To compare image quality and iodine attenuation intra-individually in portal venous phase photon-counting detector CT (PCD-CT) scans using protocols with different contrast medium (CM) volume. A prospectively acquired patient cohort between 04/2021 and 11/2023 was retrospectively screened if patients had the following combination of portal venous phase thoracoabdominal CT scans: (a) PCD-CT with 120 mL CM volume (PCD-CT120 mL), (b) PCD-CT with 100 mL CM volume (PCD-CT100 mL), and (c) prior energy-integrating detector CT (EID-CT) with 120 mL CM volume. On PCD-CT, virtual monoenergetic image (VMI) reconstructions at 70 keV were applied for both groups as well as additional VMI at 60 keV for PCD‑CT100 mL. Quantitative analyses including signal-to-noise (SNR) and contrast-to-noise ratios (CNR) and qualitative analyses were performed using a mixed linear effects model. The final study cohort comprised 49 patients (mean age 67 [31–86] years, 12 female). Comparison to EID-CT was available in 33 patients. In standard 70 keV VMI reconstructions, PCD-CT100 mL was non-inferior to PCD-CT120 mL as well as to EID-CT120 mL for CNR in abdominal organs (all p > 0.050). The mixed linear effects model revealed significant differences between contrast volume groups for both contrast enhancement and image quality ratings. PCD-CT100 mL/70 keV demonstrated the smallest deviation from optimal contrast enhancement (−0.306, p < 0.001). In portal venous phase thoracoabdominal PCD-CT, a nearly 17
Introduction: The number of incidental renal lesions identified in CT scans of the abdomen is increasing. Objective: The aim of this study was to determine whether hyperdense renal lesions without solid components in a portal venous CT scan can be clearly classified as vascular or non-vascular by material decomposition into iodine and water. Methods: This retrospective single-center study included 26 patients (mean age 72 years ± 9; 16 male) with 42 hyperdense renal lesions (>20 HU) in a contrast-enhanced Photon-Counting Detector CT scan (PCD-CT) between May and December 2022. Spectral decomposition into virtual non-contrast (VNC) images and iodine quantification maps was performed, and HU values were quantified within the lesions. Further imaging and histopathological reports served as reference standards. Results: Mean VNC values were 55.7 (±24.2) HU for non-vascular and 32.2 (±11.1) HU for vascular renal lesions. Mean values in the iodine maps were 5.7 (±7.8) HU for non-vascular and 33.3 (±19.0) HU for vascular renal lesions. Using a threshold of >20.3 HU in iodine maps, a total of 7/8 (87.5%) vascular lesions were correctly identified. Conclusion: This proof-of-principle study suggests that the routine use of spectral information acquired in PCD-CT scans might be able to reduce the necessary workup for hyperdense renal lesions without solid components. Further studies with larger patient cohorts are necessary to validate the results of this study and to determine the usefulness of this method in clinical routine.
Background/Objectives: To evaluate the differences in treatment and outcomes between traumatic and atraumatic splenic lacerations. Methods: This retrospective study included all patients with a diagnosis of splenic lacerations confirmed by computed tomography that presented from 01/2010 to 03/2023 at one tertiary hospital. The exclusion criteria included missing image data and death in the first 24 h due to extensive trauma. The etiology of the splenic laceration, demographic characteristics, and clinical parameters were recorded and evaluated as prognostic factors in therapy success and mortality. Subgroup analyses were undertaken according to the etiology of the splenic laceration and the primary treatment. The extent of splenic laceration was assessed by using the American Association for the Surgery of Trauma (AAST) score in its latest revision (2018). Results: Of all 291 enrolled patients (mean age 47 ± 21 years, 204 males), 50 presented with atraumatic splenic lacerations due to different underlying causes. The occurrence of moderate and high-grade laceration differed significantly between the atraumatic and traumatic study group (45/50 [90%] vs. 139/241 [58%], p < 0.001). Accordingly, the number of patients being treated conservatively differed greatly (20/50 [40%] vs. 164/241 [56%]), with a worse clinical success rate for atraumatic lacerations (75% vs. 94.5%). Atraumatic splenic injuries showed a higher conversion rate to surgery (2/20 [10%] vs. 2/164 [1%]). Despite the lower clinical success rate of splenic artery embolization (SAE) in atraumatic injuries (87% vs. 97%), the number of patients needing treatment for primary SAE in AAST 3 injuries was 14.1 in the traumatic population and only 4 in the atraumatic population. Conclusions: Atraumatic splenic injuries should not be treated as traumatic splenic injuries. An early upgrade to SAE or surgery should be considered for moderate splenic injuries, and they should be evaluated by an interdisciplinary team on a case-by-case basis. However, due to the underlying multimorbidity of patients with atraumatic splenic injuries, a higher mortality is to be expected.
