Semen identification in forensic samples using prostate-specific antigen (PSA) overcomes limitations of conventional methods such as UV illumination and spermatozoa detection. In this study, we describe an antibody microarray for the quantitative immunochemical detection of PSA in forensic samples using 3D oxygen plasma-nanotextured polymer-coated glass slides. The analytical performance of these substrates was compared with that of silane-modified glass slides and demonstrated improved intra- and inter-spot homogeneity, as well as an extended linear dynamic range. Based on the 3D nanotextured slides, a two-step non-competitive immunoassay was developed using a biotinylated anti-PSA antibody and Alexa Fluor 546-labeled streptavidin for fluorescence detection. The assay was completed within 1 h, achieved a detection limit of 0.05 ng/mL PSA, and enabled semen detection at dilutions of up to 2 × 106. Incorporation of biotinylated bovine serum albumin spots as internal positive controls reduced slide-to-slide fluorescence variability, allowing cost-effective analysis of 24 samples per slide. The method was successfully applied to the detection of semen stains on spiked swabs and textile substrates of different compositions following a 1 h extraction step, demonstrating its suitability for rapid semen detection in forensic casework.
Milk can be contaminated with pathogenic bacteria such as Salmonella typhimurium and Escherichia coli, which can cause acute foodborne illnesses. In this study, we present an optical immunosensor designed for the simultaneous detection of these two bacteria in milk samples. The sensor is based on a silicon chip that incorporates two U-shaped silicon nitride waveguides configured as Mach-Zehnder Interferometers (MZIs). The sensing windows of the MZIs, located at one end of the chip, differ in length and allow for sequential immersion into reagent solutions during assay procedures. At the opposite end, the chip is optically coupled to a broadband white LED and a spectrophotometer via a bifurcated optical fiber and a dedicated coupler. To enable selective detection, the sensing windows of the MZIs are functionalized with lipopolysaccharides from the outer membranes of S. typhimurium and E. coli, respectively. A competitive immunoassay, completed in just 15 min, enabled detection limits of 45 cfu/mL for S. typhimurium and 125 cfu/mL for E. coli in milk. With a pre-enrichment step of approximately 8 h, single-cell detection became possible for both bacteria. The sensor excellent performance, quantitative determinations capability, and compact design, achieved by eliminating the need for microfluidics or pumps, make it a powerful and practical tool for bacterial detection in milk.
Carbyne-containing materials offer significant potential for biosensor applications due to their unique chemical and mechanical properties. In this study, carbyne-enriched carbon coatings deposited on SiO2/Si chips using ion-assisted pulse-plasma deposition were evaluated for the first time as substrates for optical biosensing. At first, the carbyne-enriched coatings were characterized by X-ray photoelectron spectroscopy, Raman spectroscopy, Atomic Force Microscopy, and the sessile drop method to assess their composition, structure, and wettability. After that, chips with carbyne-enriched coatings were modified with biomolecules through physical absorption or covalent bonding, and the respective biomolecular interactions were monitored in real-time by White Light Reflectance Spectroscopy (WLRS). In both cases, SiO2/Si chips modified with an aminosilane were used as reference substrates. Physical adsorption was tested through immobilization of an antibody against C-reactive protein (CRP) to enable its immunochemical detection, whereas covalent bonding was tested through coupling of biotin and monitoring its reaction with streptavidin. It was found that the carbyne-enriched carbon-coated chips retained both their antibody adsorption capability and their covalent bonding ability for over 18 months, while the modified with aminosilane SiO2/Si chips lost 90% of their antibody adsorption capacity and covalent bonding ability after two months of storage. These findings highlight the strong potential of carbyne-enriched carbon-coated chips as robust biosensing substrates, with applications extending beyond WLRS.
