Abaqus numerical simulation was carried out for the aluminum honeycomb-polyurethane composite waterproof bottom plate and wall plate used in the prefabricated integral bathroom in the enterprise incubation base project of Sanya Central Business District.Taking the construction and use situation into full consideration,the uniform load was used to simulate the static position of large equipment and the concentrated load was used to simulate the situation of single point hanging heavy objects.The stress distribution,displacement distribution,maximum stress and maximum displacement under the concentrated load of 20 t·m-2 and 800 kN are analyzed.
Taking ordinary mortar as the research object,after standard curing and absolute wet curing for 3 d,7 d and 28 d,the mortar was subjected to high temperature treatment at 300℃,500℃and 700℃,respectively.After cooling,the mechanical properties of mortar test blocks were tested to study the effects of curing method,age and treatment temperature on mechanical properties of mortar test blocks.The test results show that with the increase of treatment temperature,the fracture resistance and compressive strength of mortar test block decrease continuously,and the earlier the age,the greater the effect of temperature.In addition,the mechanical properties of the absolute wet curing blocks were smaller than those of the standard curing blocks.
The traditional design of subsea structures pays more attention to the analysis of structural elements under normal operation,while more advanced methods are needed to deal with sudden conditions.The finite element method based on the Coupled Eulerian-lagrangian(CEL)method can efficiently deal with the transient and large deformation problems.Therefore,this method is used to simulate the collision between the liquid storage tank falling into water and the underwater structure,and the results are analyzed and discussed.
Based on the restraint mechanism of FRP-constrained concrete cylinder,the type,structure,characteristics and influencing factors of stress and strain models of FRP restraint concrete were analyzed,and then the lateral restraint and lateral expansion coefficient of restraint concrete were discussed.
Combined with the preparation method of modified aerogel,the thermal insulation coating based on polymer modified SiO2 aerogel was prepared,and the performance of modified aerogel and the thermal insulation performance of the coating were tested.The results showed that the modification scheme was feasible.