Background: Collagen-based scaffolds are widely used in regenerative applications, where their structural organization and physicochemical stability are essential for clinical performance. This study aimed to evaluate the influence of hydration on the thermal behavior and microstructural characteristics of a collagen-based matrix (Mucoderm®, Botiss Biomaterial GmbH, Zossen-Germany). Methods: Differential scanning calorimetry (DSC) was used to investigate thermal transitions in dry and rehydrated samples, while scanning electron microscopy (SEM) coupled with energy-dispersive spectroscopy (EDS) was employed to assess surface morphology and elemental composition; Results: The dry sample exhibited a broad endothermic transition at 87.8 °C, which shifted to higher temperatures upon rehydration, reaching 103.5 °C and 112.4 °C after 15 and 30 min, respectively. A corresponding increase in enthalpy values was also observed. SEM analysis revealed a heterogeneous surface morphology characterized by alternating compact and less dense regions, while EDS confirmed the predominance of carbon and oxygen with minor elements present in trace amounts; Conclusions: These findings indicate that hydration influences both the thermal response and structural organization of the scaffold, highlighting the role of water-matrix interactions in determining its physicochemical behavior.
The paper continues the authors' efforts to characterize and control the shape memory effect (SME) occurring in 3D printed specimens of recycled polyethylene terephthalate (rPET) and polyethylene terephthalate glycol (rPETG). Lamellar and "dog-bone" configuration specimens were 3D printed in the form of stratified composites with five different rPET/rPETG ratios, 100:0, 60:40, 50:50, 40:60, and 0:100, and two different angles between the specimen's axis and the deposition direction, 0° and 45°. The lamellar specimens were used for: (i) free-recovery SME-investigating experiments, which monitored the variation of the displacement, of the free end of specimens which were bent at room temperature (RT), vs. temperature, during heating, (ii) differential scanning calorimetry (DSC), which emphasized heat flow variation vs. temperature, during glass transition and (iii) dynamic mechanical analysis (DMA), which recorded storage modulus vs. temperature in the glass transition interval. Dog-bone specimens were subjected to tensile failure and loading-unloading tests, performed at RT. The broken gauges were metallized with an Au layer and analyzed by scanning electron microscopy (SEM). The results showed that the specimens printed with 0° raster developed larger free-recovery SME strokes, the largest one corresponding to the specimen with rPET/rPETG = 40:60, which experienced the highest storage modulus increase, 872 MPa, and maximum value, 1818 MPa, during heating. The straight lamellar composite specimens experienced a supplementary shape recovery when bent at RT and heated, in such a way that their upper surface became concave, at the end of heating. Most of the specimens 3D printed at 0° raster developed stress failure plateaus, which were associated with the formation of delamination areas on SEM fractographs, while the specimens printed with 45° raster angle experienced necking failures, associated with the formation of crazing areas. The results suggested that 3D printed stratified rPET-rPETG composites, with dedicated spatial configurations, have the potential to serve as executive elements of light actuators for low-temperature operation.
In the engineering industry, metals and alloys used in the manufacture of metal products and structures are subjected to welding processes, which can release metal vapors, harmful dust and particles into the air, with negative effects on workers' health and the environment. Some joining methods generate hazardous gases, categorized as greenhouse gases, toxic gases, flammable gases and explosive gases. There are clear regulations on the permissible limits for concentrations of metallic and non-metallic particulates and gases emitted by various industrial processes, including welding. The aim of this research was to measure chemical agents in the workplace air as well as respirable and respirable dust concentrations in the workplace atmosphere at a company in the Semi-Fabricated Joining Section for the position of a manual electric welder. The determinations of chemical agents and of respirable and inhalable dusts were carried out in the workers' breathing zone between 08(00) and 14(00).