Objectives Aim of this study was to assess the value of virtual non-contrast (VNC) reconstructions in differentiating between adrenal adenomas and metastases on a photon-counting detector CT (PCD-CT). Material and methods Patients with adrenal masses and contrast-enhanced CT scans in portal venous phase were included. Image reconstructions were performed, including conventional VNC (VNC Conv ) and PureCalcium VNC (VNC PC ), as well as virtual monochromatic images (VMI, 40–90 keV) and iodine maps. We analyzed images using semi-automatic segmentation of adrenal lesions and extracted quantitative data. Logistic regression models, non-parametric tests, Bland–Altman plots, and a random forest classifier were used for statistical analyses. Results The final study cohort consisted of 90 patients (36 female, mean age 67.8 years [range 39–87]) with adrenal lesions (45 adenomas, 45 metastases). Compared to metastases, adrenal adenomas showed significantly lower CT-values in VNC Conv and VNC PC ( p = 0.007). Mean difference between VNC and true non-contrast (TNC) was 17.67 for VNC Conv and 14.85 for VNC PC . Random forest classifier and logistic regression models both identified VNC Conv and VNC PC as the best discriminators. When using 26 HU as the threshold in VNC Conv reconstructions, adenomas could be discriminated from metastases with a sensitivity of 86.7% and a specificity of 75.6%. Conclusion VNC algorithms overestimate CT values compared to TNC in the assessment of adrenal lesions. However, they allow a reliable discrimination between adrenal adenomas and metastases and could be used in clinical routine in near future with an increased threshold (e.g., 26 HU). Further (multi-center) studies with larger patient cohorts and standardized protocols are required. Clinical relevance statement VNC reconstructions overestimate CT values compared to TNC. Using a different threshold (e.g., 26 HU compared to the established 10 HU), VNC has a high diagnostic accuracy for the discrimination between adrenal adenomas and metastases. Key Points • Virtual non-contrast reconstructions may be promising tools to differentiate adrenal lesions and might save further diagnostic tests. • The conventional and a new calcium-preserving virtual non-contrast algorithm tend to systematically overestimate CT-values compared to true non-contrast images. • Therefore, increasing the established threshold for true non-contrast images (e.g., 10HU) may help to differentiate between adrenal adenomas and metastases on contrast-enhanced CT.
OBJECTIVE:The aim of this study was to compare the effectiveness of common strategies for artifact reduction of dental material in photon-counting detector computed tomography data sets. MATERIALS AND METHODS:Patients with dental material who underwent clinically indicated CT of the neck were enrolled. Image series were reconstructed using a standard and sharp kernel, with and without iterative metal artifact reduction (IMAR) (Qr40, Qr40 IMAR , Qr60, Qr60 IMAR ) at different virtual monoenergetic imaging (VMI) levels (40-190 keV). On representative slice positions with and without dental artifacts, mean and standard deviation of CT values were measured in all series at identical locations. The mean absolute error of CT values ( ) and the artifact index (AIX) were calculated and analyzed focusing on 3 main comparisons: ( a ) different VMI levels versus 70 keV, ( b ) standard versus sharp kernel, and ( c ) nonuse or use of IMAR reconstruction. The Wilcoxon test was used to assess differences for nonparametric data. RESULTS:The final cohort comprised 50 patients. Artifact measures decreased for VMI levels >70 keV, yet only significantly so for reconstructions using IMAR (maximum reduction, 25%). The higher image noise of the sharp versus standard kernel is reflected in higher AIX values and is more pronounced in IMAR series (maximum increase, 38%). The most profound artifact reduction was observed for IMAR reconstructions (maximum reduction : 84%; AIX: 90%). CONCLUSIONS:Metal artifacts caused by large amounts of dental material can be substantially reduced by IMAR, regardless of kernel choice or VMI settings. Increasing the keV level of VMI series, on the other hand, only slightly reduces dental artifacts; this effect, however, is additive to the benefit conferred by IMAR reconstructions.
