The treatment of critically ill patients has made great strides in the past few decades due to the rapid development of indwelling medical devices. Despite immense advancements in the design of these devices, indwelling medical device-associated infections and thrombosis are two major clinical problems that may lead to device failure and compromise clinical outcomes. Antibiotics are the current treatment choice for these infections; however, the global emergence of antibiotic-resistance and their biofilm formation abilities complicate the management of such infections. Moreover, systemic administration of anticoagulants has been used to counter medical device-induced thrombosis, but a range of serious adverse effects associated with all types of available anticoagulants entails exploring alternative options to counter device-associated thrombosis. In this study, bacteriophages (phages) were covalently immobilized on polydimethylsiloxane (PDMS) surface containing the nitric oxide (NO) donor S-nitroso-N-acetylpenicillamine (SNAP) via SNAP impregnation method. This dual strategy combines the targeted antibacterial activity of phages against bacterial pathogens with the antibacterial-antithrombotic activity of NO released from the polymeric surface. The PDMS, SNAP-PDMS, phage-immobilized PDMS (PDMS-Phage), and phage-immobilized SNAP-PDMS (SNAP-PDMS-Phage) surfaces were characterized for their surface topology, elemental composition, contact angle, SNAP loading, NO release and phage distribution. SNAP-PDMS and SNAP-PDMS-Phage surfaces showed similar and consistent NO release profiles over 24 h of incubation. Immobilization of whole phages on PDMS and SNAP-PDMS was achieved with densities of 2.4 +/- 0.54 and 2.1 +/- 0.33 phages mu m-2, respectively. Immobilized phages were found to retain their activity, and SNAP-PDMS-Phage surfaces showed a significant reduction in planktonic (99.99 +/- 0.08%) as well as adhered (99.80 +/- 0.05%) Escherichia coli as compared to controls in log killing assays. The SNAP-PDMS-Phage surfaces also exhibited significantly reduced platelet adhesion by 64.65 +/- 2.95% as compared to control PDMS surfaces. All fabricated surfaces were found to be nonhemolytic and do not exhibit any significant cytotoxic effects toward mammalian fibroblast cells. This study is the first of its kind to demonstrate the combinatorial pertinence of phages and NO to prevent antibiotic-resistant/sensitive bacterial infections and thrombosis associated with indwelling medical devices.
Bacteria-associated infections and thrombus formation are the two major complications plaguing the application of blood-contacting medical devices. Therefore, functionalized surfaces and drug delivery for passive and active antifouling strategies have been employed. Herein, we report the novel integration of bio-inspired superhydrophobicity with nitric oxide release to obtain a functional polymeric material with anti-thrombogenic and antimicrobial characteristics. The nitric oxide release acts as an antimicrobial agent and platelet inhibitor, while the superhydrophobic components prevent non-specific biofouling. Widely used medical-grade silicone rubber (SR) substrates that are known to be susceptible to biofilm and thrombus formation were dip-coated with fluorinated silicon dioxide (SiO2) and silver (Ag) nanoparticles (NPs) using an adhesive polymer as a binder. Thereafter, the resulting superhydrophobic (SH) SR substrates were impregnated with S-nitroso-N-acetylpenicillamine (SNAP, an NO donor) to obtain a superhydrophobic, Ag-bound, NO-releasing (SH-SiAgNO) surface. The SH-SiAgNO surfaces had the lowest amount of viable adhered E. coli (> 99.9 % reduction), S. aureus (> 99.8 % reduction), and platelets (> 96.1 % reduction) as compared to controls while demonstrating no cytotoxic effects on fibroblast cells. Thus, this innovative approach is the first to combine SNAP with an antifouling SH polymer surface that possesses the immense potential to minimize medical device-associated complications without using conventional systemic anticoagulation and antibiotic treatments.
