NiTi powder is processed into tensile rods with a diameter of 150–220 µm using laser powder bed fusion with identical laser and scan parameters to investigate their properties as a function of the inclination angle to the build platform. Metallographic analysis shows that the melt pools in inclined rods (inclination angles >0° and <90°) extend partially perpendicularly into the powder bed due to the delicate nature of the structures and poor heat dissipation of the powder bed compared to the solidified material. Chemical analysis confirms the results of the thermal characterization: the nickel content decreases with increasing inclination angle, causing the transformation temperatures to rise. This behavior is reflected in the mechanical behavior, which, with identical manufacturing parameters, ranges from elastic–plastic behavior to martensite detwinning under load. In a second step, the scan parameters are adjusted as a function of the inclination angle with the intention to minimize the differences in properties. However, the results show that no significant changes in the thermal and mechanical properties are achieved, and therefore the scan vector length plays a minor role in the properties of such filigree structures compared to other parameters.
Determining accurate values on specimen cross-sectional areas is crucial when conducting biomechanical experiments in an effort to derive meaningful properties such as ultimate tensile strength and elastic modulus. Several studies have investigated various methods for cross-section measurements using various soft tissues and applications. Comparison between methods is missing to date especially for (human) biological soft tissues. This given study determined the cross-sectional areas of ten synthetic polyamide 12 and twenty-nine human iliotibial band specimens. It used the following four commonly deployed methods: caliper gauge (CG), molding compound (MC), X-ray micro computed tomography (μCT) and digital image correlation (DIC). The repeatability coefficient was calculated for the four methods and the agreement between the four methods were compared using Bland-Altman plots. All methods but CG offer consistent and reliable measurements of iliotibial band cross section determination, with no difference in their performance levels. In the polyamide specimens, cross-section determination using μCT appeared to provide the best repeatability coefficient RC (0.09 mm2 and 0.18 mm2 with reduced voxel resolution). It shows also for iliotibial band specimens the best agreements especially when compared to MC with a bias less than 1 % and limits of agreements lower ±25 %. The given data suggest that any of the given methods, μCT, MC or DIC can be used effectively for CSA measurements of soft tissues. Minor methodological discrepancies were observed exclusively in specimens with highly uniform geometries. The principal limiting factor appears to be inherent tissue-specific variability rather than the measurement precision of the applied systems. In contrast, due to systematic bias and poor concordance with all other methods investigated, CG cannot be recommended for accurate CSA determination of soft tissue specimens.
When conducting biomechanical testing or clinical training using embalmed human soft tissues, it is essential to understand their impact on biomechanical properties and their time dependence. Previous studies have investigated this influence, but specific variations over different embalming durations have not been thoroughly addressed to date.Ninety-seven human iliotibial band specimens were obtained from nine donors. All specimens were embalmed in ethanol-glycerin for varying durations: one day, eight days, and fourteen days. Prior to the mechanical trials, the specimens underwent osmotic water adjustment, tapering and standardized clamping. Uniaxial tensile tests were conducted to determine elastic modulus, ultimate tensile strength, and ultimate strain. Surface strain measurements were performed using a digital image correlation system.Ethanol-glycerin embalming of soft tissues significantly affects ultimate strain after one day of submersion time, elastic modulus after eight days, and the ultimate tensile strength after fourteen days. For applications requiring consistent and reliable material properties reflecting a (supra-)vital state, caution is advised against using embalmed tissues even following short submersion durations in ethanol-glycerin.
