Measuring wireless devices in a reverberation chamber often requires ancillary equipment to be present in the chamber. This paper illustrates the effect of their presence on metrics that are important in wireless device tests, such as chamber decay time, coherence bandwidth, and antenna efficiency calculations. The results show decreases in chamber decay time of approximately 20 % when power supplies and power cords are present in the NIST chamber. For the chamber studied, the effect is approximately 10 % with a regular power cord, demonstrated to be mostly caused by the copper conductors through measurements and a model of the cord insulation. The effect on antenna efficiency by using a predetermined time constant is shown to be between 5 % and 10 % for different setups. Results from two reverberation chambers are presented, showing lower percentages for a chamber with higher losses.
In recent years several ways to radiometrically calibrate optical fiber-coupled detectors have been developed. However, fiber-coupled calibration methods for single photon detectors have not been compared by national metrology institutes in order to validate their equivalence or traceability to the international systems of units yet.. Here, we present the comparison of radiometric calibration methods traceable to a NIST cryogenic radiometer at the 'few-photon' level. The calibration methods are based on metrology grade optical power meters. The expanded (k = 2) relative standard uncertainties of the calibration methods for the detection efficiency are of the order of 0.5%. However, the results changed relatively by 10% with a different set of optical fibers and mating connectors. These results stress the importance of fiber-core dimensions and fiber-connector repeatability.
We experimentally studied the dynamics of optically excited hotspots in current carrying WSi superconducting nanowires as a function of bias current, bath temperature and excitation wavelength. We discovered that: (1) the hotspot relaxation is a factor of ~ 4 slower in WSi than in NbN; (2) the hotspot relaxation time depends on bias current, and (3) the current dependence of the hotspot relaxation time changes with temperature and wavelength. We explained all of these effects with a model based on quasi particle recombination.
We demonstrate a 64-pixel free-space-coupled array of superconducting nanowire single photon detectors optimized for high detection efficiency in the near-infrared range. An integrated, readily scalable, multiplexed readout scheme is employed to reduce the number of readout lines to 16. The cryogenic, optical, and electronic packaging to read out the array, as well as characterization measurements are discussed.
The application of cryogenic microcalorimeter detectors to γ-ray spectroscopy allows for measurements with unprecedented energy resolution. These detectors are ideally suited for γ-ray spectroscopy applications for which the measurement quality is limited by the spectral overlap of many closely spaced transitions using conventional detector technologies. The non-destructive analysis of mixed-isotope Pu materials is one such application where the precision can be potentially improved utilizing microcalorimeter detectors compared to current state-of-the-art high-purity Ge detectors (HPGe). The LANL-NIST γ-ray spectrometer, a 256-pixel microcalorimeter array based on transition-edge sensors (TESs), was recently commissioned and used to collect data on a variety of Pu isotopic standards to characterize the instrument performance. These measurements represent the first time the simultaneous readout of all 256 pixels for measurements of mixed-isotope Pu materials has been achieved. The LANL-NIST γ-ray spectrometer has demonstrated an average pixel resolution of 55eV full-width-at-half-maximum at 100keV, nearly an order of magnitude better than HPGe detectors. Some challenges of the analysis of many-channel ultra-high resolution data and the techniques used to produce quality spectra for isotopic analysis will be presented. The LANL-NIST γ-ray spectrometer has also demonstrated stable operation and obtained high resolution measurements at total array event rates beyond 1kHz. For a total event rate of 1.25kHz, approximately 5.6cps/pixel, a 72.2eV average FWHM for the 103keV photopeak of 153Gd was achieved.
We demonstrate a 64-pixel free-space-coupled array of superconducting nanowire single photon detectors optimized for high detection efficiency in the near-infrared range. An integrated, readily scalable, multiplexed readout scheme is employed to reduce the number of readout lines to 16. The cryogenic, optical, and electronic packaging to read out the array as well as characterization measurements are discussed.
We report on MoSi SNSPDs which achieved high system detection efficiency (87.1 ± 0.5% at 1542 nm) at 0.7 K and we demonstrate that these detectors can also be operated with saturated internal efficiency at a temperature of 2.3 K in a Gifford-McMahon cryocooler. We measured a minimum system jitter of 76 ps, maximum count rate approaching 10 MHz, and polarization dependence as low as 3.3 ± 0.1%. The performance of MoSi SNSPDs at 2.3 K is similar to the performance of WSi SNSPDs at < 1 K. The higher operating temperature of MoSi SNSPDs makes these devices promising for widespread use due to the simpler and less expensive cryogenics required for their operation.