Silicone rubber (SR), a common medical-grade polymer used in medical devices, has previously been modified for nitric oxide (NO) releasing capabilities. However, the effects of material properties such as film thickness on NO release kinetics are not well explored. In this study, SR is used in the first analysis of how a polymer's thickness affects the storage and uptake of an NO donor and subsequent release properties. Observed NO release trends show that a polymer's thickness results in tunable NO release. These results indicate how crucial a polymer's thickness is to optimize the NO release in an efficient and effective method. image
Hybrid organic-inorganic materials are attracting enormous interest in materials science due to the combination of multiple advantageous properties of both organic and inorganic components. Taking advantage of a simple, scalable, solvent-free hard-sacrificial method, we report the successful fabrication of three-dimensional hybrid porous foams by integrating two types of fillers into a poly(dimethylsiloxane) (PDMS) framework. These fillers consist of hydrophobic electrically conductive graphene (GR) nanoplatelets and hydrophobic bactericidal copper (Cu) microparticles. The fillers were utilized to create the hierarchical rough structure with low-surface-energy properties on the PDMS foam surfaces, leading to remarkable superhydrophobicity/superoleophilicity with contact angles of 158 and 0° for water and oil, respectively. The three-dimensional interconnected porous foam structures facilitated high oil adsorption capacity and excellent reusability as well as highly efficient oil/organic solvent-water separation in turbulent, corrosive, and saline environments. Moreover, the introduction of the fillers led to a significant improvement in the electrical conductivity and biofouling resistance (vs whole blood, fibrinogen, platelet cells, and Escherichia coli) of the foams. We envision that the developed composite strategy will pave a facile, scalable, and effective way for fabricating novel multifunctional hybrid materials with ideal properties that may find potential use in a broad range of biomedical, energy, and environmental applications.
Addressing thrombosis and biofouling of indwelling medical devices within healthcare institutions is an ongoing problem. In this work, two types of ultra-low fouling surfaces (i.e., superhydrophobic and lubricant-infused slippery surfaces) were fabricated to enhance the biocompatibility of commercial medical grade silicone rubber (SR) tubes that are widely used in clinical care. The superhydrophobic (SH) coatings on the tubing substrates were successfully created by dip-coating in superhydrophobic paints consisting of polydimethylsiloxane (PDMS), perfluorosilane-coated hydrophobic zinc oxide (ZnO) and copper (Cu) nanoparticles (NPs) in tetrahydrofuran (THF). The SH surfaces were converted to lubricant-infused slippery (LIS) surfaces through the infusion of silicone oil. The anti-biofouling properties of the coatings were investigated by adsorption of platelets, whole blood coagulation, and biofilm formation in vitro. The results revealed that the LIS tubes possess superior resistance to clot formation and platelet adhesion than uncoated and SH tubes. In addition, bacterial adhesion was investigated over 7 days in a drip-flow bioreactor, where the SH-ZnO-Cu tube and its slippery counterpart significantly reduced bacterial adhesion and biofilm formation of Escherichia coli relative to control tubes (>5 log(10) and >3 log(10) reduction, respectively). The coatings also demonstrated good compatibility with fibroblast cells. Therefore, the proposed coatings may find potential applications in high-efficiency on-demand prevention of biofilm and thrombosis formation on medical devices to improve their biocompatibility and reduce the risk of complications from medical devices. (C) 2021 Elsevier Inc. All rights reserved.
Numerous biomaterials have been developed for application in blood-contacting medical devices to prevent thrombosis; however, few materials have been applied to full-scale devices and evaluated for hemocompatibility under clinical blood flow conditions. We applied a dual-action slippery liquid-infused (LI) nitric oxide (NO)-releasing material modification (LINO) to full-scale blood circulation tubing for extracorporeal lung support and evaluated the tubing ex vivo using swine whole blood circulated for 6 h at a clinically relevant flow. LINO tubing was compared to unmodified tubing (CTRL) and isolated LI and NO-releasing modifications (n = 9/group). The primary objective was to evaluate safety and blood compatibility of this approach, prior to progression to in vivo testing of efficacy in animal models. The secondary objective was to evaluate coagulation outcomes relevant to hemocompatibility. No untoward effects of the coating, such as elevated methemoglobin fraction, were observed. Additionally, LINO delayed platelet loss until 6 h versus the reduction in platelet count in CTRL at 3 h. At 6 h, LINO significantly reduced the concentration of platelets in an activated P-selectin expressing state versus CTRL (32 ± 1% decrease, p = .02). Blood clot deposition was significantly reduced on LINO blood pumps (p = .007) and numerically reduced on tubing versus CTRL. Following blood exposure, LINO tubing continued to produce a measurable NO-flux (0.20 ± 0.06 × 10-10 mol cm-2 min-1 ). LINO is a potential solution to reduce circuit-related bleeding and clotting during extracorporeal organ support, pending future extended testing in vivo using full-scale extracorporeal lung support devices.
