Background: In recent years, sodium-glucose cotransporter-2 (SGLT2) inhibitors have demonstrated significant cardiovascular and renal benefits in patients with heart failure (HF), in addition to their established antidiabetic effects. However, their role in arrhythmia prevention remains unclear. This study aimed to assess the effect of SGLT2 inhibitors on the incidence of supraventricular tachycardia (SVT) and ventricular tachycardia (VT) in patients with HF with reduced ejection fraction (HFrEF) during an extended follow-up period. Methods: This retrospective cohort study was conducted between January 2019 and November 2024 at the Ulm University Heart Center. All patients exhibited severely reduced left ventricular function and underwent primary prophylactic implantable cardioverter-defibrillator (ICD) implantation. Half of the cohort initiated SGLT2 inhibitor therapy alongside optimal medical HF treatment (the SGLT2 group). Patients were followed for approximately three years (846.2 ± 520.0 days) and the incidence of SVT and VT was analyzed using intracardiac Holter records of the ICD. Results: The study population consisted of 78 patients with a mean age of 66.6 ± 12.9 years. Over the follow-up period, a significant prolongation in the time to first occurrence of SVT was observed in the SGLT2 group (Log-Rank p = 0.03), suggesting a potential protective effect of SGLT2 inhibitors. However, regarding VT, additional SGLT2 inhibitor therapy did not show an additional benefit to optimal medical HF treatment. Conclusions: This study suggests that SGLT2 inhibitors may play a beneficial role in reducing the incidence of SVT in patients with HFrEF. These results highlight the importance of further investigating the antiarrhythmic potential of SGLT2 inhibitors through large-scale, prospective studies to better understand their clinical implications and mechanisms of action.
Background/Objectives: Fluoroscopy has traditionally supported three-dimensional (3D) electroanatomical mapping (EAM)-guided left atrial (LA) electrophysiological procedures (EPs), but the associated ionizing radiation poses long-term health risks for patients and healthcare professionals. Advances in 3D EAM systems now enable nearly or entirely radiation-free ablations. Imaging techniques such as transesophageal echocardiography (TEE) are increasingly used for precise and safe LA access. This study evaluates the safety and efficacy of TEE-guided, zero-fluoroscopy/near-zero-fluoroscopy LA EPs in routine clinical practice. Methods: 142 consecutive patients undergoing LA EAM-guided radiofrequency ablation at the Ulm University Heart Center between October 2023 and November 2024 were analyzed. In total, 73 patients underwent zero-fluoroscopy/near-zero-fluoroscopy ablation guided solely by TEE, while another 69 patients received fluoroscopy-guided ablation using TEE and fluoroscopy guidance. Results: Of the 142 patients, 58.0 (40.8%) were female, and the median age was 73.0 (64.0; 79.0) years. A total of 53 (37.3%) underwent zero-fluoroscopy EP, 20 (14.1%) underwent near-zero-fluoroscopy EP, and 69 (48.6%) underwent fluoroscopy-guided EP. Procedure duration was without significantly relevant difference between both groups (132.0 vs. 133.0 min; p = 0.52). Median radiation exposure in the zero-fluoroscopy/near-zero-fluoroscopy group was 0 (0.0; 0.0) minutes, compared to significantly higher values in the fluoroscopy group (9.7 (5.9; 15.3) minutes; p < 0.001). No significant differences in complications were observed (p = 0.09). Conclusions: TEE-guided, radiation-free LA EP offers a safe and effective approach, significantly reducing radiation exposure and its associated risks while maintaining high procedural efficacy without increasing the risk of complications.
Background: The purpose of this retrospective study was to evaluate the value of contrast-enhanced computed tomography (CE-CT) image features at baseline and after neoadjuvant chemotherapy in predicting histopathological response in patients with adenocarcinoma of the gastroesophageal junction (GEJ). Methods: A total of 105 patients with a diagnosis of adenocarcinoma of the GEJ were examined by CE-CT at baseline and preoperatively after neoadjuvant chemotherapy. All patients underwent surgical resection. Histopathological parameters and tumor regression grading according to Becker et al. were collected in 93 patients. Line profiles of the primary tumor area in baseline and preoperative CE-CT were generated using ImageJ. Maximum tumor density and tumor-to-wall density delta were calculated and correlated with the histopathological tumor response. In addition, tumor response was assessed according to standard RECIST measurements in all patients and by endoscopy in 72 patients. Results: Baseline and change in baseline to preoperative CE-CT parameters showed no significant differences between responders (Becker grade 1a, 1b) and non-responders (Becker grade 2, 3). After neoadjuvant therapy, responders and non-responders showed significant differences in maximum density and tumor-to-wall density delta values. Line profile measurements showed excellent inter-rater agreement. In comparison, neither RECIST nor endoscopy showed significant differences between these groups. Conclusions: Posttreatment CE-CT can predict histopathological therapy response to neoadjuvant treatment in adenocarcinoma of GEJ patients with high accuracy and thus may improve patient management.