Aflatoxin M1 (AFM1) appears in the milk of animals that have consumed feed contaminated with aflatoxin B1. AFM1 presence in milk is regulated by the European Commission, which has set the maximum allowable limits for adult and infant consumption to 50 and 25 pg/mL, respectively. Here, a rapid and sensitive method for detecting AFM1 in milk based on an immersible silicon photonic chip is presented. The chip features two U-shaped silicon nitride waveguides formed as Mach–Zehnder interferometers. One interferometer is functionalized with AFM1–bovine serum albumin conjugate and the other with BSA to serve as a blank. The chip is connected to a broad-band white LED and a spectrophotometer by a bifurcated optical fiber and an assay is performed by immersing the chip in a mixture of milk with the anti-AFM1 antibody. Then, the chip is sequentially immersed in biotinylated anti-rabbit IgG antibody and streptavidin solutions for signal enhancement. The assay is completed in 20 min and the detection limit for AFM1 in undiluted milk is 20 pg/mL. Given its analytical performance and the absence of pumps and fluidics that lead to a compact instrument design, the proposed immunosensor is ideal for the on-site detection of AFM1 in milk samples.
Rapid and sensitive methods to detect allergenic proteins in foods at the point-of-need could help to protect allergic consumers from life-threatening accidental exposure. In this context, the development of a label-free optical immunosensor for detecting hazelnut proteins in cookies is presented. The sensor is based on silicon photonic chips containing two integrated Mach-Zehnder interferometers (MZI) with light input and output on one side of the chip, and sensing window openings on the other side. Coupling with a white-light LED and a spectrometer for signal recording is achieved via a bifurcated fiber. The sensing window of one of the MZIs is modified with a mouse monoclonal antibody against hazelnut proteins, while the other sensing window is modified with bovine serum albumin to serve as blank. The assay follows a two-step sandwich immunoassay format, involving a 10-min reaction with the hazelnut proteins calibrator or cookie sample, followed by a 2-min reaction with a mixture of monoclonal antibodies. All reactions were performed by immersing the chip side where the MZIs windows are located into the solutions. The recorded spectrum is processed in real-time to transform the spectrum shifts due to immunoreactions taking place on the sensing windows of the two MZIs into phase shifts. The developed assay detects hazelnut proteins at concentrations as low as 25 ng/mL in calibrators prepared in buffer or in aqueous extract of hazelnut-free cookies. Additionally, cookies containing hazelnuts were analyzed demonstrating the sensor ability for fast and sensitive detection of the hazelnut proteins in commercial products.
Legionella pneumophila has been pinpointed by the World Health Organization as the highest health burden of all waterborne pathogens in the European Union and is responsible for many disease outbreaks around the globe. Today, standard analysis methods (based on bacteria culturing onto agar plates) need several days (~12) in specialized analytical laboratories to yield results, not allowing for timely actions to prevent outbreaks. Over the last decades, great efforts have been made to develop more efficient waterborne pathogen diagnostics and faster analysis methods, requiring further advancement of microfluidics and sensors for simple, rapid, accurate, inexpensive, real-time, and on-site methods. Herein, a lab-on-a-chip device integrating sample preparation by accommodating bacteria capture, lysis, and DNA isothermal amplification with fast (less than 3 h) and highly sensitive, colorimetric end-point detection of L. pneumophila in water samples is presented, for use at the point of need. The method is based on the selective capture of viable bacteria on on-chip-immobilized and -lyophilized antibodies, lysis, the loop-mediated amplification (LAMP) of DNA, and end-point detection by a color change, observable by the naked eye and semiquantified by computational image analysis. Competitive advantages are demonstrated, such as low reagent consumption, portability and disposability, color change, storage at RT, and compliance with current legislation.
