INTRODUCTION:Preoperative anatomical assessment is essential to optimize the outcome of individualized cochlear implantation. Algorithms based on cochlear diameters simplify this evaluation. The new version of a surgical planning platform is capable of performing this determination automatically. Our study evaluated the robustness of automated measurements and compared individual differences between automated and manual measurements, including predicting cochlear duct length and insertion angles. MATERIALS AND METHODS:The preoperative cone beam CT scans of 55 MED-EL cochlear implant patients were analyzed. Using the surgical planning platform, the anatomical diameters were measured automatically and manually. The values were compared, as well as the predictions of the insertion angles and prediction of cochlear duct length. RESULTS:The analyses showed good agreement between manual and automatic measurements of cochlear diameters, with the exception of cochlear height, where a significant difference was observed. Some discrepancies were noted for the prediction of the cochlear length duct without, however, a significant impact. Predictions of insertion angles based on automated measurements were comparable to the postoperative evaluations, with no significant difference from the manual ones. DISCUSSION:The robustness of automated assessments is essential for integration into clinical practice. Automated measurements of cochlear dimensions are comparable to manual ones. However, image quality and the presence of anatomical abnormalities may influence the results. In this study, the evaluation of the insertion angle prediction was strengthened by comparison with postoperative results taking into account the actual insertion depth.
During cochlear implant (CI) surgery, it is desirable to perform intraoperative measurements such as Electrocochleography (ECochG) to monitor the inner ear function and thereby to support the preservation of residual hearing. However, a significant challenge arises as the recording location of intracochlear ECochG via the CI electrode changes during electrode insertion. This study aimed to investigate the relationships between intracochlear ECochG recordings, the position of the recording contact within the cochlea relative to its anatomy, and the implications for frequency and residual hearing preservation. Intraoperative ECochG recordings were conducted using the CI electrode (MED-EL) during the insertion of hearing preservation electrodes and after the insertion process. Recordings were continuously conducted using the most apical electrode (contact 1) during insertion. After insertion, the recordings were performed on all different electrode contacts. The electrode location in the cochlea during insertion was estimated using mathematical models and preoperative clinical imaging, while the postoperative electrode position was determined using postoperative clinical imaging. The study involved 10 adult CI recipients. In those with good low-frequency hearing, an increase in signal amplitude was observed, with the highest amplitudes closest to the stimulation frequency generators, and no phase change was observed. Conversely, patients with flat hearing loss exhibited a second peak with an opposite phase in the medial area of the cochlea. This study is the first to suggest that the pattern of the preoperative audiogram may influence the ECochG outcomes measured intraoperatively. Specifically, the ECochG responses during insertion appeared to behave as expected with good low-frequency hearing, while with flat hearing loss there appear to be further effects. These findings indicate that this approach can provide valuable information for the interpretation of intracochlearly recorded ECochG signals.
Objective Preservation of residual hearing is one of the main goals in cochlear implantation. There are many factors that can influence hearing preservation after cochlear implantation. The purpose of the present study was to develop an algorithm for validated preoperative cochlear volume analysis and to elucidate the role of cochlear volume in preservation of residual hearing preservation after atraumatic cochlear implantation. Study design Retrospective analysis. Setting Tertiary referral center. Patients A total of 166 cochlear implant recipients were analyzed. All patients were implanted with either a MED-EL (Innsbruck, Austria) FLEXSOFT (n = 3), FLEX28 (n = 72), FLEX26 (n = 1), FLEX24 (n = 41), FLEX20 (n = 38), or FLEX16 (n = 11, custom made device) electrode array through a round window approach. Main outcome measures: Cochlear volume as assessed after manual segmentation of cochlear cross-sections in cone beam computed tomography, and preservation of residual hearing 6 months after implantation were analyzed. The association between residual hearing preservation and cochlear volume was then assessed statistically. Results Rapid and valid cochlear volume analysis was possible using the individual cross-sections and a newly developed and validated algorithm. Cochlear volume had the tendency to be larger in patients with hearing preservation than in those with hearing loss. Significant correlations with hearing preservation could be observed for the basal width and length of the basal turn. Conclusions Preservation of residual hearing after cochlear implantation may depend on cochlear volume but appears to be influenced more strongly by other cochlear dimensions.
