Background: Tubal disturbances often contribute to infertility. Conventional hysterosalpingography (HSG) is considered as standard in the assessment of the patency of the fallopian tubes, but requires ionizing radiation and is restricted to the imaging of endoluminal structures. Purpose: To evaluate dynamic magnetic resonance-HSG (dMR-HSG) in the diagnostic work-up in patients with infertility. Material and Methods: Thirty-seven consecutive infertile women underwent dMR-HSG: 20 ml of gadolinium-polyvidone solution (18.4 mM Dotarem 1:20 with polyvidone) were injected intracervically through a 5-Charriere balloon catheter while acquiring five consecutive flash-3D T1-weighted MR sequences with fat saturation. Two experienced readers assessed image quality and anatomic–pathologic correlations prospectively. The relevance of results was evaluated in the clinical context of each patient. Patient comfort was evaluated with a standardized questionnaire. Results: dMR-HSG was successfully completed in 33/37 patient with an average study time of 45 min. In 4 of 37 patients the catheter became dislodged during the examination, resulting in two complete diagnostic failures. Failure in another two patients was due to preliminary termination because of excessive pain and discomfort during the application of the contrast solution. The uterine cavity was completely visualized and bilateral fallopian tube patency was confirmed by dMR-HSG in 27 of 33 patients. Bilateral tubal occlusion was diagnosed in one of the remaining six patients and was confirmed by laparoscopy. Successful selective tubal catheterization was performed in one additional patient with unilateral and one patient with bilateral fallopian tube occlusion. In three cases, the catheter became dislocated at the end of the examination without demonstration of tubal patency. Since all three patients refused diagnostic laparoscopy and conventional HSG, possible bilateral occlusions of the fallopian tubes could not be further assessed. Conclusion: dMR-HSG with cervical cannulation and intracavitary gadolinium injection is feasible and allows assessment of the uterus, the fallopian tubes, and extra-uterine pelvic structures, while avoiding all ionizing radiation in infertile women aiming at pregnancy.
The purpose of this study was to compare the image quality of the intravascular contrast agent gadofosveset with the extracellular contrast agent gadoterate meglumine in time-resolved three-dimensional magnetic resonance (MR) angiography of the human arteries of the hand. The value of cuff compression technique for suppression of venous enhancement for both contrast agents was also investigated. Three-dimensional MR angiograms of both hands of 11 healthy volunteers were acquired for each contrast agent at 1.5-T, while subsystolic cuff compression was applied at one side. Quantitative and qualitative evaluation were performed and analyzed with Student’s t-test. Visualization of vessels was superior in the images acquired with gadofosveset, especially in the late phases. Quantitative and qualitative evaluation showed significantly higher values for gadofosveset. The cuff compression at the lower arm proved to be an effective method to enhance arterial vessels. In conclusion the blood pool agent gadofosveset is superior for the dynamic imaging of the vessels of the hand when compared with the extracellular contrast agent gadoterate meglumine. To fully utilize the advantages of intravascular contrast agents, venous overlay has to be delayed or reduced, which can be achieved effectively by subsystolic lower arm cuff compression.
A 71-year-old patient presented with low back pain and slowly progressive weakness of both legs. Within a few hours after lumbar myelography, paraplegia below level L2 evolved. MR-imaging revealed a discogenic stenosis at level Th10/11. Immediate decompression by costo-transversectomy led to reversal of the neurological deficits.
