Introduction: Managing chronic osteomyelitis can be challenging and attention to the osseous dead-space left following resection is an important part of successful treatment. We assess radiographic bone healing following implantation of a gentamicin-eluting synthetic bone graft substitute (gBGS) used at chronic osteomyelitis (cOM) resection. We also describe histological carrier changes from biopsies in nine cases at various time points. Methods: This was a retrospective review of a prospectively collected consecutive series of 163 patients with Cierny-Mader Type III or IV cOM who underwent single-stage excision, insertion of gBGS and definitive soft-tissue closure or coverage. Bone defect filling was assessed radiographically using serial radiographs. Nine patients had subsequent surgery, not related to infection recurrence, allowing opportunistic biopsy between 19 days and two years after implantation. Results: Infection was eradicated in 95.7% with a single procedure. 138 patients had adequate radiographs for assessment with minimum one-year follow-up (mean 1.7 years, range 1.0-4.7 years). Mean void-filling at final follow-up was 73.8%. There was significantly higher void-filling in metaphyseal compared to diaphyseal voids (mean 79.0% versus 65.6%; p=0.017) and in cases with good initial interdigitation of the carrier (mean 77.3% versus 68.7%; p=0.021). Bone formation continued for more than two years in almost two-thirds of patients studied (24/38; 63.2%). Histology revealed active biomaterial remodelling. It was osteoconductive with osteoblast recruitment, leading to the formation of osteoid, then woven and lamellar bone on the substrate's surface. Immunohistochemistry demonstrated osteocyte specific markers, dentine matrix protein-1 and podoplanin within the newly formed bone. Conclusion: This antibiotic-loaded biomaterial is effective in managing dead-space in surgically treated cOM with a low infection recurrence rate (4.3%) and good mean bone void-filling (73.8%). The radiographic resolution of the bone defect is associated with bone formation, as supported by histological analysis.
Assessment of bone graft material efficacy is difficult in humans, since invasive methods like staged CT scans or biopsies are ethically unjustifiable. Therefore, we developed a novel large animal model for the verification of a potential transformation of synthetic bone graft substitutes into vital bone. The model combines multiple imaging methods with corresponding histology in standardized critical sized cancellous bone defect. Cylindrical bone voids (10 ml) were created in the medial femoral condyles of both hind legs (first surgery at right hind leg, second surgery 3 months later at left hind leg) in three merino‐wool sheep and either (i) left empty, filled with (ii) cancellous allograft bone or (iii) a synthetic, gentamicin eluting bone graft substitute. All samples were analysed with radiographs, MRI , μ CT , DEXA and histology after sacrifice at 6 months. Unfilled defects only showed ingrowth of fibrous tissue, whereas good integration of the cancellous graft was seen in the allograft group. The bone graft substitute showed centripetal biodegradation and new trabecular bone formation in the periphery of the void as early as 3 months. μ CT gave excellent insight into the structural changes within the defects, particularly progressive allograft incorporation and the bone graft substitute biodegradation process. MRI completed the picture by clearly visualizing soft tissue ingrowth into unfilled bone voids and presence of fluid collections. Histology was essential for verification of trabecular bone and osteoid formation. Conventional radiographs and DEXA could not differentiate details of the ongoing transformation process. This model appears well suited for detailed in vivo and ex vivo evaluation of bone graft substitute behaviour within large bone defects.
Implant-related infections like periprosthetic joint infections (PJI) are still a challenging issue in orthopedic surgery. In this study, we present a prophylactic anti-infective approach based on a local delivery of the antibiotic gentamicin. The local delivery is achieved via a nanoscale polyelectrolyte multilayer (PEM) coating that leaves the bulk material properties of the implant unaffected while tuning the surface properties. The main components of the coating, i.e. polypeptides and sulfated glycosaminoglycans (sGAG) render this coating both biomimetic (matrix mimetic) and biodegradable. We show how adaptions in the conditions of the multilayer assembly process and the antibiotic loading process affect the amount of delivered gentamicin. The highest concentration of gentamicin could be loaded into films composed of polypeptide poly-glutamic acid when the pH of the loading solution was acidic. The concentration of gentamicin on the surface could be tailored with the number of deposited PEM layers. The resulting coatings reveal a bacteriotoxic effect on Staphylococcus cells but show no signs of cytotoxic effects on MC3T3-E1 osteoblasts. Moreover, when multilayer-coated titanium rods were implanted into contaminated medullae of rat tibiae, a reduction in the development of implant-related osteomyelitis was observed. This reduction was more pronounced for the multifunctional, matrix-mimetic heparin-based coatings that only deliver lower amounts of gentamicin.
