A neutron spectrometry campaign was carried out in the AMANDE accelerator control room. These measurements had several objectives, one of which was to verify the possibility of determining, with the HERMEIS Bonner sphere system, very low fluence and ambient dose equivalent rates. These measurements were also expected to provide comparison values with calculations, performed with MCNPX 2.6.0, used for modeling the whole facility and to verify the radiological zoning implemented. Neutrons of 3.3 MeV then 15 MeV were produced in the experimental hall of AMANDE and measurements were made in the control room, behind a 40 cm thick concrete wall. The ambient dose equivalent rates derived from the measured spectra are respectively of the order of 0.2 and 10 μSv/h, which are in agreement with a LB6411 surveymeter data also involved.
Neutron capture cross sections of 232T/i have been measured relative to 197Au in the energy region from 30 keV to 600 keV. The neutron source was the reaction 7Li(p, n) produced on the 4 MV Van de Graaff Accelerator of the Centre d' Etudes Nucléaires de Bordeaux (CENBG). Preliminary analysis of the measurements indicates that the cross sections are closer to the JENDL database values.
The variation in the response of instruments with neutron energy has to be determined in well-characterized monoenergetic neutron fields. The quantities associated with these fields are the neutron fluence and the mean energy of the monoenergetic neutron peak needed to determine the related dosimetric quantities. At the IRSN AMANDE facility, the reference measurement standard for neutron fluence is based on a long counter calibrated in the IRSN reference Cf-252 neutron field. In this paper, the final characterization of this device is presented as well as the method used to determine the reference fluence at the calibration point in monoenergetic neutron fields.
Journal Article Twelfth Symposium on Neutron and Ion Dosimetry – NEUDOS-12 Get access Jean-François Bottollier-Depois, Jean-François Bottollier-Depois Institute for Radiological Protection and Nuclear Safety (IRSN), France jeanfrancois.bottollier@irsn.fr Search for other works by this author on: Oxford Academic PubMed Google Scholar Véronique Lacoste Véronique Lacoste Institute for Radiological Protection and Nuclear Safety (IRSN), France Search for other works by this author on: Oxford Academic PubMed Google Scholar Radiation Protection Dosimetry, Volume 161, Issue 1-4, October 2014, Pages 1–2, https://doi.org/10.1093/rpd/ncu280 Published: 28 August 2014
Purpose: Measure stray radiation inside a passive scattering proton therapy facility, compare values to Monte Carlo (MC) simulations and identify the actual needs and challenges. Methods: Measurements and MC simulations were considered to acknowledge neutron exposure associated with 75 MeV ocular or 180 MeV intracranial passively scattered proton treatments. First, using a specifically-designed high sensitivity Bonner Sphere system, neutron spectra were measured at different positions inside the treatment rooms. Next, measurement-based mapping of neutron ambient dose equivalent was fulfilled using several TEPCs and rem-meters. Finally, photon and neutron organ doses were measured using TLDs, RPLs and PADCs set inside anthropomorphic phantoms (Rando, 1 and 5-years-old CIRS). All measurements were also simulated with MCNPX to investigate the efficiency of MC models in predicting stray neutrons considering different nuclear cross sections and models. Results: Knowledge of the neutron fluence and energy distribution inside a proton therapy room is critical for stray radiation dosimetry. However, as spectrometry unfolding is initiated using a MC guess spectrum and suffers from algorithmic limits a 20% spectrometry uncertainty is expected. H*(10) mapping with TEPCs and rem-meters showed a good agreement between the detectors. Differences within measurement uncertainty (10–15%) were observed and are inherent to the energy, fluence and directional response of each detector. For a typical ocular and intracranial treatment respectively, neutron doses outside the clinical target volume of 0.4 and 11 mGy were measured inside the Rando phantom. Photon doses were 2–10 times lower depending on organs position. High uncertainties (40%) are inherent to TLDs and PADCs measurements due to the need for neutron spectra at detector position. Finally, stray neutrons prediction with MC simulations proved to be extremely dependent on proton beam energy and the used nuclear models and cross sections. Conclusion: This work highlights measurement and simulation limits for ion therapy radiation protection applications.