The use of stereotactic frames is a common practice in neurosurgical interventions such as brain biopsy and deep brain stimulation. However, conventional stereotactic frames have been shown to require modification and adaptation regarding patient and surgeon comfort as well as the increasing demand for individualized medical treatment. To meet these requirements for carrying out state-of-the-art neurosurgery, a 3D print-based, patient-specific stereotactic system was developed and examined for technical accuracy. Sixteen patient-specific frames, each with two target points, were additively manufactured from PA12 using the Multi Jet Fusion process. The 32 target points aim to maximize the variability of biopsy targets and depths for tissue sample retrieval in the brain. Following manufacturing, the frames were measured three-dimensionally using an optical scanner. The frames underwent an autoclave sterilization process prior to rescanning. The scan-generated models were compared with the planned CAD models and the deviation of the planned target points in the XY-plane, Z-direction and in the resulting direction were determined. Significantly lower (p < 0.01) deviations were observed when comparing CAD vs. print and print vs. sterile in the Z-direction (0.17 mm and 0.06 mm, respectively) than in the XY-plane (0.46 mm and 0.16 mm, respectively). The resulting target point deviation (0.51 mm) and the XY-plane (0.46 mm) are significantly higher (p < 0.01) in the CAD vs. print comparison than in the print vs. sterile comparison (0.18 mm and 0.16 mm, respectively). On average, the results from the 32 target positions examined exceeded the clinically required accuracy for a brain biopsy (2 mm) by more than four times. The patient-specific stereotaxic frames meet the requirements of modern neurosurgical navigation and make no compromises when it comes to accuracy. In addition, the material is suitable for autoclave sterilization due to resistance to distortion.
Introduction Multiple camera systems are widely used for 3D-motion analysis. Due to increasing accuracies these camera systems gained interest in biomechanical research areas, where high precision measurements are desirable. In the current study different measurement systems were compared regarding their measurement accuracy. Materials and methods Translational and rotational accuracy measurements as well as the zero offset measurements of seven different measurement systems were performed using two reference devices and two different evaluation algorithms. All measurements were performed in the same room with constant temperature at the same laboratory. Equal positions were measured with the systems according to a standardized protocol. Measurement errors were determined and compared. Results The highest measurement errors were seen for a measurement system using active ultrasonic markers, followed by another active marker measurement system (infrared) having measurement errors up to several hundred micrometers. The highest accuracies were achieved by three stereo camera systems, using passive 2D marker points having errors typically below 20 μm. Conclusions This study can help to better assess the results obtained with different measurement systems. With the focus on the measurement accuracy, only one aspect in the selection of a system was considered. Depending on the requirements of the user, other factors like measurement frequency, the maximum analyzable volume, the marker type or the costs are important factors as well.
Minimally invasive surgery is increasingly used in many medical operations because of the benefits for the patients. However, for the surgeons, accessing the situs through a small incision or natural orifice comes with a reduction of the degrees of freedom of the instrument. Due to friction of the mechanical coupling, the haptic feedback lacks sensitivity that could lead to damage of the tissue. The approach of this work to overcome these problems is to develop a control concept for position control and force estimation with shape memory alloys (SMA) which could offer haptic feedback in a novel handheld instrument. The concept aims to bridge the gap between manually actuated laparoscopic instruments and surgical robots. Nickel-titanium shape memory alloys are used for actuation because of their high specific energy density. The work includes the manufacturing of a functional model as a proof of concept comprising the development of a suitable forceps mechanism and electronic circuit for position control and gripping force measurement, as well as designing an ergonomic user interface with haptic force feedback.
In biomechanics, large finite element models with macroscopic representation of several bones or joints are necessary to analyze implant failure mechanisms. In order to handle large simulation models of human bone, it is crucial to homogenize the trabecular structure regarding the mechanical behavior without losing information about the realistic material properties. Accordingly, morphology and fabric measurements of 60 vertebral cancellous bone samples from three osteoporotic lumbar spines were performed on the basis of X-ray microtomography (μCT) images to determine anisotropic elastic parameters as a function of bone density in the area of pedicle screw anchorage. The fabric tensor was mapped in cubic bone volumes by a 3D mean-intercept-length method. Fabric measurements resulted in a high degree of anisotropy (DA = 0.554). For the Young’s and shear moduli as a function of bone volume fraction (BV/TV, bone volume/total volume), an individually fit function was determined and high correlations were found (97.3 ≤ R2 ≤ 99.1,p < 0.005). The results suggest that the mathematical formulation for the relationship between anisotropic elastic constants and BV/TV is applicable to current μCT data of cancellous bone in the osteoporotic lumbar spine. In combination with the obtained results and findings, the developed routine allows determination of elastic constants of osteoporotic lumbar spine. Based on this, the elastic constants determined using homogenization theory can enable efficient investigation of human bone using finite element analysis (FEA).
