In this study, dielectrophoresis (DEP) was performed to develop highly sensitive surface- enhanced Raman scattering (SERS)-active substrates for molecular sensing. Substrates with a circular hole pattern were used, and plasmonic particles were trapped and immobilized along the edges of the pattern using dielectrophoretic forces. The arranged particles created hotspots, resulting in an enhanced SERS signal that was detectable even at concentrations as low as 10-10 M. This uniform arrangement provided a consistent signal over a large area. In addition, it was experimentally verified that the behavior of the particles varied with pattern diameter. This phenomenon was further supported by theoretical analysis. The proposed DEP-based SERS substrates are expected to be useful in various applications due to their excellent reproducibility and reliability.
Digital PCR (dPCR) is a technique for absolute quantification of nucleic acid molecules. To develop a dPCR technique that enables more accurate nucleic acid detection and quantification, we established a novel dPCR apparatus known as centrifugal force real-time dPCR (crdPCR). This system is efficient than other systems with only 2.14% liquid loss by dispensing samples using centrifugal force. Moreover, we applied a technique for analyzing the real-time graph of the each micro-wells and distinguishing true/false positives using artificial intelligence to mitigate the rain, a persistent issue with dPCR. The limits of detection and quantification were 1.38 and 4.19 copies/μL, respectively, showing a two-fold higher sensitivity than that of other comparable devices. With the integration of this new technology, crdPCR will significantly contribute to research on next-generation PCR targeting absolute micro-analysis.
Semiconductor-based biosensor is important for the digital healthcare technology which is changing a healthcare paradigm from the hospital to the personal area. By combining a digital-biosensor with a microfluidic technology and automated mobile diagnosis system, peoples can monitor their body conditions in real-time themselves and thus prevent serious illnesses. In this presentation, semiconductor-based biosensors, disposable microfluidic device, and automated systems of the National NanoFab Center are introduced.
Effective and reliable antibacterial surfaces are in high demand in modern society. Although recent works have shown excellent antibacterial performance by combining unique hierarchical nanotopological structures with functional polymer coating, determining the antibacterial performance arising from morphological changes is necessary. In this work, three-dimensional (3D) hierarchical polyaniline–gold (PANI/Au) hybrid nanopillars were successfully fabricated via chemical polymerization (i.e., dilute method). The morphology and structures of the PANI/Au nanopillars were controlled by the reaction time (10 min to 60 h) and the molar concentrations of the monomer (0.01, 0.1, and 1 M aniline), oxidant (0.002, 0.0067, 0.01, and 0.02 M ammonium persulfate), and acid (0.01, 0.1, 1, and 2 M perchloric acid). These complex combinations allow controlling the hierarchical micro- to nanostructure of PANI on a nanopillar array (NPA). Furthermore, the surface of the 3D PANI/Au hierarchical nanostructure can be chemically treated while maintaining the structure using initiated chemical vapor deposition. Moreover, the excellent antibacterial performance of the 3D PANI/Au hierarchical nanostructure (HNS) exceeds 99% after functional polymer coating. The excellent antibacterial performance of the obtained 3D PANI/Au HNS is mainly because of the complex topological and physicochemical surface modification. Thus, these 3D PANI/Au hierarchical nanostructures are promising high-performance antibacterial materials.
An "all-in-one tube" platform is developed, where the genetic analysis involving DNA extraction, amplification, and detection can be performed in a single tube. The all-in-one tube consists of a polymerase chain reaction (PCR) tube in which the inner surface is conformally modified with a tertiary-amine-containing polymer to generate a strong electrostatic interaction with DNA. The all-in-one tube provides high DNA capture efficiency exceeding 80% from Escherichia coli O157: H7 pathogen at a wide range of DNA amount from 0.003 to 3 ng. Indeed, the use of the surface-functionalized PCR tube enables direct amplification and detection of the surface-captured DNA without the modification of standard real-time PCR instrument. Besides, this platform has sensitivity, selectivity, and reliability enough for accurate detection at the minimal infective dose of both gram-positive and negative pathogens. The all-in-one tube enables the direct molecular diagnosis, substantially reducing the labor-intensive pathogen detection steps while providing high compatibility with the currently established real-time PCR instruments, and illustrates its on-site applicability with convenience expandable to various genetic analyses including food safety testing, forensic analysis, and clinical diagnosis.
