The preservation of a below-knee amputation (BKA) stump is essential for maintaining optimal limb function and facilitating future prosthetic use. Salvaging an infected stump is particularly challenging due to the loss of healthy soft tissue necessary to preserve adequate limb length. Patients with peripheral artery disease are often not considered candidates for complex reconstruction given concerns for poor perfusion, active smoking, and medical comorbidities. This case demonstrates a patient who underwent a BKA after failed revascularization for acute limb ischemia. Successful salvage of a BKA stump with a polymicrobial infection was achieved using an anterolateral thigh free flap with vastus lateralis muscle. At 4 months postoperatively, the patient was successfully ambulating with a prosthetic leg. This case demonstrates that advanced reconstruction for preservation of BKA stump may be feasible in patients with underlying peripheral artery disease.
OBJECTIVE:Radiation-induced carotid artery stenosis (RICS) is a well-described phenomenon seen after head and neck cancer radiation. Previously published literature suggests that, compared with atherosclerotic disease, RICS may result in worse long-term outcomes and early restenosis. This study aims to evaluate the effect of radiation on long-term outcomes after various carotid revascularization techniques using a multi-center registry database. METHODS:Patients in the Society for Vascular Surgery (SVS) Vascular Quality Initiative (VQI) registry for carotid artery intervention (carotid endarterectomy [CEA]; transfemoral carotid artery stenting [CAS]; transcarotid artery revascularization [TCAR]), who are 65 years or older were included in the study. VQI Vascular Implant Surveillance and Interventional Outcomes Network (VISION) Medicare-linked database was used to obtain long-term procedure-specific outcomes. Primary endpoints were 3-year death, stroke, and reintervention. We performed propensity matching between patients with prior radiation and those without. Kaplan-Meier analysis and a multivariate logistic regression model were used to analyze the outcome variables. RESULTS:A total of 56,472 patients had undergone carotid revascularization (CEA, n = 48,307; TCAR, n = 4593; CAS, n = 3572), 1244 patients with prior radiation and 54,925 patients without prior radiation. The prior radiation group was more likely to be male (71.9% vs 60.3%; P < .01), to receive a stent (47.5% vs 13.5%; P < .01), and to be on P2Y12 inhibitor (55.2% vs 38.3%; P < .01). Propensity matching was performed on 1223 patients (CEA, n = 655; TCAR, n = 292; CAS, n = 287). There were no significant differences in 30-day outcomes for death, stroke, or major adverse cardiovascular events for all three procedures. The prior radiation group had higher rates of cranial nerve injury (3.7% vs 1.8%; P = .04) and 90-day readmission (23.5% vs 18.3%; P = .01) after CEA. For long-term outcomes, prior radiation significantly increased mortality risk for CEA and CAS (hazard ratio [HR], 1.77; 95% confidence interval [CI], 1.38-2.27 and HR, 1.56; 95% CI, 1.02-2.36, respectively). The 3-year risk of stroke for CEA in radiated patients was also significantly higher (HR, 1.47; 95% CI, 1.03-2.09) compared with non-radiated patients. Prior radiation did not significantly affect death and stroke in patients undergoing TCAR. Prior radiation also did not impact the rates of short and long-term reintervention after CEA, CAS, or TCAR. CONCLUSIONS:Prior head and neck radiation significantly increases the risk for mortality and stroke for CEA and the risk for mortality after CAS. Long-term outcomes for TCAR are not significantly affected by prior radiation. TCAR may be the preferred treatment modality for patients with radiation-induced carotid stenosis.