Coating of plasma chemical oxidized titanium (TiOB®) with gentamicin-tannic acid (TiOB® gta) has proven to be efficient in preventing bacterial colonization of implants. However, in times of increasing antibiotic resistance, the development of alternative antimicrobial functionalization strategies is of major interest. Therefore, the aim of the present study is to evaluate the antibacterial and biocompatible properties of TiOB® functionalized with silver nanoparticles (TiOB® SiOx Ag) and ionic zinc (TiOB® Zn). Antibacterial efficiency was determined by agar diffusion and proliferation test on Staphylocuccus aureus. Cytocompatibility was analyzed by direct cultivation of MC3T3-E1 cells on top of the functionalized surfaces for 2 and 4 d. All functionalized surfaces showed significant bactericidal effects expressed by extended lag phases (TiOB® gta for 5 h, TiOB® SiOx Ag for 8 h, TiOB® Zn for 10 h). While TiOB® gta (positive control) and TiOB® Zn remained bactericidal for 48 h, TiOB® SiOx Ag was active for only 4 h. After direct cultivation for 4 d, viable MC3T3-E1 cells were found on all surfaces tested with the highest biocompatibility recorded for TiOB® SiOx Ag. The present study revealed that functionalization of TiOB® with ionic zinc shows bactericidal properties that are comparable to those of a gentamicin-containing coating.
Assessment of bone graft material efficacy is difficult in humans, since invasive methods like staged CT scans or biopsies are ethically unjustifiable. Therefore, we developed a novel large animal model for the verification of a potential transformation of synthetic bone graft substitutes into vital bone. The model combines multiple imaging methods with corresponding histology in standardized critical sized cancellous bone defect. Cylindrical bone voids (10 ml) were created in the medial femoral condyles of both hind legs (first surgery at right hind leg, second surgery 3 months later at left hind leg) in three merino-wool sheep and either (i) left empty, filled with (ii) cancellous allograft bone or (iii) a synthetic, gentamicin eluting bone graft substitute. All samples were analysed with radiographs, MRI, μCT, DEXA and histology after sacrifice at 6 months. Unfilled defects only showed ingrowth of fibrous tissue, whereas good integration of the cancellous graft was seen in the allograft group. The bone graft substitute showed centripetal biodegradation and new trabecular bone formation in the periphery of the void as early as 3 months. μCT gave excellent insight into the structural changes within the defects, particularly progressive allograft incorporation and the bone graft substitute biodegradation process. MRI completed the picture by clearly visualizing soft tissue ingrowth into unfilled bone voids and presence of fluid collections. Histology was essential for verification of trabecular bone and osteoid formation. Conventional radiographs and DEXA could not differentiate details of the ongoing transformation process. This model appears well suited for detailed in vivo and ex vivo evaluation of bone graft substitute behaviour within large bone defects.
AimA gentamicin-eluting biocomposite consisting of hydroxyapatite and calcium sulfate1 can provide effective dead space management in chronic osteomyelitis. However, radiographic follow-up after implantation of this novel material has consistently shown evidence of several unique imaging features previously not described with other comparable bone graft substitutes. Conclusive interpretation of these newly described imaging features is difficult as long term follow-up and histological correlation is not yet available. The aim of this study was to establish a large animal model, closely simulating the clinical situation in order to permit further analysis of imaging features in correlation with histological progression of bone remodelling.MethodStandardised bone defects were created in ten Merino-wool sheep (age: two to four years). Large drill holes (diameter 2.5cm, depth 2cm, volume approx. 10ml) were placed in the medial femoral condyles of both hind legs and filled with a gentamicin antibiotic eluting ...
AimThis study describes and correlates the radiographic and histologic changes which develop in a Gentamicin-eluting synthetic bone graft substitute* in the management of bone defects after resecti...