A shape memory alloy with the chemical composition Fe-14Mn-6Si-9Cr-5Ni (mass %) was produced by powder metallurgy (PM) from as-blended powders mixed with mechanically alloyed (MA’ed) powder volumes in amounts of 0, 10 and 20. After powder blending, pressing and sintering, the specimens were hot-rolled, spark erosion cut with different configurations and solution-treated between 700 and 1100 °C. After metallographic preparation, structural analyses were performed by X-ray diffraction and microscopic observation performed by optical and scanning electron microscopy (SEM). The analyses revealed the presence of thermal- and stress-induced martensites caused by solution treatment and pre-straining. Due to the relatively low Mn amount, significant quantities of α′ body center cubic martensite were formed during post-solution treatment water cooling. Solution-treated lamellar specimens underwent a training thermomechanical treatment comprising repeated cycles of room temperature bending, heating and sputtered water cooling. By cinematographic analysis, the occurrence of the shape memory effect (SME) was revealed, in spite of the large amount of α′ bcc martensite. Tensile specimens were subjected to room temperature failure tests and pre-straining (up to 4% permanent strain, after loading–unloading). After tensile pre-straining, a diminution of α′ martensite amount was noticed on XRD patterns, which was associated with the formation of internal sub-bands in the substructure of martensite and were observed by high-resolution SEM. These results prove that SME can be obtained in trained PM_MA’ed Fe-14Mn-6Si-9Cr-5Ni specimens in spite of the large amount of thermally induced α′ bcc martensite, the stress-induced formation of which is impeded by the presence of internal sub-bands.
The relationship between ergonomics and burnout is complex and has received substantial attention in modern occupational health research, especially as workplace demands grow and technological advancements alter the employment landscape. Burnout is a recognized occupational health issue and a growing concern throughout Europe. Governments, employers, and health professionals are increasingly focusing on it. In Romania, labour legislation includes measures designed to prevent and combat burnout in the workplace. This is addressed through regulations regarding working hours, rest periods, and health and safety standards. Although burnout is not yet officially recognized as a medical diagnosis, it is categorized as a psychosocial condition in workplace risk assessments. Medical professionals may refer to it as severe occupational stress and may recommend sick leave or psychological counselling for affected individuals. The aim of this study is to promote the well-being of workers by advocating for a shift in the prevention and management of burnout. This change is crucial due to the significant impact of burnout on individuals and workplaces.
The manufacture of safety footwear is subject to a number of mandatory regulations to ensure safety during use. As protective footwear has evolved, a number of tests have been required to ensure that the product fully protects the individual, as required by ergonomic standards (EN ISO 20344). In all workplaces, accidents caused by heavy or massive objects are common for a variety of reasons. In this study, compression tests have been performed on personal protective footwear, including other parameters not included in the testing standards for this type of footwear, such as time and temperature.
This manuscript highlights the behavior of biodegradable polymers (PLA and HD PLA Green) coated with two distinct bronze alloy powders, Metco 51F-NS (Cu 9.5Al 1.2Fe) and Metco 445 (Cu 9.5Al). The coating was realized on printed samples by using the Atmospheric Plasma Spray (APS) technique. The current investigation will explain the results related to the surface quality, micro-structure, morphology, and thermal and tribological properties. Thus, from a structural point of view, the most uniform deposition was obtained in the case of composite powder Metco 51F-NS. The thermal behavior of the samples coated with copper-based powder achieved stability up to temperatures slightly above 200 °C, with carbonization of the matrix structure taking place around 350 °C. The micro-indentation and scratch analysis responses were significantly influenced by the semicrystalline structure of the samples and the presence of the powder compounds. Based on the increased characteristics of the coated samples, the authors of the present paper consider that parts made of biodegradable polymers and coated with copper microparticles are appropriate for some applications which take place in adverse operating conditions.
One of the useful features of 3D-printed specimens of recycled polyethylene terephthalate glycol (R-PETG) is the ability to repetitively develop free recovery as well as the work-generating, shape-memory effect. This behavior is enabled by the R-PETG’s capacity to stiffen during cooling, thus allowing for a new temporary shape to be induced. Aiming to devise an explanation for the polymer’s stiffening, in this study, the variation in some of the R-PETG’s parameters during cooling are emphasized and discussed. The evolution of an R-PETG filament’s shape was monitored during room-temperature-bending heating–cooling cycles. Straight-shape recovery and the complete loss of stiffness were observed at the start and the end of heating, respectively, followed by the forced straightening of the filament, performed by the operator, around 40 °C, during cooling. The tests performed by dynamic mechanical analysis disclosed the rise of the storage modulus (E’) after 100 °C heating followed by either liquid-nitrogen- or air-cooling to room temperature, in such a way that E’ was always larger after cooling than initially. Static tests emphasized a peculiar stress variation during a heating–cooling cycle applied in air, within the heating chamber of the tensile testing machine. Tensile-failure tests were performed at −10 °C at a rate of 100 mm/min, with specimens printed at various deposition directions between 10 and 40° to the transversal direction. The specimens printed at 40°, which had the largest ultimate strains, were broken with tensile rates between 100 and 500 mm/min. Deformation rate increase favored the shift from crazing to delamination failure modes. The correlation between the structural changes, the sharp E’ increase on heating, and the stiffening induced by cooling represents a novel approach that enables the use of 3D-printed R-PETG for the fabrication of the active parts of low-priced lightweight resettable actuators.
