Point of care ultrasound (PoCUS) with pocket-size devices is an efficient and safe imaging modality that became a standard of care in various clinical settings. However, its implementation in hematology has never been evaluated so far. We conducted a prospective monocentric study aiming to harvest data on its usage and to assess its diagnostic and interventional performance in improving the accuracy of basic physical examination in hematological patients. After a focused training program, six hematologists were trained and conducted this study. Sixty-two patients were included. Only in 19 cases, further specialized imaging was required, whereas, in 43 patients PoCUS was sufficient to address the clinical inquiries. The use of PoCUS devices was assessed for its performance difficulty and usefulness perception with satisfactory outcomes. This study represents a proof-of-concept application of PoCUS in hematology, suggesting benefits over the physical examination.KEY POINTSPoCUS is particularly attractive in a hematological setting because able to improve the accuracy of physical examination.A hematology-focused training in PoCUS using handheld devices can allow hematologists to perform bed-side diagnostic and interventional US-based exams.
Significant morbidity and mortality have been associated with liver complications after allogeneic hematopoietic stem cell transplantation (allo-HSCT). Causes and consequences of these hepato-biliary complications are various and might be life-threatening. A high misdiagnosis rate has been reported because of a weak correlation between clinical, laboratory and imaging data. Liver elastography, a liver stiffness measure, is able to assess liver fibrosis and portal hypertension in most liver diseases, but data after allo-HSCT are scarce. Our aim was to determine the interest of sequential liver stiffness measurements for the diagnosis of early hepatic complications after allo-HSCT. Over a two years period of time, 161 consecutive adult patients were included and 146 were analyzed. Ultrasonography and elastography measurements were performed before transplantation, at day+7 and day+14 by three different experienced radiologists unaware of patients'clinical status. Eighty-one (55%) patients had liver involvements within the first 100 days after allo-HSCT. Baseline elastography was not predictive for the occurrence of overall liver abnormalities. A significant increase in 2D real-time shearwave elastography (2D-SWE) was found in patients with sinusoidal obstruction syndrome (SOS). Fifteen patients (10%) fulfilled EBMT score criteria and twelve (8%) reached Baltimore criteria for SOS diagnosis, but only six (4%) had a confirmed SOS. 2D-SWE at day+14 allowed early detection of SOS (AUROC=0.84, p=0.004) and improved sensibility (75%), specificity (99%) and positive predictive value (60%) over the Seattle, Baltimore or EBMT scores. A 2D-SWE measurement above 8.1kPa at day+14 after allo-HSCT seems a promising, non-invasive, and reproducible tool for early and accurate diagnosis of SOS.
BACKGROUND:Ultrasound (US) has been a regular practice in emergency departments for several decades. Thus, train our students to US is of prime interest. Because US image acquisition ability can be very different from a patient to another (depending on image quality), it seems relevant to adapt US learning curves (LCs) to patient image quality using tools based on cumulative summation (CUSUM) as the risk-adjusted LC CUSUM (RLC).OBJECTIVES:The aim of this study was to monitor LC of medical students for the acquisition of abdominal emergency US views and to adapt these curves to patient image quality using RLC.METHODS:We asked medical students to perform abdominal US examinations with the acquisition of 11 views of interest on emergency patients after a learning session. Emergency physicians reviewed the student examinations for validation. LCs were plotted and the student was said proficient for a specific view if his LC reached a predetermined limit fixed by simulation.RESULTS:Seven students with no previous experience in US were enrolled. They performed 19 to 50 examinations of 11 views each. They achieve proficiency for a median of 9 (6-10) views. Aorta and right pleura views were validated by seven students; inferior vena cava, right kidney, and bladder by six; gallbladder and left kidney by five; portal veins and portal hilum by four; and subxyphoid and left pleura by three. The number of US examinations required to reach proficiency ranged from five to 41 depending on the student and on the type of view. LC showed that students reached proficiency with different learning speeds.CONCLUSIONS:This study suggests that, when monitoring LCs for abdominal emergency US, there is some heterogeneity in the learning process depending on the student skills and the type of view. Therefore, rules based on a predetermined number of examinations to reach proficiency are not satisfactory.