Background: Time-resolved (TR) contrast-enhanced 3D MR angiography has recently received considerable attention for the workup of cerebrovascular diseases, foremost dural arteriovenous fistula and arteriovenous malformation, and potentially for the evaluation of dural sinus thrombosis. Thereby, the dynamic visualization of cerebral vessels is enabled similar to the principle of digital subtraction angiography. Yet, its voxel size is relatively large due to an inherent trade-off between the desired spatial and temporal resolutions. The goal of this study was to evaluate whether the limited spatial resolution of TR MR venography (MRV) is sufficient to visualize dural venous sinuses. Methods: The prospective study included 20 patients without compromise of cerebral venous outflow. Two neuroradiologists independently graded the quality of visualization of 11 predefined dural venous sinuses on images of fast TR contrast-enhanced MRV (1.5 s/dataset; voxel size, 2 × 2 × 2.2 mm; acquisition time, 37.5 s) in comparison to time-of-flight (TOF) MRV (voxel size, 0.8 × 0.8 × 4 mm; acquisition time, 3 min 51 s) and steady-state contrast-enhanced 3D (VIBE) MRV (voxel size, 1.1 × 0.9 × 1.5 mm; acquisition time, 2 min 46 s). Results: The torcular Herophili (p < 0.001), left (p < 0.001) and right (p < 0.01) transverse sinus, and right jugular bulb (p < 0.05) were visualized better at TR MRV than at TOF MRV. For visualization of the small inferior sagittal sinus, TR MRV was inferior to VIBE (p < 0.001) and TOF (p < 0.05) sequences. The visibility of all other dural sinuses was equal. Conclusion: Despite the inferior spatial resolution, TR MRV depicted some large dural sinuses more clearly than TOF MRV. To overcome the visualization of smaller venous structures, TR MRV can be applied complementarily with high-resolution steady-state contrast-enhanced MRV.
Background. The aim of the study was to prospectively compare the diagnostic performance of CT angiography (CTA) with MR angiography (MRA) in the preoperative assessment of living renal donors. Methods. Forty-eight potential living renal donors (mean 51 years, 29–67 years) underwent multislice CTA and gadolinium-enhanced MRA. Six potential donors were excluded. Forty-two donors underwent minimal invasive retroperitoneoscopic nephrectomy (left 36, right 6) and their datasets available for analysis independently performed by two blinded radiologists. The surgical status served as gold standard. Results. In 42 donors (84 kidneys), CTA identified 63 kidneys with 1 artery (MRI 61), 19 with 2 arteries (MRI 20), one with three arteries (MRI 2), and one with four arteries (MRI 1). Considering only the side with the surgical status available for verification, both CT and MRI correctly characterized 35 of 36 donors with a single renal artery and five of six with one supernumerary artery. Two false positives were two arteries suggested as supernumerary both in CT and MRI not confirmed during surgery. CTA and MRA both correctly identified three accessory renal veins in two donors. Conclusion. CTA and MRA had the same accuracy for characterization of renal vasculature in the preoperative assessment of living renal donors.
OBJECTIVE:The purpose of our study was to assess the impact of various injection rates on contrast-enhanced high-resolution 3D MR angiography of the hand.MATERIALS AND METHODS:Ten healthy individuals (mean age, 24.4 years; range, 20-27 years) underwent 3D contrast-enhanced MR angiography of both hands. Starting 3 minutes before data acquisition, subsystolic upper arm cuff compression was applied unilaterally. A 1.5-T whole-body scanner with 3D gradient-echo sequence was used. Seven data sets (20 seconds) were obtained consecutively. I.v. contrast material of 0.1 mg/kg of body weight of gadobutrol was injected at rates of 0.5, 1.0, and 1.5 mL/s. For both hands, quantitative data evaluation was performed with contrast-to-noise ratio (CNR) in the radial, ulnar, palmar, and digital arteries and veins. Qualitative assessment of the arterial visualization score and venous contamination score was rated by two experienced radiologists using a 4-point scale.RESULTS:The lowest venous contamination score (CNR and reviewers' assessment) was observed with an injection rate of 0.5 mL/s (p < 0.05). For the arterial signal, the reviewers' assessment was that an injection rate of 0.5 mL/s was best (p = 0.08). Compression yielded a significantly lower venous contamination score for the compressed side than for the noncompressed side for flow rates of 0.5 mL/s and 1.0 mL/s (p < 0.05).CONCLUSION:Image quality of hand MR angiography was better with cuff compression. A flow rate of 0.5 mL/s yielded a good CNR and a significantly lower venous contamination score than the other flow rates.