Survivin belongs to a family of proteins that promote cellular proliferation and inhibit cellular apoptosis. Its overexpression in various cancer types has led to its recognition as an important marker for cancer diagnosis and treatment. In this work, we compare two approaches for the immunochemical detection of survivin through surface-enhanced fluorescence or Raman spectroscopy using surfaces with nanowires decorated with silver nanoparticles in the form of dendrites or aggregates as immunoassays substrates. In both substrates, a two-step non-competitive immunoassay was developed using a pair of specific monoclonal antibodies, one for detection and the other for capture. The detection antibody was biotinylated and combined with streptavidin labeled with rhodamine for the detection of surface-enhanced fluorescence, while, for the detection via Raman spectroscopy, streptavidin labeled with peroxidase was used and the signal was obtained after the application of 3,3′,5,5′-tetramethylbenzidine (TMB) precipitating substrate. It was found that the substrate with the silver dendrites provided higher fluorescence signal intensity compared to the substrate with the silver aggregates, while the opposite was observed for the Raman signal. Thus, the best substrate was used for each detection method. A detection limit of 12.5 pg/mL was achieved with both detection approaches along with a linear dynamic range up to 500 pg/mL, enabling survivin determination in human serum samples from both healthy and ovarian cancer patients for cancer diagnosis and monitoring purposes.
In this work, silicon nanowires were constructed by metal-assisted chemical etching and decorated with silver nanoparticles and used as substrates for the SERS determination of oxidative stress markers, namely glutathione, malondialdehyde and catalase. The assays were sensitive, with detection limits of 50 and 3.2 nM for glutathione and malondialdehyde, respectively, and 0.5 μg/mL for catalase, indicating the capability of the proposed substrates to be implemented for the determination of various oxidative stress markers.
Aflatoxin M1 (AFM1) is the hydroxylated form of Aflatoxin B1 (AFB1) and is expelled in the milk of both humans and animals following the consumption of AFB1-contaminated food. AFM1 has been categorized as a Group 1 carcinogen by the International Agency for Research on Cancer. Consequently, the European Commission has established a maximum allowable concentration of 50 pg/mL for AFM1 in dairy products and milk. Here, a rapid and sensitive approach for detecting AFM1 in bovine milk is presented. The analytical setup comprises a broad-band white LED, a spectrophotometer, and a silicon photonic probe, all interconnected by a bifurcated optical fiber [1]. Additionally, a laptop powers the system and facilitates signal monitoring through specialized software. The silicon photonic probe is equipped with two Mach–Zehnder interferometers: one functionalized with AFM1-bovine serum albumin conjugate, and the other with bovine serum albumin to serve as a blank. The analysis involves immersing the probe directly into a mixture of anti-AFM1 antibodies and the sample, followed by sequential immersion into biotinylated anti-rabbit IgG antibody and streptavidin solutions. The entire assay process takes 12 min, and the limit of detection in undiluted milk is 20 pg/mL, below the EU maximum allowable limit of 50 pg/mL. The assay demonstrates accuracy, with %recovery values ranging from 87.5 to 112%, and repeatability, with intra/inter-assay coefficients of variation below 7.6%. Given its analytical performance and compact instrumentation, the proposed immunosensor proves to be an ideal solution for precise on-site determination of AFM1 in milk samples.
Oxidative stress is defined by an imbalance between the generation of reactive oxygen species and the biological system’s ability to neutralize them. This condition is commonly linked to various pathological conditions [1]. Superoxide dismutase (SOD) is a widely used enzyme to assess oxidative stress, and various techniques have been developed for its detection in biological samples such as blood, urine, and saliva [2]. Surface-enhanced photoluminescence (PL) is a particularly sensitive method, offering minimal interference from the sample matrix [3]. In this work, silver nanostructured surfaces were implemented as substrates for the immunochemical determination of SOD in synthetic saliva through PL. The substrates were prepared using a single-step metal-assisted chemical etching method (MACE), resulting in the formation of silicon nanowires decorated with silver dendrites of approximately 1.5 μm in height [4]. For SOD detection, a three-step competitive immunoassay configuration was followed. Briefly, SOD was immobilized onto the substrates and then the functionalized substrates were incubated with mixtures of SOD with anti-SOD primary antibody, prepared either in assay buffer or synthetic saliva. Then, a solution of biotinylated anti-species specific antibody was added, followed by a reaction with streptavidin labelled with the fluorescent dye Rhodamine Red-X, and the signal was determined through an in-house developed optical set-up. The developed method presents similar or slightly lower sensitivity (detection limit 0.05 μg/mL) compared to the literature; however, it does not require labor-intensive sample pretreatment steps [5,6]. The aforementioned findings demonstrate the capability of the developed method to detect superoxide dismutase in natural saliva, in order to evaluate the oxidative stress status of an organism.