Local release of antibiotic has advantages in the treatment of chronic osteomyelitis and infected fractures. The adequacy of surgical debridement is still key to successful clearance of infection but local antibiotic carriers seem to afford greater success rates by targeting the residual organisms present after debridement and delivering much higher local antibiotic concentrations compared with systemic antibiotics alone. Biodegradable ceramic carriers can be used to fill osseous defects, which reduces the dead space and provides the potential for subsequent repair of the osseous defect as they dissolve away. A dissolving ceramic antibiotic carrier also raises the possibility of single stage surgery with definitive closure and avoids the need for subsequent surgery for spacer removal.In this article we provide an overview of the properties of various biodegradable ceramics, including calcium sulphate, the calcium orthophosphate ceramics, calcium phosphate cement and polyphasic carriers. We summarise the antibiotic elution properties as investigated in previous animal studies as well as the clinical outcomes from clinical research investigating their use in the surgical management of chronic osteomyelitis.Calcium sulphate pellets have been shown to be effective in treating local infection, although newer polyphasic carriers may support greater osseous repair and reduce the risk of further fracture or the need for secondary reconstructive surgery. The use of ceramic biocomposites to deliver antibiotics together with BMPs, bisphosphonates, growth factors or living cells is under investigation and merits further study.We propose a treatment protocol, based on the Cierny-Mader classification, to help guide the appropriate selection of a suitable ceramic antibiotic carrier in the surgical treatment of chronic osteomyelitis.
Bone histology of decalcified or undecalcified samples depends on the investigation. However, in research each method provides different information to answer the scientific question. Decalcification is the first step after sample fixation and governs what analysis is later feasible on the sections. Besides, decalcification is favored for immunostaining and in situ hybridization. Otherwise, sample decalcification can be damaging to bone biomaterials implants that contains calcium or strontium. On the other hand, after decalcification mineralization cannot be assessed using histology or imaging mass spectrometry. The current study provides a solution to the hardship caused by material presence within the bone tissue. The protocol presents a possibility of gaining sequential and alternating decalcified and undecalcified sections from the same bone sample. In this manner, investigations using histology, protein signaling, in situ hybridization, and mass spectrometry on the same sample can better answer the intended research question. Indeed, decalcification of sections and grindings resulted in well-preserved sample and biomaterials integrity. Immunostaining was comparable to that of classically decalcified samples. The study offers a novel approach that incites correlative analysis on the same sample and reduces the number of processed samples whether clinical biopsies or experimental animals.
Different treatment strategies are available for bone, joint and soft tissue infections, including use of local antibiotics; negative pressure wound therapy; one-stage, two-stage or multi-stage revisions; or open wound therapy. All methods have one principle in common: adequate surgical debridement is the prerequisite for successful treatment of bone, joint and soft tissue infections. According to the different textures of healthy, infected or necrotic tissue, special techniques are used. In this article we will describe the clinical presentation of necrotic and non-vital tissue in skin, soft tissue and bone and appropriate techniques of debridement.
The surface properties of titanium alloy implants for improved osseointegration in orthopaedic and dental surgery have been modified by many technologies. Hydroxyapatite coatings with a facultative integration of growth factors deposited by plasma spraying showed improved osseointegration. Our approach in order to enhance osseointegration was carried out by a surface modification method of titanium alloy implants called plasma chemical oxidation (PCO). PCO is an electrochemical procedure that converts the nm-thin natural occurring titanium-oxide layer on an implant to a 5 mu m thick ceramic coating (TiOB-surface). Bioactive TiOB-surfaces have a porous microstructure and were loaded with calcium and phosphorous, while bioinert TiOB-surfaces with less calcium and phosphorous loadings are smooth. A rat tibial model with bilateral placement of titanium alloy implants was employed to analyze the bone response to TiOB-surfaces in vivo. 64 rats were randomly assigned to four groups of implants: (i) pure titanium alloy (control), ii) titanium alloy, type III anodization, (iii) bioinert TiOB-surface, and (iv) bioactive TiOB-surface. Mechanical fixation was evaluated by pull out tests at 3 and 8 weeks.The bioactive TiOB-surface showed significantly increased shear strength at 8 weeks compared to all other groups.
