Background. Normothermic machine perfusion (NMP) protocols using blood-based solutions are commonly used in the assessment of kidneys before transplantation. This procedure is, nevertheless, limited by blood availability and warrants the search for alternatives. We compared a blood-based solution with a serum-like preservation solution (Aqix) enriched with colloids with and without red blood cells (RBCs). Methods. Porcine kidneys retrieved from an abattoir were subjected to 30min of warm ischemia, followed by 3h of hypothermic oxygenated machine perfusion at 4 degrees C. Subsequently, kidneys (n=6 per group) were evaluated with NMP for 4h with 5 different solutions: diluted blood, Aqix with BSARBCs, or Aqix with dextran 40RBCs. Results. Throughout NMP, markers of renal function and tubular metabolism were favorable in groups with RBCs. The addition of RBCs resulted in 4- to 6-fold higher oxygen consumption rates. Controls had significantly higher ATP levels post-NMP, exhibited decreased production of oxidative stress markers, and had the highest creatinine clearance. In conclusion, this study shows that the addition of RBCs during NMP reduced renal injury, improved function, and was associated with increased renal metabolism. Conclusions. Although the RBC-BSA-supplemented Aqix solution was also able to support metabolism and renal function, a blood-based perfusion solution remains superior.
Ischemia reperfusion injury is a complex process consisting of a seemingly chaotic but actually organized and compartmentalized shutdown of cell function, of which oxidative stress is a key component. Studying oxidative stress, which results in an imbalance between reactive oxygen species (ROS) production and antioxidant defense activity, is a multi-faceted issue, particularly considering the double function of ROS, assuming roles as physiological intracellular signals and as mediators of cellular component damage. Herein, we propose a comprehensive overview of the tools available to explore oxidative stress, particularly in the study of ischemia reperfusion. Applying chemistry as well as biology, we present the different models currently developed to study oxidative stress, spanning the vitro and the silico, discussing the advantages and the drawbacks of each set-up, including the issues relating to the use of in vitro hypoxia as a surrogate for ischemia. Having identified the limitations of historical models, we shall study new paradigms, including the use of stem cell-derived organoids, as a bridge between the in vitro and the in vivo comprising 3D intercellular interactions in vivo and versatile pathway investigations in vitro. We shall conclude this review by distancing ourselves from “wet” biology and reviewing the in silico, computer-based, mathematical modeling, and numerical simulation options: (a) molecular modeling with quantum chemistry and molecular dynamic algorithms, which facilitates the study of molecule-to-molecule interactions, and the integration of a compound in a dynamic environment (the plasma membrane...); (b) integrative systemic models, which can include many facets of complex mechanisms such as oxidative stress or ischemia reperfusion and help to formulate integrated predictions and to enhance understanding of dynamic interaction between pathways.
A post hoc analysis of the Diabeloop WP7 multicentre, randomized controlled trial was performed to investigate the efficacy of the Diabeloop Generation-1 (DBLG1) closed-loop system in controlling the hypoglycaemia induced by physical activity (PA) in real-life conditions. Glycaemic outcomes were compared between days with and without PA in 56 patients with type 1 diabetes (T1D) using DBLG1 for 12 weeks. After the patient announces a PA, DBLG1 reduces insulin delivery and, if necessary, calculates the amount of preventive carbohydrates (CHO). Daily time spent in the interstitial glucose range less than 70 mg/dL was not significantly different between days with and without PA (2.0% +/- 1.5% vs. 2.2% +/- 1.1%), regardless of the intensity or duration of the PA. Preventive CHO intake recommended by the system was significantly higher in days with PA (41.1 +/- 35.5 vs. 21.8 +/- 28.5 g/day; P < .0001), and insulin delivery was significantly lower (31.5 +/- 10.5 vs. 34.0 +/- 10.5 U/day; P < .0001). The time spent in hyperglycaemia and the glycaemic variation coefficient increased significantly on days with PA. In real-life conditions, the use of DBLG1 avoids PA-induced hypoglycaemia. Insulin adjustments and preventive CHO recommendation may explain this therapeutic benefit.