Superconducting nanowire single-photon detectors (SNSPDs) based on ultra-thin films have become the preferred technology for applications that require high efficiency single-photon detectors with high speed, high timing resolution, and low dark count rates at near-infrared wavelengths. Since demonstration of the first SNSPD using NbN thin films, an increasingly larger number of materials are being explored. We investigate amorphous thin film alloys of MoSi, MoGe, and WRe with the goal of optimizing SNSPDs for higher operating temperature, high efficiency and high speed. To explore material adequacy for SNSPDs, we have measured superconducting transition temperature (Tc) as a function of film thickness and sheet resistance, as well as critical current densities. In this paper we present our results comparing these materials to WSi, another amorphous material widely used for SNSPD devices.
We describe our progress towards building a free-space coupled array of nanowire detectors with a multiplexed readout. The cryogenic, optical, and electronic packaging to readout the array will be discussed.
We demonstrate a scalable readout scheme for an infrared single-photon pulse-position camera consisting of WSi superconducting nanowire single-photon detectors. For an N × N array, only 2 × N wires are required to obtain the position of a detection event. As a proof-of-principle, we show results from a 2 × 2 array.
We investigate the operation of WSi superconducting nanowire single-photon detectors (SNSPDs) at 2.5 K, a temperature which is ∼70% of the superconducting transition temperature (TC) of 3.4 K. We demonstrate saturation of the system detection efficiency at 78 ± 2% at a wavelength of 1310 nm, with a jitter of 191 ps. We find that the jitter at 2.5 K is limited by the noise of the readout and can be improved through the use of cryogenic amplifiers. Operation of SNSPDs with high efficiency at temperatures very close to TC appears to be a unique property of amorphous WSi.
We measured the temporal dynamics of optically excited hotspots in current-carrying WSi superconducting nanowires as a function of bias current, temperature and excitation wavelength, observing an unexpected effect: hotspot relaxation depends strongly on bias current.
The total reaction energy (Q) of individual nuclear decays was measured using microcalorimeters with transition-edge-sensor (TES) thermometers. For alpha-decaying actinides (e.g., U-235, Pu-239, Np-237, Am-241), Q is in the 4-6 MeV range. Nearly all of this energy goes into the relatively light alpha particle, and approximately 100 keV is left over for the much heavier, recoiling daughter atom. Alpha-particle energy spectroscopy with TES-microcalorimeters has shown the ability to simultaneously resolve peaks that overlap in conventional alpha spectroscopy, with resolution now less than 1 keV full-width-at-half-maximum (FWHM) at 5.3 MeV. For total reaction energy spectroscopy, we use the same TES design as our alpha detectors, but embed a small radioactive sample (of about 1 Bq) directly inside an absorber designed to capture all the emitted particles (alpha, recoil nucleus, electrons, X-rays) with near 100% efficiency. We have measured Q-spectra of alpha-decaying isotopes with spectral resolution of 2-3 keV FWHM. For some actinide analytical problems, the Q-spectrum is simpler than the alpha-spectrum: fewer peaks, further apart, and easier to quantify. We will discuss sensor design, methods for embedding radionuclides, and spectral data.
Microcalorimeter sensors operated near 0.1 K can measure the energy of individual x- and gamma-ray photons with significantly more precision than conventional semiconductor technologies. Both microcalorimeter arrays and higher per pixel count rates are desirable to increase the total throughput of spectrometers based on these devices. The millisecond recovery time of gamma-ray microcalorimeters and the resulting pulse pileup are significant obstacles to high per pixel count rates. Here, we demonstrate operation of a microcalorimeter detector at elevated count rates by use of convolution filters designed to be orthogonal to the exponential tail of a preceding pulse. These filters allow operation at 50% higher count rates than conventional filters while largely preserving sensor energy resolution.
Nuclear forensics and environmental monitoring require rapid isotopic analysis of trace samples that contain multiple radioisotopes with closely spaced alpha particle energies. Conventional measurement of such a sample typically requires expensive and time-consuming radiochemical separations, measurement of multiple subsamples by silicon alpha spectrometry, and destructive analysis by mass spectrometry. The superior energy resolution of microcalorimeter detectors allows isotopic analysis with a single nonconsumptive alpha spectrometry measurement. In order to bring microcalorimeter alpha detector technology towards the goal of a practical analytical instrument, we have developed an eight-channel transition-edge sensor microcalorimeter system to enable rapid detector and source development. This system is now fully functional, and has enabled the identification of instabilities in our alpha detector response that resulted in degraded performance. A redesigned set of detectors has been fabricated and tested, and has shown significantly improved response. With the improved detectors, we have been able to consistently achieve energy resolution of less than 1 keV full width at half maximum at 5.3 MeV. We have prepared electroplated sources that contain 239-Pu and 240-Pu, demonstrated the ability to resolve their similar to 5.1 MeV alpha energy peaks with 0.74 keV FWHM resolution, and shown that the 240/239-Pu isotopic ratios obtained from our microcalorimeter spectra are in statistical agreement with mass spectrometry results.
