The anisotropic mechanical properties of fiber-embedded biological tissues are essential for understanding their development, aging, disease progression, and response to therapy. However, accurate and fast assessment of mechanical anisotropy in vivo using elastography remains challenging. To address the dilemma of achieving both accuracy and efficiency in this inverse problem involving complex wave equations, we propose a computational framework that utilizes the traveling wave expansion model. This framework leverages the unique wave characteristics of transversely isotropic material and physically meaningful operator combinations. The analytical solutions for inversion are derived and engineering optimization is made to adapt to actual scenarios. Measurement results using simulations, ex vivo muscle tissue, and in vivo human white matter validate the framework in determining in vivo anisotropic biomechanical properties, highlighting its potential for measurement of a variety of fiber-embedded biological tissues.
Interventional MRI (i-MRI) has been used for improving the accuracy and safety of brain intervention. The surgical navigation system that provides guidance before and during the intervention is crucial for the operation, especially for robot-assisted neurosurgery. Here we present a Surgical Planning for Brain Intervention (SPBI) software system. SPBI provides a series of functionalities to improve the safety and precision of brain intervention, including brain tissue segmentation, vessel segmentation, fiber tracking, and intervention path planning. Multimodal brain MR images from healthy volunteers were used for demonstration of the functionalities. Codes and sample data are open-sourced and publicly available.
Stereotactic neurointervention is a common procedure for biopsy, injection, ablation, and implantation of electrodes for deep brain stimulation. Guided by preoperative imaging, conventional approaches are mostly performed manually, lacking operation stability and interactive feedback. The intraoperative magnetic resonance imaging (MRI) guidance enables both structural and functional assessment during operation, permitting interactive adaptation to tissue deformation and avoidance of critical anatomical regions. Here, we report an MRI-guided robotic system for stereotactic neurointervention. A macro-micro hybrid pneumatic-hydraulic actuated stereotactic robot with a large range of motion and high precision is developed. This is coupled with a compact bioinspired soft actuator for target intervention. A global-focal MRI sequence is proposed for interactive navigation, closed-loop control, and precise targeting. Validation is performed with phantom, cadaveric, and in vivo animal studies, showing positional accuracies of 0.39, 0.68, and 0.14 millimeters, respectively, demonstrating superior performance compared to the current state of the art in robotic-assisted stereotactic neurointervention.
Magnetic resonance elastography (MRE) of brain relies on inducing and measuring shear waves in the brain. However, studies have shown vibration could induce changes in cerebral blood flow (CBF), which has a modulation effect and can affect the biomechanical properties measured. Objective: This work demonstrates the initial prototype of the indirect excitation method, which can generate shear waves in the brain with minimal changes in CBF. Methods : A simple system was designed to produce stable vibrations underneath the neck. Instead of directly stimulating the skull, shear waves were indirectly transmitted to the brain through the spine and brainstem. Results : Phantom results showed that the proposed actuator did not interfere with the routine imaging sequence and successfully generated multifrequency shear waves. When compared with the conventional direct head stimulation method, brain MRE results from the proposed actuator showed no significant differences in terms of intraclass correlation coefficients (ICC) and coefficients of variation (CV). Moreover, the octahedral shear strain (OSS) generated by the indirect excitation in the frontal and parietal lobes decreased by 25.96% and 16.73% respectively. Evaluation of CBF in healthy volunteers revealed no significant changes for the indirect excitation method, whereas significant decreases in CBF were observed in four subregions when employing direct excitation. Conclusion : The proposed actuator offers a more accurate and comfortable approach to MRE measurements while causing minimal CBF alterations. Significance : This work presents the first demonstration of an indirect excitation brain MRE system that minimizes CBF changes, thus holding potential for future applications of brain MRE.
Human brain experiences vibration of certain magnitude and frequency during various physical activities such as vehicle transportation and machine operation, which may cause traumatic brain injury or other brain diseases. However, the mechanisms of brain pathogenesis due to vibration are not fully elucidated due to the lack of techniques to study brain functions while applying vibration to the brain at a specific magnitude and frequency. Here, this study reported a custom-built head-worn electromagnetic actuator that applied vibration to the brain in vivo at an accurate frequency inside a magnetic resonance imaging scanner while cerebral blood flow (CBF) was acquired. Using this technique, CBF values from 45 healthy volunteers were quantitatively measured immediately following vibration at 20, 30, 40 Hz, respectively. Results showed increasingly reduced CBF with increasing frequency at multiple regions of the brain, while the size of the regions expanded. Importantly, the vibration-induced CBF reduction regions largely fell inside the brain's default mode network (DMN), with about 58 or 46% overlap at 30 or 40 Hz, respectively. These findings demonstrate that vibration as a mechanical stimulus can change strain conditions, which may induce CBF reduction in the brain with regional differences in a frequency-dependent manner. Furthermore, the overlap between vibration-induced CBF reduction regions and DMN suggested a potential relationship between external mechanical stimuli and cognitive functions.
