highest B0 inhomogeneity level, SPIN-SVD achieved the lowest concentration RMSE and best preserved spatial distributions of 2H-labelled water (HDO) and lactate (Lac), including lesion-associated changes. While Global PS and Stacked PS reduced noise variance, they failed to preserve signal variations in simulated and in vivo data. SPIN-SVD, GL-HOSVD and tMPPCA reduced noise in vivo while maintaining spatial and temporal metabolite variations. GL-HOSVD and tMPPCA performed similarly, with tMPPCA preferred for its computational efficiency. Both SPIN-SVD and tMPPCA are suitable for denoising dynamic 2H-MRSI, with SPIN-SVD preferable for clinical applications owing to its simple implementation and superior preservation of local metabolic alterations, and tMPPCA better suited for absolute quantification of very low SNR metabolites.
Statistical Parametric Mapping (SPM) is an integrated set of methods for testing hypotheses about the brain's structure and function, using data from imaging devices. These methods are implemented in an open source software package, SPM, which has been in continuous development for more than 30 years by an international community of developers. This paper reports the release of SPM 25.01, a major new version of the software that incorporates novel analysis methods, optimisations of existing methods, as well as improved practices for open science and software development.
Abstract Background Phantom limb pain (PLP) is a restrictive condition in which patients perceive pain in a limb that is no longer present, greatly reducing their quality of life. Mirror Therapy, wherein patients observe a mirror reflection of their intact limb, has demonstrated efficacy in alleviating PLP. However, its unilateral and seated nature presents limitations. To address these constraints while still reducing PLP, and evaluating the impact of different virtual limb representations (anthropomorphic vs. non-anthropomorphic) on the user’s sense of ownership, agency, and embodiment, PhantomAR was developed. Leveraging wearable first-person augmented reality (AR) technology, PhantomAR extends traditional Mirror Therapy by enabling users to move freely and engage in bimanual tasks. Methods The assistive mixed reality game application PhantomAR was deployed on the Microsoft HoloLens 2 and augmented the user’s residual limb by superimposing a virtual arm or tentacle that was controlled via residual muscles on their stump using an EMG electrode array. This setup allowed patients to engage in a first-person perspective and manipulate virtual objects with both the healthy and augmented limbs, free from the confines of a seated position. The study enrolled 10 able-bodied individuals and 8 individuals with unilateral, transradial amputation. All amputees experienced PLP. The usability of the PhantomAR application was evaluated using the System Usability Scale (SUS) and a user-centric survey. Additionally, the Game Experience was assessed on a 5-point Likert questionnaire (GEQ). Participants rated their phantom sensations using the Numerical Rating Scale and McGill Pain Questionnaire before, during, and after interaction with PhantomAR. The embodiment and agency of the virtual superimposed arm were evaluated with an altered Prosthesis Embodiment Scale. The study protocol included two sessions of 30 min each, during which participants experienced PhantomAR. Results Participants (n = 18) rated PhantomAR highly usable (SUS m = 90.8%, SD = 6.88). Feedback on the Game Experience Questionnaire was overwhelmingly positive, showing high immersion (m = 4.46, SD = 0.08) and positive affect (m = 4.97, SD = 0.05). PLP (n = 8) significantly decreased post-intervention (NRS and McGill Pain Questionnaire, p < .001). Skin temperature in the residual limb increased significantly post-intervention (p < .01) but did not correlate with PLP (r = − 0.08, p = 0.83). Tentacle overlay yielded mixed ownership but high agency ratings. Conclusion PhantomAR leverages mixed reality to significantly reduce Phantom Limb Pain, enhance user engagement, and alter perceptions of ownership and agency of their augmented limb through bi-manual, dynamic, full-body interactions. Trial registration DRKS00033208 (Jan. 5th 2024)
Neuroimaging data analysis often requires purpose-built software, which can be challenging to install and may produce different results across computing environments. Beyond being a roadblock to neuroscientists, these issues of accessibility and portability can hamper the reproducibility of neuroimaging data analysis pipelines. Here, we introduce the Neurodesk platform, which harnesses software containers to support a comprehensive and growing suite of neuroimaging software (https://www.neurodesk.org/). Neurodesk includes a browser-accessible virtual desktop environment and a command line interface, mediating access to containerized neuroimaging software libraries on various computing platforms, including personal and high-performance computers, cloud computing and Jupyter Notebooks. This community-oriented, open-source platform enables a paradigm shift for neuroimaging data analysis, allowing for accessible, flexible, fully reproducible, and portable data analysis pipelines.