To preserve residual hearing during cochlear implant (CI) surgery it is desirable to use intraoperative monitoring of inner ear function (cochlear monitoring). A promising method is electrocochleography (ECochG). Within this project the relations between intracochlear ECochG recordings, position of the recording contact in the cochlea with respect to anatomy and frequency and preservation of residual hearing were investigated. The aim was to better understand the changes in ECochG signals and whether these are due to the electrode position in the cochlea or to trauma generated during insertion. During and after insertion of hearing preservation electrodes, intraoperative ECochG recordings were performed using the CI electrode (MED-EL). During insertion, the recordings were performed at discrete insertion steps on electrode contact 1. After insertion as well as postoperatively the recordings were performed at different electrode contacts. The electrode location in the cochlea during insertion was estimated by mathematical models using preoperative clinical imaging, the postoperative location was measured using postoperative clinical imaging. The recordings were analyzed from six adult CI recipients. In the four patients with good residual hearing in the low frequencies the signal amplitude rose with largest amplitudes being recorded closest to the generators of the stimulation frequency, while in both cases with severe pantonal hearing losses the amplitude initially rose and then dropped. This might be due to various reasons as discussed in the following. Our results indicate that this approach can provide valuable information for the interpretation of intracochlearly recorded ECochG signals.
OBJECTIVES:Drilling a minimally invasive access to the inner ear is a demanding task in which a computer-assisted surgical system can support the surgeon. Herein, we describe the design of a new micro-stereotactic targeting system dedicated to cochlear implant (CI) surgery and its experimental evaluation in an ex vivo study.METHODS:The proposed system consists of a reusable, bone-anchored reference frame, and a patient-specific drilling jig on top of it. Individualization of the jig is simplified to a single counterbored hole drilled out of a blank. For accurate counterboring, the setup includes a manufacturing device for individual positioning of the blank. The system was tested in a preclinical setting using twelve human cadaver donors. Cone beam computed tomograph (CBCT) scans were obtained and a drilling trajectory was planned pointing towards the basal part of the cochlea. The surgical drill was moved forward manually and slowly while the jig constrained the drill along the predetermined path.RESULTS:Drilling could be performed with preservation of facial nerve in all specimens. The mean error caused by the system at the target point in front of the cochlea was 0.30 mm ± 0.11 mm including an inaccuracy of 0.09 mm ± 0.03 mm for counterboring the guiding aperture into the jig.CONCLUSION:Feasibility of the proposed system to perform a minimally invasive posterior tympanotomy approach was shown successfully in all specimens.SIGNIFICANCE:First evaluation of the new system in a comprehensive ex vivo study demonstrating sufficient accuracy and the feasibility of the whole concept.
Objectives: Test feasibility of a means to distinguish artifact from relevant signal in an experimental method for pre-clinical assessment of bone conduction (BC) stimulation efficiency based on measurement of intracochlear pressure (ICP).Methods: Experiments were performed on fresh-frozen human temporal bones and cadaver heads. In a first step, fiber optic pressure sensors inserted into the cochlea through cochleostomies were intention-ally vibrated to generate relative motion versus the stationary specimen, and the resulting ICP artifact recorded, before and after attaching the sensor fiber to the bone with glue. In a second step, BC stimu-lation was applied in the conventional location for a commercial bone anchored implant, as well as two alternative locations closer to the otic capsule. Again, ICP was recorded and compared with an estimated artifact, calculated from the previous measurements with intentional vibration of the fiber.Results: Intentional vibration of the sensor fiber creates relative motion between fiber and bone, as in-tended, and causes an ICP signal. The stimulus does not create substantial promontory vibration, indicat-ing that the measured ICP is all artifact, i.e. would not occur if the sensor were not in place. Fixating the sensor fiber to the bone with glue reduces the ICP artifact by at least 20 dB. BC stimulation also creates relative motion between sensor fiber and bone, as expected, from which an estimated ICP artifact level can be calculated. The ICP signal measured during BC stimulation is well above the estimated artifact, at least in some specimens and at some frequencies, indicating "real" cochlear stimulation, which would result in an auditory percept in a live subject. Stimulation at the alternative locations closer to the otic capsule appear to result in higher ICP (no statistical analysis performed), indicating a trend towards more efficient stimulation than at the conventional location. Conclusions: Intentional vibration of the fiber optic sensor for measurement of ICP can be used to derive an estimate of the artifact to be expected when measuring ICP during BC stimulation, and to characterize the effectiveness of glues or other means of reducing the artifact caused by relative motion of fiber and bone.(c) 2023 Published by Elsevier B.V.