OBJECTIVE. Our objective was to compare the image quality of reconstructed thin sections obtained from a 16-MDCT scanner with that of axial high-resolution CT scans of the same patient.SUBJECTS AND METHODS. Fifty consecutive patients referred for CT of the chest underwent 16-MDCT and, subsequently, axial high-resolution CT. The volumetric raw data from the MDCT scans were reconstructed into slices 2-mm thick using a high-spatial-frequency reconstruction algorithm. Two blinded reviewers independently rated the images from both methods for subjective image-quality criteria. The results were tested for statistical significance using Wilcoxon's signed rank test, and p values of less than 0.05 were considered significant. The effective dose for axial high-resolution CT and volumetric MDCT was calculated.RESULTS. Motion artifacts were significantly more common on high-resolution CT scans than on reconstructed thin-section images (p < 0.001). The two methods differed significantly in lung attenuation (p = 0.008), mainly because of the presence of ground-glass opacities. The assessment of ground-glass attenuation was superior on axial high-resolution CT. The effective doses were 3.8 mSv for MDCT and 0.9 mSv for high-resolution CT.CONCLUSION. Reconstructed high-resolution images generated from a single MDCT data acquisition are of comparable quality to images obtained using conventional axial high-resolution CT. However, contiguous MDCT is not recommended for diseases showing predominantly ground-glass patterns, because axial high-resolution CT delineates ground-glass attenuation significantly better.
OBJECTIVE:We examined potential factors that may cause false-negative results on CT colonography examinations.MATERIALS AND METHODS:In this prospective and retrospective study, 500 asymptomatic patients at high risk for colorectal cancer underwent CT colonography and colonoscopy. Each CT data set was interpreted by two independent observers, who were unaware of endoscopic findings, using a method of searching through enlarged axial images to detect intraluminal lesions. Another observer identified and characterized lesions missed at prospective interpretation. Polyps were assessed for size, method of visualization, intrinsic and extrinsic features, and examination quality.RESULTS:We found 116 polyps at least 5 mm in diameter, 54 (47%) of which were missed by at least one of the prospective observers. Polyps seen in only one position were missed more often than polyps seen in both supine and prone positions (84% vs 50%, p < 0.01). Polyps located in suboptimally prepared colonic segments or along a thickened colonic wall were more frequently missed (p = 0.02 and p = 0.05, respectively). Endoscopic morphology and irregular surface contour were associated with missed lesions of all sizes (p = 0.03 and p = 0.04, respectively). Rounded intraluminal lesions were detected more often than other morphologies on CT (p = 0.04).CONCLUSION:Factors that influence the likelihood that a polyp may be missed at interpretation of CT colonography include being seen only in one position, having flat endoscopic or CT morphology, having surface irregularity, and being located in a poorly prepared segment or along a thickened colonic wall. Understanding these features should lead to improved polyp detection on CT colonography.
Cecal pathology is commonly encountered and may represent a diagnostic challenge in patients with either acute or chronic clinical presentations. Although appendicitis accounts for the majority of surgical conditions presenting with right lower quadrant pain, readers should be aware of the broad spectrum of cecal pathologies and characteristic CT findings, which can be useful in establishing the correct diagnosis.
PURPOSE:To prospectively assess and compare perceptions of and preferences for computed tomographic (CT) colonography, colonoscopy, and double-contrast barium enema examination (DCBE) by asymptomatic patients undergoing colorectal cancer screening.MATERIALS AND METHODS:A total of 696 asymptomatic patients at higher-than-average risk undergoing colorectal cancer screening were consecutively recruited to undergo both CT colonography and colonoscopy (group 1), and a like group of 617 patients was separately recruited to undergo both CT colonography and DCBE (group 2). Standard bowel preparations were different between the groups undergoing colonoscopy and DCBE. Each patient completed a questionnaire that assessed preparation inconvenience and discomfort, examination discomfort, willingness to repeat examinations, and examination preference. Survey results were compared for significance by using the Wilcoxon rank sum or chi2 test.RESULTS:The majority of patients considered the preparation to be uncomfortable (group 1, 460 of 515 [89%]; group 2, 482 of 538 [90%]) and inconvenient (group 1, 393 of 502 [78%]; group 2, 427 of 527 [81%]). Reported discomfort was similar at CT colonography and colonoscopy (P =.63) but was less at CT colonography than at DCBE (P <.001). Patients experienced significantly less discomfort than expected at both CT colonography and colonoscopy but not at DCBE. Patients' willingness to undergo frequent rescreening was significantly greater for CT colonography than for either colonoscopy or DCBE. The acceptable time interval between screenings was significantly shorter for all examinations if the bowel preparation could be avoided. Overall, patients preferred CT colonography to colonoscopy (group 1, 72.3% vs 5.1%; P <.001) or to DCBE (group 2, 97.0% vs 0.4%; P <.001).CONCLUSION:Patients undergoing colorectal cancer screening prefer CT colonography to both colonoscopy and DCBE. The majority of patients experience discomfort and inconvenience with cathartic bowel preparation.