In article number 2100430 by Sung Gap Im, Kyoung G. Lee, and co-workers, an “all-in-one tube” is devised by coating poly-(2-dimethylaminomethyl styrene) (pDMAMS) on a polymerase chain reaction (PCR) tube via initiated chemical vapor deposition (iCVD) to extract, amplify, and detect pathogens within a single tube. The all-in-one tube can capture the DNA of the pathogens by charge interaction and directly perform real-time PCR, reducing the labor-intensive pathogen detection steps.
In line with growing interest in obesity management, there has been an increase in the amount of research focused on highly sensitive analysis systems for a small number of biomarers. In this paper, we introduce the highly ordered nanopillar electrode, featuring a high aspect ratio surface area that enables enhanced electron transfer. For fabrication of the flexible electrode, gold was evaporated by electronic beam lithography on polyurethane (PU), which has high flexibility. The fabricated nanopillar is 500 nm in diameter and 1500 nm in height. Based on the highly ordered nanostructure electrode, insulin was selected as a biomarker to monitor the insulin resistance associated with obesity. To effectively analyze the insulin, the self-assembled monolayer chemical was used to introduce the enzyme catalysis-based electrochemical immunoassay, leading to the analysis of the insulin concentration range from 0.1 to 1.0 ng/mL in the real sample. The square wave voltammetry principle was used to measure HRP-based electrochemical signal both electrochemically and quantitatively. Based on the nanostructural properties of significant electrochemical behavior, we successfully analyzed insulin in the plasma sample with high sensitivity (LOD of 0.1 ng/mL) and with high reproducibility (<10%). The obtained sensitivity of nanopillar electrode is approximately 10 times (1020%) greater than that of commercial electrode. The results demonstrated that the nanopillar electrode is suitable for precise and sensitive analysis of low-level biomolecules in medical and commercial fields.
The bacterial DNA was simply purified by magnetic particles with a portable vibration motor. To effectively extract DNA in the field, the 3D-printed device was employed with low electric power system.
Sensors with autonomous self-healing properties offer enhanced durability, reliability, and stability. Although numerous self-healing polymers have been attempted, achieving sensors with fast and reversible recovery under ambient conditions with high mechanical toughness remains challenging. Here, a highly sensitive wearable sensor made of a robust bio-based supramolecular polymer that is capable of self-healing via hydrogen bonding is presented. The integration of carbon fiber thread into a self-healing polymer matrix provides a new toolset that can easily be knitted into textile items to fabricate wearable sensors that show impressive self-healing efficiency (>97.0%) after 30 s at room temperature for K+/Na+ sensing. The wearable sweat-sensor system-coupled with a wireless electronic circuit board capable of transferring data to a smart phone-successfully monitors electrolyte ions in human perspiration noninvasively in real time, even in the healed state during indoor exercise. Our smart sensors represent an important advance toward futuristic personalized healthcare applications.
Since the increment of the threat to public health caused by foodborne pathogens, researches have been widely studied on developing the miniaturized detection system for the on-site pathogen detection. In the study, we focused on the development of portable, robust, and disposable film-based polymerase chain reaction (PCR) chip containing a multiplex chamber for simultaneous gene amplification. In order to simply fabricate and operate a film-based PCR chip, different kinds of PCR chambers were designed and fabricated using polyethylene terephthalate (PET) and polyvinyl chloride (PVC) adhesive film, in comparison with commercial PCR, which employs a stereotyped system at a bench-top scale. No reagent leakage was confirmed during the PCR thermal cycling using the film PCR chip, which indicates that the film PCR chip is structurally stable for rapid heat cycling for DNA amplification. Owing to use of the thin film to fabricate the PCR chip, we are able to realize fast thermal transfer from the heat block that leads to short PCR amplification time. Moreover, using the film PCR chip, we could even amplify the target pathogen with 10 CFU mL−1. The artificially infected milk with various concentration of Bacillus cereus was successfully amplified on a single film PCR chip. On the basis of the reliable results, the developed film PCR chip could be a useful tool as a POCT device to detect foodborne pathogens via genetic analysis.