HypothesisAssessment techniques for the cochlear spatial lateral wall are associated with inter-rater variability, but derived clinical recommendations nonetheless offer value for individualized electrode selection.BackgroundAnatomical variations influence the location of cochlear implant electrodes inside the cochlea. Preoperative planning allows individualization of the electrode based on characterization of the bony lateral wall.MethodsThe study used publicly available digitized temporal bones based on microslicing and computed tomography. Four experienced observers assessed the lateral wall applying manual tracing, linear regression scaling and elliptic-circular approximation methods in all modalities. Radial and height differences were computed in 90-degree steps from the round window center to the apex. Total length, total angular length, and tonotopic frequencies were computed for each reconstruction.ResultsDifferences were found most pronounced between assessment methods in vertical direction across observers and imaging modalities. One of the five anatomies was consistently found to be of shorter cochlear duct length with estimation techniques yielding more conservative results compared with manual tracings.ConclusionsAssessment techniques for the bony lateral wall yield method, observer, and image modality related deviations. Automation of the anatomical characterization may offer potential in minimizing inaccuracies. Nonetheless, observers were consistently able to detect a smaller inner ear demonstrating the ability of current methods to contribute to an optimized choice of electrodes based on individual patient anatomy.
In cochlear implantation, current preoperative planning procedures allow for estimating how far a specific implant will reach into the inner ear of the patient, which is important to optimize hearing preservation and speech perception outcomes. Here we report on the development of a methodology that goes beyond current planning approaches: the proposed model does not only estimate specific outcome parameters but allows for entire, three-dimensional virtual implantations of patient-specific cochlear anatomies with different types of electrode arrays. The model was trained based on imaging datasets of 186 human cochleae, which contained 171 clinical computer tomographies (CTs) of actual cochlear implant patients as well as 15 high-resolution micro-CTs of cadaver cochleae to also reconstruct the refined intracochlear structures not visible in clinical imaging. The model was validated on an independent dataset of 141 preoperative and postoperative clinical CTs of cochlear implant recipients and outperformed all currently available planning approaches, not only in terms of accuracy but also regarding the amount of information that is available prior to the actual implantation.
Einleitung Die individualisierte Cochlea-Implantation, das heißt eine patientenspezifische Wahl der Elektrodenlänge und Modalität (elektrisch-akustische Stimulation (EAS) oder rein-elektrische Stimulation (ES)) hat das Ziel die bestmögliche Versorgung für jeden Patienten zu erreichen.
