The National Ignition Facility uses a soft x-ray opacity spectrometer for x-ray spectral imaging in high-energy-density experiments. The increased demand for a better spectral resolution prompted the investigation into the Agfa D4 film. Characterization is already under way for the film. A Manson x-ray source using six different anodes was used to expose film to the linear optical density (OD) region. This is a continuation of the previous work, and the updated analysis process is communicated here. The identified uncertainties have been reduced with the updated steps that improve the results of the characterization process. When the Stanford Synchrotron Radiation Lightsource Beamline 16-2 was operational, the film was characterized at that source. Its beam offered a higher fluency with a lower exposure time needed to reach saturation. Results for both sources are compared in this paper.
Opacity measurements are being carried out at the Z-facility at Sandia National Laboratories and at the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. The current soft x-ray Opacity Spectrometer (OpSpec) used on the NIF uses two elliptically bent crystals in time-integrated mode on either an image plate or a film. Plans are under way to expand these opacity measurements into a mode of time-resolved detection, called OpSpecTR. Previously, considerations for the available hCMOS detector size and photometrics led to a crystal geometry redesign and the use of a grazing angle x-ray mirror. The mirror acts as a low-pass x-ray energy filter, reducing the contribution of higher energy x rays. The first tests of the mirror and the crystal for OpSpecTR are presented here. The size of the mirror reflection and the reflectivity is tested using a Manson x-ray source. The mirror coupled with the new elliptical crystal shape demonstrates OpSpecTR's spectral coverage. The results from the x-ray optics performance testing are shown along with the intended design.
A new time-resolved opacity spectrometer (OpSpecTR) is currently under development for the National Ignition Facility (NIF) opacity campaign. The spectrometer utilizes Icarus version 2 (IV2) hybridized complementary metal–oxide–semiconductor sensors to collect gated data at the time of the opacity transmission signal, unlocking the ability to collect higher-temperature measurements on NIF. Experimental conditions to achieve higher temperatures are feasible; however, backgrounds will dominate the data collected by the current time-integrating opacity spectrometer. The shortest available OpSpecTR integration time of ∼2 ns is predicted to reduce self-emission and other late-time backgrounds by up to 80%. Initially, three Icarus sensors will be used to collect data in the self-emission, backlighter, and absorption regions of the transmission spectrum, with plans to upgrade to five Daedalus sensors in future implementations with integration times of ∼1.3 ns. We present the details of the diagnostic design along with recent characterization results of the IV2 sensors.
Sagittally focusing x-ray crystal spectrometers with elliptical profiles in the meridional (x-ray dispersion) plane are proposed for plasma diagnostics in experiments accompanied by high neutron yields. The spectrometers feature a variable sagittal radius of curvature to ensure the sagittal focusing of rays for each photon energy in a chosen detection plane. The detector is placed after the ray crossing point at the second ellipse focus, and the source-to-detector distance is maximized to reduce the neutron-induced background. The elliptical shape imposes a limitation on the spectrometer geometry such that the influence of the source size on the spectral resolution can be avoided only for a demagnifying spectrometer (the source-to-crystal distance is larger than that of crystal-to-detector). Hence, two designs are proposed. The first design, featuring high magnification and limited spectral resolution can be suitable for x-ray continuum spectroscopy. The second design of high demagnification is optimized for spectral resolution, and can be used for time-resolved spectroscopy of plasma's characteristic emission lines using streak cameras. The key performance characteristics of the two designs are verified using ray tracing.
On December 5, 2022, an indirect drive fusion implosion on the National Ignition Facility (NIF) achieved a target gain G_{target} of 1.5. This is the first laboratory demonstration of exceeding "scientific breakeven" (or G_{target}>1) where 2.05 MJ of 351 nm laser light produced 3.1 MJ of total fusion yield, a result which significantly exceeds the Lawson criterion for fusion ignition as reported in a previous NIF implosion [H. Abu-Shawareb et al. (Indirect Drive ICF Collaboration), Phys. Rev. Lett. 129, 075001 (2022)PRLTAO0031-900710.1103/PhysRevLett.129.075001]. This achievement is the culmination of more than five decades of research and gives proof that laboratory fusion, based on fundamental physics principles, is possible. This Letter reports on the target, laser, design, and experimental advancements that led to this result.