When blood first encounters the artificial surface of a medical device, a complex series of biochemical reactions is triggered, potentially resulting in clinical complications such as embolism/occlusion, inflammation, or device failure. Preventing thrombus formation on the surface of blood-contacting devices is crucial for maintaining device functionality and patient safety. As the number of patients reliant on blood-contacting devices continues to grow, minimizing the risk associated with these devices is vital towards lowering healthcare-associated morbidity and mortality. The current standard clinical practice primarily requires the systemic administration of anticoagulants such as heparin, which can result in serious complications such as post-operative bleeding and heparin-induced thrombocytopenia (HIT). Due to these complications, the administration of antithrombotic agents remains one of the leading causes of clinical drug-related deaths. To reduce the side effects spurred by systemic anticoagulation, researchers have been inspired by the hemocompatibility exhibited by natural phenomena, and thus have begun developing medical-grade surfaces which aim to exhibit total hemocompatibility via biomimicry. This review paper aims to address different bio-inspired surface modifications that increase hemocompatibility, discuss the limitations of each method, and explore the future direction for hemocompatible surface research.
Background: Numerous biomaterials are developed to mitigate untoward effects of blood exposure to foreign surfaces on blood-contacting medical devices, such as extracorporeal life support (ECLS); however, limited testing is performed using clinical blood flow conditions and device components. A liquid infused nitric oxide-releasing (LiNORel) material was developed to prevent surface protein adsorption while eluting nitric oxide (NO) to minimize platelet activation and aggregation. The study objective was to assess LiNORel applied to full-scale ECLS circuit tubing during 6 h ex vivo circulation of porcine blood at a clinically relevant flow rate. We hypothesized that LiNORel reduces thrombus deposition and platelet sequestration versus unmodified tubing. Methods: Heparinized blood (0.75 U/mL) was collected from mechanically ventilated swine (n=9, 45-55kg) with ARDS following polytrauma in an unrelated multi-day ICU study. Blood was divided into circuits with the following (500 mL/circuit): CTRL – unmodified tubing; LI – tubing with liquid infused surface modification; NO – tubing with NOrelease modification; LiNORel – tubing with liquid infused and NO-release modifications. Circuits included a blood reservoir, centrifugal pump, and 2 tubing segments (1 m, 3/8” ID). Circulation was performed for 6 h at 1.5 L/min flow rate. Heparin was sparingly administered to maintain activated clotting times (ACT) of 125-160s. Data included: heparin administered, blood gas, methemoglobin (MetHb) as an indicator of NO toxicity, pump revolutions per minute. At baseline, 3- and 6 h, a blood panel was performed to assess platelet count/activation, thromboelastography, PT, aPTT, fibrinogen, D-dimer, von Willebrand factor (vWF) activity and plasma free hemoglobin. Post-circulation thrombus deposition was analyzed. Data were analyzed for within-group time-dependent changes and between group differences. All tests were two-sided (p<0.05 for significance). Results: Circuits remained patent in all groups with ACT in range. Numerically (n.s.), CTRL received more heparin (100±49 U) to maintain ACT (NO=50±32 U, LI=33±27, LiNORel=47±33 U). There was no group difference in blood gases and MetHb. Numerically, reduction in platelet count at 6 h was greatest in CTRL and least in LiNORel (n.s., Fig 1A). Activated platelets were elevated at 6 h in CTRL vs NO (p=0.013) and LiNORel (p=0.020) (Fig 1B). Numerically, procoagulant platelets were elevated in CTRL (Fig 1C). No group differences in thromboelastography, PT, aPTT and fibrinogen were observed. D-dimer was elevated at 6 h in CTRL (p=0.007) and LI (p=0.027) groups. vWF was elevated at 6 h in CTRL (p=0.001). Clot deposition was minimal and not different between groups. Conclusions: LiNORel reduced platelet activation in this model which utilized a clinically relevant blood flow rate and full-scale circulation tubing for partial lung support. Additional testing in vivo for multi-day duration is ongoing in our laboratory. Figure 1. Platelet count (A), concentration