Biomechanical testing of soft tissues forms the backbone in the experimental validation of tissue engineering and for modelling purposes. The standardized testing of soft tissues requires different experimental protocols and fixtures compared to hard tissues or non-biological materials due to their characteristics. Some of the most commonly-used clamping methods for soft tissue testing affect the tissues' mechanical properties as chemicals are involved to decelerate degradation and autolysis. Moreover, they are unsuitable for standardized and high-throughput testing. Material slippage is also a recurrent unwanted influence on the testing routine with impact on measurement validity. Addressing these issues, this protocol presents a clamping system for simplified testing of biological soft tissues with all necessary components manufactured utilizing 3D printing technology. Templates allow trimming the samples into standardized shapes and sizes while preparation tables facilitate clamping in a fixed distance. The key parts of the system are clamps with a pyramid design, which allow the mounting of biological soft tissues before transferring it into the testing device and minimize material slippage during tensile testing. Flexible holder arms are used to transfer samples from preparation tables into the testing device and simplify positioning. Mechanical testing itself is performed with digital image correlation for precise strain measurements.
Total hip arthroplasty (THA) is a highly successful surgical procedure, but complications remain, including aseptic loosening, early dislocation and misalignment. These may partly be related to lacking training opportunities for novices or those performing THA less frequently. A standardized training setting with realistic haptic feedback for THA does not exist to date. Virtual Reality (VR) may help establish THA training scenarios under standardized settings, morphology and material properties. This work summarizes the development and acquisition of mechanical properties on hip reaming, resulting in a tissue-based material model of the acetabulum for force feedback VR hip reaming simulators. With the given forces and torques occurring during the reaming, Cubic Hermite Spline interpolation seemed the most suitable approach to represent the nonlinear force–displacement behavior of the acetabular tissues over Cubic Splines. Further, Cubic Hermite Splines allowed for a rapid force feedback computation below the 1 ms hallmark. The Cubic Hermite Spline material model was implemented using a three-dimensional-sphere packing model. The resulting forces were delivered via a human–machine-interaction certified KUKA iiwa robotic arm used as a force feedback device. Consequently, this novel approach presents a concept to obtain mechanical data from high-force surgical interventions as baseline data for material models and biomechanical considerations; this will allow THA surgeons to train with a variety of machining hardness levels of acetabula for haptic VR acetabulum reaming.
Orthopedic surgeons endure high physical stresses when performing surgery, as large forces and torques are applied commonly. Occupational risks are consequently higher when compared to other surgical disciplines. One example is the reaming of the acetabula during total hip arthroplasty, using customized instruments. This surgery may predispose the surgeon to overuse-related wrist pathology. In this study, torques acting along the reaming tool were measured, and the resulting forces applied to the orthopedic surgeons' wrists were estimated based on the measured torque data from hip reaming. Different reamer sizes and tool velocities were analyzed to determine how both parameters may influence the torques applied at the surgeon's wrist. Using a highly standardized setup, torques were measured while the reamer was pushed into the acetabula to remove cartilage. Maximum torques and stoppage torques at blocking of the reamer were compared between feed rates and reamer sizes. Peak values of the maximum torques along the reamer axis averaged 1.5-1.8 Nm. No significant difference between maximum torques and reamer sizes was found. A significant difference in maximum torques was noted between feed rates with a large effect (p = 0.010; 112 = 0.214) and a large interaction effect (p = 0.017; 112 = 0.186). Based on this experimental setup, it can be hypothesized that the impulsive behavior of the torque when the milling tool reaches the subchondral lamella could potentially contribute to wrist pathology. These preliminary data warrant further study. Consequently, torque limiters should be implemented in reamers to minimize the risk of occupation-related pathology to the wrist.