X-ray opacity measurements on the National Ignition Facility (NIF) are in the process of reproducing earlier measurements from the Sandia Z Facility, in particular for oxygen and iron plasmas. These measurements have the potential to revise our understanding of the “solar problem” and of the hot degenerate Q class white dwarf structure by probing plasma conditions near the base of their convection zones. Accurate opacity measurements using soft x-ray Bragg crystal spectrometers require correction for higher-order diffraction effects. Extending prior work in this area [Dutra et al., Review of Scientific Instruments 93, 113527 (2022)], we have developed a new method to remove higher-order spectral components from NIF opacity spectrometer data. By modeling absorption and backlighting continuum spectra and subtracting the second- and third-order components from the measured data, we are able to perform this correction while avoiding imprinting first-order model line features onto the data.
Recent measurements at the Sandia National Laboratory of the x-ray transmission of iron plasma have inferred opacities much higher than predicted by theory, which casts doubt on modeling of iron x-ray radiative opacity at conditions close to the solar convective zone-radiative zone boundary. An increased radiative opacity of the solar mixture, in particular iron, is a possible explanation for the disagreement in the position of the solar convection zone-radiative zone boundary as measured by helioseismology and predicted by modeling using the most recent photosphere analysis of the elemental composition. Here, we present data from radiation burnthrough experiments, which do not support a large increase in the opacity of iron at conditions close to the base of the solar convection zone and provide a constraint on the possible values of both the mean opacity and the opacity in the x-ray range of the Sandia experiments. The data agree with opacity values from current state-of-the-art opacity modeling using the CASSANDRA opacity code.
Time-gated Sc K-shell and Ge L-shell spectra are presented from a range of characterized thermodynamic states spanning ion densities of 1019–1020cm−3 and plasma temperatures around 2000 eV. For the higher densities studied and temperatures from 1000 to 3000 eV, the Sc and Ge x-ray emission spectra are consistent with steady-state calculations from the modern atomic kinetics model SCRAM. At the lower ion densities achieved through plasma expansion, however, the model calculations require a higher plasma temperature to reproduce the observed Ge spectrum. We attribute this to ionization disequilibrium of the Sc because the ionization time scales exceed the hydrodynamic timescale when the inferred temperatures diverge.
The goal of the Xflows experimental campaign is to study the radiation flow on the National Ignition Facility (NIF) reproducing the sensitivity of the temperature (±8 eV, ±23 μm) and density (±11 mg/cc) measurements of the COAX platform [Johns et al., High Energy Density Phys. 39, 100939 (2021); Fryer et al., High Energy Density Phys. 35, 100738 (2020); and Coffing et al., Phys. Plasmas 29, 083302 (2022)]. This new platform will enable future astrophysical experiments involving supernova shock breakout, such as Radishock (Johns et al., Laboratory for Laser Energetics Annual Report 338, 2020) on OMEGA-60 [Boehly et al., Rev. Sci. Instrum. 66, 508 (1995)], and stochastic media (such as XFOL on OMEGA). Greater energy and larger physical scale on NIF [Moses et al., Eur. Phys. J. D 44, 215 (2007)] will enable a greater travel distance of radiation flow, higher density, and more manufacturable foams and enable exploration of a greater range of radiation behavior than achievable in the prior OMEGA experiments. This publication will describe the baseline configuration for the Xflows experimental campaign and the roadmap to achieve its primary objectives.
The COAX platform has been used in numerous experiments to study radiation flow from a laser-driven halfraum down a low-density SiO2 foam laden with Ti, Sc, or V as spectroscopic dopants. These experiments, conducted first at OMEGA-60 and transitioning to NIF, utilize 1-D space-resolving absorption spectroscopy to characterize the radiation flow temperature to within +8eV and density within +11mg/cc. Parallel point-projection radiography measurements capture the development of the transonic and subsonic shock, and the combination strongly constrains radiation hydrodynamics simulations. This presentation will overview our body of work in this area and advertise applications to laboratory astrophysics, materials studies, and ICF.
When compared with the National Ignition Facility's (NIF) original soft x-ray opacity spectrometer, which used a convex cylindrical design, an elliptically shaped design has helped to increase the signal-to-noise ratio and eliminated nearly all reflections from alternate crystal planes. The success of the elliptical geometry in the opacity experiments has driven a new elliptical geometry crystal with a spectral range covering 520-1100 eV. When coupled with the primary elliptical geometry, which spans 1000-2100 eV, the new sub-keV elliptical geometry helps to cover the full iron L-shell and major oxygen transitions important to solar opacity experimentation. The new design has been built and tested by using a Henke x-ray source and shows the desired spectral coverage. Additional plans are underway to expand these opacity measurements into a mode of time-resolved detection, ∼1 ns gated, but considerations for the detector size and photometrics mean a crystal geometry redesign. The new low-energy geometry, including preliminary results from the NIF opacity experiments, is presented along with the expansion plans into a time-resolved platform.