Particles originating from primary cosmic radiation, which hit the Earth's atmosphere give rise to a complex field of secondary particles. These particles include neutrons, protons, muons, pions, etc. Since the 1980s it has been known that terrestrial cosmic rays can penetrate the natural shielding of buildings, equipment and circuit package and induce soft errors in integrated circuits. Recently, research has shown that commercial static random access memories are now so small and sufficiently sensitive that single event upsets (SEUs) may be induced from the electronic stopping of a proton. With continued advancements in process size, this downward trend in sensitivity is expected to continue. Then, muon soft errors have been predicted for nano-electronics. This paper describes the effects in the specific cases such as neutron-, proton- and muon-induced SEU observed in complementary metal-oxide semiconductor. The results will allow investigating the technology node sensitivity along the scaling trend.
Monte Carlo simulations were used to assess secondary neutron doses received by patients treated with proton therapy for ocular melanoma and craniopharyngioma. MCNPX calculations of out-of-field doses were done for ∼20 different organs considering realistic treatment plans and using computational phantoms representative of an adult male individual. Simulations showed higher secondary neutron doses for intracranial treatments, ∼14 mGy to the salivary glands, when compared with ocular treatments, ∼0.6 mGy to the non-treated eye. This secondary dose increase is mainly due to the higher proton beam energy (178 vs. 75 MeV) as well as to the impact of the different beam parameters (modulation, collimation, field size etc.). Moreover, when compared with published data, the assessed secondary neutron doses showed similar trends, but sometimes with sensitive differences. This confirms secondary neutrons to be directly dependent on beam energy, modulation technique, treatment configuration and methodology.
Monte Carlo calculations are increasingly used to assess stray radiation dose to healthy organs of proton therapy patients and estimate the risk of secondary cancer. Among the secondary particles, neutrons are of primary concern due to their high relative biological effectiveness. The validation of Monte Carlo simulations for out-of-field neutron doses remains however a major challenge to the community. Therefore this work focused on developing a global experimental approach to test the reliability of the MCNPX models of two proton therapy installations operating at 75 and 178 MeV for ocular and intracranial tumor treatments, respectively. The method consists of comparing Monte Carlo calculations against experimental measurements of: (a) neutron spectrometry inside the treatment room, (b) neutron ambient dose equivalent at several points within the treatment room, (c) secondary organ-specific neutron doses inside the Rando-Alderson anthropomorphic phantom. Results have proven that Monte Carlo models correctly reproduce secondary neutrons within the two proton therapy treatment rooms. Sensitive differences between experimental measurements and simulations were nonetheless observed especially with the highest beam energy. The study demonstrated the need for improved measurement tools, especially at the high neutron energy range, and more accurate physical models and cross sections within the Monte Carlo code to correctly assess secondary neutron doses in proton therapy applications.
In this paper are described measurements at high-altitude of both radiation environment and effects. These measurements comprise cosmic ray neutrons and SBU/MCU on nanoscales devices. Results obtained at Pic-du-Midi, France, and in the city of Puno, Peru, are presented and analyzed. Analyses and cross comparisons based-on MUSCA SEP3 calculations show a good agreement between experimental data and ...
In this paper, high-altitude measurements of both radiation environment and effects are described. Measurements are made using a neutron spectrometer and CCD camera. MUSCA SEP3 software is used to correlate both measurement approaches. Analyses of the charge levels in pixels induced by radiation events are proposed. Then, cross-comparison analyses based on a CCD camera and HERMEIS neutron spectrometer are performed to investigate radiation dynamic properties, including neutron/proton and muon contributions.