In the present study, the capacity of two commercial NiTi and NiTiCu shape memory alloy (SMA) wires to develop work-generating (WG) and constrained-recovery (CR) shape memory effects (SMEs), as well as the capacity of a commercial NiTiFe super-elastic wire to act as cold-shape restoring element, have been investigated. Using differential scanning calorimetry (DSC), the reversible martensitic transformation to austenite of the three NiTi-based wires under study was emphasized by means of an endothermic minimum of the heat flow variation with temperature. NiTi and NiTiCu wire fragments were further tested for both WG-SME and CR-SME developed during the heating, from room temperature (RT) to different maximum temperatures selected from the DSC thermograms. The former tests revealed the capacity to repetitively lift various loads during repetitive heating, while the latter tests disclosed the repetitive development of shrinkage stresses during the repetitive heating of elongated wires. The tensile behavior of the three NiTi-based SMA wires was analyzed by failure and loading–unloading tests. The study disclosed the actuation capacity of NiTi and NiTiCu shape memory wires, which were able to develop work while being heated, as well as the resetting capacity of NiTiFe super-elastic wires, which can restore the initial undeformed shape of shape memory wires which soften while being cooled down. These features enable the design of a robotic gripper based on the development of NiTi-based actuators with repetitive action.
The paper starts by describing the manufacturing process of cups thermoformed from extruded foils of 80% recycled PET (80r-PET), which comprises heating, hot deep drawing and cooling. The 80r-PET foils were heated up to 120 °C, at heating rates of the order of hundreds °C/min, and deep drawn with multiple punchers, having a depth-to-width ratio exceeding 1:1. After puncher-assisted deformation, the cups were air blown away from the punchers, thus being “frozen” in the deformed state. Due to the high cooling rate, most of the polymer’s structure reached a rigid, glassy state, the internal stresses that tended to recover the flat undeformed state were blocked and the polymer remained in a temporary cup form. When heating was applied, glass transition occurred, and the polymer reached a rubbery state and softened. This softening process released the blocked internal stresses and the polymer tended to recover its flat permanent shape. This relative volume contraction quantitatively describes the shape memory effect (SME) which can be obtained either with free recovery (FR-SME) or with work generation (WG-SME) when the cups lifted their bottoms with different loads placed inside them. The paper discusses the results obtained by differential scanning calorimetry (DSC), dynamic mechanical analysis (DMA), room-temperature tensile failure tests (TENS) and scanning electron microscopy (SEM). The DSC charts emphasized a glass transition, responsible for SME occurrence. The DMA thermograms and the TENS curves revealed that there are slight differences between the storage modulus and the tensile strains of the specimens cut on longitudinal, transversal, or 45° to the film rolling direction. The SEM micrographs enabled to observe structural differences between the specimens cut parallelly and transversally to the film’s rolling direction. The thermoformed cups were heated on a special experimental setup, which enabled the determination of FR-SME and WG-SME after applying different maximum temperatures and loads placed into the cups, respectively.