Bei soliden Tumoren ist die Detektion lokoregionärer Lymphknoten(LK)-Filiae für die Prognose aber v. a. auch für die Wahl der richtigen Therapie von entscheidender Bedeutung. Dafür stehen verschiedene nichtinvasive Bildgebungsverfahren oder – klassischerweise – die LK-Dissektion zur Verfügung. Die vorliegende Arbeit stellt allgemeine Prinzipien der nichtinvasiven Lymphknotendiagnostik dar und diskutiert den Stellenwert der klinisch verfügbaren Bildgebungsmodalitäten (Ultraschall [US], Computertomographie [CT], Magnetresonanztomographie [MRT], Positronenemissionstomographie [PET]). Zudem werden technische Weiterentwicklungen der einzelnen Modalitäten aufgezeigt. Literaturrecherche und Zusammenfassung der klinischen und wissenschaftlichen Erfahrung der Autoren. Die verfügbaren Bildgebungsverfahren werden unterteilt in (1) morphologische (US, CT, MRT) und (2) funktionelle Modalitäten (PET, spezielle MRT). Erstere erfassen strukturelle LK-Parameter wie Größe und Form, letztere Eigenschaften, die über die Morphologie hinausgehen (z. B. den Glukosestoffwechsel). Die für zukünftige Therapiealgorithmen erforderliche hohe diagnostische Genauigkeit wird eine Kombination beider Aspekte erforderlich machen. Derzeit weist keine der verfügbaren Modalitäten ausreichende Genauigkeit auf, um in allen onkologischen Szenarien die LK-Dissektion zu ersetzen. Eine der großen Herausforderungen an die interdisziplinäre onkologische Forschung ist es, das optimale Zusammenspiel von Bildgebung und LK-Dissektion für die verschiedenen Malignome und Tumorstadien zu definieren.
Purpose: To correlate CT values of the blood pool on VNC series with serum hemoglobin values for the detection of anemia in oncologic patients undergoing contrast-enhanced PCD-CT scans. Methods: This prospective study (NCT04989192) included consecutive oncologic patients undergoing contrastenhanced CT on a novel PCD-CT system between 08/2021 and 01/2022. The interval between complete blood count (CBC) and CT scan acquisition had to be no more than seven days. CT-values of the blood pool were measured on 70 keV VMI series (CT-values(BP)70keV) and on VNC series (CT-values(BP)VNC) at five anatomic positions (left atrium, left ventricle, main pulmonary artery, ascending and descending aorta) and averaged per patient. Pearson correlation analyses and ROC analyses were performed to identify relations between CT-values (BP)VNC, CBC parameters, and degrees of anemia as defined by the WHO (no anemia, mild, moderate, severe anemia). Results: A total of 329 patients (age 68 +/- 12 years; 200 men) were included. CT-values(BP) VNC showed a strong linear correlation to serum hemoglobin (r2 = 0.80, p <.001) and hematocrit (r2 = 0.76, p <.001) and were significantly different between anemia subgroups in both women and men (.HU: 3.5-11.4; all p <.01). ROC analyses yielded high diagnostic performance for the identification of patients without anemia, patients without and with mild anemia, and patients with severe anemia using gender-specific cutoffs for CT-value(BP) VNC (all AUC's > 0.90). Conclusions: The spectral information inherent in PCD-CT acquisitions allows the detection and quantification of anemia in contrast-enhanced CT acquisitions of oncologic patients with high diagnostic accuracy.