Optical biosensors could play a crucial role in food analysis, allowing for the highly sensitive and rapid detection of harmful substances at the point-of-need. Within the realm of optical biosensors, interferometric ones excel in their ability for multiplexing analysis and portability, enabling their use at the point-of-need. This review provides a thorough overview of optical interferometric biosensors, primarily focusing on developments during the last decade for the detection of various food contaminants. It covers optical techniques designed to enhance sensitivity and achieve portability through integration of various optical and non-optical components into a device along with the respective recognition elements. In summary, the review highlights the ongoing efforts to develop novel and robust optical interferometric systems and outlines the future trends to meet the demanding requirements for their application in the field of food safety.
Silicon chips that monolithically integrate ten Mach-Zehnder interferometers (MZIs), their respective broad-band optical sources, and spectral analyzers, as well as photodiode arrays that record the spectrally-resolved output signals of the ten MZIs, are exploited for the multiplexed immunochemical determination of allergens and mycotoxins. The monolithically integrated light sources emit light in the visible/infrared spectrum (530-950 nm), and thus the detection based on broad-band Mach-Zehnder interferometry provided information about changes in the refractive index on the transducer surface due to binding reactions across the entire spectrum, surpassing the limitations of traditional monochromatic interferometry. The assays were run using a portable automated reader incorporating the chip fluidic and electronic interfacing, a micropump for continuous fluid delivery, and control electronics combined with a software for real-time signal monitoring. The photonic chips and portable reader were applied for allergen detection in dairy industry rinsing waters and mycotoxin detection in beer samples. All analytes were determined through competitive immunoassays. For the multiplexed detection of three allergens (bovine kappa-casein, peanut protein, and gliadin), the respective proteins were immobilized onto the sensing windows of different MZIs on a single chip. For the detection of mycotoxins (fumonisin B1 and deoxynivalenol), the respective mycotoxin-protein conjugates were employed. In all cases, the reaction with mixtures of calibrators/samples and analyte-specific antibodies was followed by a reaction with appropriate secondary antibodies to enhance the signal and reduce the assay duration. The allergen assays were completed in 10 min with detection limits of 0.01, 0.25, and 0.05 mu g/mL for kappa-casein, peanut protein, and gliadin, respectively. The mycotoxin assays took 15 min with detection limits of 2.0 and 10 ng/mL for fumonisin B1 and deoxynivalenol, respectively, in beer samples. The results demonstrate the potential of the developed solution for the rapid and sensitive on-site multiplexed detection of targeted analytes.
The enhanced and direct immobilization of the enzyme horseradish peroxidase on poly(methyl methacrylate) (PMMA) microchannel surfaces to create a miniaturized enzymatic reactor for the biocatalytic oxidation of phenols is demonstrated. Enzyme immobilization occurs by physical adsorption after oxygen plasma treatment, which micro-nanotextures the PMMA surfaces. A five-fold enhancement in immobilized enzyme activity was observed, attributed to the increased surface area and, therefore, to a higher quantity of immobilized enzymes compared to an untreated PMMA surface. The enzymatic reaction yield reached 75% using a flow rate of 2.0 μL/min for the reaction mixture. Additionally, the developed microreactor was reused more than 16 times without affecting the enzymatic conversion yield. These results demonstrate the potential of microchannels with plasma micro/nanotextured surfaces for the rapid and facile fabrication of microfluidic enzymatic microreactors with enhanced catalytic activity and stability.