To compare closed‐loop (CL) and open‐loop (OL) systems for glycaemic control in patients with type 1 diabetes (T1D) exposed to real‐life challenging situations (gastronomic dinners or sustained physical exercise).
The renal cortex drives renal function. Hypoxia/reoxygenation are primary factors in ischemia-reperfusion (IR) injuries, but renal oxygenation per se is complex and awaits full elucidation. Few mathematical models address this issue: none captures cortical tissue heterogeneity. Using agent-based modeling, we develop the first model of cortical oxygenation at the cell-tissue level (RCM), based on first principles and careful bibliographical analysis. Entirely parameterized with Rat data, RCM is a morphometrically equivalent 2D-slice of cortical tissue, featuring peritubular capillaries (PTC), tubules and interstitium. It implements hemoglobin/O2 binding-release, oxygen diffusion, and consumption, as well as capillary and tubular flows. Inputs are renal blood flow RBF and PO2 feeds; output is average tissue PO2 (tPO2). After verification and sensitivity analysis, RCM was validated at steady-state (tPO2 37.7 ± 2.2 vs. 36.9 ± 6 mmHg) and under transients (ischemic oxygen half-time: 4.5 ± 2.5 vs. 2.3 ± 0.5 s in situ). Simulations confirm that PO2 is largely independent of RBF, except at low values. They suggest that, at least in the proximal tubule, the luminal flow dominantly contributes to oxygen delivery, while the contribution of capillaries increases under partial ischemia. Before addressing IR-induced injuries, upcoming developments include ATP production, adaptation to minutes–hours scale, and segmental and regional specification.
The growing use of marginal organs for transplantation pushes current preservation methods toward their limits, and the need for improvement is pressing. We previously demonstrated the benefits of M101, a natural extracellular oxygen carrier compatible with hypothermia, for the preservation of healthy renal grafts in a porcine model of autotransplantation. Herein, we use a variant of this preclinical model to evaluate M101 potential benefits both in static cold storage (CS) and in machine perfusion (MP) preservation in the transplantation outcomes for marginal kidneys. In the CS arm, despite the absence of obvious benefits within the first 2 weeks of follow-up, M101 dose-dependently improved long-term function, normalizing creatininemia after 1 and 3 months. In the MP arm, M101 improved short- and long-term functional outcomes as well as tissue integrity. Importantly, we provide evidence for the additivity of MP and M101 functional effects, showing that the addition of the compound further improves organ preservation, by reducing short-term function loss, with no loss of function or tissue integrity recorded throughout the follow-up. Extending previous observations with healthy kidneys, the present results point at the M101 oxygen carrier as a viable strategy to improve current organ preservation methods in marginal organ transplantation.
Ischemia-reperfusion (IR) injury is unavoidable during organ transplantation and impacts graft quality. New paradigms are emerging including preservation at higher temperature than "hypothermia" or "cold": although 4°C remains largely used for kidney preservation, recent studies challenged this choice. We and others hypothesized that a higher preservation temperature, closer to physiological regimen, could improve organ quality. For this purpose, we used an in vitro model of endothelial cells exposed to hypoxia-reoxygenation sequence (mimicking IR) and an ex vivo ischemic pig kidneys static storage model. In vitro, 19°C, 27°C, and 32°C provided protection against injuries versus 4°C, by reducing cell death, mitochondrial dysfunction, leukocyte adhesion, and inflammation. However, ex vivo, the benefits of 19°C or 32°C were limited, showing similar levels of tissue preservation damage. Ex vivo 4°C-preserved kidneys displayed a trend towards reduced damage, including apoptosis. Macrophage infiltration, tubulitis, and necrosis were increased in the 19°C and 32°C versus 4°C preserved kidneys. Thus, despite a trend for an advantage of subnormothermia as preservation temperature, our in vitro and ex vivo models bring different insights in terms of preservation temperature effect. This study suggests that temperature optimization for kidney preservation will require thorough investigation, combining the use of complementary relevant models and the design of elaborated preservation solution and new technologies.