The boundaries between tissues with different magnetic susceptibilities generate inhomogeneities in the main magnetic field which change over time due to motion, respiration and system instabilities. The dynamically changing field can be measured from the phase of the fMRI data and corrected. However, methods for doing so need multi-echo data, time-consuming reference scans and/or involve error-prone processing steps, such as phase unwrapping, which are difficult to implement robustly on the MRI host. The improved dynamic distortion correction method we propose is based on the phase of the single-echo EPI data acquired for fMRI, phase offsets calculated from a triple-echo, bipolar reference scan of circa 3-10 s duration using a method which avoids the need for phase unwrapping and an additional correction derived from one EPI volume in which the readout direction is reversed. This Reverse-Encoded First Image and Low resoLution reference scan (REFILL) approach is shown to accurately measure B0 as it changes due to shim, motion and respiration, even with large dynamic changes to the field at 7 T, where it led to a > 20% increase in time-series signal to noise ratio compared to data corrected with the classic static approach. fMRI results from REFILL-corrected data were free of stimulus-correlated distortion artefacts seen when data were corrected with static field mapping. The method is insensitive to shim changes and eddy current differences between the reference scan and the fMRI time series, and employs calculation steps that are simple and robust, allowing most data processing to be performed in real time on the scanner image reconstruction computer. These improvements make it feasible to routinely perform dynamic distortion correction in fMRI.
Phantom limb pain (PLP) is a restrictive condition in which patients perceive pain in a non-existent limb, incapacitating them from performing daily activities. Mirror therapy, during which patients look into a mirror reflecting their sound limb and imagining it as healthy on their amputated site, has proven to alleviate that pain. However, it is limited to unilateral movements which take place in a seated position We developed an assistive mixed reality (MR) tool on the Microsoft HoloLens 2 to extend conventional mirror therapy by enabling users to freely explore their environment and to perform bi-manual tasks. Thereby, the patient's residual limb was augmented by a superimposed virtual arm that is controlled by the residual limb. We evaluated the usability of this system with ten able-bodied individuals and two transradial amputees. Patients additionally rated the system for its motivational aspect using the IMI questionnaire and a user-centered survey. PhantomAR showed a high usability rate of 78.5%; immersion, positive affect and game flow were rated most highly in both patients, while PLP slightly decreased after using the application. We critically examined the use and implementation of a therapy environment on HoloLens 2 and proposed how to address potential pitfalls in development. Based on these findings, we expect the PhantomAR mixed reality therapy tool to positively impact the outcomes on PLP scores and motivation to carry out the therapy even in absence of a therapist.
Purpose Quantitative susceptibility mapping (QSM) estimates the spatial distribution of tissue magnetic susceptibilities from the phase of a gradient-echo signal. QSM algorithms require a signal mask to delineate regions with reliable phase for subsequent susceptibility estimation. Existing masking techniques used in QSM have limitations that introduce artifacts, exclude anatomical detail, and rely on parameter tuning and anatomical priors that narrow their application. Here, a robust masking and reconstruction procedure is presented to overcome these limitations and enable automated QSM processing. Moreover, this method is integrated within an open-source software framework: QSMxT. Methods A robust masking technique that automatically separates reliable from less reliable phase regions was developed and combined with a two-pass reconstruction procedure that operates on the separated sources before combination, extracting more information and suppressing streaking artifacts. Results Compared with standard masking and reconstruction procedures, the two-pass inversion reduces streaking artifacts caused by unreliable phase and high dynamic ranges of susceptibility sources. It is also robust across a range of acquisitions at 3 T in volunteers and phantoms, at 7 T in tumor patients, and in an in silico head phantom, with significant artifact and error reductions, greater anatomical detail, and minimal parameter tuning. Conclusion The two-pass masking and reconstruction procedure separates reliable from less reliable phase regions, enabling a more accurate QSM reconstruction that mitigates artifacts, operates without anatomical priors, and requires minimal parameter tuning. The technique and its integration within QSMxT makes QSM processing more accessible and robust to streaking artifacts.