OBJECTIVES:Temporal bone fracture can cause posttraumatic deafness. Sequelae like ossification or obliteration of the cochlea can impact the outcome of cochlear implantation. This study highlights the effect of localisation of the fracture to morphologic, electric and functional criteria.METHODS:The study group consists of patients suffering from hearing loss caused by temporal bone fracture (n = 61 ears). Patients were divided into otic capsule sparing (OCS) and otic capsule involving (OCI) fractures. The OCI group was additionally divided into subgroups with or without signs of ossification inside the cochlea. Postoperative imaging, hearing tests and electrode impedances were analysed.RESULTS:The results of postoperative hearing rehabilitation showed lower speech understanding scores for the OCI group, especially for the ossification group. OCI fractures with signs of ossification showed increased impedances. Patients in the OCI group suffered more frequently from facial nerve stimulation (FNS). FNS was most frequently observed within the ossification group.CONCLUSION:Cochlear implantation in patients with temporal bone fracture is adequate therapy for the treatment of fracture-induced deafness. In long-term observation, these patients show comparable results with regular cochlear implant (CI) patients. Implantation should be performed as soon as possible after hearing loss, before obstructing obliteration or ossification of the cochlea start.
Objectives The goal was to investigate the relationship between the insertion angle/cochlear coverage of cochlear implant electrode arrays and post-operative speech recognition scores in a large cohort of patients implanted with lateral wall electrode arrays. Methods Pre- and post-operative cone beam computed tomography scans of 154 ears implanted with lateral wall electrode arrays were evaluated. Traces of lateral wall and electrode arrays were combined into a virtual reconstruction of the implanted cochlea. This reconstruction was used to measure insertion angles and proportional cochlear coverage. Word recognition scores and sentence recognition scores measured 12 months after implantation using electric-only stimulation were used to examine the relationship between cochlear coverage/insertion angle and implantation outcomes. Results Post-operative word recognition scores and the difference between post- and pre-operative word recognition scores were positively correlated with both cochlear coverage and insertion angle, however sentence recognition scores were not. A group-wise comparison of word recognition scores revealed that patients with cochlear coverage below 70% performed significantly worse than patients with coverage between 79%-82% (p = 0.003). Performance of patients with coverage above 82% was on average poorer than between 79%-82, although this finding was not statistically significant (p = 0.84). Dividing the cohort into groups based on insertion angle quadrants revealed that word recognition scores were highest above 450° insertion angle, sentence recognition scores were highest between 450° and 630° and the difference between pre- and post-operative word recognition scores was largest between 540° and 630°, however none of these differences reached statistical significance. Conclusions The results of this study show that cochlear coverage has an effect on post-operative word recognition abilities and the benefit patients receive from their implant. Generally, higher coverage led to better outcomes, however there were results indicating that insertion past 82% cochlear coverage may not provide an additional benefit for word recognition. These findings can be useful for choosing the optimal electrode array and thereby improving cochlear implantation outcomes on a patient-individual basis.
Anatomical malformations, obliterations of the cochlea, or re-implantations pose particular challenges in cochlear implantation. Treatment methods rely on radiological and intraoperative findings and include incomplete insertion, the implantation of a double array, and radical cochleostomy. In addition, a stiff electrode array, e.g., the IE stiff (IES) custom-made device (CMD, MED-EL), was prescribed individually for those special cases and pre-inserted prior to facilitate cochlear implantation in challenging cases. Data on outcomes after implantation in obliterated cochleae are usually based on individual case reports since standardised procedures are lacking. A retrospective analysis was conducted to analyse our cases on obliterated cochleae treated with MED-EL devices in order to allow the different cases to be compared. Impedances and speech perception data of patients treated with the IES CMD and the double array were retrospectively compared to patients treated with a STANDARD or FLEX electrode array (the REGULAR group). Patients with a Split-Array CMD had a poor speech perception when compared to patients treated with the IES CMD device. Thus, the IES CMD can successfully be used in patients with obliterated cochleae who would otherwise be non-users, candidates for a Split-Array CMD, or candidates for partial insertion with insufficient cochlear coverage.
