Background—Filter protection after percutaneous coronary intervention (PCI) is now available to prevent distal embolization. The aims of this study were (1) to evaluate the microembolization phenomenon during procedures of stent implantation in native coronary arteries of patients with stable and unstable angina, (2) to assess the amount and characteristics of the debris captured by the Angioguard, and (3) to investigate the relation between clinical and angiographic variables and pathological data. Methods and Results—Elective coronary stenting with the use of a protective filter was attempted in 39 consecutive coronary artery lesions with >60% stenosis (mean, 67.6±8.79%). Debris was present in 75.6% of the filters. Particle size ranged from 47.16 to 2503.48 &mgr;m (mean, 518.83±319.61 &mgr;m) in the major axis. Particles >300 &mgr;m were found in 24 of 28 filters with debris (85.7%), and particles >1000 &mgr;m were present in 10 of 28 filters (35.7%). Patients with unstable angina had greater particles (mean maximum longitudinal diameter, 1098.33±714.3 &mgr;m) than those with stable angina (412.91±453 &mgr;m; P<0.001). The presence of unstable angina (OR, 65; CI, 1.2 to 3420; P=0.03) and age >67 years (OR, 42; CI, 1 to 1698; P=0.04) were found to be the only independent predictors of embolic particle size. Conclusions—By limiting embolization, protective devices may prevent a number of potentially unfavorable events, thereby improving outcome. Our data support the use of these devices, especially in lesions with higher embolic potential, such as those occurring in older patients and in those with unstable angina.
We describe a case of balloon angioplasty of a totally occluded left anterior descending coronary artery through a tortuous left internal mammary artery graft. Because of early recurrence of the lesion, we implanted a short Palmaz-Schatz stent with good angiographic end clinical results. (C) 1996 Wiley-Liss, Inc.
Left ventricular function is a major prognostic factor in patients with mitral regurgitation, but the ability of echocardiographic and hemodynamic parameters to predict the surgical result is controversial. We investigated the prognostic role of various pre-operative indices of left ventricular function in 23 consecutive patients who underwent successful surgical correction of chronic mitral regurgitation. At a mean follow-up of 20 +/- 16 months, patients underwent echocardiography and radio-nuclide angiography and were grouped according to the post-operative left ventricular ejection fraction. Group A was made up of 16 patients with a left ventricular ejection fraction greater than or equal to .45: they showed post-operative reduction of the left ventricular end-diastolic diameter (from 36.3 +/- 3.2 to 30.5 +/- 4.5 mm/m2; p less than .001) and of the radius/thickness ratio (from 3.5 +/- 0.6 to 2.9 +/- 0.6; p less than .01). In 7 patients (group B), post-operative left ventricular ejection fraction was less than .45 and no significant changes in the left ventricular end-diastolic diameter (from 41.5 +/- 2.7 to 36.9 +/- 6.1 mm/m2; NS) or the radius/thickness ratio (from 3.9 +/- 0.9 to 3.4 +/- 1.0; NS) were observed. During the follow-up all group A patients remained asymptomatic or minimally symptomatic, whereas 2 group B patients died of refractory left ventricular failure. Pre-operative left ventricular volumes and diameters, both at end-diastole and end-systole, were significantly greater in group B patients.(ABSTRACT TRUNCATED AT 250 WORDS)
Electrocardiographic repolarization changes and voltage criteria for left ventricular hypertrophy were examined, in relation to hemodynamic, echocardiographic and angiographic data. This was done to evaluate their association with abnormalities in cardiac function and structure in 53 patients with chronic aortic regurgitation and 36 patients with chronic mitral regurgitation. No patient showed evidence of coronary artery disease. Of the patients with aortic regurgitation, the 27 patients with an abnormal repolarization pattern at ECG had worse NYHA functional class when compared to the 24 patients with normal repolarization (2.4 +/- 1 vs 1.6 +/- 0.9; p less than .01). They also had greater left ventricular dimensions (end-diastolic volume: 162 +/- 57 ml/m2 vs 109 +/- 15 ml/m2, p less than .01; end-systolic volume: 85 +/- 46 ml/m2 vs 44 +/- 31 ml/m2, p less than .01), lower left ventricular ejection fraction (.50 +/- .12 vs .63 +/- .14; p less than .01), greater left ventricular mass (170 +/- 56 gr/m2 vs 119 +/- 29 gr/m2; p less than .01) and higher end-diastolic left ventricular pressure (21 +/- 11 mmHg vs 11 +/- 8 mmHg; p less than .01). QRS voltage was less closely related to cardiac function and structure and thus, did not modify the conclusions based on repolarization findings alone. Furthermore, repolarization patterns identified patient subgroups with high or low prevalences of previously described predictors of poor surgical outcome. The presence or absence of the "strain" pattern was not related to differences in cardiac structure and function, in patients with mitral regurgitation.(ABSTRACT TRUNCATED AT 250 WORDS)
The aim of the present investigation was to establish the effects of a single oral dose of isosorbide-5-mononitrate (IS-5-MN) on the hemodynamic parameters and the regional and global left ventricular (LV) function in patients with coronary heart disease.