Superconducting microcalorimeters based on transition-edge sensors (TESs) are being successfully used in applications ranging from optical photon counting to gamma-ray and alpha particle spectroscopy. Practical instruments often require a complex optimization among speed, linearity and energy resolution. However, a lack of understanding of the superconducting transition limits our ability to predict the behavior of a new TES design. Specifically, there is an unmet need for a model that predicts the current and temperature dependent resistance surface that describes the transition: R(I,T). This paper describes the predictions of a two-fluid model for the resistance of a TES based on a Ginzburg-Landau form of the critical current. We compare the predictions of the model for the logarithmic derivatives of resistance with temperature and current (α and β) to measurements of TESs used in x-ray and gamma spectrometers. The model shows excellent qualitative agreement that provides useful insight into the dependence of α and β on the current density and bias point of the TES.
We introduce a filter-construction method for pulse processing that differs in two respects from that in standard optimal filtering, in which the average pulse shape and noise-power spectral density are combined to create a convolution filter for estimating pulse heights. First, the proposed filters are computed in the time domain, to avoid periodicity artifacts of the discrete Fourier transform, and second, orthogonality constraints are imposed on the filters, to reduce the filtering procedure's sensitivity to unknown baseline height and pulse tails. We analyze the proposed filters, predicting energy resolution under several scenarios, and apply the filters to high-rate pulse data from gamma-rays measured by a transition-edge-sensor microcalorimeter.
Improvements in superconductor device fabrication, detector hybridization techniques, and superconducting quantum interference device readout have made square-centimeter-sized arrays of gammaray microcalorimeters, based on transition-edge sensors (TESs), possible. At these collecting areas, gamma microcalorimeters can utilize their unprecedented energy resolution to perform spectroscopy in a number of applications that are limited by closely-spaced spectral peaks, for example, the non-destructive analysis of nuclear materials. We have built a 256 pixel spectrometer with an average full-width-at-half-maximum energy resolution of 53 eV at 97 keV, a useable dynamic range above 400 keV, and a collecting area of 5 cm(2). We have demonstrated multiplexed readout of the full 256 pixel array with 236 of the pixels (91%) giving spectroscopic data. This is the largest multiplexed array of TES microcalorimeters to date. This paper will review the spectrometer, highlighting the instrument design, detector fabrication, readout, operation of the instrument, and data processing. Further, we describe the characterization and performance of the newest 256 pixel array. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4754630]
Alpha-particle spectrometry is a powerful analytical tool for nuclear forensics and environmental monitoring. Superconducting transition-edge sensor microcalorimeters have been shown to yield unsurpassed energy resolution for alpha spectrometry. With nearly an order of magnitude better energy resolution (1.06 keV FWHM at 5.3 MeV) than the current state-of-the-art silicon detectors (8-10 keV at 5.3 MeV), it is possible to measure samples containing multiple radioisotopes that would require expensive and time-consuming radiochemical separation prior to measurement with a silicon detector. This paper presents recent results from the Los Alamos four-channel microcalorimeter alpha spectrometer. We have prepared a source from weapons-grade plutonium and demonstrated the ability of microcalorimeter alpha spectrometry to simultaneously resolve alpha energies from 239 Pu, 240 Pu, 238 Pu, and 241 Am. The low-energy performance of the spectrometer system has been improved to allow measurement of energies as low as 5 keV, which gives a dynamic range of 1000. We have demonstrated this capability by simultaneously measuring the alpha particles and low-energy x-rays and internal conversion electrons emitted by an electroplated 240 Pu source.
Microcalorimeter detectors provide unprecedented energy resolution for the measurement of X-rays and soft gamma-rays. Energy resolution in the 100keV region can be up to an order of magnitude better than planar high-purity germanium (HPGe) detectors. The technology is well-suited to analysis of materials with complex spectra presenting closely spaced photopeaks. One application area is the measurement and assay of nuclear materials for safeguards and fuel cycle applications. In this paper, we discuss the operation and performance of a 256-pixel array, and present results of a head-to-head comparison of isotopic determination measurements with high-purity germanium using a plutonium standard. We show that the uncertainty of a single measurement is smaller for the microcalorimeter data compared to the HPGe data when photopeak areas are equal. We identify several key areas where analysis codes can be optimized that will likely lead to improvement in the microcalorimeter performance.