Objective:Endovascular repair of chronic dissecting aortoiliac aneurysms is challenging given the rigid septum, compressed true lumen (TL), and target vessels frequently originating in the false lumen. We have used transcatheter electrosurgical aortic septotomy (TEAS) before stent graft implantation under intravascular ultrasound (IVUS) and fusion guidance. The purpose of this study is to assess the outcomes of TEAS during complex endovascular repair of dissecting aneurysms. Methods:From 2021 to 2023, 17 patients underwent TEAS. The primary end point was technical success, with secondary end points of proximal and distal seals, target vessel instability, aortic and iliac TL and cross-sectional area (CSA) expansion, and aortic-related death. During the procedure, the aortic septum is crossed through a pre-existing entry or via electrocautery-activated 0.018-in. Astato XS20 wire (Asahi-Intecc) under IVUS and fusion guidance. The penetrated wire is then snared in the false lumen and pulled through the ipsilateral femoral access. A 1-cm length of the middle of the Astato wire coating is kinked in a three-sided polygonal configuration, denuded the inner surface of the wire using a no. 15 blade, and positioned at the apex of the septum. Both ends of the Astato wire are insulated with 0.018-in. microcatheters, and the back end of the wire is denuded and connected to cautery. Gentle traction is applied to the wire, and short bursts of electrocautery cutting are applied at 60 to 80 W. Results:The technical success of the septotomy was 100%. No incidence of visceral or lower extremity malperfusion, vascular injury, or distal embolization occurred. Of the 17 patients, 4 underwent thoracic endovascular aneurysm repair, 2 underwent endovascular aortic repair, and 11 underwent fenestrated/branched endovascular aneurysm repair after septotomy. All target vessels were successfully stented. A distal landing zone seal with exclusion of the false lumen was achieved in 16 of the 17 patients (94.1%). One patient required embolization of the false lumen of the celiac artery after septotomy. The TL mean diameter and CSA of the descending thoracic aorta after septotomy was expanded by 7.01 ± 1.9 mm (relative mean diameter expansion, 42.3%; P < .0001) and 2.71 ± 0.4 cm2 (relative mean CSA expansion, 57.3%, P<.0001). For patients who required septotomy through the common iliac arteries, the mean TL was expanded by 8.1 ± 3.7 mm (relative mean diameter expansion, 76%; P < .0001) and 1.76 ± 0.91 cm2 (relative mean CSA expansion, 209%; P < .0001). The 1-year freedom from target vessel instability was 91%. Conclusions:The use of IVUS and fusion-guided TEAS offers a promising technique to facilitate TL expansion and false lumen exclusion in chronic dissecting aortic aneurysms before repair. The durability and long-term outcomes of this technique in a larger cohort remain to be elucidated.
We report the case of a 23-year-old female pedestrian who had been struck by a car and had presented with axillary artery transection in the setting of scapulothoracic dissociation. The initial endovascular repair was compromised by her shoulder instability and had required the addition of bridging stent placement. Caution is advised with endovascular repair in this clinical scenario because of possible stent separation.
Endovascular treatment options for vascular injury in pediatric patients are quite limited owing to concerns regarding long-term durability and the lack of devices suitable for the pediatric anatomy. However, in rare circumstances, open surgical therapy will not be an option, and patients will require unconventional endovascular solutions for lifesaving or limb-saving therapies. In the present report, we describe an endovascular treatment of a pediatric patient for whom initial surgical management of a blunt abdominal aortic injury had failed, with subsequent development of an aortic pseudoaneurysm. A 10-year-old girl had presented after a high-speed motor vehicle accident with a seatbelt sign. Multiple abdominal injuries were identified, including blunt aortic injury, significant devitalization of the small bowel, colonic perforation with fecal contamination, multiple lumbar spine fractures, and pulmonary contusions. The patient developed bilateral lower extremity ischemia from the aortic injury and had initially undergone open repair. One month later, the patient had developed a pseudoaneurysm of the aorta near the aortic bifurcation. Because of the hostile abdomen and ensuing short gut syndrome, the pseudoaneurysm was managed using endovascular techniques. The limb of an Excluder internal iliac branch endoprosthesis (W.L. Gore & Associates, Flagstaff, AZ) was used as the endograft. The aortic bifurcation was raised and reconstructed using four Viabahn self-expanding stents (W.L. Gore & Associates). The completion angiogram showed complete resolution of the pseudoaneurysm. The follow-up computed tomography angiogram showed widely patent stent grafts with complete resolution of the pseudoaneurysm. Endovascular management of traumatic vascular injuries in pediatric patients is feasible. The likelihood of reintervention in the future is high with patient growth. However, it is a viable option in lifesaving or limb-saving situations in which open repair is high risk.
Superior mesenteric artery aneurysms are rare and associated with high mortality rates in cases of rupture. Current Society for Vascular Surgery guidelines recommend treatment of all superior mesenteric artery aneurysms regardless of size. A 53-year-old woman who was admitted for abdominal pain was found with a 14-cm, ruptured superior mesenteric artery branch aneurysm. Endovascular approach was performed with microvascular plug embolization of a feeding branch and aneurysm sac exclusion with a stent graft. Four months later, the patient demonstrated a 21% regression of the aneurysm and stent patency. Thus, timely diagnosis and treatment of superior mesenteric artery aneurysms with endovascular techniques can reduce potential complications.