of activated platelets indicated by expression of P-selectin (B) and concentration of procoagulant platelets indicated by phosphatidyl serine expression (C) during 6-hours ex vivo circulation. Circuit tubing consisted of Control (CTRL) – uncoated standard tubing; Nitric Oxide (NO) – tubing with embedded nitric oxide donor; Liquid Infused (LI) – tubing swelled with non-adhesive lubricant layer; Liquid-infused Nitric Oxide Release (LiNORel) – tubing with embedded nitric oxide donor and non-adhesive lubricant layer combination coating. †Indicates significant difference between LiNORel and CTRL. ‡Indicates significant difference between NO and CTRL. *Indicates significant difference within NO group from baseline (BL). **Indicates significant difference within CTRL group from BL. ***Indicates significant difference within LiNORel group from BL. ****Indicates significant difference within LI group from BL. All tests two-sided with p<0.05 for significance.
Hypothesis: Broad-spectrum antimicrobials are needed to mitigate the complicated nature of antibiotic resistant infections. It is imperative to formulate new antimicrobials by combining agents with different mechanisms and broader microbial targets. A combined antimicrobial solution could be a highly critical step towards developing a strategy to prevent polymicrobial infections. Herein, we have investigated the interaction and antimicrobial potential of a solution that contains cerium oxide nanoparticles (CNP) and a nitric oxide (NO) donor, S-nitroso-N-acetylpenicillamine (SNAP). It is hypothesized that these two agents induce synergistic effects and would provide broad antimicrobial effects since CNP is known to be an effective antifungal agent while NO released by SNAP is known to be a potent bactericidal agent. Experiments: Different concentrations of SNAP and CNP were combined in a solution and tested for colloidal stability, NO release, mammalian cell cytotoxicity, and antimicrobial efficacy against Staphylococcus aureus, Escherichia coli, and Candida albicans, accounting for Gram-positive bacteria, Gram-negative bacteria, and fungi, respectively. Findings: SNAP and CNP combined in equimolar solution of 3 mM were found to be highly virulent for all microbes tested compared to higher amounts of the treatments required individually. These results hold a promising outlook toward the development of broad-spectrum antimicrobial coatings and films with the potential to prevent polymicrobial infections and further enhance biomedical device usage and applications. (C) 2020 Elsevier Inc. All rights reserved.
Indwelling medical devices currently used to diagnose, monitor, and treat patients invariably suffer from two common clinical complications: broad-spectrum infections and device-induced thrombosis. Currently, infections are managed through antibiotic or antifungal treatment, but the emergence of antibiotic resistance, the formation of recalcitrant biofilms, and difficulty identifying culprit pathogens have made treatment increasingly challenging. Additionally, systemic anticoagulation has been used to manage device-induced thrombosis, but subsequent life-threatening bleeding events associated with all available therapies necessitates alternative solutions. In this study, a broad-spectrum antimicrobial, antithrombotic surface combining the incorporation of the nitric oxide (NO) donor S-nitroso-N-acetylpenicillamine (SNAP) with the immobilization of the antifungal Amphotericin B (AmB) on polydimethylsiloxane (PDMS) was developed in a two-step process. This novel strategy combines the key advantages of NO, a bactericidal agent and platelet inhibitor, with AmB, a potent antifungal agent. We demonstrated that SNAP-AmB surfaces significantly reduced the viability of adhered Staphylococcus aureus (99.0 ± 0.2%), Escherichia coli (89.7 ± 1.0%), and Candida albicans (93.5 ± 4.2%) compared to controls after 24 h of in vitro exposure. Moreover, SNAP-AmB surfaces reduced the number of platelets adhered by 74.6 ± 3.9% compared to controls after 2 h of in vitro porcine plasma exposure. Finally, a cytotoxicity assay validated that the materials did not present any cytotoxic side effects toward human fibroblast cells. This novel approach is the first to combine antifungal surface functionalization with NO-releasing technology, providing a promising step toward reducing the rate of broad-spectrum infection and thrombosis associated with indwelling medical devices.