Accurate navigation and targeting are critical for neurological interventions including biopsy and deep brain stimulation. Real-time image guidance further improves surgical planning and MRI is ideally suited for both pre- and intra-operative imaging. However, balancing spatial and temporal resolution is a major challenge for real-time interventional MRI (i-MRI). Here, we proposed a deep unrolled neural network, dubbed as LSFP-Net, for real-time i-MRI reconstruction. By integrating LSFP-Net and a custom-designed, MR-compatible interventional device into a 3 T MRI scanner, a real-time MRI-guided brain intervention system is proposed. The performance of the system was evaluated using phantom and cadaver studies. 2D/3D real-time i-MRI was achieved with temporal resolutions of 80/732.8 ms, latencies of 0.4/3.66 s including data communication, processing and reconstruction time, and in-plane spatial resolution of 1 × 1 mm 2 . The results demonstrated that the proposed method enables real-time monitoring of the remote-controlled brain intervention, and showed the potential to be readily integrated into diagnostic scanners for image-guided neurosurgery.
Magnetic Resonance Imaging (MRI) is now a widely used modality for providing multimodal, high-quality soft tissue contrast images with good spatiotemporal resolution but without subjecting patients to ionizing radiation. In addition to its diagnostic potential, its future theranostic value lies in its ability to provide MRI-guided robot intervention with combined structural and functional mapping, as well as integrated instrument localization, target recognition, and in situ, in vivo monitoring of the therapeutic efficacy. Areas of current applications include neurosurgery, breast biopsy, cardiovascular intervention, prostate biopsy and radiotherapy. Emerging applications in targeted drug delivery and MRI-guided chemoembolization are also being pursued. Whilst promising progress has been made in recent years, there are still significant basic science research and engineering challenges. This paper provides a comprehensive review of the current state-of-the-art in MRI-guided robot intervention and allied technologies in actuation, sensing, new materials, interventional instruments, and interactive/real-time MRI. Potential future research directions and new clinical developments are also discussed.
Objective: Interventional MRI (i-MRI) is crucial for MR image-guided therapy. Current image reconstruction methods for dynamic MR imaging are mostly retrospective that may not be suitable for real-time i-MRI. Therefore, an algorithm to reconstruct images without a temporal pattern as in dynamic imaging is needed for i-MRI. Methods: We proposed a low-rank and sparsity (LS) decomposition algorithm with framelet transform to reconstruct the interventional feature with a high temporal resolution. Different from the existing LS-based algorithms, the spatial sparsity of both the low-rank and sparsity components was used. We also used a primal dual fixed point (PDFP) method for optimization of the objective function to avoid solving sub-problems. Intervention experiments with gelatin and brain phantoms were carried out for validation. Results: The LS decomposition with framelet transform and PDFP could provide the best reconstruction performance compared with those without. Satisfying reconstruction results were obtained with only 10 radial spokes for a temporal resolution of 60 ms. Conclusion and Significance: The proposed method has the potential for i-MRI in many different application scenarios.
Interventional magnetic resonance imaging (i-MRI) for surgical guidance could help visualize the interventional process such as deep brain stimulation (DBS), improving the surgery performance and patient outcome. Different from retrospective reconstruction in conventional dynamic imaging, i-MRI for DBS has to acquire and reconstruct the interventional images sequentially online. Here we proposed a convolutional long short-term memory (Conv-LSTM) based recurrent neural network (RNN), or ConvLR, to reconstruct interventional images with golden-angle radial sampling. By using an initializer and Conv-LSTM blocks, the priors from the pre-operative reference image and intra-operative frames were exploited for reconstructing the current frame. Data consistency for radial sampling was implemented by a soft-projection method. To improve the reconstruction accuracy, an adversarial learning strategy was adopted. A set of interventional images based on the pre-operative and post-operative MR images were simulated for algorithm validation. Results showed with only 10 radial spokes, ConvLR provided the best performance compared with state-of-the-art methods, giving an acceleration up to 40 folds. The proposed algorithm has the potential to achieve real-time i-MRI for DBS and can be used for general purpose MR-guided intervention.