Oxidative stress refers to the overproduction of reactive oxygen species and is often associated with numerous pathological conditions. Superoxide dismutase (SOD) is a widely used enzyme for evaluating oxidative stress, with numerous methods being developed for its detection in biological specimens like blood, urine, and saliva. In this study, a simple metal-assisted chemical etching method was employed for the fabrication of nanostructured silicon surfaces decorated with either silver dendrites or silver aggregates. Those surfaces were used as substrates for the immunochemical determination of SOD in synthetic saliva through surface-enhanced Raman spectroscopy (SERS) and surface-enhanced fluorescence (SEF). The immunoassay was based on a 3-step competitive assay format, which included, after the immunoreaction with the specific anti-SOD antibody, a reaction with a biotinylated secondary antibody and streptavidin. Streptavidin labeled with peroxidase was used in combination with a precipitating tetramethylbenzidine substrate for detection through SERS, whereas for SEF measurements, streptavidin labeled with the fluorescent dye Rhodamine Red-X was utilized. Both immunoassays were sensitive, with a detection limit of 0.01 μg/mL and a linear dynamic range from 0.03 to 3.3 μg/mL, enabling the evaluation of the oxidative stress status of an organism.
The quality and authenticity of milk are of paramount importance. Cow milk is more allergenic and less nutritious than ewe, goat, or donkey milk, which are often adulterated with cow milk due to their seasonal availability and higher prices. In this work, a silicon photonic dipstick sensor accommodating two U-shaped Mach–Zehnder Interferometers (MZIs) was employed for the label-free detection of the adulteration of ewe, goat, and donkey milk with cow milk. One of the two MZIs of the chip was modified with bovine κ-casein, while the other was modified with bovine serum albumin to serve as a blank. All assay steps were performed by immersion of the chip side where the MZIs are positioned into the reagent solutions, leading to a photonic dipstick immunosensor. Thus, the chip was first immersed in a mixture of milk with anti-bovine κ-casein antibody and then in a secondary antibody solution for signal enhancement. A limit of detection of 0.05% v/v cow milk in ewe, goat, or donkey milk was achieved in 12 min using a 50-times diluted sample. This fast, sensitive, and simple assay, without the need for sample pre-processing, microfluidics, or pumps, makes the developed sensor ideal for the detection of milk adulteration at the point of need.
Aflatoxin M1 (AFM1) exposure through dairy products is associated with adverse health effects, including hepatotoxicity and carcinogenicity. Therefore, the AFM1 presence in milk and dairy products is strictly regulated. In this context, the current work focuses on the investigation of different competitive enzyme immunoassay configurations for the determination of AFM1 in milk with high sensitivity and short assay duration. Amongst the configurations tested, the one based on incubation of the anti-AFM1 specific antibody along with the calibrators/samples and a biotinylated conjugate of AFM1 with bovine serum albumin (BSA) in microwells coated with a secondary antibody provided a six-fold lower detection limit than the configuration involving immobilized AFM1-BSA conjugate and liquid phase antibody. The detection limit achieved was 5.0 pg/mL, with a dynamic range of up to 2.0 ng/mL. The assay was repeatable with intra- and inter-assay coefficients of variations lower than 3.2% and 6.5%, respectively, and accurate with recovery values from 87.5 to 108%. Moreover, the assay was completed in 1.5 h. The excellent analytical characteristics and short analysis time make the proposed assay suitable for use by the food industry. Furthermore, the proposed configuration could be employed to enhance the detection sensitivity of competitive immunoassays for other low-molecular-weight analytes.
Gonadotropin-releasing hormone (GnRH) is pivotal in regulating human reproduction and fertility through its specific receptors. Among these, gonadotropin-releasing hormone receptor type I (GnRHR I), which is a member of the G-protein-coupled receptor family, is expressed on the surface of both healthy and malignant cells. Its presence in cancer cells has positioned this receptor as a primary target for the development of novel anti-cancer agents. Moreover, the extensive regulatory functions of GnRH have underscored decapeptide as a prominent vehicle for targeted drug delivery, which is accomplished through the design of appropriate conjugates. On this basis, a rationally designed series of anthraquinone/mitoxantrone–GnRH conjugates (con1–con8) has been synthesized herein. Their in vitro binding affinities range from 0.06 to 3.42 nM, with six of them (con2–con7) demonstrating higher affinities for GnRH than the established drug leuprolide (0.64 nM). Among the mitoxantrone based GnRH conjugates, con3 and con7 show the highest affinities at 0.07 and 0.06 nM, respectively, while the disulfide bond present in the conjugates is found to be readily reduced by the thioredoxin (Trx) system. These findings are promising for further pharmacological evaluation of the synthesized conjugates with the prospect of performing future clinical studies.