The main challenge for biological engineering educators is that BE is a relatively new and broad discipline that integrates a diverse array of knowledge from the basic sciences and engineering sciences towards application in the biological and medicinal fields. Due to variety of possible career outcomes and limited department resources (money, laboratory space, etc.), it is not possible to create a single undergraduate curriculum that will cover all of the technical skills spanning the entire biological engineering field in a hands-on setting. As laboratory sections have been shown to provide a variety of educational benefits, it is imperative that university engineering departments seek alternative methods to deliver real-life application of classroom concepts.As such, interest in the development and usage of simulated lab sections has risen. While these lab experiences offer economic benefits to educational institutions and are more convenient for students to access, the exact educational outcomes of simulated labs, especially when compared to traditional hands-on labs, is still unclear. Due to the previously stated challenges, the biological engineering education community could benefit greatly by the implementation of simulated labs; however, there is a limited amount of literature on simulated labs in the context of biological engineering.Therefore, the purpose of this study is to provide a case study on how the implementation of a commercially available simulated lab alters the motivation of students in a BE course. Data collection will help us answer three research questions: 1) How well does the simulated lab intervention work? 2) How do BE students experience disciplinary-specific simulated labs? 3) How do those experiences inform us on the student motivation? By utilizing the MUSIC® Model of Academic Motivation, we aim to pin down the social realities surrounding simulated BE labs, clarify the unique motivations of BE students, and provide vital information for the national discourse of proper BE curricula development.
Biofilm and thrombus formation on surfaces results in significant morbidity and mortality worldwide, which highlights the importance of the development of efficacious fouling-prevention approaches. In this work, novel highly robust and superhydrophobic coatings with outstanding multiliquid repellency, bactericidal performance, and extremely low bacterial and blood adhesion are fabricated by a simple two-step dip-coating method. The coatings are prepared combining 1H,1H,2H,2H-perfluorooctyltriethoxysilane (FAS-17)-coated hydrophobic zinc oxide and copper nanoparticles to construct hierarchical micro/nanostructures on commercial polyurethane (PU) sponges followed by polydimethylsiloxane (PDMS) treatment that is used to improve the binding degree between the nanoparticles and the sponge surface. The micro/nanotextured samples can repel various liquids including water, milk, coffee, juice, and blood. Relative to the original PU, the superhydrophobic characteristics of the fabricated sponge cause a significant reduction in the adhesion of bacteria (Staphylococcus aureus) by up to 99.9% over a 4-day period in a continuous drip-flow bioreactor. The sponge is also highly resistant to the adhesion of fibrinogen and activated platelets with ∼76 and 64% reduction, respectively, hence reducing the risk of blood coagulation and thrombus formation. More importantly, the sponge can sustain its superhydrophobicity even after being subjected to different types of harsh mechanical damage such as finger-wiping, knife-scratching, tape-peeling, hand-kneading, hand-rubbing, bending, compress-release (1000 cycles) tests, and 1000 cm sandpaper abrasion under 250 g of loading. Hence, this novel hybrid surface with robustness and the ability to resist blood adhesion and bacterial contamination makes it an attractive candidate for use in diverse application areas.