Genetic engineering and implantable bioelectronics have transformed investigations of cardiovascular physiology and disease. However, the two approaches have been difficult to combine in the same species: genetic engineering is applied primarily in rodents, and implantable devices generally require larger animal models. We recently developed several miniature cardiac bioelectronic devices suitable for mice and rats to enable the advantages of molecular tools and implantable devices to be combined. Successful implementation of these device-enabled studies requires microsurgery approaches that reliably interface bioelectronics to the beating heart with minimal disruption to native physiology. Here we describe how to perform an open thoracic surgical technique for epicardial implantation of wireless cardiac pacemakers in adult rats that has lower mortality than transvenous implantation approaches. In addition, we provide the methodology for a full biocompatibility assessment of the physiological response to the implanted device. The surgical implantation procedure takes ~40 min for operators experienced in microsurgery to complete, and six to eight surgeries can be completed in 1 d. Implanted pacemakers provide programmed electrical stimulation for over 1 month. This protocol has broad applications to harness implantable bioelectronics to enable fully conscious in vivo studies of cardiovascular physiology in transgenic rodent disease models.
Patients with acute aortoiliac occlusion typically present in extremis and require emergent revascularization using either aorta–bifemoral bypass (ABFB) or axillary–bifemoral bypass (AxBFB). Studies in the elective setting have shown AxBFB to result in lower morbidity and mortality compared with ABFB in high-risk patients. However, data in the emergent setting are lacking. We compared the outcomes for patients undergoing ABFB and AxBFB in the emergent setting. The 2005 to 2019 American College of Surgeons National Surgical Quality Improvement Program database was used to identify the patients who had undergone ABFB or AxBFB using the Common Procedural Terminology codes 35646 and 35654, respectively. Emergent cases with the International Classification of Diseases, 9th or 10th, revision, codes for acute aortoiliac occlusion were included. The outcomes of interest were 30-day mortality, major adverse cardiac events (including stroke, myocardial infarction, cardiac arrest), pulmonary and renal complications, operative time, bleeding requiring transfusion, a return to the operating room, wound infection, length of stay, and discharge destination. Statistical analysis was performed using two different methods: 1) multivariable analysis to correct for differences in preoperative patient characteristics; and 2) propensity score matching (PSM) to ensure clinically comparable patient characteristics between the ABFB and AxBFB groups. A total of 95 ABFB and 129 AxBFB emergent procedures were identified in the 2005 to 2019 database. The patients undergoing AxBFB were more likely to be women and older, have lower hematocrit and platelets, require preoperative transfusion, have chronic renal insufficiency, and have American Society of Anesthesiologists class 4 or 5. Although the initial univariable analysis showed AxBFB resulted in significantly greater 30-day mortality than did ABFB (36% vs 16%; P < .01), both multivariable and PSM analysis revealed comparable outcomes between AxBFB and ABFB, except for pulmonary events. After correcting for patient risk factors via multivariable analysis and, subsequently, 1:1 PSM, only pulmonary events remained significantly different between the two groups (33.3% ABFB vs 11.9% AxBFB; odds ratio, 3.7; 95% confidence interval, 1.23-11.17; P = .02; Table). The associated higher mortality with emergent AxBFB likely results from the selection of higher comorbid patients for the procedure. With the selection bias removed, AxBFB does not reduce mortality but does reduce the incidence of significant pulmonary complications. ABFB might be an acceptable option in the emergent setting for patients with good pulmonary function.TableThirty-day outcomes stratified by treatment group after 1:1 PSM30-Day outcomeABFB (n = 42)AxBFB (n = 42)Univariable P valueOR (ABFB)95% CIP valueMortality10 (23.81)11 (26.19)1.00000.880.31-2.46.81MACE6 (14.29)7 (16.67)1.00000.830.29-2.43.74Wound infection0 (0)6 (14.29).0258NANANARenal complications5 (11.9)4 (9.52)1.00001.280.30-5.59.74Sepsis6 (14.29)6 (14.29)1.00001.000.27-3.741.00DVT2 (4.76)1 (2.38)1.00002.050.17-24.47.57Pulmonary complications14 (33.33)5 (11.9).03523.701.23-11.17.02Return to operating room11 (26.19)10 (23.81)1.00001.140.46-2.79.78Operative time >4 hours18 (42.86)14 (33.33).501.500.68-3.31.31Length of stay >10 days16 (38.1)10 (23.81).23771.970.82-4.74.13Non–home discharge11 (32.35)11 (35.48).79980.820.33-2.00.66ABFB, Aorta–bifemoral bypass; AxBFB, axillary–bifemoral bypass; CI, confidence interval; DVT, deep vein thrombosis; MACE, major adverse cardiac events; NA, not applicable; OR, odds ratio; PSM, propensity score matching.Data presented as number (%).Boldface P values represent statistical significance. Open table in a new tab
Flexible electronic/optoelectronic systems that can intimately integrate onto the surfaces of vital organ systems have the potential to offer revolutionary diagnostic and therapeutic capabilities relevant to a wide spectrum of diseases and disorders. The critical interfaces between such technologies and living tissues must provide soft mechanical coupling and efficient optical/electrical/chemical exchange. Here, we introduce a functional adhesive bioelectronic-tissue interface material, in the forms of mechanically compliant, electrically conductive, and optically transparent encapsulating coatings, interfacial layers or supporting matrices. These materials strongly bond both to the surfaces of the devices and to those of different internal organs, with stable adhesion for several days to months, in chemistries that can be tailored to bioresorb at controlled rates. Experimental demonstrations in live animal models include device applications that range from battery-free optoelectronic systems for deep-brain optogenetics and subdermal phototherapy to wireless millimetre-scale pacemakers and flexible multielectrode epicardial arrays. These advances have immediate applicability across nearly all types of bioelectronic/optoelectronic system currently used in animal model studies, and they also have the potential for future treatment of life-threatening diseases and disorders in humans.
OBJECTIVES Factors such as more diffuse atherosclerosis, plaque instability and accelerated vascular calcification in patients with chronic and end-stage renal disease (ESRD) can potentially present intraoperative challenges in coronary artery bypass grafting (CABG) procedures. We evaluated whether patients with chronic and ESRD experienced more surgical strategy changes and/or graft revisions than patients with normal renal function when undergoing CABG procedures according to a protocol for intraoperative high-frequency ultrasound and transit-time flow measurement (TTFM). METHODS Outcomes of CABG for patients with chronic and ESRD and patients with normal renal function enrolled in the multicentre prospective REQUEST (REgistry for QUality assESsmenT with Ultrasound Imaging and TTFM in Cardiac Bypass Surgery) study were compared retrospectively. The primary end point was frequency of intraoperative surgical strategy changes. The secondary end point was post-protamine TTFM parameters. RESULTS There were 95 patients with chronic and ESRD and 921 patients with normal renal function. Patients with chronic and ESRD undergoing CABG according to a protocol for intraoperative high-frequency ultrasound and TTFM had a higher rate of strategy changes overall [33.7% vs 24.3%; odds ratio (OR) = 1.58; 95% confidence interval (CI) = 1.01-2.48; P = 0.047] and greater revisions per graft (7.0% vs 3.4%; odds ratio = 2.14; 95% CI = 1.17-3.71; P = 0.008) compared to patients with normal renal function. Final post-protamine graft TTFM parameters were comparable between cohorts. CONCLUSIONS Patients with chronic and ESRD undergoing CABG procedures with high-frequency ultrasound and TTFM experience more surgical strategy changes than patients with normal renal function while achieving comparable graft flow. Clinical trial registration number: ClinicalTrials.gov NCT02385344.