After the amputation of a limb, up to 90% of the patients report a feeling of the missing body part still being present in their perception. This effect is known as phantom limb sensation and ranges from the simple feeling of presence to a specific position, shape or phantom pain. To alleviate this pain, patients engage in mirror therapy during which a mirror is placed in front of the patient’s midsection, and the patient, while looking into this mirror, imagines that the amputated limb is in fact the healthy limb reflected in the mirror. However, this method is not without limitations. To address these limitations of conventional Mirror Therapy therapy and take advantage of the inherent potential of commercial technology, we developed an innovative assistive therapy tool based on mixed reality (MR) on the Microsoft Hololens 2. In this way, the patient’s residual limb would be augmented by a superimposed virtual arm that is completely independent from the movements of their sound limb and can interact with the environment. Patients should move around freely and perform bi-manual tasks. To achieve this, we developed an MR appliaction that includes controllers for moving the virtual hand via myoelectric sensors (EMG) and inertial units and created and 4 different interaction scenes. We anticipate that this type of immersive MR rehabilitation will have a positive impact on outcomes related to pain scores, hand/arm functionality, range of motion, and motivation to perform therapy, even when no therapist is present.
To develop improved tissue masks for QSM.
PurposeTo explore the impact of temporal motion‐induced coil sensitivity changes on CEST‐MRI at 7T and its correction using interleaved volumetric EPI navigators, which are applied for real‐time motion correction.MethodsFive healthy volunteers were scanned via CEST. A 4‐fold correction pipeline allowed the mitigation of (1) motion, (2) motion‐induced coil sensitivity variations, , (3) motion‐induced static magnetic field inhomogeneities, ΔB0, and (4) spatially varying transmit RF field fluctuations, . Four CEST measurements were performed per session. For the first 2, motion correction was turned OFF and then ON in absence of voluntary motion, whereas in the other 2 controlled head rotations were performed. During post‐processing was removed additionally for the motion‐corrected cases, resulting in a total of 6 scenarios to be compared. In all cases, retrospective ∆B0 and ‐ corrections were performed to compute artifact‐free magnetization transfer ratio maps with asymmetric analysis (MTRasym).ResultsDynamic correction successfully mitigated signal deviations caused by head motion. In 2 frontal lobe regions of volunteer 4, induced relative signal errors of 10.9% and 3.9% were reduced to 1.1% and 1.0% after correction. In the right frontal lobe, the motion‐corrected MTRasym contrast deviated 0.92%, 1.21%, and 2.97% relative to the static case for Δω = 1, 2, 3 ± 0.25 ppm. The additional application of correction reduced these deviations to 0.10%, 0.14%, and 0.42%. The fully corrected MTRasym values were highly consistent between measurements with and without intended head rotations.ConclusionTemporal cause significant CEST quantification bias. The presented correction pipeline including the proposed retrospective correction significantly reduced motion‐related artifacts on CEST‐MRI.