Abstract Background ST-elevation myocardial infarction (STEMI) demands near-time reperfusion to reduce the risk of long-term heart failure. This study evaluates the proportion of impaired left ventricular ejection fraction (LVEF) following STEMI in the context of current healthcare settings at a tertiary care center equipped with the most advanced and up-to-date standards of care. Methods Patients experiencing STEMI as their first manifestation of coronary artery disease were analyzed, as these individuals had no prior experience with heart-related chest pain. LVEF was assessed by levocardiography at admission and semiautomatically using TOMTEC in patients with eligible full-cycle echocardiography of 2- and 4-chamber view available at discharge and 1-year follow-up (FU). Pain-to-balloon time was divided into quartiles (Q) [0-111, 112–159, 160–246 and 247–784 min]. Multiple logistic regression analysis identified independent predictors of reduced LVEF < 50% at 1-year FU. Results A total of 1,379 consecutive STEMI patients were reviewed from 2010 to 2017, with 130 meeting the inclusion criteria. Mean age was 63 ± 12 years, 75% were male, 14% had diabetes, 72% had arterial hypertension, and 56% had history of smoking. LVEF was reduced in 94% of patients at admission, 69% at discharge, and remained reduced in 45% at the 1-year follow-up. Anterior wall myocardial infarction (OR 3.2 [95%-CI 1.2–6.9], p = 0.018) and increasing pain-to-balloon time across quartiles (Q2: OR 15.7 [95%-CI 1.8–140.4], p = 0.014; Q4: OR 33.7 [3.4–278.7] p = 0.002) were independently associated with reduced LVEF at 1 year. Conclusion Despite optimal medical management and advanced healthcare structures, nearly half of patients with STEMI as their first presentation of coronary artery disease continue to exhibit reduced LVEF at 12-months. Anterior wall myocardial infarction and pain-to-balloon time exceeding 2 h remain independent predictors of left ventricular dysfunction. Further improvements in healthcare systems and public education are essential to reduce treatment delays and improve long-term outcomes.
Background: Pulmonary vein isolation (PVI) is the standard of care for the treatment of symptomatic atrial fibrillation (AF). Novel techniques for PVI are the thermal size-adjustable cryo-balloon (CB) system and non-thermal pulsed field ablation (PFA) system. There are currently no data available for a direct comparison between these two systems. Furthermore, with new techniques, it is important to ensure a high level of efficiency and safety during treatment right from initial use. Therefore, the aim of this study was to directly compare the procedural data and safety of these two new PVI techniques in first-time users. Methods: We conducted a single-center prospective study involving 100 consecutive patients with symptomatic atrial fibrillation who underwent first-time PVI using either size-adjustable CB PVI or PFA PVI from July 2023 to March 2024. Results: Acute PVI was achieved in 100% of patients in both groups. First-pass isolation (FPI) was more frequently achieved in the PFA group compared to the size-adjustable CB group. The mean procedural duration and fluoroscopy dose were significantly shorter in the PFA cohort (p < 0.001). Furthermore, a significant reduction in fluoroscopy time was observed during the learning curve within the PFA group (p = 0.023). There were no major complications in both groups. Conclusions: Both systems demonstrate good effectiveness and safety during PVI performed by first-time users. However, the PFA group exhibited a significantly shorter procedural duration.