Static cold storage (SCS) and hypothermic machine perfusion (HMP) are currently standard methods for renal grafts clinical preservation. Both methods are predominantly implemented without the active delivery of oxygen, even for donation after circulatory death-like kidneys. However, even under severe hypothermia (4°C-6°C), kidneys can consume oxygen and produce ATP. What is not established, though, is to what extent and how SCS and HMP compare in terms of oxygen. Using a porcine preclinical model of renal warm ischemia (WI) to compare SCS and HMP methods, we continuously monitored and quantified oxygen level and consumption along preservation; we also determined prepreservation and postpreservation cortical ATP level; values were given as median and [min; max] range. One-hour WI reduced ATP by ∼90% (from 3.3 [1.7; 4.5] mmol/L tissue in Controls). Oxygen consumption (QO2, μmol/min per 100 g) was determined from initial solution PO2 decrease (SCS and HMP) and from arterio-venous difference (HMP). In SCS and HMP, PO2 decreased rapidly (t1/2 ∼1 h) from atmospheric levels to 52.9 [38.0; 65.9] and 8.2 [3.0, 16.0] mmHg, respectively. In HMP, QO2 was 2.7 [0.4; 3.9] versus 0.5 [0.0; 1.3] in SCS (P < 0.05); postpreservation ATP amounted to 5.8 [3.2; 6.5] in HMP versus 0.1 [0.0; 0.2] in SCS. Despite hypothermic conditions in SCS or HMP, donation after circulatory death-like renal grafts require oxygen. Increased oxygen consumption, restored ATP level, and improved histological profile in HMP might explain the established HMP superiority over SCS. These results establish a rational basis for the use of oxygen in hypothermic preservation. Optimal levels required for preservation and graft-type variants remain to be determined.
Introduction: Although postnatal depression is now well recognized, there is also a risk of depressive symptoms during perimenopause. The mechanisms underlying perimenopausal depression are still poorly understood; however, there are available treatment options. Areas covered: This review describes: the current pharmacotherapeutic approaches for perimenopausal depression, their strengths and weakness, and provides recommendations on how current treatment can be improved in the future. An electronic search identified specific guidelines for the treatment of perimenopausal depression released in 2018, as well as recent clinical studies on the subject. Expert opinion: The 2018 guidelines recommend selective serotonin reuptake inhibitors (SSRIs) and serotonin and noradrenaline reuptake inhibitors (SNRIs) as front-line medications for perimenopausal depression, but SSRIs and SNRIs are not always effective. The efficacy of estrogen in perimenopausal depression is well documented, but estrogen is not FDA-approved to treat mood disturbances in perimenopausal women. Clinical practice guidelines currently recommend to restrict hormone therapy to the symptomatic treatment of menopause (not for the prevention of chronic diseases). Research with new estrogenic compounds is under way to improve their benefit/risk ratio in perimenopausal depression.
Background. Hypothermic machine perfusion (HMP) has become standard care in many center’s to preserve kidneys donated after circulatory death (DCD). Despite a significant reduction in metabolism at low temperatures, the remaining cellular activity requires oxygen. Because of the role and safety of oxygen during HMP has not been fully clarified, its supply during HMP is not standard yet. This study investigates the effect of administering oxygen during HMP on renal function in a porcine DCD model. Methods. After 30 minutes of warm ischemia, porcine slaughterhouse kidneys were preserved for 24 hours by means of cold storage (CS), or HMP with Belzer Machine Perfusion Solution supplemented with no oxygen, 21% or 100% oxygen. Next, kidneys were reperfused for 4 hours in a normothermic machine perfusion setup. Results. HMP resulted in significantly better kidney function during normothermic machine perfusion. Thiobarbituric acid-reactive substances, markers of oxidative stress, were significantly lower in HMP preserved kidneys. HMP preserved kidneys showed significantly lower aspartate aminotransferase and lactate dehydrogenase levels compared with kidneys preserved by CS. No differences were found between the HMP groups subjected to different oxygen concentrations. Adenosine triphosphate levels significantly improved during HMP when active oxygenation was applied. Conclusions. This study showed that preservation of DCD kidneys with HMP is superior to CS. Although the addition of oxygen to HMP did not result in significantly improved renal function, beneficial effects were found in terms of reduced oxidative stress and energy status. Oxygen addition proofed to be safe and did not show detrimental effects.