The simultaneous determination of two inflammatory diseases biomarkers, namely procalcitonin (PCT) and interleukin-6 (IL-6), in human serum samples employing a Point-of-Care device based on Multi Area Reflectance Spectroscopy is presented. Dual-analyte detection was achieved using silicon chips with two silicon dioxide areas of different thickness, one functionalized with an antibody specific for PCT and the other with an antibody specific for IL-6. The assay included reaction of immobilized capture antibodies with mixtures of PCT and IL-6 calibrators with the biotinylated detection antibodies, streptavidin and biotinylated-BSA. The reader provided for the automated execution of the assay procedure, as well as for the collection and processing of the reflected light spectrum, the shift of which is correlated to analytes concentration in the sample. The assay was completed in 35 min and the detection limits for PCT and IL-6 were 2.0 and 0.01 ng/mL respectively. The dual-analyte assay was characterized by high reproducibility (the intra-and inter-assay coefficients of variation were less than 10% for both analytes) and accuracy (the percent recovery values ranged from 80 to 113% for both analytes). Moreover, the values determined for the two analytes in human serum samples with the assay developed were in good agreement with the values determined for the same samples by clinical laboratory methods. These results support the potential of the proposed biosensing device application for inflammatory biomarkers determination at the Point-of-Need.
Copper-free “click” chemistry on appropriately modified surfaces and photolithography were explored for site-directed immobilization of biomolecules. The surfaces were modified either with self-assembled monolayers of silanes or an epoxy resin and then used as they were or further modified through adsorption of rabbit gamma-globulins to increase their reactive amine-content. All surfaces were then reacted with a succinimidyl ester cyclooctyne derivative and the efficiency of each modification approach was determined through click reaction with an azide derivative of fluorescein. It was found that the highest fluorescence signal was provided by the surface that had been modified with the epoxy resin and then coated with rabbit gamma-globulins. Surfaces prepared following the different modification procedures have been analyzed with ToF-SIMS to gain insight into the chemical changes of the surfaces after each step of the modification procedure. Analysis of intensities of characteristic ions signals confirmed the successful outcome of click reaction following the proposed surface modification approach. In addition, the ability to define through photolithography areas for site-directed immobilization of biomolecules onto surfaces modified with the succinimidyl ester cyclooctyne derivative was demonstrated through the creation of two molecules patterns.
Immunosensors that combine planar transducers with microfluidics to achieve in-flow biofunctionalization and assay were analyzed here regarding surface binding capacity, immobilization stability, binding stoichiometry, and amount and orientation of surface-bound IgG antibodies. Two IgG immobilization schemes, by physical adsorption [3-aminopropyltriethoxysilane (APTES)] and glutaraldehyde covalent coupling (APTES/GA), followed by blocking with bovine serum albumin (BSA) and streptavidin (STR) capture, are monitored with white light reflectance spectroscopy (WLRS) sensors as thickness dΓ of the adlayer formed on top of aminosilanized silicon chips. Multi-protein surface composition (IgG, BSA, and STR) is determined by time of flight secondary ion mass spectrometry (TOF-SIMS) combined with principal component analysis (applying barycentric coordinates to the score plot). In-flow immobilization shows at least 1.7 times higher surface binding capacity than static adsorption. In contrast to physical immobilization, which is unstable during blocking with BSA, chemisorbed antibodies desorb (reducing dΓ) only when the bilayer is formed. Also, TOF-SIMS data show that IgG molecules are partially exchanged with BSA on APTES but not on APTES/GA modified chips. This is confirmed by the WLRS data that show different binding stoichiometry between the two immobilization schemes for the direct binding IgG/anti-IgG assay. The identical binding stoichiometry for STR capture results from partial replacement with BSA of vertically aligned antibodies on APTES, with fraction of exposed Fab domains higher than on APTES/GA.