Background: Pulsed field ablation (PFA) represents a novel non-thermal approach for treating atrial fibrillation (AF) through pulmonary vein isolation (PVI). By utilizing irreversible electroporation, PFA creates lesions with minimal impact on adjacent tissues. This study investigates the procedural outcomes and safety of a novel circular PFA catheter in comparison to an established PFA system in a real-world clinical setting. Methods: This prospective, single-center study enrolled 125 consecutive patients with symptomatic paroxysmal or persistent AF undergoing first-time PVI with PFA at Ulm University Heart Center. Twenty-five patients underwent PFA PVI using a novel PFA system (PulseSelectTM, Medtronic, Dublin, Ireland) which incorporates a new circular catheter design and additional features such as ECG-triggered energy application and phrenic nerve capture testing. In comparison, 100 patients were treated using the established PFA system (FarapulseTM, Boston Scientific, Marlborough, MA, USA). Results: Acute PVI was achieved in 100% of the patients. Procedure duration, total left atrial (LA) time and fluoroscopy time remained comparable between both groups. The total number of energy deliveries was higher with the novel circular PFA catheter (34.0 vs. 32.0; p < 0.001). No procedure-related complications, including pericardial tamponade, phrenic nerve injury, atrial-esophageal fistula, vascular complications, embolisms, malignant cardiac arrhythmias, or coronary spasms were observed. Conclusions: The novel and the established PFA systems demonstrated comparable results in terms of procedure duration, fluoroscopy time, and LA time. In the hands of experienced operators, the novel circular PFA system enables an effective, consistent, and safe approach to successful PFA PVI.
Background: Complex arrhythmias often arise from the left side of the heart, necessitating established electrophysiological (EP) procedures like 3D-mapping-assisted radiofrequency (RF) ablations or pulmonary vein isolation (PVI). These procedures typically require transseptal access, emphasizing the critical role of achieving an optimal catheter position through a precise transseptal puncture (TSP). Commonly employed imaging methods for TSP guidance include fluoroscopy and interventional echocardiography. Despite their routine use, there is limited evidence on which imaging modality offers superior catheter positioning for EP procedures, and safety concerns regarding transseptal punctures with imaging remain underexplored. This study aims to systematically evaluate the feasibility, safety, and accuracy of echo-guided TSP compared to fluoroscopy-guided TSP. Methods: In this prospective study, 150 consecutive patients undergoing left atrial EP procedures were enrolled between October 2023 and February 2024 at the Ulm University Heart Center. Following optimal fluoroscopy-guided transseptal needle positioning at the interatrial septum, the catheter placement was further verified using transesophageal echocardiography (TEE). Adjustments were made in cases of suboptimal needle positioning observed in TEE. The fluoroscopically achieved septal positions were categorized based on TEE images as optimal, suboptimal, poor, or dangerous. Results: Among the 150 patients included (58.0% male), fluoroscopy achieved optimal, suboptimal, and poor/dangerous positions in 32.7%, 43.3%, and 24.0%, respectively. After TEE-guided adjustments, optimal and suboptimal positions were achieved in 59.3% and 40.7% of patients, respectively. No instances of poor or dangerous transseptal needle positions were observed under TEE guidance. Conclusions: TEE-guided TSP emerges as a feasible, more accurate, and safer imaging method for transseptal punctures in EP procedures.
The field of interventional electrophysiology is rapidly growing. For safe and efficient procedures sedation is needed for patient comfort and immobility. However, sedative and analgesic agents can induce respiratory depression, risking hypercapnia, hypoxia, and hypotension. This study evaluates the impact of adding transcutaneous carbon-dioxide (CO2) monitoring to standard monitoring practices in electrophysiological procedures under deep sedation. This prospective, randomized study at Ulm University Heart Center included 726 patients undergoing treatment under deep sedation between August 2019 and October 2023. Patients were randomly assigned to standard monitoring or standard monitoring with continuous transcutaneous CO2 monitoring (TCM-group). Standard monitoring involved non-invasive blood pressure, oxygen saturation (SpO2), and frequent peripheral venous blood gas analysis. The primary composite endpoint was SpO2 dips below 90
Background/Objectives: Single-shot devices are important tools for efficient pulmonary vein isolation (PVI) in atrial fibrillation (AF). In addition to the standard cryo-balloon (CB) catheter, a novel multi-electrode radiofrequency balloon-catheter (RFB, Heliostar, Biosense Webster, Irvine, CA, USA) with 3D-mapping-integration is available. Currently, there is no evidence allowing for a direct comparison between RFB-PVI and CB-PVI in a matched population. The study aimed to assess the procedural data, safety profiles, and outcomes of RFB-PVI versus CB-PVI. Methods: In this prospective registry study, symptomatic AF patients undergoing first-time PVI from January 2019 to April 2023, using RFB or CB, were included, with patients matched in a 1:2 ratio to reduce potential confounders. Results: The results from 171 consecutive RFB patients and 342 matched CB patients showed comparable recurrence-free survival after 12 months (81.3% RFB vs. 76.8% CB, p = 0.359). The RFB group had a longer procedure duration (88 vs. 73 min, p < 0.001) and longer fluoroscopy time (18.9 vs. 14.5 min, p < 0.001). Conclusions: In conclusion, the novel RFB system enables efficient and safe PVI, which is broadly comparable to the established CB system. However, the 3D-mapping integration in RFB did not reduce fluoroscopy time compared to CB.