Objective: Although fenestrated endovascular aneurysm repair (FEVAR) has been associated with lower morbidity and mortality than open surgical repair (OSR) in juxtarenal aneurysms (JAAA), there is a paucity of data in the literature comparing outcomes of the approaches specifically in patients with chronic renal insufficiency (CRI). We hypothesized that benefits of FEVAR over OSR observed in the general patient population may be diminished in CRI patients due to their heightened vulnerability to renal dysfunction stemming from contrast-induced nephropathy. This study compares 30-day outcomes between FEVAR and OSR for JAAA in patients with non-dialysis dependent CRI. Methods: All adults with estimated glomerular filtration rate (eGFR) < 60 mL/min (but not requiring dialysis) undergoing elective, non-ruptured JAAA repairs were identified in the American College of Surgeons - National Surgical Quality Improvement (ACS-NSQIP) Targeted EVAR and AAA databases from 2012-2018. JAAA were identified by recorded proximal aneurysm extent. FEVAR patients were identified in the Targeted EVAR database as those receiving the "Cook Zenith Fenestrated" endograft. OSR cases were defined as those that required proximal clamp positions "above one renal" or "between SMA & renals." Infra-renal or supra-celiac proximal clamp placement, or cases involving concomitant renal/visceral revascularization were excluded. Thirty-day outcomes including mortality, major adverse cardiovascular events (MACE), pulmonary, and renal complications were compared between FEVAR and OSR groups. Results: There were 284 patients with CRI who underwent elective repair of JAAA (FEVAR: 89; OSR: 195). FEVAR patients were significantly older than those undergoing OSR (77.3 +/- 7.2 vs. 74.2 +/- 7.7, P = 0.001) and less likely to be smokers (25.8% vs 42.1%; P = 0.009). Other baseline demographic and pre-operative parameters were comparable between the two groups. Multivariable analysis revealed no significant difference between FEVAR and OSR in 30-day mortality (4.5% vs 4.6%; OR = 1.22; 95% CI = 0.35 4.22; P = 0.753) or unplanned re-operation (4.5% vs 5.1%; OR = 0.78; 95% CI = 0.22 2.70; P = 0.693). Patients undergoing FEVAR had significantly fewer pulmonary complications (3.4% vs 18.5%; OR = 0.12; 95% CI = 0.03 0.42; P < 0.001) and renal dysfunction (3.4% vs 11.8%; OR 0.24 95% CI = 0.07 0.86; P = 0.029) compared to OSR. FEVAR was also associated with significantly shorter ICU and hospital lengths of stay (ICU stay: 0 days vs 3 days, P < 0.0001; hospital stay: 3 days vs 8 days, P < 0.0001). Conclusion: For patients with chronic renal insufficiency, FEVAR offered improved perioperative renal morbidity compared to OSR without a corresponding mortality benefit. Future studies will be required to determine long term outcomes of this procedure in this vulnerable population.
Objective: Endovascular repair of juxtarenal abdominal aortic aneurysms (JAAAs) with fenestrated grafts (fenestrated endovascular aneurysm repair [FEVAR]) has been reported to decrease operative mortality and morbidity compared with open surgical repair (OSR). However, previous comparisons of OSR and FEVAR have not necessarily included patients with comparable clinical profiles and aneurysm extent. Although FEVAR has often been chosen as the first-line therapy for high-risk patients such as the elderly, many patients will not have anatomy favorable for FEVAR. At present, a paucity of data has examined the operative outcomes of OSR in elderly patients for JAAAs relative to FEVAR. Therefore, we chose to perform a propensity-matched comparison of OSR and FEVAR for JAAA repair in patients aged >= 70 years. Methods: Patients aged >= 70 years who had undergone elective nonruptured JAAA repairs from 2012 to 2018 were identified in the American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP) targeted endovascular aneurysm repair (EVAR) and AAA databases. Patients who had undergone FEVAR were identified in the targeted EVAR database as those who had received the Cook Zenith Fenestrated endograft (Cook Medical, Bloomington, Ind). Because our study specifically examined JAAAs, those patients who had undergone OSR with supraceliac proximal clamping or concomitant renal/visceral revascularization were excluded. A 1:1 propensity-match algorithm matched the OSR and FEVAR patients by preoperative clinical and demographic characteristics, operative indications, and aneurysm extent. The 30-day outcomes, including mortality, major adverse cardiovascular events, and pulmonary and renal complications, were compared between the propensity-matched OSR and FEVAR groups. Results: A 1:1 propensity match was achieved, and the final analysis included 136 OSR patients and 136 FEVAR patients. No significant differences were found in 30-day mortality (4.4% vs 3.7%; odds ratio [OR], 1.21; 95% confidence interval [CI], 0.36-4.06; P = .759) between the OSR and FEVAR groups. OSR was associated with a higher incidence of major adverse cardiovascular events compared with FEVAR; however, the trend was not statistically significant (8.1% vs 3.7%; OR, 2.31; 95% CI, 0.78-6.82; P = .131). Compared with FEVAR, the OSR group had significantly greater rates of pulmonary complications (19.1% vs 3.7%; OR, 6.19; 95% CI, 2.30-16.67; P < .001) and renal complications (8.1% vs 2.2%; OR, 3.90; 95% CI, 1.06-14.31; P = .040). Conclusions: In the samples assessed in the present study, the results with OSR of JAAAs in the elderly did not differ from those of FEVAR with respect to 30-day mortality despite a greater incidence of pulmonary and renal complications. Although FEVAR should remain the first-line therapy for JAAAs in elderly patients, OSR might be an acceptable alternative for select patients with anatomy unfavorable for FEVAR.
