Nickel oxide (NiO) nanoparticles from several manufacturers with different reported sizes and surface coatings were characterized prior to assessing their cellular toxicity. The physical characterization of these particles revealed that sizes often varied from those reported by the supplier, and that particles were heavily agglomerated when dispersed in water, resulting in a smaller surface area and larger hydrodynamic diameter upon dispersion. Cytotoxicity testing of these materials showed differences between samples; however, correlation of these differences with the physical properties of the materials was not conclusive. Generally, particles with higher surface area and smaller hydrodynamic diameter were more cytotoxic. While all samples produced an increase in reactive oxygen species (ROS), there was no correlation between the magnitude of the increase in ROS and the difference in cytotoxicity between different materials.
Cerium oxide nanoparticles are promising materials as novel nanoscale therapeutics and are commonly used materials in industrial processes. Most cytotoxicity studies on cerium oxide nanoparticles are made from in-lab prepared materials making comparison between studies challenging, especially when performed on unique cell lines under non-standard conditions. Using commercially available nanoparticles we show that particle stability/agglomeration may be critical in determining the cytotoxicity in some cell lines, while in other cell lines, larger sized primary particles are linked to higher cytotoxicity, contrasting what has been reported in the literature for smaller cerium nanoparticles. To accelerate the development of cerium oxide enabled commercial processes and biomedical innovations, a clearer understanding of the interactions between cerium oxide nanoparticles and cells is needed to better understand their fate in and impact on biological systems.
Particle size measurements of cellulose nanocrystals (CNCs) are challenging due to their broad size distribution, irregular shape and propensity to agglomerate. Particle size is one of the key parameters that must be measured for quality control purposes and to differentiate materials with different properties. We report the results of an interlaboratory comparison (ILC) which examined atomic force microscopy (AFM) data acquisition and data analysis protocols. Samples of CNCs deposited on poly-L-lysine coated mica were prepared in the pilot laboratory and sent to 10 participating laboratories including academic, government and industrial organizations with varying levels of experience with imaging CNCs. The participant data sets indicated that the central location, width and asymmetry varied considerably for both length and height distributions. To deal with this variability we used a skew normal distribution to model the data from each laboratory and to obtain the consensus distribution that describes the CNC particle size. The skew normal distribution has 3 parameters: a central location (mean), distribution width (standard deviation) and asymmetry (shape) factor. This approach gave consensus distributions with mean, standard deviation and asymmetry factor of 94.9 nm, 37.3 nm and 6.0 for length and 3.4 nm, 1.2 nm and 2.8 for height, respectively. The use of multiple probes and/or deterioration of the probe with increased use are significant contributing factors to the variability in mean length between laboratories. There is less variability in height across participating laboratories and tests of applied imaging force indicate that it is possible to image without significant compression of the CNCs. The number of CNCs necessary to obtain a reliable data set depends on the probes and operating conditions, but with careful control of various parameters analysis of 250 and 300 CNCs should provide consistent data sets for height and length, respectively for one sample. Comparison of AFM with transmission electron microscopy (TEM) data obtained in the same ILC demonstrated excellent agreement between measured lengths for the 2 methods. By contrast AFM height was approximately one half the TEM width, a result that indicates the presence of a significant number of laterally agglomerated particles, consistent with literature data.
Physical chemical characterization of nanomaterials is critical to assessing quality control during production, evaluating the impact of material properties on human health and the environment, and developing regulatory frameworks for their use. We have investigated a set of 29 nanomaterials from four metal oxide families (aluminum, copper, titanium and zinc) with a focus on the measurands that are important for the basic characterization of dry nanomaterials and the determination of the dose metrics for nanotoxicology. These include crystalline phase and crystallite size, measured by powder X-ray diffraction, particle shape and size distributions from transmission electron microscopy, and specific surface area, measured by gas adsorption. The results are compared to the nominal data provided by the manufacturer, where available. While the crystalline phase data are generally reliable, data on minor components that may impact toxicity is often lacking. The crystal and particle size data highlight the issues in obtaining size measurements of materials with broad size distributions and significant levels of aggregation, and indicate that reliance on nominal values provided by the manufacturer is frequently inadequate for toxicological studies aimed at identifying differences between nanoforms. The data will be used for the development of models and strategies for grouping and read-across to support regulatory human health and environmental assessments of metal oxide nanomaterials.
Particle size is a key parameter that must be measured to ensure reproducible production of cellulose nanocrystals (CNCs) and to achieve reliable performance metrics for specific CNC applications. Nevertheless, size measurements for CNCs are challenging due to their broad size distribution, irregular rod-shaped particles, and propensity to aggregate and agglomerate. We report an interlaboratory comparison (ILC) that tests transmission electron microscopy (TEM) protocols for image acquisition and analysis. Samples of CNCs were prepared on TEM grids in a single laboratory, and detailed data acquisition and analysis protocols were provided to participants. CNCs were imaged and the size of individual particles was analyzed in 10 participating laboratories that represent a cross section of academic, industrial, and government laboratories with varying levels of experience with imaging CNCs. The data for each laboratory were fit to a skew normal distribution that accommodates the variability in central location and distribution width and asymmetries for the various datasets. Consensus values were obtained by modeling the variation between laboratories using a skew normal distribution. This approach gave consensus distributions with values for mean, standard deviation, and shape factor of 95.8, 38.2, and 6.3 nm for length and 7.7, 2.2, and 2.9 nm for width, respectively. Comparison of the degree of overlap between distributions for individual laboratories indicates that differences in imaging resolution contribute to the variation in measured widths. We conclude that the selection of individual CNCs for analysis and the variability in CNC agglomeration and staining are the main factors that lead to variations in measured length and width between laboratories.