Background: Cavotricuspid isthmus (CTI)-dependent atrial flutter (AFL) is the most common atrial macro-reentrant tachycardia, characterized by a typical ECG pattern (type I ECG). Often, tachycardia terminates before it can be confirmed by an electrophysiological study (EPS), necessitating CTI ablation in sinus rhythm (SR). This study aims to compare the success rate of CTI ablation in patients with type I ECG during SR versus ongoing CTI-dependent AFL, focusing on arrhythmia recurrence. Methods: We screened patients at Ulm University Heart Center from January 2010 to November 2020 with type I ECG who underwent CTI ablation. Patients were divided into two groups: those whose tachycardia terminated before EPS and underwent ablation in SR, and those with ongoing CTI-dependent AFL during EPS. CTI ablation was deemed complete when a bidirectional conductance block was achieved, confirmed after 30 min. Results: A total of 230 patients were included, all showing typical AFL in ECG recordings. Of these, 67 patients underwent ablation in SR, while 163 were ablated during ongoing AFL. The median follow-up time was 2.7 years. Recurrence of CTI-dependent AFL occurred in 8.3% of patients: 4.5% in the SR ablation group and 9.8% in the ongoing AFL group. Kaplan–Meier estimation showed similar efficacy for both methods regarding arrhythmia recurrence (log-rank p = 0.07). Conclusions: Our decade-long study indicates that CTI ablation during SR is as effective as ablation during ongoing CTI-dependent AFL in achieving long-term freedom from arrhythmia. This research supports the efficacy of both techniques in clinical settings, validating a widely practiced approach.
Background: Pulmonary vein isolation (PVI) is a common therapeutic approach for symptomatic atrial fibrillation (AF). Among various techniques, cryo-balloon (CB) PVI is widely adopted, but, to date, established CB systems have had fixed balloon sizes. A novel size-adjustable CB, allowing balloon size adjustments during ablation, lacks sufficient data on optimal utilization in patient care. This study aims to systematically investigate this feature with a tailored ablation protocol. Methods: Our single-center prospective study included patients with paroxysmal or persistent atrial fibrillation undergoing first-time PVI with the size-adjustable CB from July 2023 to February 2024. Ablation was performed using the balloon size that provided better occlusion. The ablation protocol involved an initial occlusion test with the small balloon size (28 mm). If optimal occlusion (occlusion level 4) could not be achieved, an attempt with the larger balloon (31 mm) was initiated. Ablation was conducted using the balloon configuration that provided better occlusion of the pulmonary vein ostium. Results: Our prospective study includes 50 patients (median age [interquartile range, IQR]: 72 [65; 79] years, 24 [48.0%] females, and 35 [70.0%] patients with paroxysmal AF). The median procedure duration (IQR) was 77 (65; 96) minutes, and the median fluoroscopy time (IQR) was 17.7 (12.5; 22.0) min. PVI was successfully accomplished in each treated pulmonary vein (PV), with 87.4% of PVs isolated during the first freeze. The large balloon configuration was used to isolate 16.8% of PVs. Conclusions: The utilization of the size-adjustable CB, combined with the presented tailored ablation workflow, appears to facilitate effective and efficient pulmonary vein isolation. The use of a larger balloon configuration appears beneficial in isolating a significant proportion of the PVs.
Pulmonary vein isolation (PVI), as the cornerstone of atrial fibrillation (AF) ablation, has emerged a widely used therapy for patients suffering from AF. To improve PVI efficiency, single-shot catheters (SSCs) have been developed. Regrettably, SSCs are not integrated into 3D-mapping technology. In that regard, a novel radiofrequency balloon catheter (RFBC, Heliostar, Biosense Webster) with full integration into 3D-mapping technology has been developed. The aim of this study was to assess operative and follow-up outcomes of the RFBC in AF patients. In this monocentric prospective registry, patients with a first-time PVI using the RFBC were included. Follow-up visits were scheduled 3, 6, 12 and 24 months after ablation and in case of symptoms. A total of 171 patients (36.8% female) were included, with a mean age of 68.5 ± 10.2 years. Among them, 63 patients (36.8%) presented with persistent AF. Notably, no major periprocedural complications were observed. The mean follow-up period was 287 ± 157 days. In the Kaplan–Meier analysis, the estimated recurrence-free survival after 12 months was 81.8%. Based on our data, PVI with the fully 3D-mapping-integrated RFBC seems to be safe and effective and to have a favorable 12-month outcome in patients with paroxysmal and persistent AF.