Biomedical surface-associated infections and thrombus formation are two major clinical issues that challenge patient safety and patient the fate of a medical device in the body. Single platform multifunctional surfaces are critical to address both these indwelling medical device-related problems. In this work, bioinspired approaches are employed to fabricate a polymer composite with a versatile surface that can reduce bacterial infections and platelet adhesion in vitro. In the first bio-inspired approach, the functionality of nitric oxide (NO) produced by endothelial cell lining of blood vessels is mimicked through incorporation of S-nitroso-N-acetylpenicillamine (SNAP) within a CarboSil-2080A (TM) (CarboSil) polymer composite matrix. The second approach involves utilizing mussel adhesive chemistry, via polydopamine (PDA) to immobilize polytetrafluoroethylene (PTFE) particles on the polymer composite surface. The PTFE coating facilitates a decrease in wettability by making the polymer composite surface highly hydrophobic (contact angle ca. 120 degrees). The surface of the fabricated polymer composite, CarboSil SNAP-PTFE, had a cobblestone-like structured appearance as characterized through scanning electron microscopy (SEM). Water contact angle (WCA) and surface tension measurements indicated no significant coating losses after 24 h under physiological conditions. NO surface flux was measured and analyzed for 5 days using a chemiluminescence-based nitric oxide analyzer and was found to be within the physiological range. CarboSil SNAP-PTFE reduced adhered bacteria (99.3 +/- 0.5% for Gram-positive S. aureus and 99.1 +/- 0.4% for Gram-negative E. coli) in a 24 h in vitro study. SEM analysis showed the absence of biofilm formation on CarboSil SNAP-PTFE polymer composites, while present on CarboSil in 24 h exposure to S. aureus. Platelet adhesion was reduced by 83.3 +/- 4.5%. Overall, the results of this study suggest that a combination of NO-releasing CarboSil with PTFE coating can drastically reduce infection and platelet adhesion. (C) 2020 Elsevier Inc. All rights reserved.
In this study, the preparation and characterization of nitric oxide (NO) releasing silk fibroin nanoparticles (SF NPs) are described for the first time. S-Nitroso-N-acetylpenicillamine (SNAP)-loaded SF NPs (SNAP-SF NPs) were prepared via an antisolvent/self-assembling method by adding a SNAP/ethanol solution to an aqueous SF solution and freeze-thawing. The prepared SNAP-SF NPs had a diameter ranging from 300 to 400 nm and an overall negative charge of -28.76 ± 0.73 mV. Among the different SNAP/SF ratios tested, the highest encapsulation efficiency (18.3 ± 1.3%) and loading capacity (9.1 ± 0.6%) values were attributed to the 1:1 ratio. The deconvolution of the amide I band in the FTIR spectra of SF NPs and SNAP-SF NPs showed an increase in the β-sheet content for SNAP-SF NPs, confirming the hydrophobic interactions between SNAP and silk macromolecules. SNAP-SF NPs released up to 1.31 ± 0.02 × 10-10 mol min-1 mg-1 NO over a 24 h period. Moreover, SNAP-SF NPs showed concentration-dependent antibacterial effects against methicillin-resistant Staphylococcus aureus and Escherichia coli. Furthermore, they did not elicit any marked cytotoxicity against 3T3 mouse fibroblast cells at concentrations equal to or below 2 mg/mL. Overall, these results demonstrated that SNAP-SF NPs have great potential to be used as a NO delivery platform for biomedical applications such as tissue engineering and wound healing, where synergistic properties of SF and NO are desired.
The management of thrombosis and bacterial infection is critical to ensure the functionality of medical devices. While administration of anticoagulants is the current antithrombotic clinical practice, a variety of complications, such as uncontrolled hemorrhages or heparin-induced thrombocytopenia, can occur. Additionally, infection rates remain a costly and deadly complication associated with use of these medical devices. It has been hypothesized that if a synthetic surface could mimic the biochemical mechanisms of the endothelium of blood vessels, thrombosis could be reduced, anticoagulant use could be avoided, and infection could be prevented. Herein, the interfacial biochemical effects of the endothelium were mimicked by altering the surface of medical grade silicone rubber (SR). Surface modification was accomplished via heparin surface immobilization (Hep) and the inclusion of a nitric oxide (NO) donor into the SR polymeric matrix to achieve synergistic effects (Hep-NO-SR). An in vitro bacteria adhesion study revealed that Hep-NO-SR exhibited a 99.46 ± 0.17% reduction in viable bacteria adhesion compared to SR. An in vitro platelet study revealed Hep-NO-SR reduced platelet adhesion by 84.12 ± 6.19% compared to SR, while not generating a cytotoxic response against fibroblast cells. In a 4 h extracorporeal circuit model without systemic anticoagulation, all Hep-NO-SR samples were able to maintain baseline platelet count and device patency; whereas 66% of SR samples clotted within the first 2 h of study. Results indicate that Hep-NO-SR creates a more hemocompatible and antibacterial surface by mimicking two key biochemical functions of the native endothelium.