From commercial pellets of recycled polyethylene terephthalate glycol (R-PETG), 1.75 mm diameter filaments for 3D printing were produced. By varying the filament’s deposition direction between 10° and 40° to the transversal axis, parallelepiped specimens were fabricated by additive manufacturing. When bent at room temperature (RT), both the filaments and the 3D-printed specimens recovered their shape during heating, either without any constraint or while lifting a load over a certain distance. In this way, free-recovery and work-generating shape memory effects (SMEs) were developed. The former could be repeated without any visible fatigue marks for as much as 20 heating (to 90 °C)-RT cooling–bending cycles, while the latter enabled the lifting of loads over 50 times heavier than the active specimens. Tensile static failure tests revealed the superiority of the specimens printed at larger angles over those printed at 10°, since the specimens printed at 40° had tensile failure stresses and strains over 35 MPa and 8.5%, respectively. Scanning electron microscopy (SEM) fractographs displayed the structure of the successively deposited layers and a shredding tendency enhanced by the increase in the deposition angle. Differential scanning calorimetry (DSC) analysis enabled the identification of the glass transition between 67.5 and 77.3 °C, which might explain the occurrence of SMEs in both the filament and 3D-printed specimens. Dynamic mechanical analysis (DMA) emphasized a local increase in storage modulus of 0.87–1.66 GPa that occurred during heating, which might explain the development of work-generating SME in both filament and 3D-printed specimens. These properties recommend 3D-printed parts made of R-PETG as active elements in low-price lightweight actuators operating between RT and 63 °C.
The medical applications of degradable iron-based biomaterials have been targeted by re-searchers due to their special properties that they present after alloying with various elements and different technological methods of obtaining. Compared to other biodegradable materials, iron-based alloys are designed especially for the low production costs, the non-magnetism obtained by alloying with Mn, and the shape memory effect (SME) following the alloying with Si, which is necessary in medical applications for which it could replace nitinol successfully. Alloying with new elements could improve the mechanical properties, the degradation rate, and the transformation temperatures corresponding to the SME. This paper presents the results from the study of FeMnSi-Al alloy as a biodegradable material. The X-ray diffraction (XRD) method was used to identify the phases formed in the experimental Fe-Mn-Si-Al alloy, and the SME was studied by differential scanning calorimetry (DSC). In vitro tests were performed by immersing the samples in Ringer’s biological solution for different time intervals (1, 3, and 7 days). The chemical composition of the samples, as well as the compounds resulting from the immersion tests, were evaluated by energy dispersive X-ray (EDS). Scanning electron microscopy (SEM) was used for the microstructural analysis and for highlighting the surfaces subjected to contact with the electrolyte solution. The corrosion rate (CR, mm/yr.) was calculated after mass loss, sample surface area, and immersion time (h) (at 37 °C). Samples were subjected to electro-corrosion tests using electrochemical impedance spectroscopy (EIS) and Tafel linear and cyclic potentiometry.
Iron-based SMAs can be used in the medical field for both their shape memory effect (SME) and biodegradability after a specific period, solving complicated chirurgical problems that are partially now addressed with shape-memory polymers or biodegradable polymers. Iron-based materials with (28–32 wt %) Mn and (4–6 wt %) Si with the addition of 1 and 2 wt % Ag were obtained using levitation induction melting equipment. Addition of silver to the FeMnSi alloy was proposed in order to enhance its antiseptic property. Structural and chemical composition analyses of the newly obtained alloys were performed by X-ray diffraction (confirming the presence of ε phase), scanning electron microscopy (SEM) and energy-dispersive spectroscopy. The corrosion resistance was evaluated through immersion tests and electrolyte pH solution variation. Dynamic mechanical solicitations were performed with amplitude sweep performed on the FeMnSi–1Ag and FeMnSi–2Ag samples, including five deformation cycles at 40 °C, with a frequency of 1 Hz, 5 Hz and 20 Hz. These experiments were meant to simulate the usual behavior of some metallic implants subjected to repetitive mechanical loading. Atomic force microscopy was used to analyze the surface roughness before and after the dynamic mechanical analysis test followed by the characterization of the surface profile change by varying dynamic mechanical stress. Differential scanning calorimetry was performed in order to analyze the thermal behavior of the material in the range of −50–+200 °C. X-ray diffraction and Fourier transform infrared spectroscopy (FTIR) along with Neaspec nano-FTIR experiments were performed to identify and confirm the corrosion compounds (oxides, hydroxides or carbonates) formed on the surface.