The incidence of left atrial (LA) supraventricular arrhythmias is increasing. Even after LA ablation, recurrence of these tachycardias is common. MRI studies show that LA cardiomyopathy is a significant risk factor for recurrence and correlates with low voltage areas detected via 3D electroanatomic mapping (EAM). There are limited data on the impact of low voltage extent detected by EAM on recurrence-free survival. Voltage thresholds defining low voltage vary across different studies. This study aims to investigate the impact of the extent of low voltage areas in the LA on recurrence-free survival and to assess whether defining low voltage areas using thresholds of 0.5, 0.4, or 0.3 mV offers better predictive performance. Patients with atrial arrhythmia who underwent LA EAM at Ulm University Heart Center between September 2018 and September 2022 were included from the ATRIUM registry. ROC analysis determined the voltage threshold for predicting recurrence-free survival. Kaplan–Meier and logistic regression models adjusted for patient variables were used to analyze recurrence-free survival. Of 1089 screened patients, 108 met the inclusion criteria. ROC analysis indicated that a 0.4 mV threshold for low voltage provided the best predictive performance. Logistic regression showed a 1.039-fold increase in recurrence risk per percent increase in LA low voltage area (odds ratio = 1.039, 95% CI 1.014–1.064). Low voltage extent in EAM correlates with 1-year recurrence rate after ablation of left atrial supraventricular arrhythmias. The threshold of 0.4 mV is the most suitable for predicting recurrences of those examined.
Background: Transseptal puncture (TSP) is a critical step in electrophysiological (EP) procedures, as a misdirected TSP can result in life-threatening complications. Although TSP is predominantly performed under fluoroscopic guidance in EP procedures, transesophageal echocardiography (TEE) offers more precision and certainty in the localization of the transseptal needle at the interatrial septum. Despite the widespread use of TSP, evidence supporting the added value of TEE-guided TSP in EP procedures remains limited. This study evaluates the impact of additional TEE guidance on TSP-associated complications during EP procedures. Methods: This study enrolled patients who underwent left atrial or left ventricular procedures with TSP, performed either without (fluoroscopy group) or with additional TEE guidance (TEE group), at the University Heart Center Ulm, Germany. Results: A total of 932 patients were included: 443 in the TEE group (mean age 68.1 ± 11.8 years, 40.6% female) and 489 in the fluoroscopy group (mean age 68.8 ± 11.0 years, 38.2% female). The mean number of transseptal accesses per patient was 1.18 ± 0.38 in the TEE group and 1.14 ± 0.34 in the fluoroscopy group (p = 0.101). Pericardial tamponade occurred significantly less in the TEE group (0.5%) than in the fluoroscopy group (1.8%; p = 0.046). Logistic regression revealed a 91.8% lower risk of pericardial tamponade with TEE-guided TSP compared to fluoroscopy guidance alone. The overall TEE complication rate was low (0.9%). Conclusions: TEE guidance during TSP significantly reduces the risk of pericardial tamponade in EP procedures, indicating that TSP should be performed with additional sonographic guidance to increase patient safety.
Background: In electrophysiological procedures, multiple punctures on the femoral vein can be necessary depending on the number of catheters required. The femoral vein is typically located indirectly by using its anatomical relationship to the artery as a reference. However, this conventional approach can lead to significant complications, including bleeding, peri-interventional transfusion, pseudoaneurysms, or arteriovenous fistulas. Despite these risks, there is limited evidence comparing the safety of ultrasound-guided venipuncture versus the conventional technique in electrophysiological procedures. Objective: This study aimed to evaluate the impact of ultrasound-guided venipuncture on vascular access complications in electrophysiological procedures and to identify associated risk factors. Methods: In this single-center trial, patients scheduled for electrophysiological procedures at Ulm University Heart Center, Germany, were enrolled between November 2021 and October 2023. Venipuncture in the groin was performed using either the conventional or an ultrasound-guided approach. The primary composite endpoint was defined as peri-interventional major vascular access complications (Bleeding Academic Research Consortium (BARC) ≥2 bleeding, pseudoaneurysms, arteriovenous fistulas, and peri-interventional transfusion) and minor complications (BARC 1). Results: A total of 1370 patients were included: 749 in the conventional group and 621 in the ultrasound group. The primary endpoint was achieved in 19.2% of the conventional group and 12.1% of the ultrasound group (p < 0.001). An increased sheath diameter and a higher number of venous accesses were identified as risk factors for the primary endpoint. Conclusions: Ultrasound guidance for venous groin puncture in electrophysiological procedures reduces access-related complications, supporting its use with careful attention to sheath size and number.