Given the increased interest in public hygiene due to outbreaks of food poisoning, increased emphasis has been placed on developing novel monitoring systems for point-of-care testing (POCT) to evaluate pathogens causing foodborne illnesses. Here, we demonstrate a pathogen evaluation system utilizing simple film-based microfluidics, featuring simultaneous gene amplification, solution mixing, and electrochemical detection. To minimize and integrate the various functionalities into a single chip, patterned polyimide and polyester films were mainly used on a polycarbonate housing chip, allowing simple fabrication and alignment, in contrast to conventional polymerase chain reaction, which requires a complex biosensing system at a bench-top scale. The individual integrated sensing chip could be manually fabricated in 10 min. Using the developed film-based integrated biosensing chip, the genes from the pathogens causing foodborne illnesses were simultaneously amplified based on multiple designed microfluidic chambers and Hoechst 33258, which intercalates into double-stranded DNA, to generate the electrochemical signal. The target pathogen gene was accurately analyzed by square wave voltammetry (SWV) within the 25 s, while the gel electrophoresis required about 30 min. Based on the developed integrated biosensing chip, the 1.0 × 101 and 1.0 × 102 colony-forming unit (CFU) of Staphylococcus aureus and Escherichia coli were sensitively detected with high reproducibility in the 25 s. On the basis of the significant features of the film-based molecular analysis platform, we expect that the developed sensor could be applied to the screening of various pathogens as a POCT device.
Two-dimensional (2D) nanosheets have been extensively explored as electrode materials for the development of high-performance electrochemical biosensors due to their unique structural characteristics. Nevertheless, 2D nanosheets suffer from sheet aggregation issues limiting the electrical conductivity of layered metal sulfides or hydroxides. Here, we report high-performance glucose biosensors based on a three-dimensional (3D) aerogel composed of interconnected 2D MoS2 and graphene sheet. 3D MoS2/graphene aerogel (MGA) provides a large surface area for the effective immobilization of enzymes, and continuous framework of electrically conductive graphene sheets. Flow-injection amperometric evaluation of the glucose biosensor using a 3D MGA electrode exhibits a rapid response (similar to 4s), a linear detection range from 2 to 20 mM, a sensitivity of 3.36 mu A/mM, and a low limit of detection of 0.29 mM. Moreover, the interference response from oxidizable species, such as ascorbic acid, uric acid and dopamine is negligible at an operating potential of -0.45 V. (C) 2017 Elsevier Inc. All rights reserved.
Rapid and convenient isolation of nucleic acids (NAs) from cell lysate plays a key role for onsite gene expression analysis. Here, this study achieves one-step and efficient capture of NA directly from cell lysate by developing a cationic surface-modified mesh filter (SMF). By depositing cationic polymer via vapor-phase deposition process, strong charge interaction is introduced on the surface of the SMF to capture the negatively charged NAs. The NA capturing capability of SMF is confirmed by X-ray photoelectron spectroscopy, fluorescent microscopy, and zeta potential measurement. In addition, the genomic DNAs of Escherichia Coli O157:H7 can be extracted by the SMF from artificially infected food, and fluorescent signal is observed on the surface of SMF after amplification of target gene. The proposed SMF is able to provide a more simplified, convenient, and fast extraction method and can be applied to the fields of food safety testing, clinical diagnosis, or environmental pollutant monitoring.
Recently, foodborne pathogen is a common and distressing disease around world to cause a threat to life and economic damages and it is urgent to develop a tools to diagnosis of such pathogens in the early stage to prevent potential outbreak. Although conventional cell extraction and recovery of DNA from pathogen and PCR method have been widely used, the methods require complex steps, experts, and expensive chemicals and instruments to improve the PCR performance. Herein, we report a droplet-based polymerase chain reaction (ddPCR) system which allows identifying single-cell level of foodborne pathogens. E. coli O157:H7 and Salmonella cells were selected as model bacterial foodborne pathogens. The ddPCR system could be a useful platform for the quantitative detection of foodborne pathogens without any pretreatment process.
We have developed a pH sensitive sensor for monitoring acidity of an infected wound area, as well as a pH meter for real-time monitoring the pH value. The pH sensor was fabricated by depositing Au and Ag on a PET film using a semiconductor process. The electrodes consist of a working electrode and a reference electrode. Here, the reference electrode was fabricated by synthesizing Polyaniline (PANI) on Ag/AgCl, and the sensor was constructed with four channels in order to measure the pH value in a wide area evenly. Then, the completed system including the pH sensor is 5×5 cm 2 in size, and the measured values of pH range from 3 to 9, along with the slope of 50 mV / pH in the overall measurement.