Purpose To analyze the conspicuity of pancreatic ductal adenocarcinoma (PDAC) in virtual monoenergetic images (VMI) on a novel photon-counting detector CT (PCD-CT) in comparison to energy-integrating CT (EID-CT). Methods Inclusion criteria comprised initial diagnosis of PDAC (reference standard: histopathological analysis) and standardized contrast-enhanced CT imaging either on an EID-CT or a PCD-CT. Patients were excluded due to different histopathological diagnosis or missing tumor delineation on CT. On the PCD-CT, 40–190 keV VMI reconstructions were generated. Image noise, tumor-to-pancreas ratio (TPR) and contrast-to-noise ratio (CNR) were analyzed by ROI-based measurements in arterial and portal venous contrast phase. Two board-certified radiologist evaluated image quality and tumor delineation at both, EID-CT and PCD-CT (40 and 70 keV). Results Thirty-eight patients (mean age 70.4 years ± 10.3 [range 45–91], 27 males; PCD-CT: n=19, EID-CT: n=19) were retrospectively included. On the PCD-CT, tumor conspicuity (reflected by low TPR and high CNR) was significantly improved at low-energy VMI series (≤ 70 keV compared to > 70 keV), both in arterial and in portal venous contrast phase (P < 0.001), reaching the maximum at 40 keV. Comparison between PCD-CT and EID-CT showed significantly higher CNR on the PCD-CT in portal venous contrast phase at < 70 keV (P < 0.016). On the PCD-CT, tumor conspicuity was improved in portal venous contrast phase compared to arterial contrast phase especially at the lower end of the VMI spectrum (≤ 70 keV). Qualitative analysis revealed that tumor delineation is improved in 40 keV reconstructions compared to 70 keV reconstructions on a PCD-CT. Conclusion PCD-CT VMI reconstructions (≤ 70 keV) showed significantly improved conspicuity of PDAC in quantitative and qualitative analysis in both, arterial and portal venous contrast phase, compared to EID-CT, which may be important for early detection of tumor tissue in clinical routine. Tumor delineation was superior in portal venous contrast phase compared to arterial contrast phase.
Background: In solid tumors, the detection of locoregional lymph node metastases is of decisive importance not only for the prognosis but also for selecting the correct treatment. Various noninvasive imaging methods or, classically, lymph node dissection are available for this purpose.Objective: This article presents the general principles of noninvasive lymph node diagnostics and discusses the value of the clinically available imaging modalities, ultrasound (US), computed tomography (CT), magnetic resonance imaging (MRI) and positron emission tomography (PET). In addition, recent new technical developments of each modality are highlighted.Material and methods: Literature search and summary of the clinical and scientific experience of the authors.Results: The available imaging procedures are divided into (1) morphological (US, CT, MRI) and (2) functional modalities (PET, special MRI). The former capture structural lymph node parameters, such as size and shape, while the latter address properties that go beyond morphology (e.g. glucose metabolism). The high diagnostic accuracy required for future treatment algorithms will require a combination of both aspects.Discussion/conclusion: Currently, none of the available modalities have sufficient accuracy to replace lymph node dissection in all oncological scenarios. One of the major challenges for interdisciplinary oncological research is to define the optimal interaction between imaging and lymph node dissection for different malignancies and tumor stages.
Tibial shaft spiral fractures and fractures of the distal third of the tibia (AO:42A/B/C and 43A) frequently occur with non-displaced posterior malleolus fractures (PM). This study investigated the hypothesis that plain X-ray is not sufficient for a reliable diagnosis of associated non-displaced PM fractures in tibial shaft spiral fractures. 50 X-rays showing 42A/B/C and 43A fractures were evaluated by two groups of physicians, each group was comprised of a resident and a fellowship-trained traumatologist or radiologist. Each group was tasked to make a diagnosis and/or suggest if further imaging was needed. One group was primed with the incidence of PM fractures and asked to explicitly assess the PM. Overall, 9.13/25 (SD ± 5.77) PM fractures were diagnosed on X-ray. If the posterior malleolus fracture was named or a CT was requested, the fracture was considered “detected”. With this in mind, 14.8 ± 5.95 posterior malleolus fractures were detected. Significantly more fractures were diagnosed/detected (14 vs. 4.25/25; p < 0.001/14.8 vs. 10.5/25; p < 0.001) in the group with awareness. However, there were significantly more false positives in the awareness group (2.5 vs. 0.5; p = 0.024). Senior physicians recognized slightly more fractures than residents (residents: 13.0 ± 7.79; senior physicians: 16.5 ± 3.70; p = 0.040). No significant differences were demonstrated between radiologists and trauma surgeons. The inner-rater reliability was high with 91.2