The severity of aortic valve stenosis should be assessed by means of the calculation of the valvular area; on the other hand, the routine use of the Gorlin's formula for the aortic area is laborious and time consuming. Recently Hakki proposed a simplified formula (area = cardiac output/square root gradient) for the calculation of valvular areas. This method does not require the assessment of the systolic ejection time or the transvalvular flow; furthermore, the peak systolic gradient instead of the mean gradient may be entered into the formula. We have evaluated the reliability of this formula on 83 patients with aortic valve stenosis either pure or with absent to mild aortic incompetence (angiographically first degree maximum). Twenty-eight patients had isolated aortic stenosis, 55 had associated mitral stenosis and/or mitral or tricuspid regurgitation. Our results show a good correlation between the values of valvular areas obtained by Hakki's formula and those obtained by Gorlin's formula (r = 0.90 in the first group and r = 0.91 in the second group of patients). On the contrary we observed a poor relationship between the peak systolic gradient and the valvular area, with a considerable scatter of the data, especially for low values of peak systolic gradient. We therefore conclude that the assessment of the aortic valve stenosis must be based on the estimation of the valvular area; in our hands the Hakki's formula has proven to be easy and sufficiently reliable for routine diagnostic studies.
Segmental wall motion abnormalities of the left ventricle frequently occur in ischemic heart disease. An objective, quantitative method is required to ensure the reproducibility of the assessment of left ventricular regional function, especially in evaluating the changes induced by diagnostic and therapeutic interventions. In 32 normal subjects we obtained 30 degrees right anterior oblique left ventriculograms and developed a method based on the following observations. The method should reflect the symmetric uniform motion of the left ventricular silhouette. Only actual contractile motion should be taken into account; therefore, rotatory and translational motion should be compensated for. Passive systolic movement of aortic and mitral valves accounts for the contraction of neighbouring myocardial segments. Left ventricular wall excursion is most often measured by a coordinate system: since the cavity of the left ventricle becomes relatively longer during systole, left ventricular walls contract neither toward a single central point nor toward the long axis; therefore the appropriate origin of the coordinate system will be a segment. Furthermore, as more elongated left ventricular end-diastolic silhouettes appear to show a greater extent of systolic lengthening (we show evidence of this), the length of the segment must be related to the end-diastolic shape. The basic steps of the method are: 1) identification of a symmetry line, from the aortic mid-point to the apex, by connecting the mid-point of 19 diameters perpendicular to the long axis; 2) roto-translation of the end-systolic silhouette so that the end-systolic apex and aortic mid-point lie on the symmetry line.(ABSTRACT TRUNCATED AT 250 WORDS)
We report the clinical and laboratory findings in a 58 years old woman with corrected transposition of the great arteries (CTGA), who that presented typical angina pectoris. The diagnosis of ischemic heart disease was supported by the history of a previous myocardial infarction. Other findings were a systolic murmur of mild mitral regurgitation, left bundle branch block and enlarged left ventricle on the chest X-ray. Cardiac catheterization showed a corrected transposition of the great arteries (L-malposition with situs solitus); left and right coronary arteries were free of luminal stenosis. We suggest therefore that anginal chest pain may be due to myocardial ischemia induced by discrepancy between myocardial oxygen consumption and coronary blood flow. This complication may occur in patients with corrected transposition of great arteries surviving in adulthood.
Acute aortic dissection is a challenging surgical disease. Replacement of the supracoronary aorta alone can be followed by recurrent aneurysm formation at the level of the residual aortic root. The Bentall procedure prevents this late complication but intraoperative haemorrhage may be severe and valve replacement is always mandatory. A new surgical technique is presented which has been adopted in seven consecutive patients with no deaths. With this procedure, strengthening of the aortic root is obtained by inserting three Dacron Double Velour patches "between" the internal and external aortic lamina, one for each sinus of Valsalva. The patches override the coronary ostia which are left wide patent, and are anchored directly to the aortic anulus by single mattress sutures which reduce the size of the anulus. Suspension of the valve leaflets to the patches overriding each other at the commissures together with anuloplasty reestablish valve continency. The two aortic stumps are secured with running sutures over the free edge and a tubular Dacron graft is then anastomosed to them. The procedure reinforces the aortic root, will prevent recurrent aneurysm formation and avoids at the same time valve replacement, when unnecessary, and coronary arteries reimplantation.