Objectives Widespread adoption of endovascular therapy for the treatment of chronic limb-threatening ischemia has transformed the field of vascular surgery. In this modern era, we aimed to define where open surgical interventions are of greatest benefit for limb salvage. Methods Patients who underwent interventions for chronic limb-threatening ischemia were identified in the vascular-targeted lower extremity National Surgical Quality Improvement Program database for open surgical interventions (OPEN) and endovascular surgical interventions (ENDO) from 2011 to 2017. Patients were further stratified based on the criteria of chronic limb-threatening ischemia (rest pain or tissue loss), and the location of the diseased arteries (femoropopliteal or tibioperoneal). The main outcomes measured included 30-day mortality, amputation, and major adverse cardiovascular events. Results A total of 17,193 patients were revascularized for chronic limb-threatening ischemia: 10,532 were OPEN and 6661 were ENDO. OPEN had higher 30-day mortality, major adverse cardiovascular events, pulmonary, renal dysfunction, and wound complications. However, OPEN resulted in significantly lower 30-day major amputation (3.8% vs. 5.0%, odds ratio (OR): 0.83 [0.72-0.97], P = .018). Subgroup analysis revealed a higher mortality rate in OPEN was observed only in tibioperoneal intervention for tissue loss. Major adverse cardiovascular event was higher in OPEN for most subgroups. OPEN for patients with tissue loss had significantly lower amputation rate than ENDO in both femoropopliteal and tibioperoneal subgroups (3.7% vs. 5.1%, OR: 0.76 [0.59-0.98], P = .036, and 4.7% vs. 6.6%, OR: 0.74 [0.57-0.96], P = .024, respectively). The benefit of open surgery in reducing the amputation rate was not seen in patients with rest pain. Conclusions Open surgical intervention is associated with significantly better limb salvage than endovascular intervention in patients with tissue loss. Surgical options should be given more emphasis as the first-line option in this cohort of patients unless the cardiopulmonary risk is prohibitive.
Temporary cardiac pacemakers used in periods of need during surgical recovery involve percutaneous leads and externalized hardware that carry risks of infection, constrain patient mobility and may damage the heart during lead removal. Here we report a leadless, battery-free, fully implantable cardiac pacemaker for postoperative control of cardiac rate and rhythm that undergoes complete dissolution and clearance by natural biological processes after a defined operating timeframe. We show that these devices provide effective pacing of hearts of various sizes in mouse, rat, rabbit, canine and human cardiac models, with tailored geometries and operation timescales, powered by wireless energy transfer. This approach overcomes key disadvantages of traditional temporary pacing devices and may serve as the basis for the next generation of postoperative temporary pacing technology.
Objective: Open surgical repair (OSR) of abdominal aortic aneurysms (AAAs) has often been reserved in contemporary practice for complex aneurysms requiring a suprarenal or supraceliac proximal clamp level. The present study investigated the associated 30-day outcomes of different proximal clamp levels in OSR of complex infrarenal/juxtarenal AAA in patients with normal renal function and those with chronic renal insufficiency (CRI). Methods: All patients undergoing elective OSR of infrarenal and juxtarenal AAA were identified in the American College of Surgeons National Surgical Quality Improvement Program-targeted AAA database from 2012 to 2018. The patients were stratified into two cohorts (normal renal function [estimated glomerular filtration rate, >= 60 mL/min] and CRI [estimated glomerular filtration rate, <60 mL/min and no dialysis]) before further substratification into groups by the proximal clamp level (infrarenal, inter-renal, suprarenal, and supraceliac). The 30-day outcomes, including mortality, renal and pulmonary complications, and major adverse cardiovascular event rates, were compared within each renal function cohort between proximal clamp level groups using the infrarenal clamp group as the reference. Supraceliac clamping was also compared with suprarenal clamping. Results: A total of 1284 patients with normal renal function and 524 with CRI were included in the present study. The proximal clamp levels for the 1808 patients were infrarenal for 1080 (59.7%), inter-renal for 337 (18.6%), suprarenal for 279 (15.4%), and supraceliac for 112 (6.2%). In the normal renal function cohort, no difference was found in 30-day mortality with any clamp level. Increased 30-day acute renal failure was only observed in the supraceliac vs infrarenal clamp level comparison (5.9% vs 1.5%; adjusted odds ratio [aOR], 3.97; 95% confidence interval [CI], 1.04-5.18; P = .044). In the CRI cohort, supraceliac clamping was associated with an increased rate of renal composite complications (22.7% vs 5.6%; aOR, 8.81; 95% CI, 3.17-24.46; P<.001) and ischemic colitis (13.6% vs 3.0%; aOR, 4.78; 95% CI, 1.38-16.62; P = .014) compared with infrarenal clamping and greater 30-day mortality (13.6% vs 2.4%; aOR, 6.00; 95% CI, 1.14-31.55; P = .034) and renal composite complications (22.7% vs 10.8%; aOR, 2.87; 95% CI, 1.02-8.13; P = .047) compared with suprarenal clamping. Suprarenal clamping was associated with greater renal dysfunction (10.8% vs 5.6%; aOR, 2.77; 95% CI, 1.08-7.13; P = .035) compared with infrarenal clamping, with no differences in mortality. No differences were found in 30-day mortality or morbidity for inter-renal clamping compared with infrarenal clamping in either cohort. No differences were found in major adverse cardiovascular events with higher clamp levels in either cohort. Conclusions: In elective OSR of infrarenal and juxtarenal AAAs for patients with CRI, this study found a heightened mortality risk with supraceliac clamping and increased renal morbidity with suprarenal clamping, though these effects were not present for patients with normal renal function. Every effort should be made to keep the proximal clamp level as low as possible, especially in patients with CRI.
Recent developments in optophysiology techniques such as optogenetics have revolutionized the ability to actuate cell activity. Further combining optophysiology and electrophysiology will integrate the advantages from both optical and electrical modalities and yield enabling technologies that allow simultaneous monitoring of cellular activity in response to modulation, which are crucial for biomedical applications. However, multifunctional devices that can deliver optical stimuli to regions beneath the electrodes and perform simultaneous sensing remain largely unexplored. Existing transparent microelectrode technologies depend on external bulk optical instruments for optical interventions. Here, innovative monolithic integrated multifunctional microsystems are demonstrated by applying transparent nanogrid electrodes onto microscale light sources to permit simultaneous electrophysiology and optical modulation at the same anatomical site. The nanogrid electrodes have transmittances > 70% with a low normalized impedance of 5.9 omega cm(2). Additional features of the devices include superior mechanical flexibility, minimized light-induced electrical artifacts, and excellent biocompatibility. Ex vivo experiments demonstrate that the multifunctional devices can record abnormal heart rhythm in transgenic mouse hearts and simultaneously restore the sinus rhythm via optogenetic pacing. This work provides a versatile approach for constructing multifunctional colocalized biointerfaces containing crosstalk-free optical and electrical modalities with expanded opportunities in both fundamental and applied biomedical research.
OBJECTIVE:Heart disease is still the leading cause of death for both men and women in the United States, and the rate of cardiovascular disease in veterans is even higher than in civilians. This study examines age-related outcomes for veterans undergoing cardiac surgeries at a single institution.METHODS:We included all veterans undergoing coronary artery bypass grafting (CABG) and/or valve surgery between 1997 to 2017 at a single Veterans Affairs (VA) medical center. We stratified this cohort into 4 age groups: ≤59 years old, 60-69 years old, 70-79 years old, and ≥80 years old. Outcomes in age groups were compared using standard statistical methods with the ≤59 years old group as reference.RESULTS:A total of 2,301 patients underwent open cardiac procedures at our institution. The frequency of simultaneous CABG and valve operations increased with age. Usage of cardiopulmonary bypass versus off-pump CABG and operative time was not associated with age. Increased pulmonary and renal complications as well as rates of postoperative arrhythmias all were associated with increasing age. There was no statistically significant difference in 30-day mortality. However, multivariable analysis adjusted for covariates showed all-cause mortality significantly was increased with older age groups (aHR ≥80 years old: 2.94 [2.07-4.17], P < .01; aHR 70-79 years old: 2.15 [1.63-2.83], P < 0.01, with ≤59 years old as reference).CONCLUSIONS:Older patients may have comparable perioperative mortality as their younger counterparts. However, age still is a significant predictor of all-cause mortality, pulmonary and renal complications, and postoperative arrhythmia, and should be considered as a major factor in preoperative risk assessment.