Despite the fact that a significant fraction of kidney graft dysfunctions observed after transplantation is due to ischemia-reperfusion injuries, there is still no clear consensus regarding optimal kidney preservation strategy. This stems directly from the fact that as of yet, the mechanisms underlying ischemia-reperfusion injury are poorly defined, and the role of each preservation parameter is not clearly outlined. In the meantime, as donor demography changes, organ quality is decreasing which directly increases the rate of poor outcome. This situation has an impact on clinical guidelines and impedes their possible harmonization in the transplant community, which has to move towards changing organ preservation paradigms: new concepts must emerge and the definition of a new range of adapted preservation method is of paramount importance. This review presents existing barriers in transplantation (e.g., temperature adjustment and adequate protocol, interest for oxygen addition during preservation, and clear procedure for organ perfusion during machine preservation), discusses the development of novel strategies to overcome them, and exposes the importance of identifying reliable biomarkers to monitor graft quality and predict short and long-term outcomes. Finally, perspectives in therapeutic strategies will also be presented, such as those based on stem cells and their derivatives and innovative models on which they would need to be properly tested.
Ex vivo machine perfusion of the liver after cold storage has found to be most effective if combined with controlled oxygenated rewarming up to (sub)-normothermia. On disconnection of the warm graft from the machine, most surgeons usually perform a cold flush of the organ as protection against the second warm ischemia incurred upon implantation. Experimental evidence, however, is lacking and protective effect of deep hypothermia has been challenged for limited periods of liver ischemia in other models. A first systematic test was carried out on porcine livers, excised 30 min after cardiac arrest, subjected to 18 h of cold storage in UW and then machine perfused for 90 min with Aqix-RSI solution. During machine perfusion, livers were gradually rewarmed up to 20 °C. One group (n = 6) was then reflushed with 4 °C cold Belzer UW solution whereas the second group (n = 6) remained without cold flush. All livers were exposed to 45 min warm ischemia at room temperature to simulate the surgical implantation period. Organ function was evaluated in an established reperfusion model using diluted autologous blood. Cold reflush after disconnection from the machine resulted in a significant increase in bile production upon blood reperfusion, along with a significant reduction in transaminases release alanine aminotransferase and of the intramitochondrial enzyme glutamate dehydrogenase. Interestingly, free radical-mediated lipid peroxidation was also found significantly lower after cold reflush. No differences between the groups could be evidenced concerning histological injury and recovery of hepatic energy metabolism (tissue content of adenosine triphosphate). Post-machine preservation cold reflush seems to be beneficial in this particular setting, even if the organs are warmed up only to 20 °C, without notion of adverse effects, and should therefore be implemented in the protocol.
Due to organ shortage, clinicians are prone to consider alternative type of organ donors among them donors deceased after circulatory death (DCD). However, especially using these organs which are more prone to graft dysfunction, there is a need to better understand mechanistic events ocuring during ischemia phase and leading to ischemia/reperfusion injuries (IRI). The aim of this study is to provide a dynamic transcriptomic analysis of preclinical porcine model kidneys subjected to ischemic stress mimicking DCD donor. We compared cortex and corticomedullary junction (CMJ) tissues from porcine kidneys submitted to 60 min warm ischemia (WI) followed by 0, 6 or 24 hours of cold storage in University of Wisconsin solution versus control non-ischemic kidneys (n = 5 per group). 29 cortex genes and 113 CMJ genes were significantly up or down-regulated after WI versus healthy kidneys, and up to 400 genes were regulated after WI followed by 6 or 24 hours of cold storage (p < 0.05). Functionnal enrichment analysis (home selected gene kinetic classification, Gene-ontology-biological processes and Gene-ontology-molecular-function) revealed relevant genes implication during WI and cold storage. We uncovered targets which we will further validate as biomarkers and new therapeutic targets to optimize graft kidney quality before transplantation and improve whole transplantation outcome.