In this paper, a Bonner Sphere Spectrometer extended to high energies (HERMEIS) was employed to measure continuously the cosmic-ray-induced neutron spectra over a long-term period (2 y) at mountain altitude and medium geomagnetic latitude (Pic du Midi de Bigorre in the French Pyrenees, +2885 m, 5.6 GV). The results showed 1-y sinusoidal oscillations in the integrated fluence rates. The amplitude of these oscillations depends on the neutron energetic domain. The fluence rate of thermal neutrons was 53 % higher in August than that in February. Those of epithermal neutrons with energies between 0.4 eV and 0.1 MeV and evaporation neutrons (from 0.1 to 20 MeV) were ∼25 % higher in the summer than those in the winter. Finally, the cascade neutron fluence rate (>20 MeV) remained quite the same (<10 % variation). To understand the effects of local and seasonal changes in the measurement environment, GEANT4 simulations were performed. The nature of rock and thickness of the snow cover during the winter period (given by meteorological data) were investigated. A reasonable agreement between experiments and calculations was found.
In this paper are described measurements at high-altitude of both radiation environment and effects. These measurements comprise cosmic ray neutrons and SBU/MCU on nanoscales devices. Results obtained at Pic-du-Midi, France, and in the city of Puno, Peru, are presented and analyzed. Analyses and cross comparisons based-on MUSCA SEP3 calculations show a good agreement between experimental data and modeling, thus illustrating the importance of the knowledge of the radiation field for a reliable prediction.
The ITER International Fusion Energy Organization has solicited IRSN Laboratory for Neutron Metrology and Dosimetry to study the possibility to calibrate, in monoenergetic neutron fields at 14 and 2.45 MeV, the neutron detectors to be placed inside the future fusion reactor. In addition to the estimate of the necessary irradiation times, the dose equivalent rates from some of the neutron activated beam line elements had been calculated to consider the cooling time mandatory before access. Neutron activation calculations have been performed with the Fluka Monte-Carlo code. The resulting dose equivalent rates depend strongly of the neutron beam intensity as well as the neutron energy. In the worst case, for 14 meV neutrons at an emission rate of 10(12) s(-1), a cooling time of 24 h would be needed for a close access to the shadow cone. Several days would be mandatory in the case of the target holder. (C) 2013 Elsevier Ltd. All rights reserved.
A Bonner sphere spectrometer extended to high energies (HERMEIS) was set up at the summit of the Pic du Midi de Bigorre in the French Pyrenees (altitude: +2,885 m; geomagnetic cutoff: 5.6 GV) in May 2011. The spectral fluence rate distribution of the cosmic ray induced neutrons was continuously measured over a broad energy range from meV up to several GeV and with a 1 h time resolution. While the Sun's activity was increasing and reaching its 24th maximum in the 11 year solar cycle, some Forbush decreases were observed in the atmospheric secondary radiation at mountain altitude. We investigated the evolution of the cascade fluence rate (i.e., neutrons with energy greater than 20 MeV) during the March 2012 events with a series of strong coronal mass ejections hitting the Earth's magnetosphere. The amplitude of the greatest Forbush decrease peaked at 10%. Then, a simulation work based on the GEANT4 toolkit was carried out to quantify the solar modulation induced on the galactic cosmic ray transportation during these events. We performed calculations of extensive air showers generated by monoenergetic primaries (Hydrogen and Helium nuclei) for several zenith incidences. Hence, a complete database was built and validated. We derived an analytical model to estimate the atmospheric neutron spectrum at the Pic du Midi according to primary spectra which only depend on the solar modulation potential (force field approximation). We compared the solar modulation potentials obtained in March 2012 with the ones derived by the neutron monitor yield method. Finally, a satisfying agreement was found.