Fat fraction quantification and assessment of its distribution in the hepatic tissue become more important with the growing epidemic of obesity, and the increasing prevalence of diabetes mellitus type 2 and non-alcoholic fatty liver disease. At 3Tesla, the multi-echo, chemical-shift-encoded magnetic resonance imaging (CSE-MRI)-based acquisition allows the measurement of proton density fat-fraction (PDFF) even in clinical protocols. Further improvements in SNR can be achieved by the use of phased array coils and increased static magnetic field. The purpose of the study is to evaluate the feasibility of PDFF imaging using a multi-echo CSE-MRI technique at ultra-high magnetic field (7Tesla). Thirteen volunteers (M/F) with a broad range of age, body mass index, and hepatic PDFF were measured at 3 and 7T by multi-gradient-echo MRI and single-voxel spectroscopy MRS. All measurements were performed in breath-hold (exhalation); the MRI protocols were optimized for a short measurement time, thus minimizing motion-related problems. 7T data were processed off-line using Matlab® (MRI:multi-gradient-echo) and jMRUI (MRS), respectively. For quantitative validation of the PDFF results, a similar protocol was performed at 3T, including on-line data processing provided by the system manufacturer, and correlation analyses between 7 and 3T data were performed off-line. The multi-echo CSE-MRI measurements at 7T with a phased-array coil configuration and an optimal post-processing yielded liver volume coverage ranging from 30 to 90% for high- and low-BMI subjects, respectively. PDFFs ranged between 1 and 20%. We found significant correlations between 7T MRI and -MRS measurements (R2 ≅ 0.97; p < 0.005), and between MRI-PDFF at 7T and 3T fields (R2 ≅ 0.94; p < 0.005) in the evaluated volumes. Based on the measurements and analyses performed, the multi-echo CSE-MRI method using a 32-channel coil at 7T showed its aptitude for MRI-based quantitation of PDFF in the investigated volumes. The results are the first step toward qMRI of the whole liver at 7T with further improvements in hardware.
PURPOSE:Susceptibility Weighted Imaging (SWI) has become established in the clinical investigation of stroke, microbleeds, tumor vascularization, calcification and iron deposition, but suffers from a number of shortcomings and artefacts. The goal of this study was to reduce the sensitivity of SWI to strong B1 and B0 inhomogeneities at ultra-high field to generate homogeneous images with increased contrast and free of common artefacts. All steps in SWI processing have been addressed - coil combination, phase unwrapping, image combination over echoes, phase filtering and homogeneity correction - and applied to an efficient bipolar multi-echo acquisition to substantially improve the quality of SWI. PRINCIPAL RESULTS:Our findings regarding the optimal individual processing steps lead us to propose a Contrast-weighted, Laplace-unwrapped, bipolar multi-Echo, ASPIRE-combined, homogeneous, improved Resolution SWI, or CLEAR-SWI. CLEAR-SWI was compared to two other multi-echo SWI methods and standard, single-echo SWI with the same acquisition time at 7 T in 10 healthy volunteers and with single-echo SWI in 13 patients with brain tumors. CLEAR-SWI had improved contrast-to-noise and homogeneity, reduced signal dropout and was not compromised by the artefacts which affected standard SWI in 10 out of 13 cases close to tumors (as assessed by expert raters), as well as generating T2* maps and phase images which can be used for Quantitative Susceptibility Mapping. In a comparison with other multi-echo SWI methods, CLEAR-SWI had the fewest artefacts, highest SNR and generally higher contrast-to-noise. MAJOR CONCLUSIONS:CLEAR-SWI eliminates the artefacts common in standard, single-echo SWI, reduces signal dropouts and improves image homogeneity and contrast-to-noise. Applied clinically, in a study of brain tumor patients, CLEAR-SWI was free of the artefacts which affected standard, single-echo SWI.