The human cochlea has a highly individual microanatomy. Cochlear implantation therefore requires an evaluation of the individual cochlear anatomy to reduce surgical risk of implantation trauma. However, in-vivo cochlear imaging is limited in resolution. To overcome this issue, cochlear models based on exact anatomical data have been developed. These models can be fitted to the limited parameters available from clinical imaging to provide a prediction of the precise cochlear microanatomy. Recently, models have become available with improved precision that additionally allow predicting the 3D form of an individual cochlea. The present study has further improved the precision of modelling by incorporating microscopic details of a large set of 108 human cochleae from corrosion casts. The new model provides a more flexible geometric shape that can better predict local variations like vertical dips and jumps and provides an approximation of frequency allocation in the cochlea. The outcome of this and five other models have been quantified (validated) on an independent set of 20 µCTs of human cochleae. The new model outperformed previous models and is freely available for download and use.
HYPOTHESIS:Various studies over the last few decades have shown that the cochlea is not a uniform structure, but that its size and shape may vary quite substantially in between subjects. The surgical planning platform enables the user to quickly approximate the size of a cochlea within clinical imaging data by measuring the basal cochlear diameters A and B. It also allows for contact specific insertion angle predictions for MED-EL cochlear implant electrode arrays based on this individual anatomy approximation. The proposed, retrospective study was performed to evaluate the accuracy of these predictions.METHODS:Preoperative CBCT scans of N = 91 MED-EL cochlear implant patients with different types of FLEX electrode arrays (flexible, thin, and straight arrays) were evaluated using a planning module. Both the initial version (based on an equation proposed by Escudé et al.) as well as a novel, recently proposed approach (called elliptic-circular approximation) was employed. All predictions were then compared to the actual insertion angles which were derived from postoperative CBCT images of the same patient.RESULTS:Most prediction deviations of the investigated cases stayed below 45deg for all electrode arrays and both prediction methods. In general, prediction deviations increased from base to apex were found to be larger for longer electrode arrays. Hardly any significant differences between the two prediction methods were observed. However, particularly large deviations were found for the Escudé method and could be substantially deceased with the updated elliptic-circular approximation approach.CONCLUSIONS:The new platform version with its updated prediction module allows to reliably predict insertion angles even for cochlear anatomies with slightly unusual features and shapes.
Objectives: (1) To assess variations of the human intracochlear anatomy and quantify factors which might be relevant for cochlear implantation (CI) regarding surgical technique and electrode design. (2) Search for correlations of these factors with clinically assessable measurements. Design: Human temporal bone study with micro computed tomography (μCT) data and analysis of intracochlear geometrical variations: μCT data of 15 fresh human temporal bones was generated, and the intracochlear lumina scala tympani (ST) and scala vestibuli were manually segmented using custom software specifically designed for accurate cochlear segmentation. The corresponding datasets were processed yielding 15 detailed, three-dimensional cochlear models which were investigated in terms of the scalae height, cross-sectional size, and rotation as well as the interrelation of these factors and correlations to others. Results: The greatest anatomical variability was observed within the round window region of the cochlea (basal 45°), especially regarding the cross-sectional size of the ST and its orientation relative to the scala vestibuli, which were found to be correlated (p < 0.001). The cross-sectional height of the ST changes substantially for both increasing cochlear angles and lateral wall distances. Even small cochleae were found to contain enough space for all commercially available CI arrays. Significant correlations of individual intracochlear parameters to clinically assessable ones were found despite the small sample size. Conclusion: While there is generally enough space within the ST for CI, strong intracochlear anatomical variations could be observed highlighting the relevance of both soft surgical technique as well as a highly flexible and self-adapting cochlear implant electrode array design. Cochlear dimensions (especially at the round window) could potentially be used to indicate surgically challenging anatomies.