Devices used for extracorporeal circulation are met with two major medical concerns: thrombosis and infection. A device that allows for anticoagulant-free circulation while reducing risk of infection has yet to be developed. We report the use of a copper nanoparticle (Cu NP) catalyst for the release of nitric oxide (NO) from the endogenous donor S-nitrosoglutathione (GSNO) in a coating applied to commercial Tygon S3™ E-3603 poly(vinyl chloride) tubing in order to reduce adhered bacterial viability and the occurrence thrombosis for the first time in an animal model. Cu GSNO coated material demonstrated a nitric oxide (NO) release flux ranging from an initial flux of 6.3 ± 0.9 ×10-10 mol cm-2 min-1 to 7.1 ± 0.4 ×10-10 mol cm-2 min-1 after 4 h of release, while GSNO loops without Cu NPs only ranged from an initial flux of 1.1 ± 0.2 ×10-10 mol cm-2 min-1 to 2.3 ± 0.2 ×10-10 mol cm-2 min-1 after 4 h of release, indicating that the addition of Cu NPs can increase NO flux up to five times in the same 4 h period. Additionally, a 3-log reduction in S. aureus and 1-log reduction in P. aeruginosa was observed in viable bacterial adhesion over a 24 h period compared to control loops. A Cell Counting Kit-8 (CCK-8) assay was used to validate no overall cytotoxicity towards 3T3 mouse fibroblasts. Finally, extracorporeal circuits were coated and exposed to 4 h of blood flow under an in vivo rabbit model. The Cu GSNO combination was successful in maintaining 89.3% of baseline platelet counts, while the control loops were able to maintain 67.6% of the baseline. These results suggest that the combination of Cu NPs with GSNO increases hemocompatibility and antimicrobial properties of ECC loops without any cytotoxic effects towards mammalian cells.
In medical device design, there is a vital need for a coating that promotes treatment of the patient and simultaneously prevents fouling by biomacromolecules which in turn can progress to infections, thrombosis, and other device-related complications. In this work, hydrophobin SC3 (SC3), a self-assembling amphiphilic protein, was coated on a nitric oxide (NO) releasing medical grade polymer to provide an antifouling layer to work synergistically with NO's bactericidal and antiplatelet activity (SC3-NO). The contact angle of SC3 samples were ∼30% lesser than uncoated control samples and was maintained for a month in physiological conditions, demonstrating a stable, hydrophilic coating. NO release characteristics were not adversely affected by the SC3 coating and samples with SC3 coating maintained NO release. Fibrinogen adsorption was reduced over tenfold on SC3 coated samples when compared to non-SC3 coated samples. The viable cell count of adhered bacteria (Staphylococcus aureus) on SC3-NO was 79.097 ± 7.529% lesser than control samples and 49.533 ± 18.18% lesser than NO samples. Platelet adherence on SC3-NO was reduced by 73.407 ± 14.59% when compared to control samples and 53.202 ± 25.67 when compared to NO samples. Finally, the cytocompatibility of SC3-NO was tested and proved to be safe and not trigger a cytotoxic response. The overall favorable results from the physical, chemical and biological characterization analyses demonstrate the novelty and importance of a naturally-produced antifouling layer coated on a bactericidal and antiplatelet polymer, and thus will prove to be advantageous in a multitude of medical device applications.