Advances have been achieved in the design and biomechanical performance of orthopedic implants in the last decades. These include anatomically shaped and angle-stable implants for fracture fixation or improved biomaterials (e.g. ultra-high-molecular-weight polyethylene) in total joint arthroplasty. Future modifications need to address the biological function of implant surfaces. Functionalized surfaces can promote or reduce osseointegration, avoid implant-related infections or reduce osteoporotic bone loss. To this end, polyelectrolyte multilayer structures have been developed as functional coatings and intensively tested in vitro previously. Nevertheless, only a few studies address the effect of polyelectrolyte multilayer coatings of biomaterials in vivo. The aim of the present work is to evaluate the effect of polyelectrolyte coatings of titanium alloy implants on implant anchorage in an animal model. We test the hypotheses that (1) polyelectrolyte multilayers have an effect on osseointegration in vivo; (2) multilayers of chitosan/hyaluronic acid decrease osteoblast proliferation compared to native titanium alloy, and hence reduce osseointegration; (3) multilayers of chitosan/gelatine increase osteoblast proliferation compared to native titanium alloy, hence enhance osseointegration. Polyelectrolyte multilayers on titanium alloy implants were fabricated by a layer-by-layer self-assembly process. Titanium alloy (Ti) implants were alternately dipped into gelatine (Gel), hyaluronic acid (HA) and chitosan (Chi) solutions, thus assembling a Chi/Gel and a Chi/HA coating with a terminating layer of Gel or HA, respectively. A rat tibial model with bilateral placement of titanium alloy implants was employed to analyze the bones' response to polyelectrolyte surfaces in vivo. 48 rats were randomly assigned to three groups of implants: (1) native titanium alloy (control), (2) Chi/Gel and (3) Chi/HA coating. Mechanical fixation, peri-implant bone area and bone contact were evaluated by pull-out tests and histology at 3 and 8 weeks. Shear strength at 8 weeks was statistically significantly increased (p<0.05) in both Chi/Gel and Chi/HA groups compared to the titanium alloy control. No statistically significant difference (p>0.05) in bone contact or bone area was found between all groups. No decrease of osseointegration of Chi/HA-coated implants compared to non-coated implants was found. The results of polyelectrolyte coatings in a rat model showed that the Chi/Gel and Chi/HA coatings have a positive effect on mechanical implant anchorage in normal bone.
BACKGROUND:The effects of freezing-thawing cycles on intramedullary bone-implant interfaces have been studied in a rat model in mechanical pull-out tests. IMPLANTS: Twenty TiAl6V4 rods (Ø 0.8 mm, length 10 mm) implanted in rat tibiaeMETHODS:10 rats underwent bilateral tibial implantation of titanium rods. At eight weeks, the animals were sacrificed and tibiae harvested for biomechanical testing. Eight tibiae were frozen and stored at -20°C for 14 days, the remaining eight were evaluated immediately post-harvest. Pull-out tests were used to determine maximum force and interfacial shear strength.RESULTS:There were no significant differences between fresh and those of the frozen-thawed group in maximum force or in interfacial shear strength.CONCLUSION:Frozen Storage of rat tibiae containing implants at -20° C has no effects on the biomechanical properties of Bone/ Implant interface.
Many different technologies have been used to enhance osseointegration in orthopaedic and dental implant surgery. Hydroxyapatite coatings, pure or in combination with growth factors or bisphosphonates, showed improved osseointegration of titanium alloy implants. We choose a different approach to enhance osseointegration: plasma chemical oxidation was used to modify the surface of titanium alloy implants. This technique converts the nm-thin natural occurring titanium oxide layer on an implant to a 4 μm thick ceramic coating (TiOB surface). Bioactive TiOB surfaces have a macroporous structure and were loaded with calcium and phosphorus, while bioinert TiOB surfaces are smooth. A rat tibial model with bilateral placement of titanium alloy implants was employed to analyze the bone response to TiOB surfaces in vivo. 64 rats were randomly assigned to four groups of implants: (1) titanium alloy (control), (2) titanium alloy, type III anodization, (3) bioinert TiOB surface and (4) bioactive TiOB surface. Mechanical fixation, peri-implant-bone area and bone contact were evaluated by pull-out tests and histology at three and eight weeks. Shear strength and bone contact at eight weeks were significantly increased in the bioactive TiOB group compared to all other groups. The results of plasma chemical oxidation in a rat model showed that the bioactive TiOB surface has a positive effect on implant anchorage by enhancing the bone-implant contact in normal bone.
Composite tissue allotransplantation represents a new discipline in reconstructive surgery. Over the past 10 years, we have performed six human vascularized allogeneic knee transplantations. All of these grafts have been lost within the first 56 months. A histomorphologic assessment of the latest case resulted in the detection of diffuse concentric fibrous intimal thickening and occlusion of graft vessels. Findings are comparable with cardiac allograft vasculopathy. The lack of adequate tools for monitoring graft rejection might have allowed multiple untreated episodes of acute rejection, triggering myointimal proliferation and occlusion of graft vessels. Graft vasculopathy represents an obstacle to long-term vascularized bone and joint allograft survival, and adequate tools for monitoring need to be developed.