&NA; COPE Consortium. Background To date, hypothermic machine perfusion (HMP) has become standard care in many centres preserving deceased donor kidneys. Despite a significant reduction of metabolism at low temperatures, remaining cellular activity in the organ still requires oxygen. However, oxygen supply during HMP is not standard yet, as its role and safety has not been fully clarified yet. This study investigates the effect of administering oxygen during HMP on renal function in a clinically relevant porcine donation after circulatory death (DCD) model. Methods After 30 minutes of warm ischemia, porcine slaughterhouse kidneys were preserved for 24 hours by means of static cold storage (CS), or HMP with Belzer Machine Perfusion Solution (UW- MPS) with the addition of 0%, 21% or 100% oxygen. Next, kidneys were reperfused for 4 hours in a normothermic autologous leukocyte depleted blood machine perfusion (NMP) setup. Kidneys were assessed on their renal function, oxidative stress and injury markers. Results HMP resulted in significantly better kidney function during NMP in terms of creatinine clearance, fractional sodium excretion and proteinuria. The addition of 100% oxygen showed the highest creatinine clearance, but did not reach statistical significance. TBARS, markers of oxidative stress, were negligibly low in all preservation modalities. Urinary TBARS at the end of NMP were highest in the CS group with a mean of 11.2 &mgr;M compared to 7.7 &mgr;M in the 100% oxygen group (NS). HMP preserved kidneys showed significantly lower injury markers compared with those preserved by CS. No such differences were found between the HMP groups with different oxygen concentrations. Conclusion This study demonstrated that kidney preservation with HMP is superior to CS. Although the addition of oxygen to HMP did not result in significantly improved renal function during NMP, beneficial effects were found in terms of reduced oxidative stress. Oxygen addition during HMP did not result in detrimental effects in this model
The vascular network is a major target of ischemia-reperfusion, but has been poorly investigated in renal transplantation. The aim of this study was to characterize the remodeling of the renal vascular network that follows ischemia-reperfusion along with the most highly affected cortex section in a preclinical renal transplantation model. There were two experimental groups. The first was a grafted kidney group consisting of large white pigs for which the left kidney was harvested, cold flushed, preserved for 24 h in the University of Wisconsin's preservation solution, and then auto-transplanted (n = 5); the right kidney was removed to mimic the situation of human kidney transplantation. The second group (uni-nephrectomized kidney group) consisted of animals that underwent only right nephrectomy, but not left renal transplantation (n = 5). Three months after autotransplantation, the kidneys were studied by X-ray microcomputed tomography. Vessel morphology and density and tortuosity of the network were analyzed using a 3D image analysis method. Cortical blood flow was determined by laser doppler analysis and renal function and tissue injury assessed by plasma creatinine levels and histological analysis. Renal ischemia-reperfusion led to decreased vascular segment volume associated with fewer vessels of less than 30 μm, particularly in the inner cortex:0.79 ± 0.54% in grafted kidneys vs. 7.06 ± 1.44% in uni-nephrectomized kidneys, p < 0.05. Vessels showed higher connectivity throughout the cortex (the arborescence factor of the whole cortex was less in grafted than uni-nephrectomized kidneys 0.90 ± 0.04 vs. 1.07 ± 0.05, p < 0.05, with an increase in the number of bifurcations). Furthermore, cortical blood flow decreased early in kidney grafts and remained low three months after auto-transplantation. The decrease in microvasculature correlated with a deterioration of renal function, proteinuria, and tubular dysfunction, and was associated with the development of fibrous tissue. This work provides new evidence concerning the impact of ischemia-reperfusion injuries on the spectrum of renal vascular diseases and could potentially guide future therapy to preserve microvessels in transplantation ischemia-reperfusion injury.