Purpose: To investigate the usefulness of virtual monoenergetic image (VMI) reconstructions derived from scans on a novel photon-counting detector CT (PCD-CT) for artifact reduction in patients after posterior spinal fixation. Methods: This retrospective cohort study included 23 patients status post posterior spinal fixation. Subjects were scanned on a novel PCD-CT (NAEOTOM Alpha, Siemens Healthineers, Erlangen, Germany) as part of routine clinical care. 14 sets of VMI reconstructions were derived in 10 keV increments for the interval 60-190 keV. The mean and the standard deviation (SD) of CT-values in 12 defined locations around a pair of pedicle screws on one vertebral level and the SD of homogenous fat were measured and used to calculate an artifact index (AIx). Results: Averaged over all regions, the lowest AIx was observed at VMI levels of 110 keV (32.5 (27.8-37.9)) which was significantly different from those of VMIs & LE; 90 keV (p < 0.001) or & GE;160 keV (p < 0.015), respectively. Overall AIx values increased in both lower- and higher-keV levels. Regarding individual locations, either a monotonous AIx-decrease for increasing keV values or an AIx-minimum in intermediate-keV levels (100-140 keV) was found. In locations adjacent to larger metal parts, the increase of AIx values at the high-end of the keV spectrum was mainly explained by a reappearance of streak artifacts. Conclusion: Our findings suggest that 110 keV is the optimal VMI setting for overall artifact suppression. In specific anatomical regions, however, slight adjustments towards higher-keV levels may provide better results.
The purpose of this study was to evaluate virtual-non contrast reconstructions of Photon-Counting Detector (PCD) CT-angiography datasets using a novel calcium-preserving algorithm (VNCPC) vs. the standard algorithm (VNCConv) for their potential to replace unenhanced acquisitions (TNC) in patients after endovascular aneurysm repair (EVAR). 20 EVAR patients who had undergone CTA (unenhanced and arterial phase) on a novel PCD-CT were included. VNCConv- and VNCPC-series were derived from CTA-datasets and intraluminal signal and noise compared. Three readers evaluated image quality, contrast removal, and removal of calcifications/stent parts and assessed all VNC-series for their suitability to replace TNC-series. Image noise was higher in VNC- than in TNC-series (18.6 ± 5.3 HU, 16.7 ± 7.1 HU, and 14.9 ± 7.1 HU for VNCConv-, VNCPC-, and TNC-series, p = 0.006). Subjective image quality was substantially higher in VNCPC- than VNCConv-series (4.2 ± 0.9 vs. 2.5 ± 0.6; p < 0.001). Aortic contrast removal was complete in all VNC-series. Unlike in VNCConv-reconstructions, only minuscule parts of stents or calcifications were erroneously subtracted in VNCPC-reconstructions. Readers considered 95% of VNCPC-series fully or mostly suited to replace TNC-series; for VNCConv-reconstructions, however, only 75% were considered mostly (and none fully) suited for TNC-replacement. VNCPC-reconstructions of PCD-CT-angiography datasets have excellent image quality with complete contrast removal and only minimal erroneous subtractions of stent parts/calcifications. They could replace TNC-series in almost all cases.
In dual-energy CT datasets, the conspicuity of liver metastases can be enhanced by virtual monoenergetic imaging (VMI) reconstructions at low keV levels. Our study investigated whether this effect can be reproduced in photon-counting detector CT (PCD-CT) datasets. We analyzed 100 patients with liver metastases who had undergone contrast-enhanced CT of the abdomen on a PCD-CT (n = 50) or energy-integrating detector CT (EID-CT, single-energy mode, n = 50). PCD-VMI-reconstructions were performed at various keV levels. Identical regions of interest were positioned in metastases, normal liver, and other defined locations assessing image noise, tumor-to-liver ratio (TLR), and contrast-to-noise ratio (CNR). Patients were compared inter-individually. Subgroup analyses were performed according to BMI. On the PCD-CT, noise and CNR peaked at the low end of the keV spectrum. In comparison with the EID-CT, PCD-VMI-reconstructions exhibited lower image noise (at 70 keV) but higher CNR (for ≤70 keV), despite similar CTDIs. Comparing high- and low-BMI patients, CTDI-upregulation was more modest for the PCD-CT but still resulted in similar noise levels and preserved CNR, unlike the EID-CT. In conclusion, PCD-CT VMIs in oncologic patients demonstrated reduced image noise–compared to a standard EID-CT–and improved conspicuity of hypovascularized liver metastases at low keV values. Patients with higher BMIs especially benefited from constant image noise and preservation of lesion conspicuity, despite a more moderate upregulation of CTDI.