Paper-based materials have attracted a great deal of attention in sensor applications because they are readily available, biodegradable, inexpensive, and mechanically flexible. Although paper-based sensors have been developed, but important obstacles remian, which include the retention of chemical and mechanical stabilities when paper is wetted. Herein, we develop a simple and scalable process for fabrication of newspaper-based platforms by coating of parylene C and patterning of metal layers. As-prepared parylene C-coated newspaper (PC-paper) provides low-cost, disposable, and mechanically and chemically stable electrochemical platforms for the development of potentiometric ion sensors for the detection of electrolyte cations, such as, H+ and K+. The pH and K+ sensors produced show near ideal Nernstian sensitivity, good repeatability, good ion selectivity, and low potential drift. These disposable, flexible ion sensors based on PC-paper platforms could provide new opportunities for the development of point-of-care testing sensors, for diagnostics, healthcare, and environment testing.
Prostate cancer (PC) is the second leading cause of cancer death for men worldwide. The serum prostate-specific antigen level test has been widely used to screen for PC. This method, however, exhibits a high false-positive rate, leading to over-diagnosis and over-treatment of PC patients. Extracellular microRNAs (miRNAs) recently provided valuable information including the site and the status of the cancers and thus emerged as new biomarkers for several cancers. Among them, miR141 and miR375 are the most pronounced biomarkers for the diagnosis of high-risk PC. Herein, we report an attomolar detection of miR141 and miR375 released from living PC cells by using a plasmonic nanowire interstice (PNI) sensor. This sensor showed a very low detection limit of 100 aM as well as a wide dynamic range from 100 aM to 100 pM for all target miRNAs. In addition, the PNI sensor could discriminate perfectly the diverse single-base mismatches in the miRNAs. More importantly, the PNI sensor successfully detected the extracellular miR141 and miR375 released from living PC cell lines (LNCaP and PC-3), proving the diagnostic ability of the sensor for PC. We anticipate that the present PNI sensor can hold great promise for the precise diagnosis and prognosis of various cancer patients as well as PC patients.
Isolation of specific cells from whole blood is important to monitor disease prognosis and diagnosis. In this study, a vibration-assisted filtration (VF) device has been developed for isolation and recovery of specific cells such as leukocytes and pathogenic bacteria from human whole blood. The VF device is composed of three layers which was fabricated using injection molding with cyclic olefin copolymer (COC) pellets consisting of: a top layer with coin-type vibration motor (Ф = 10mm), a middle plate with a 1μm or 3μm-pore filter membrane to separate of Staphylococcus aureus (S. aureus) cells or leukocytes (i.e. white blood cells) respectively, and a bottom chamber with conical-shaped microstructure. One milliliter of human whole blood was injected into a sample loading chamber using a 3μm-pore filter equipped in the VF device and the coin-type vibration motor applied external vibration force by generating a rotational fluid which enhances the filtration velocity due to the prevention of the cell clogging on the filter membrane. The effluent blood such as erythrocytes, platelet, and plasma was collected at the bottom chamber while the leukocytes were sieved by the filter membrane. The vibration-assisted leukocyte separation was able to finish within 200s while leukocyte separation took 1200s without vibration. Moreover, we successfully separated S. aureus from human whole blood using a 1μm-pore filter equipped VF device and it was further confirmed by genetic analysis. The proposed VF device provides an advanced cell separation platform in terms of simplicity, fast separation, and portability in the fields of point-of-care diagnostics.
The electrochemical performances of electrochemical biosensors largely depend on electrode characteristics, such as size, composition, surface area, and electron and ion conductivities. Herein, highly efficient electrocatalytic polyoxometalate (POM) was directly deposited on polymeric ionic liquid (PIL)-functionalized reduced graphene oxide (rGO) in a simple manner. The nano-sized POM with PIL functional groups was uniformly distributed on the surface of rGO sheets. The unique nanostructure of the resultant POM-g-rGO nanohybrids enabled well-defined multiple redox reaction of POMs and rapid electron transfer. In particular, as-prepared nanohybrids demonstrated high electrocatalytic activity for the electrochemical detection of H2O2 and glucose molecules in flow-injection biosensor device with high sensitivity, rapid response time, and low detection limit.