Background & Aims: To assess the prevalence and spectrum of extracolonic findings in a screening population undergoing computed tomography colonography (CTC), and to evaluate the short-term direct medical costs incurred from subsequent radiologic follow-up evaluation. Methods: Six hundred and eighty-one asymptomatic patients undergoing colonoscopy screening consented to a CTC examination. Extracolonic CT findings were classified into high, medium, and low importance. Clinical and radiologic follow-up, missed lesions, and outcomes were assessed by chart review (time interval, 410-1513 days; median, 913 days). Short-term direct medical costs of radiologic follow-up were determined based on Medicare 2002 reimbursement rates. Results: Extracolonic findings were found commonly. These were categorized as high clinical importance in 71 (10%) individuals, as medium importance in 183 individuals (27%), and as low importance in 341 individuals (50%). Subsequent medical or surgical interventions resulted from these findings in 9 of the 681 patients (1.3%). Costs of subsequent radiologic follow-up studies were calculated as $23,380.59 (average added costs per CTC examination $34.33). Conclusions: CTC commonly detects extracolonic findings that can be considered clinically important when applied to an asymptomatic screening population. Although such incidental findings add benefit to the screening intervention, moderate incremental costs are incurred based on additional radiologic procedures generated during short-term follow-up.
The aim of this study was to determine the impact of the learning curve on the diagnostic performances of CT colonography. Two blinded teams, each having a radiologist and gastroenterologist, prospectively examined 50 patients using helical CT scan followed by colonoscopy. Intermediate data evaluation was performed after 24 data sets (group 1) and compared with data from 26 subsequent patients (group 2). Parameters evaluated included sensitivity, specificity, false-positive and false-negative findings, time of data acquisition and interpretation. Using colonoscopy as the gold standard, sensitivity for CT colonography was for lesions >5 mm 63% for both teams for group 1 patients; for group 2 patients sensitivity was 45% for team 1 and 64% for team 2. Specificity per patients was for patient group 1 42% for team 1 and 58% for team 2; for patient group 2 it was 79% for both teams ( p=0.04 for team 1; p=0.2 for team 2). Comparing group 1 with group 2, the number of false-positive findings decreased significantly ( p=0.02). Furthermore, the mean time of data evaluation decreased from 45 to 17 min ( p=0.002) and the mean time of data acquisition from 19 to 17 min. With increasing experience, specificity and the time required for data interpretation improved and false positives decreased. There was no significant change of sensitivity, false-negative findings and time of data acquisition. A minimum experience of the readers is required for data interpretation of CT colonography.
Computed tomography colonography (CTC) is a new, rapidly developing non-invasive CT technique used to detect colonic polyps and cancers. It employs two- (2D) and three-dimensional (3D) images of the colon in order to display neoplastic lesions. Clinical trials demonstrate promising results for the detection of polyps and cancers greater than or equal to 10 mm in size. Our purpose is to describe the technique of CT colonography, review recent published trials of CT colonography, and elucidate current clinical applications. Continuing technical innovations such as multidetector CT, computer-aided diagnosis, new image display techniques and faecal tagging promise to improve the performance and patient acceptance of CT colonography in the future.
Colorectal cancer is the second leading cause of malignancy-related deaths in the United States. Every year about 140,000 new cases and 55,300 deaths are reported (Wingo et al. 1995). The vast majority of colorectal cancers are believed to arise from adenomatous polyps (Stryker et al. 1987). There is evidence that early removal of adenomatous polyps and early carcinomas will reduce mortality (Winawer et al. 1997). Screening for colorectal cancer is now widely recommended (Eddy 1990). The goal of screening should be detection of these precursor lesions. Unfortunately, currently available screening methods are either poorly specific or sensitive (fecal occult blood testing, sigmoidoscopy) or too expensive and invasive (total colonoscopy; Liebermann and Smith 1991)