Introduction: This study aims to investigate the performance of an active middle ear implant actuator for various coupling configurations. Actuator output and conductive losses were measured, and the stability of coupling was evaluated by challenging the link between actuator and ossicles through pressure events in magnitudes that occur in daily life. Methods: Actuator coupling efficiency and the occurrence of conductive losses were measured in 10 temporal bones through laser Doppler vibrometry on the stapes footplate for various coupling types (incus short process with and without laser hole, incus long process, stapes head). To test the stability of coupling, actuator output was measured before and after daily-life pressure events that were simulated; Valsalva maneuvers (500 cycles of -40 to +60 hPa) and jumping into a swimming pool and diving 3 m deep (a step change of 300 hPa). Results: Actuator output was similarly high for all types of coupling to the incus (short process and long process) and most efficient for coupling to the stapes head. Conductive losses occurred in two temporal bones (TBs) for short process coupling but for seven TBs for coupling to the incus long process. All coupling types were stable and did not lose efficiency after pressure events in the low-frequency range (<1 kHz). Losses in output of 13 to 24 dB were observed in one TB at frequencies from 3 to 6 kHz. Conclusion: Actuator output was similarly high for all types of coupling to the incus but coupling to the incus long process led to a higher occurrence of conductive losses. All three coupling configurations connected the actuator securely to the ossicular chain, under variations of barometric pressure that can be expected in daily life.
Entzündungen im Kopf-Hals-Bereich können sich diffus-phlegmonös in die Umgebung ausbreiten oder Ursache für ausgedehnte Abszedierungen sein. Im Falle von sich rasch ausbreitenden Weichteilnekrosen, die häufig Kutis, Bindegewebe oder Muskulatur betreffen, spricht man von einer nekrotisierenden Fasziitis. Sie zählt zu den schwersten Formen zervikaler Weichgewebsinfektionen (Anaya DA, Delleinger EP. Clin Infect Dis 2006; 44: 705–710). In der Mehrheit der Fälle gehen diese Entzündungen von den Zähnen oder von den Gaumenmandeln aus. Streptokokken und/oder Anaerobier lassen sich am häufigsten isolieren, wobei sie zum Teil besondere Virulenzfaktoren aufweisen (Ramachandran. Virulence 2014; 5: 213–218. doi:10.416/viru.27 024). Durch Übergang in eine Sepsis oder in eine Mediastinitis resultieren zum Teil fulminante Verläufe, die auch heute noch eine Letalität von über 50 % aufweisen (Gunaratne et al. Head Neck 2018; 40: 2094–2102; Velhonoja et al. Eur Arch Otorhinolaryngol 2020; 277: 863–872; Almuqamam et al. StatPearls [Internet], Stat Pearls Publishing: letztes update 25.08.2020).
Purpose To evaluate temporal bone cone-beam CT in patients with idiopathic sudden sensorineural hearing loss (ISSNHL) being treated with primary and secondary intratympanic (IT) triamcinolone and to possibly correlate these results to the clinical outcome. Methods Retrospective analysis of patients treated with IT triamcinolone for ISSNHL at our department in 2018. Pre- and post-therapeutic audiologic examinations included four-tone average (FTA) at 0.5, 1, 2 and 3 kHz. Using a clinical questionnaire, pre-therapeutic CBCT scans were re-evaluated looking at items, which might interfere with adequate drug diffusion into the inner ear (e.g. bony overhangs or secondary membranes at the round or oval window). Results Thirty-one patients were included. Twenty-four (77%; group A) had experienced ineffective systemic steroid therapy before and seven (23%; group B) received primary IT injections. Four group A-patients (21%) and two group B-patients (33%) showed a post-therapeutic FTA improvement of more than 15 dB HL. Bony overhangs at the round window niche (RWN) were present in seven cases (26%), a secondary membrane at the RWN in four (15%) and soft tissue in eight (30%) cases, respectively. Conclusion Most patients present radiological findings in CBCT imaging, which might interfere with drug diffusion through the RW membrane. Interestingly, soft or bony tissue obstructing the RWN or the OWN was found in 50% of patients, who showed improvement of hearing. We conclude that radiologic 'tiny' findings are either clinically irrelevant or improvement in hearing is independent from intratympanic drug delivery.
•A patient was implanted with a Vibrant Soundbridge and a Cochlear Implant in the same ear.•Residual hearing and speech perception were monitored for 1 year after surgery.•Postoperative residual hearing is stable, speech perception is satisfactory.•The feasibility of this concept for simultaneous electro-acoustic stimulation could be proven.