A new platform dedicated to the long-term characterization of the Atmospheric Natural Radiative Environment at mountain altitude (Pic du Midi, +2885 m) is presented. The performance of a high energy neutron spectrometer is established with measurements performed in a realistic neutron field and by comparison with the neutron monitors. A SEE-rate prediction approach is also used on a 90 nm SRAM memory array which was irradiated at CERF and set up at the Pic du Midi during almost one year.
The Institute for Radiological Protection and Nuclear Safety (IRSN) has developed a new spectrometry system for neutron energies from 10−9 MeV to 10 GeV. This high energy range multisphere extended IRSN system (HERMEIS) is a high gas pressure3He-based Bonner spheres set. It is adapted to low neutron fluence rate measurements and one of its main application concerns the determination of cosmic-ray-induced neutron spectra at ground level and mountain altitudes. The neutron fluence response matrix of the set of 13 Bonner spheres, including three extended ones with tungsten and lead shells, was calculated with the radiation transport code MCNPX-2.6f. Reliable fluence responses being mandatory for a correct evaluation of the atmospheric neutron spectra, HERMEIS was characterized at standard monoenergetic, quasi-monoenergetic and realistic neutron fields facilities. Measurements with monoenergetic neutron beams of 144 keV, 565 keV, 5 MeV and 17 MeV were performed at the NPL standard Van de Graaff facility. For the characterization of the response functions at higher energies, measurements were done at the Svedberg Laboratory, with 46 MeV and 144 MeV quasi-monoenergetic neutrons. Finally, to demonstrate the suitability of the system for broad cosmic-ray neutron spectra, measurements were performed at the TSL Atmospheric-like Neutrons from thIck TArget (ANITA) and also at the CERN European Realistic Field (CERF) facilities. Data from the realistic spectra were unfolded with the GRAVEL unfolding code and as a whole, a good agreement was found between the experimental and Monte-Carlo calculated neutron fluence energy distributions.
Measurements performed with the High Energy Range Multisphere Extended IRSN System (HERMEIS) acquired by the French Aerospace Lab are presented and discussed. The detectors were calibrated at the Low Noise Underground Laboratory of Rustrel. Atmospheric neutron spectra were obtained at three altitudes ( ${+}500$ m, ${+}1000$ m and ${+}2885$ m) and the first results about the continuous measurements of the Natural Radiative Environment at the Pic du Midi are presented with a discussion about the uncertainties.
The use of simulated workplace neutron fields, which aim at replicating radiation fields at practical workplaces, is an alternative solution for the calibration of neutron dosemeters. They offer more appropriate calibration coefficients when the mean fluence-to-dose equivalent conversion coefficients of the simulated and practical fields are comparable. Intensive Monte Carlo modelling work has become quite indispensable for the design and/or the characterization of the produced mixed neutron/photon fields, and the use of Bonner sphere systems and proton recoil spectrometers is also mandatory for a reliable experimental determination of the neutron fluence energy distribution over the whole energy range. The establishment of a calibration capability with a simulated workplace neutron field is not an easy task; to date only few facilities are available as standard calibration fields.
The production of unwanted neutrons by electron linear accelerators (LINACs) has attracted a special attention since the early 50s. The renewed interest in this topic during the last years is due mainly to the increased use of such machines in radiotherapy. Specially, in most of developing countries where many old teletherapy irradiators, based on 60Co and 137Cs radioactive sources, are being replaced with new LINAC units. The main objective of this work is to report the results of an experimental characterization of the neutron spectra generated by a high-energy clinical LINAC. Measurements were carried out, considering four irradiation configurations, by means of our recently developed passive Bonner sphere spectrometer (BSS) using pure gold activation foils as central detectors. This system offers the possibility to measure neutrons over a wide energy range (from thermal up to a few MeV) at pulsed, intense and complex mixed n–γ fields. A two-step unfolding method that combines the NUBAY and MAXED codes was applied to derive the final neutron spectra as well as their associated integral quantities (in terms of total neutron fluence and ambient dose equivalent rates) and fluence-averaged energies.