Background The FED method (Fixation, Elongation, Derotation) is a treatment method approach to Patients with scoliosis. The FED method is especially established in Spain and Poland, whereby in Germany it is less well- known. Nevertheless the FED method is within the scope of a research project (Project Number: 19200 BR/3). The purpose of the paper is to characterize the FED method and to highlight the specificities in contrast to the Schroth method, which is international established and especially in Germany. Methods This systematic literature research was conducted in Nov 2017-Jan 2018. Therefore common medical and physiotherapeutic databases were used. Furthermore there was a hand search in selected scientific journals. Only a small number of relevant references were identified. That is why the respective authors were asked to provide the full-texts of their papers and to recommend further references. Results A total of 378 references were identified. After removing duplicates and the content-related selection, 19 references were deemed to be relevant. Based on the analysis of this relevant literature, the FED method was comprehensively characterized. First of all the general structure of the FED method and the scientific evidence for its effectiveness was described. And as a result of the literature research, the operating principles of the FED method were pointed out. Then these operating principles were discussed in comparison with the Schroth method. The Schroth method based on sensomotoric and kinesthetic principles and the correction of the pathologic posture was performed by selective muscle activation and breathing-pattern. Thus, the posture correction will be performed by the patients (auto correction). Compared to the Schroth method, the FED method implements the posture correction by the FED-device. This correction is influenced by mechanical forces with a comparatively high strength and intensity. The repetitive mechanical correction stimulates the sensomotoric system. And due to trophic/biochemical adaptations, the physiological bone growth will be stimulated. Conclusion In total the authors want to clarify, that both treatment methods (Schroth method, FED method) supposed to be applied in consideration of the preconditions of the patients and the pursue of the different treatment goals. Thus, the implementation of treatment methods should be used according to the individual treatment demand and on different stages in the treatment process.
Abstract To increase learning success in surgical training, physical simulators are supplemented by measurement technology to generate and record objective feedback and error detection. An opportunity to detect fractures following hip stem implantation early can be measurement of occurring strains on bone surface. These strains can be determined while using strain gauges, digital image correlation (DIC) or photoelasticity. In this research strain gauges and DIC were compared regarding their suitability as strain measurement tools for use in physical simulators. Therefore a testing method was described to replicate the implantation of a hip stem. Testing devices modelled on a realistic prosthesis were pressed into prepared porcine femora in a two-step procedure with a material testing machine. The local strains occurring on bone surface were determined using an optical measurement system for DIC and strain gauges. The initial fractures in the tested femora are located medial-anterior in most cases (73,6%). With increasing indentation depth of the test device, the strains on bone surface increase. Comparing the local strains determined by DIC and strain gauges consistencies in curves are noticeable. Maximal determined strains before fracturing amount to 0,69% with strain gauges and 0,75% with DIC. In the range of the fracture gap, strain gradients are determined by using DIC. However the detected surfaces are of low quality caused by gaps and motion artefacts. The results show strains on bone surfaces for early fracture detection are measurable with strain gauges and DIC. DIC is assessed as less suitable compared to strain gauges. Furthermore strain gauges have greater level of integration and economic efficiency, so they are preferred the use in surgical training simulators.
The sacroiliac joint (SIJ) is burdened with variant loads. However, no methods have allowed to measure objectively how the SIJ deforms during bipedal walking. In this study, in-vivo walking conditions were replicated in a kinematic model combining the finite element method with 3D walking analysis data divided into five phases in order to visualize the load transition on the SIJ and clarify the role of the SIJ. Both models with and without inclusion of the SIJ were investigated. In models with bilateral SIJs, the displacement differed greatly between the sacrum and both hip bones on the SIJ as the boundary. The movements of the sacrum involved a nutation movement in the stance phase and a counter-nutation in the swing phase relative to the ilium. In models without SIJs, the displacement of the pelvis and loads of pelvic ligaments decreased, and the equivalent stress of the SIJs increased compared to the model with SIJs. The walking loads cause distortion of the entire pelvis, and stress concentration at the SIJ are seen due to the morphology of the pelvic ring. However, the SIJs help dissipate the resulting stresses, and the surrounding ligaments are likewise involved in load transmission.