OBJECT:This study evaluates inter-site and intra-site reproducibility at ten different 7 T sites for quantitative brain imaging. MATERIAL AND METHODS:Two subjects - termed the "traveling heads" - were imaged at ten different 7 T sites with a harmonized quantitative brain MR imaging protocol. In conjunction with the system calibration, MP2RAGE, QSM, CEST and multi-parametric mapping/relaxometry were examined. RESULTS:Quantitative measurements with MP2RAGE showed very high reproducibility across sites and subjects, and errors were in concordance with previous results and other field strengths. QSM had high inter-site reproducibility for relevant subcortical volumes. CEST imaging revealed systematic differences between the sites, but reproducibility was comparable to results in the literature. Relaxometry had also very high agreement between sites, but due to the high sensitivity, differences caused by different applications of the B1 calibration of the two RF coil types used were observed. CONCLUSION:Our results show that quantitative brain imaging can be performed with high reproducibility at 7 T and with similar reliability as found at 3 T for multicenter studies of the supratentorial brain.
PurposeTo develop a rapid and accurate MRI phase‐unwrapping technique for challenging phase topographies encountered at high magnetic fields, around metal implants, or postoperative cavities, which is sufficiently fast to be applied to large‐group studies including Quantitative Susceptibility Mapping and functional MRI (with phase‐based distortion correction).MethodsThe proposed path‐following phase‐unwrapping algorithm, ROMEO, estimates the coherence of the signal both in space—using MRI magnitude and phase information—and over time, assuming approximately linear temporal phase evolution. This information is combined to form a quality map that guides the unwrapping along a 3D path through the object using a computationally efficient minimum spanning tree algorithm. ROMEO was tested against the two most commonly used exact phase‐unwrapping methods, PRELUDE and BEST PATH, in simulated topographies and at several field strengths: in 3T and 7T in vivo human head images and 9.4T ex vivo rat head images.ResultsROMEO was more reliable than PRELUDE and BEST PATH, yielding unwrapping results with excellent temporal stability for multi‐echo or multi‐time‐point data. It does not require image masking and delivers results within seconds, even in large, highly wrapped multi‐echo data sets (eg, 9 seconds for a 7T head data set with 31 echoes and a 208 × 208 × 96 matrix size).ConclusionOverall, ROMEO was both faster and more accurate than PRELUDE and BEST PATH, delivering exact results within seconds, which is well below typical image acquisition times, enabling potential on‐console application.
Purpose In this study, we demonstrate the first combination of 3D FID proton MRSI and spatial encoding via concentric‐ring trajectories (CRTs) at 3T. FID‐MRSI has many benefits including high detection sensitivity, in particular for J‐coupled metabolites (e.g., glutamate/glutamine). This makes it highly attractive, not only for clinical, but also for, potentially, functional MRSI. However, this requires excellent reliability and temporal stability. We have, therefore, augmented this 3D‐FID‐MRSI sequence with single‐echo, imaging‐based volumetric navigators (se‐vNavs) for real‐time motion/shim‐correction (SHMOCO), which is 2× quicker than the original double‐echo navigators (de‐vNavs), hence allowing more efficient integration also in short‐TR sequences. Methods The tracking accuracy (position and B 0 ‐field) of our proposed se‐vNavs was compared to the original de‐vNavs in phantoms (rest and translation) and in vivo (voluntary head rotation). Finally, the intra‐session stability of a 5:40 min 3D‐FID‐MRSI scan was evaluated with SHMOCO and no correction (NOCO) in 5 resting subjects. Intra/inter‐subject coefficients of variation (CV) and intra‐class correlations (ICC) over the whole 3D volume and in selected regions of interest ROI were assessed. Results Phantom and in vivo scans showed highly consistent tracking performance for se‐vNavs compared to the original de‐vNavs, but lower frequency drift. Up to ~30% better intra‐subject CVs were obtained for SHMOCO ( P < 0.05), with values of 9.3/6.9/6.5/7.8% over the full VOI for Glx/tNAA/tCho/m‐Ins ratios to tCr. ICCs were good‐to‐high (91% for Glx/tCr in motor cortex), whereas the inter‐subject variability was ~11–19%. Conclusion Real‐time motion/shim corrected 3D‐FID‐MRSI with time‐efficient CRT‐sampling at 3T allows reliable, high‐resolution metabolic imaging that is fast enough for clinical use and even, potentially, for functional MRSI.