K-shell x-ray emission spectroscopy is a standard tool used to diagnose the plasma conditions created in high-energy-density physics experiments. In the simplest approach, the emissivity-weighted average temperature of the plasma can be extracted by fitting an emission spectrum to a single temperature condition. It is known, however, that a range of plasma conditions can contribute to the measured spectra due to a combination of the evolution of the sample and spatial gradients. In this work, we define a parameterized model of the temperature distribution and use Markov Chain Monte Carlo sampling of the input parameters, yielding uncertainties in the fit parameters to assess the uniqueness of the inferred temperature distribution. We present the analysis of time-integrated S and Fe x-ray spectroscopic data from the Orion laser facility and demonstrate that while fitting each spectral region to a single temperature yields two different temperatures, both spectra can be fit simultaneously with a single temperature distribution. We find that fitting both spectral regions together requires a maximum temperature of 1310-70 +90 eV with significant contributions from temperatures down to 200 eV.
The Opacity Platform on the National Ignition Facility (NIF) has been developed to measure opacities at varying densities and temperatures relevant to the solar interior and thermal cooling rates in white dwarf stars. The typical temperatures reached at NIF range between 150 and 210 eV, which allow these measurements to be performed experimentally. The captured opacities are crucial to validating radiation-hydrodynamic models that are used in astrophysics. The NIF opacity platform has a unique new capability that allows in situ measurement of the sample expansion. The sample expansion data are used to better understand the plasma conditions in our experiments by inferring the sample density throughout the duration of the laser drive. We present the details of the density measurement technique, data analysis, and recent results for Fe and MgO.
For more than half a century, researchers around the world have been engaged in attempts to achieve fusion ignition as a proof of principle of various fusion concepts. As recently reported, a burning plasma state, where the alpha-heating in the plasma is the primary source of heating, was achieved in laboratory experiments. Following the Lawson criterion, an ignited plasma is one where the fusion heating power is high enough to overcome all the physical processes that cool the fusion plasma, creating a positive thermodynamic feedback loop with rapidly increasing temperature. In inertially confined fusion, ignition is a state where the fusion plasma can begin ``burn propagation'' into surrounding cold fuel, enabling the possibility of high energy gain. While ``scientific breakeven'' (i.e. unity target gain) has not yet been achieved, this talk reports the first controlled fusion experiment on the National Ignition Facility to produce capsule gain greater than unity (here 5.8) and reach ignition by many different formulations of the Lawson criterion. In the talk, we will discuss some key basic physics inertial confinement fusion (ICF) principles behind the burning plasma and ignition results as well as discuss future challenges.
The Opacity Spectrometer (OpSpec) used in the National Ignition Facility's opacity experiments measures x-ray spectra from 0.9 to 2.1 keV from the different experimental regions: the backlight source, emission source, and the absorption region with the transmission calculated from these regions. The OpSpec designs have gone through several iterations to help improve the signal-to-noise ratio, remove alternate crystal plane reflections, and improve spectral resolution, which helps to increase the validity of the opacity measurements. However, the source spans well outside the current working spectral range, and higher-order reflections are intrinsic to the crystal, which increases the overall signal seen in the data regions. The recorded data are the convolution of 1st order transmission, higher-order reflections, and the penumbra blurring. This work represents the details for deconvolving the 2nd and 3rd order spectral energy corrections with a penumbral de-blurring to correct the relative measurement of x-ray intensity of different spectral energies and further analysis of datasets relevant to the opacity experiments.
new analysis of the anchor 1 data and compared the results to a series of calculations using the LANL ATOMIC code. Figures 1 and 2 compare the data with the best-fit to calculations. This result is significantly improved over the result published in Atoms. The differences are small for the iron quasi-continuum between 8-9.5 Å and for the Mg Heα and Lyα lines. The opacities near the centers of the iron bound-bound features also match fairly well in the 9.5-12.5 Å range. However, the opacity windows between the large iron bound-bound features are deeper in the Atomic predictions than the measurement. Furthermore, large discrepancies exist for the Mg He β, γ, and δ lines and for the short-wavelength quasicontinuum. The experiment and analysis refinements described below have set the stage for unraveling these discrepancies. Specifically, we can repeat the Anchor 1 experiments using improved backlighter, hohlraum, and spectrometers to obtain reduced backgrounds and better spectral resolution. Exploiting the AlMg calibration experiments and repeating the Anchor 1 measurements multiple times will enable formal and rigorous uncertainty determination. This well-defined path gives us confidence that high quality opacity data can be obtained on NIF.