Abstract Background Cryoballoon pulmonary vein isolation (PVI) is an established anatomical single-shot procedure for the treatment of atrial fibrillation (AF). Purpose We compared efficiency of two commercially available cryoballoon ablation systems (CBS) to treat AF. Methods We prospectively enrolled 121 consecutive AF patients and treated them with either a compliant or a non-compliant CBS. Results Evaluation of procedural characteristics revealed a significantly longer procedure duration (p=0.007) and fluoroscopy time (p=0.008) in the group of the compliant CBS. The nadir cryoballoon temperature was lower using the compliant system compared to the non-compliant CBS (p<0.0001), likewise the time to isolation was not different between both groups. The non-compliant CBS showed a better occlusion for the right superior pulmonary vein (RSPV, p=0.039) leading to a higher rate of isolation with first freeze (p=0.004) and lower number of ablations at the RSPV (p=0.015). A mean follow-up period of 310.8±189.7 days within a 90-day blanking period. 68% of patients treated with the non-compliant and 65% of patients treated with the compliant CBS showed freedom from atrial arrhythmia recurrence (p=0.724). Kaplan-Meier estimation showed no significant difference between both groups (LogRank p=0.768). Conclusion The novel compliant CBS showed a longer procedure duration and fluoroscopy time, as well as, a lower nadir cryoballoon temperature. The non-compliant CBS was more effective in isolation of the RSPV. Acute PVI success and long-term freedom from atrial arrhythmia recurrence after a mean follow-up of ten months did not differ between groups.
For patients with symptomatic atrial fibrillation (AF) pulmonary vein isolation (PVI) has evolved to the standard of care. For minimization of pulmonary vein reconnection, for reduction of complications and for improvement of PVI efficiency, also in a timely manner, many catheter technologies have been developed already. A new ablation modality in that regard is the radiofrequency balloon-catheter (RF-BC). However the evidence concerning this new technology is sparse.
Previous clinical studies on pulmonary vein isolation (PVI) with radiofrequency balloons (RFB) reported safe and effective procedures for a 20 s RF delivery via posterior electrodes. Recent recommendations from the manufacturer suggest reducing the application time to 15 s on the posterior wall (PW) when facing the esophagus region. Here, we retrospectively assess whether 15 s of RF delivery time on posterior electrodes is safe while still ensuring lesion metrics of sufficient quality. This retrospective study included 133 patients with paroxysmal and persistent atrial fibrillation who underwent PVI using an RFB (Heliostar, Biosense Webster, Inc., Irvine, CA, USA) at two European centers. The ablation protocol was set for an RF duration of 20 s/60 s for the posterior/anterior electrodes. A multielectrode temperature probe was systematically used. In the case of an esophageal temperature rise (ETR) above 42 °C (ETR+), an endoscopic evaluation was performed. All posterior electrode lesion metric dynamics (temperature (T) and impedance (Z)) were collected from the RFB generator and analyzed offline. In total, 2435 posterior electrode applications were analyzed. With an RF delivery of 19.8 (19.7–19.8) s, the median impedance drop was 18.4 (12.2–25.2) Ω, while the temperature rise was 11.1 (7.1–14.9) °C. Accordingly, impedance (84.6 (79.3–90.2) Ω) and temperature plateaus (38 (35.3–41.1) °C) were reached at 13.9 (10.6–16) s and 16.4 (12.6–18.5) s, respectively. Overall, 99.6% and 95.8% of electrodes reached 90% (16.6 Ω) and 95% (17.5 Ω) of their impedance drops within 15 s of RF delivery, while 97.2% and 92.8% achieved 90% (34.2 °C) and 95% (36.1 °C) of their temperature rise to reach the plateaus within 15 s of RF delivery. An ETR >42 °C occurred in 37 (30.1%) patients after 17.7 ± 2.3 s of RF delivery. In the ETR+ group, the impedance drop and temperature rise on the posterior electrodes were higher compared to patients where ETR was <42 °C. Two asymptomatic thermal esophageal injuries were observed. In conclusion, 15 s of RF delivery on the posterior electrodes provides a good balance between safety, with no esophageal temperature rise, and efficacy with high-profile lesion metrics.