BACKGROUND:Thyroid surgery is common, but complications may occur. High-intensity focused ultrasound (HIFU) is a minimally invasive alternative to surgery. We hypothesized that an optimized HIFU device could be safe and effective for ablating benign thyroid nodules without affecting neighboring structures.METHODS:In this open, single-center feasibility study, 25 patients were treated with HIFU with real-time ultrasound imaging 2 weeks before a scheduled thyroidectomy for multinodular goiter. Thyroid ultrasonography imaging, thyroid function, were evaluated before and after treatment. Adverse events were carefully recorded. Each patient received HIFU for one thyroid nodule, solid or mixed, with mean diameter ≥8 mm, and no suspicion of malignancy. The HIFU device was progressively adjusted with stepwise testing. The energy level for ablation ranged from 35 to 94 J/pulse for different groups of patients. One pathologist examined all removed thyroids.RESULTS:Three patients discontinued treatment due to pain or skin microblister. Among the remaining 22 patients, 16 showed significant changes by ultrasound. Macroscopic and histological examinations showed that all lesions were confined to the targeted nodule without affecting neighboring structures. At pathological analysis, the extent of nodule destruction ranged from 2% to 80%. Five out of 22 patients had over 20% pathological lesions unmistakably attributed to HIFU. Seventeen cases had putative lesions including nonspecific necrosis, hemorrhage, nodule detachment, cavitations, and cysts. Among these 17 cases, 12 had both ultrasound changes and cavitation at histology that may be expected for an HIFU effect. In the last three patients ablated at the highest energy level, significant ultrasound changes and complete coagulative necrosis were observed in 80%, 78%, and 58% of the targeted area, respectively. There were no major complications of ablation.CONCLUSION:This study showed the potential efficacy of HIFU for human thyroid nodule ablation. Lesions were clearly visible by histology and ultrasound after high energy treatments, and safety and tolerability were good. We identified a power threshold for optimal necrosis of the target thyroid tissue. Further studies are ongoing to assess nodule changes at longer follow-up times.
OBJECTIVE We describe a coaxial introducer provided with an additional blunt-tip stylet that allows safe access to difficult-to-reach lymph nodes in the chest, abdomen, and pelvis under CT control. CONCLUSION Once the thoracic, abdominal, or pelvic wall is crossed by the introducer fitted with the sharp-tip stylet, the blunt-tip stylet replaces the sharp stylet for further progression in the fat toward the target. The soft-tip stylet carries a smaller risk of inadvertent perforation displacing vital structures.
A 42-year-old man presented with a bullous rash of the fingers associated with numerous small milia and malar hypertrichosis. He had a past history of intravenous heroin abuse and of chronic alcoholism. The diagnosis of acquired porphyria cutanea tarda was confirmed by an increased urinary excretion of uroporphyrin. The laboratory tests showed erythrocyte macrocytosis and abnormal serum liver tests (ALAT 131 UI/l; ASAT 73 UI/l; gamma glutamyl transferase, 233 UI/l). Hepatitis C infection with positive HCV-RNA and genotype 1b was found. Abdominal ultrasound showed parenchymal multiple hyperechoic nodules with a marked peripheral hyperechoic rim throughout the liver. These nodules measured about 1 cm and had no mass effect on vascular structures (Fig. 1). The CT-scan (Fig. 2) showed hypodense nodules with central enhancement after iodine contrast injection equivalent to that of the uninvolved liver. On T1-weighted sequences, the MRI scan showed a homogeneous liver, and after intravenous gadolinium injection it showed hyperintense nodular lesions. On T2-weighted sequences, it showed slight hyperintense nodular lesions with a hyperintense millimetric central zone. A percutaneous liver biopsy of a liver nodule was performed under sonographic control and showed mild chronically active hepatitis (METAVIR score A1F1) associated with hemosiderosis and macrovacuolar steatosis. This was consistent with the diagnosis of multinodular focal fatty infiltration of the liver as reported before (1). The patient was treated with phlebotomy and was advised to stop alcohol ingestion.