A Ti50Ni45Cu5 shape memory alloy (SMA) was cast, homogenized and hot rolled into 0.5 mm-thick lamellas. After homogenization, the intercrystalline Ti2(Ni, Cu) based solid solution, gradually decomposed with the increase of hold temperature and time, as pointed out by optical, scanning electron and atomic force microscopy. After hot rolling, by wire spark erosion, rectangular specimens with the dimensions 0.5 mm × 2 mm × 6 mm were cut each one with a mass of 0.44 g. Since the specimens experienced a thermoelastic martensitic transformation, while being martensitic at room temperature (RT) they were soft and could be easily bent against cylindrical calibers, in order to induce their “cold” (martensitic) shape. When heated, up to 100 °C with a hot air gun, they readily recovered, by shape memory effect (SME) their initial straight form, also known as “hot shape”. Thermomechanical training cycles were subsequently applied, consisting in: (i) RT bending; (ii) hot air gun heating and (iii) air cooling. These cycles were repeated up to 50 times. The effects of the thermomechanical training cycles were subsequently analyzed, by differential scanning calorimetry, on fragments cut from the active sections of the specimens. It was noticed that training basically increased thermal hysteresis. Finally, experiments were performed which demonstrated the capacity of Ti50Ni45Cu5 SMA elements to develop.
Biodegradable metallic materials are increasingly gaining ground in medical applications. Zn-based alloys show a degradation rate between those recorded for Mg-based materials with the fastest degradation rate and Fe-based materials with the slowest degradation rate. From the perspective of medical complications, it is essential to understand the size and nature of the degradation products developed from biodegradable materials, as well as the stage at which these residues are eliminated from the body. This paper presents investigations conducted on the corrosion/degradation products of an experimental material (ZnMgY alloy in cast and homogenized state) after immersion tests in three physiological solutions (Dulbecco's, Ringer's and simulated body fluid (SBF)). Scanning electron microscopy (SEM) was used to highlight the macroscopic and microscopic aspects of corrosion products and their effects on the surface. An X-ray energy dispersive detector (EDS), X-ray diffraction (XRD) and Fourier transform infrared spectroscopy (FTIR) provided general information about the compounds based on their non-metallic character. The pH of the electrolyte solution was recorded for 72 h during immersion. The pH variation of the solution confirmed the main reactions proposed for the corrosion of ZnMg. The agglomerations of corrosion products were on the micrometer scale, mainly oxides, hydroxides and carbonates or phosphates. The corrosion effects on the surface were homogeneously spread, with a tendency to connect and form cracks or larger corrosion zones, transforming the pitting corrosion pattern into a generalized one. It was noticed that the alloy's microstructure strongly influences the corrosion characteristics.
SAE 430B is a Cu-based alloy, which, due to good properties qualify the alloy in special bronzes category. In this paper, the influence of the casting parameters on the properties of the SAE 430B cast in two types of moulds: (i) temporary (based on quartos sand) and (ii) permanent (metallic mould). Samples in as-cast condition were cut and prepared for chemical and microstructural analysis. The chemical composition was determined via spectroscopic analysis, the structural characterization was carried out by optical and electronic microscopy. EDS chemical analysis was used to identify the compositions of phases and compounds in the material. The corrosion behaviour was analysed in seawater by a linear potentiodynamic polarization test. The microstructure of as-cast samples presents a β phase structure with intermetallic precipitates with various morphologies. With the increase in cooling rate, corrosion potential values become more negative and current density increases.
Fe-Mn-Si-based shape memory alloys (SMAs) have been extensively investigated since 1982 for various useful properties that enhance the development of different applications such as anti-seismic dampers for very tall buildings, pipe joints, or rail fasteners. In particular, the Fe-28Mn-6Si-5Cr (mass. %) alloy has been mainly used in vibration mitigation or self-adjustable axial displacement applications. Dynamic mechanical analysis (DMA), performed by strain sweeps (SS), enables the monitoring of the evolution of storage modulus and internal friction variations with increasing strain amplitudes at different constant frequencies and temperatures. Thus, applying dynamic bending with various frequencies and amplitudes that actually represents an isothermal mechanical treatment. In the present paper, an Fe-28Mn-6 Si-5Cr (mass. %) SMA was cast by ingot metallurgy, hot-rolled, and water quenched in order to obtain thermally induced martensite and avoid the occurrence of cooling cracks. The influence of the holding time, between 2 and 10 h, at 1050 °C and the effects of DMA-SS performed at three different frequencies were analyzed by a differential scanning calorimetry, an X-ray diffraction, and a scanning electron and atomic force microscopy. The effects of the holding time and mechanical treatment on the structure and morphology of martensite plates were corroborated with the results of the thermal analysis.