Characterization of biomechanical properties of soft biological tissues is important to understand the tissue mechanics and explore the biomechanics-related mechanisms of disease, injury, and development. The mechanical testing method is the most straightforward way for tissue characterization and is considered as verification for in vivo measurement. Among the many ex vivo mechanical testing techniques, the indentation test provides a reliable way, especially for samples that are small, hard to fix, and viscoelastic such as brain tissue. Magnetic resonance elastography (MRE) is a clinically used method to measure the biomechanical properties of soft tissues. Based on shear wave propagation in soft tissues recorded using MRE, viscoelastic properties of soft tissues can be estimated in vivo based on wave equation. Here, the viscoelastic properties of gelatin phantoms with two different concentrations were measured by MRE and indentation. The protocols of phantom fabrication, testing, and modulus estimation have been presented.
Human brain experiences vibration of certain frequency during various physical activities such as vehicle transportation and machine operation or accidents, which may cause traumatic brain injury or other brain diseases. However, little is known about what happened to brain after vibration stimuli. Here, with a custom-built electromagnetic actuator, vibration was induced in the brain while cerebral blood flow (CBF) and brain stiffness were measured at 20, 30, 40 Hz for 52 healthy volunteers. With increasing frequency, multiple regions of the brain showed increasingly reduced CBF, while the size of such regions also expanded. The vibration-induced CBF reduction regions largely fell inside the brain’s default mode network (DMN), with about 58 or 46 % overlap at 30 or 40 Hz, respectively. By establishing a biomechanical co-variance network based on tissue stiffness, analysis of small-world properties and modularity showed an increased disruption of the network with increased frequency. These findings demonstrate frequency-dependent features of vibration modulation to brain. Furthermore, the overlap between CBF reduction regions and DMN, and the vibration-induced decrease of biomechanical network connections suggest a interweaved relationship between blood flow, tissue stiffness, and cognitive functions. These may provide critical insights into the mechanical stimulus to brain and vibration-induced brain pathologies.
目的实时磁共振的引导可提高脑组织穿刺活检和DBS电极植入等神经介入手术的精度。磁共振扫描仪的磁孔空间较为狭小,限制了在实时磁共振引导下进行手术,采用电机、液压、气动和超声等方式可远程驱动完成介入操作,但存在磁兼容性差、体积大和控制困难等问题。为此,提出了一种基于球铰和丝杆螺母机构的磁兼容远程介入驱动器。
Measurement the viscoelastic properties is important for studying the developmental and pathological behavior of soft biological tissues. Magnetic resonance elastography (MRE) is a non-invasive method for in vivo measurement of tissue viscoelasticity. As a flexible method capable of testing small samples, indentation has been widely used for characterizing soft tissues. Using 2nd-order Prony series and dimensional analysis, we analyzed and compared the model parameters estimated from both indentation and MRE. Conversions of the model parameters estimated from the two methods were established. We found that the indention test is better at capturing the dynamic response of tissues at a frequency less than 10 Hz, while MRE is better for describing the frequency responses at a relatively higher range. The results provided helpful information for testing soft tissues using indentation and MRE. The models analyzed are also helpful for quantifying the frequency response of viscoelastic tissues. Graphic Abstract
Our goal is to design, test and verify an electromagnetic actuator for brain magnetic resonance elastography (MRE). We proposed a grappler-shaped design that can transmit stable vibrations into the brain. To validate its performance, simulations were carried out to ensure the electromagnetic field generated by the actuator did not interfere with the B0 field. The actuation vibration spectrum was analyzed to verify the actuation accuracy. Phantom and volunteer experiments were carried out to evaluate the performance of the actuator. Simulation of the magnetic field showed that the proposed actuator has a fringe field of less than 3 G in the imaging region. The phantom experiments showed that the proposed actuator did not interfere with the routine imaging sequences. The measured vibration spectra demonstrated that the frequency offset was about one third that of a pneumatic device and the transmission efficiency was three times higher. The shear moduli estimated from brain MRE were consistent with those from the literature. The actuation frequency of the proposed actuator has less frequency offset and off-center frequency components compared with the pneumatic counterpart. The whole actuator weighted only 980 g. The actuator can carry out multifrequency MRE on the brain with high accuracy. It is easy to use, comfortable for the patient and portable.