See also the editorial by Dodd and MacDermott in this issue.
Purpose To address the disagreement about the need for splenic artery embolization (SAE) in medium grade blunt splenic trauma this retrospective study evaluates the clinical outcome of non-operative management (NOM) and the possible impact of a more liberal indication for primary SAE. Method From 01/2010 to 12/2019 186 patients presented with splenic injury on computed tomography (CT) after blunt abdominal trauma. The extent of splenic injuries according to Marmery, vascular pathologies, active bleeding as well as clinical and laboratory parameters were recorded and analyzed with regard to the success rates of NOM and SAE. Procedural complications and clinical outcome were noted. The number needed to treat (NNT) was determined for a possible extension of the indication for SAE to grade 3 injuries. Results Of 186 patients 126 were managed non-operatively, 47 underwent primary SAE and twelve splenectomy. NOM was successful in 119/126 (94 %) patients. Conversion rate was significantly higher in patients with active bleeding or vascular pathology. Patients with failed NOM had a significantly greater decrease in haemoglobin and haematocrit levels. Primary SAE was successful in 45/47 (96 %) cases. Major complications occurred in four cases (9%), all managed without sequela. The NNT in grade 3 splenic injuries equals 13. Conclusions NOM of low to medium-grade blunt splenic trauma has a low failure rate. Presence of active haemorrhage is the most important predictor for failure of NOM. SAE should be reserved for high-grade injuries and visible vascular pathology or active bleeding to avoid a disproportionate increase in the NNT.
Photon-counting detector CT (PCD-CT) promises a leap in spatial resolution due to smaller detector pixel sizes than implemented in energy-integrating detector CTs (EID-CT). Our objective was to compare the visualization of smallest bone details between PCD-CT and EID-CT using a mouse as a specimen. Two euthanized mice were scanned at a 20-slice EID-CT and a dual-source PCD-CT in single-pixel mode at various CTDIVol values. Image noise and signal-to-noise ratio (SNR) were evaluated using repeated ROI measurements. Edge sharpness of bones was compared by the maximal slope within CT value plots along sampling lines intersecting predefined bones of the spine. Two readers evaluated bone detail visualization at four regions of the spine on a three-point Likert scale at various CTDIVol’s. Two radiologists selected the series with better detail visualization among each of 20 SNR-matched pairs of EID-CT and PCD-CT series. In CTDIVol-matched scans, PCD-CT series showed significantly lower image noise (NoiseCTDI=5 mGy: 16.27 ± 1.39 vs. 23.46 ± 0.96 HU, p < 0.01), higher SNR (SNRCTDI=5 mGy: 20.57 ± 1.89 vs. 14.00 ± 0.66, p < 0.01), and higher edge sharpness (Edge Slopelumbar spine: 981 ± 160 vs. 608 ± 146 HU/mm, p < 0.01) than EID-CT series. Two radiologists considered the delineation of bone details as feasible at consistently lower CTDIVol values at PCD-CT than at EID-CT. In comparison of SNR-matched reconstructions, PCD-CT series were still considered superior in almost all cases. In this head-to-head comparison, PCD-CT showed superior objective and subjective image quality characteristics over EID-CT for the delineation of tiniest bone details. Even in SNR-matched pairs (acquired at different CTDIVol’s), PCD-CT was strongly preferred by radiologists. • In dose-matched scans, photon-counting detector CT series showed significantly less image noise, higher signal-to-noise ratio, and higher edge sharpness than energy-integrating detector CT series. • Human observers considered the delineation of tiny bone details as feasible at much lower dose levels in photon-counting detector CT than in energy-integrating detector CT. • In direct comparison of series matched for signal-to-noise ratio, photon-counting detector CT series were considered superior in almost all cases.