A commercial NiTi alloy with the chemical composition of 54.5 Ni-45.5 Ti (mass %) was used as a standard material to be compared with Ti50Ni45Cu5, 48 Ni-37 Ti-15 Nb (mass. %) and 48 Ni- 37 Ti-15 Ta (mass. %). The experimental alloys were cast, annealed and hot rolled in order to render the material more compact and to obtain 0.5 mm-thick lamellas. Two types of specimens were then obtained. The former were fragments with a mass of less than 50 mg that were cut and cleaned in alcohol, in an ultrasonic bath, before being subjected to differential scanning calorimetry (DSC) analysis. The latter were 0.5 × 4 × 25 mm rectangular specimens that were prepared to be subjected to dynamic mechanical analyses (DMA) and optical analysis (OM). The DSC investigation program comprised a heating–cooling cycle with a rate of 10 K/min and was used in order to obtain the critical transformation temperatures of direct and reverse martensitic transformations. DMA measurements consisting in a heating cycle with a heating rate of 5 K/min, a frequency of 1 Hz, a maximum deformation of 20 µm and a maximum of 9 N dynamical applied force, were used in order to observe the mechanical behavior under dynamic conditions. DSC tests suggested that Cu and Ta alloying led to an increase of critical temperatures of reverse martensitic transformation while Nb alloying dropped these critical temperatures as low as 0 °C. In addition, Ta alloying significantly increased the transformation temperatures. All the DMA thermograms emphasized a maximum of internal friction that could be associated with the reverse martensitic transformation. Storage modulus exhibited either continuous or step-like increase during heating, suggesting the presence of a thermoelastic transformation.
Special materials are required in many applications to fulfill specific medical or industrial necessities. Biodegradable metallic materials present many attractive properties, especially mechanical ones correlated with good biocompatibility with vivant bodies. A biodegradable iron-based material was realized through electric arc-melting and induction furnace homogenization. The new chemical composition obtained presented a special property named SME (shape memory effect) based on the martensite transformation. Preliminary results about this special biodegradable material with a new chemical composition were realized for the chemical composition and structural and thermal characterization. Corrosion resistance was evaluated in Ringer's solution through immersion tests for 1, 3, and 7 days, the solution pH was measured in time for 3 days with values for each minute, and electro-corrosion was measured using a potentiostat and a three electrode cell. The mass loss of the samples during immersion and electro-corrosion was evaluated and the surface condition was studied by scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). SME was highlighted with differential scanning calorimetry (DSC). The results confirm the possibility of a memory effect of the materials in the wrought case and a generalized corrosion (Tafel and cyclic potentiometry and EIS) with the formation of iron oxides and a corrosion rate favorable for applications that require a longer implantation period.
Active elements made of Ti50Ni45Cu5 shape memory alloy (SMA) were martensitic at room temperature (RT) after hot rolling with instant water quenching. These pristine specimens were subjected to two thermomechanical training procedures consisting of (i) free recovery shape memory effect (FR-SME) and (ii) work generating shape memory effect (WG-SME) under constant stress as well as dynamic bending and RT static tensile testing (TENS). The structural-functional changes, caused by the two training procedures as well as TENS were investigated by various experimental techniques, including differential scanning calorimetry (DSC), dynamic mechanical analysis (DMA), X-ray diffraction (XRD), and atomic force microscopy (AFM). Fragments cut from the active regions of trained specimens or from the elongated gauges of TENS specimens were analyzed by DSC, XRD, and AFM. The DSC thermograms revealed the shift in critical transformation temperatures and a diminution in specific absorbed enthalpy as an effect of training cycles. The DMA thermograms of pristine specimens emphasized a change of storage modulus variation during heating after the application of isothermal dynamical bending at RT. The XRD patterns and AMF micrographs disclosed the different evolution of martensite plate variants as an effect of FR-SME cycling and of being elongated upon convex surfaces or compressed upon concave surfaces of bent specimens. For illustrative reasons, the evolution of unit cell parameters of B19′ martensite, as a function of the number of cycles of FR-SME training, upon concave regions was discussed. AFM micrographs emphasized wider and shallower martensite plates on the convex region as compared to the concave one. With increasing the number of FR-SME training cycles, plates’ heights decreased by 84–87%. The results suggest that FR-SME training caused marked decreases in martensite plate dimensions, which engendered a decrease in specific absorbed enthalpy during martensite reversion.