The lumbo-pelvic complex is a highly complex structural system. The current investigation aims to identify the kinematics between interacting bone segments under different loading conditions. A specimen of the lumbo-pelvic complex was obtained from a human body donor and tested in a self-developed test rig. The experimental setup was designed to imitate extension, flexion, right and left lateral bending and axial rotation to the left and to the right, respectively. The vertebra L3 was firmly embedded and load was introduced via hip joints. Using a digital image correlation (DIC) system, the 3D motions of 15 markers at different landmarks were measured for each loadcase under cyclic loading. For each loadcase, the kinematics were analyzed in terms of three-dimensional relative movements between L3 and the sacrum. The usefulness of the experimental technique was demonstrated. It may serve for further biomechanical investigations of relative motion of sacroiliac and vertebral joints and deformation of bony structures.
Vibration measurement and signal analysis methods are common to evaluate the functionality and characteristics of technical components in different industrial and scientific areas. Modal analysis for example is a standard method to characterize the dynamic behavior of a structure and enables the development of validated bone models. The state of the art of analyzing bone structures does not include the modal damping, although it has a significant influence on the dynamic characteristics. Within the presented investigations, the modal analyses have been performed contactless with respect to excitation and response acquisition, which implies that there are no influences of shakers or sensor couplings. Therefore, an automatic impulse hammer and a 3D Scanning Laser Doppler Vibrometer were used for excitation and response detection. Various supports of the test specimens, surface pretreatments, excitation points and excitation impulses were examined to optimize the measurement setup and process. Experimental modal analysis data were analyzed by curve fitting methods to determine the modal parameters. To evaluate different structures and effects of damping, 3D printed artificial bones and animal in vitro bones were used to perform the measurements. To produce the cortical layer of the artificial bone models, volume models were generated based on medical image data and printed by polyamide-based selective laser sintering. The cancellous bone was represented by different foam fillings for the artificial bones. Thereby, the variation of the porosity was achieved by using different mixing ratios of polyurethane foam and hardener. Furthermore, the modal damping parameters were determined from the measurement of animal bones. The measurement time was optimized during the practical implementation of the parameter determination to minimize the influence of drying and decomposition processes on the measurement results.
BACKGROUND The FED method (Fixation, Elongation, Derotation) is a treatment method approach to Patients with scoliosis. The FED method is especially established in Spain and Poland, whereby in Germany it is less well-known. Nevertheless the FED method is within the scope of a research project (Project Number: 19200 BR/3). The purpose of the paper is to characterize the FED method and to highlight the specificities in contrast to the Schroth method, which is international established and especially in Germany. METHODS This systematic literature research was conducted in Nov 2017-Jan 2018. Therefore common medical and physiotherapeutic databases were used. Furthermore there was a hand search in selected scientific journals. Only a small number of relevant references were identified. That is why the respective authors were asked to provide the full-texts of their papers and to recommend further references. RESULTS A total of 378 references were identified. After removing duplicates and the content-related selection, 19 references were deemed to be relevant. Based on the analysis of this relevant literature, the FED method was comprehensively characterized. First of all the general structure of the FED method and the scientific evidence for its effectiveness was described. And as a result of the literature research, the operating principles of the FED method were pointed out. Then these operating principles were discussed in comparison with the Schroth method. The Schroth method based on sensomotoric and kinesthetic principles and the correction of the pathologic posture was performed by selective muscle activation and breathing-pattern. Thus, the posture correction will be performed by the patients (auto correction). Compared to the Schroth method, the FED method implements the posture correction by the FED-device. This correction is influenced by mechanical forces with a comparatively high strength and intensity. The repetitive mechanical correction stimulates the sensomotoric system. And due to trophic/biochemical adaptations, the physiological bone growth will be stimulated. CONCLUSION In total the authors want to clarify, that both treatment methods (Schroth method, FED method) supposed to be applied in consideration of the preconditions of the patients and the pursue of the different treatment goals. Thus, the implementation of treatment methods should be used according to the individual treatment demand and on different stages in the treatment process.