This article investigates electron bunch density fluctuations in the 1-10 mu m wavelength range, focusing on their impact on coherent electron cooling (CEC) in hadron storage rings. In this study, we compare the shot-noise model with experimental observations using bandwidth-filtered near-infrared optical transition radiation (OTR) photodiode signals, where the transverse bunch size is much larger than the OTR wavelength of interest. The relativistic electron bunch (gamma approximate to 50) parameters are close to those proposed for the coherent electron cooler in the electron-ion collider (EIC) project. Preliminary feasibility experiments were conducted, and the noise factors are presented, supported by particle tracking. No major density fluctuations or effective cooling rate decrease were revealed for EIC CEC design parameters. Additionally, longitudinal-space-charge-induced microbunching for the chicane-compressed bunch was observed with coherent OTR enhancements up to 100 times, providing further calibration of the measurement method.
Plasma wakefield accelerators use tabletop equipment to produce relativistic femtosecond electron bunches. Optical and X-ray diagnostics have established that their charge concentrates within a micrometre-sized volume, but its sub-micrometre internal distribution, which critically influences gain in free-electron lasers or particle yield in colliders, has proven elusive to characterize. Here, by simultaneously imaging different wavelengths of coherent optical transition radiation that a laser-wakefield-accelerated electron bunch generates when exiting a metal foil, we reveal the structure of the coherently radiating component of bunch charge. The key features of the images are shown to uniquely correlate with how plasma electrons injected into the wake: by a plasma-density discontinuity, by ionizing high-Z gas-target dopants or by uncontrolled laser-plasma dynamics. With additional input from the electron spectra, spatially averaged coherent optical transition radiation spectra and particle-in-cell simulations, we reconstruct coherent three-dimensional charge structures. The results demonstrate an essential metrology for next-generation compact X-ray free-electron lasers driven by plasma-based accelerators. Imaging the visible light emitted from accelerated electron bunches reveals important information about the three-dimensional charge structure of the bunches, which strongly influences the performance of free-electron lasers.
The Linac Extension Area has been developed into a beamline area for testing accelerator components and techniques. Beginning commissioning activities in February 2023, we have delivered the first electron beam to the Linac Extension Area at the Advanced Photon Source at 425 MeV. In the present work, we summarise the principal accelerator components and review safety controls of the Linac Extension Area.
Abstract Plasma wakefield accelerators use tabletop equipment to produce relativistic femtosecond electron bunches. Optical and x-ray diagnostics have established that their charge concentrates within a micrometer-sized volume, but its sub-micrometer internal distribution, which critically influences gain in free-electron lasers or particle yield in colliders, has proven elusive to characterize. Here, by simultaneously imaging different wavelengths of coherent optical transition radiation (COTR) that a laser-wakefield-accelerated e-bunch generated when exiting a metal foil, we elucidated the structure of the coherently-radiating component of bunch charge. Key features of the images correlated uniquely with how plasma electrons injected into the wake: by a plasma-density discontinuity, by ionising high-Z gas-target dopants, or by uncontrolled laser-plasma dynamics. With additional input from electron spectra, spatially-averaged COTR spectra, and particle-in-cell simulations, we reconstructed coherent 3D charge structures. The results demonstrate essential metrology for next-generation X-ray free-electron lasers.
The Fermilab Accelerator Science and Technology facility is currently in operation with its linac based on TESLA-type superconducting rf cavities. Using a 3-MHz micropulse repetition rate with a long macropulse composed of up to 3000 micropulses, and with beam energies demonstrated at 300 MeV and projected to reach 800 MeV with two additional cryomodules, the feasibilities for a vacuum ultraviolet (VUV) and an extreme ultraviolet (EUV) free-electron laser oscillator (FELO) with the two energies are evaluated. We have used both the GINGER code with an oscillator module and the MINERVA/OPC code to assess FELO saturation prospects at 120 nm with a 5.0-cm-period undulator of 4.5-m length and the MINERVA/OPC code to assess the FELO at 13.4 nm with adjusted parameters. The simulation results support saturation at both of these wavelengths which are much shorter than the demonstrated shortest wavelength record of 168.6 nm from a storage-ring-based FELO. This indicates superconducting rf linac-driven FELOs can be extended into this VUV-EUV wavelength regime previously only reached with single-pass FEL configurations. In addition, emittance-dilution effects due to wakefields in the cavities and the resulting submacropulse centroid slew effects on FELO performance are addressed using MINERVA/OPC simulations for the first time.
The FAST beamline is the injector for the planned Gamma-Ray Electron ENhanced Source (GREENS) program, which aims to achieve the demonstration and first application of a high-efficiency, high-average-power free-electron laser at 515 nm. FAST-GREENS requires high 5D peak brightness; transverse normalized projected emittances of 3 mm-mrad and a peak current of 600 A are the minimum beam requirements for the FEL to reach the 10% efficiency goal. In this work, studies of the low-energy section of the FAST beamline are presented toward these ends, including preliminary measurements of beam compression and beam emittance. An effort toward developing a high-fidelity simulation model that could be later optimized for FAST-GREENS is presented.
Experiments were performed at the Fermilab Accelerator Science and Technology (FAST) facility to elucidate the effects of long-range wakefields (LRWs) in TESLA-type superconducting rf cavities. In particular, we investigated the higher-order modes (HOMs) generated in the eight cavities of a cryomodule (CM) due to off-axis steering with correctors located ~4 m upstream of the CM. We have observed correlated submacropulse centroid slews of a few-hundred microns and centroid oscillations at ~240 kHz in the rf BPM data after the CM. The entrance energy into the CM was 25 MeV, and the exit energy was 100 MeV with 125 pC/b and 400 pC/b in 50-bunch pulse trains. These experimental results were evaluated for machine learning training aspects which will be used to inform the commissioning plan for the Linac Coherent Light Source-II injector CM.
The Advanced Photon Source (APS) team is building a fourth-generation storage ring (4GSR), replacing the present double-bend achromat lattice with a multibend achromat system thereby allowing the production of ultrabright x-ray beams. The new lattice enables a 2-order-of-magnitude reduction in horizontal beam emittance and a factor of two increase in beam current. The result is an electron beam of very high energy and power densities. Initial predictions suggest many common ultrahigh-vacuum-compatible materials struck by the full-intensity electron beam will be damaged. Two experimental beam abort studies have been conducted on collimator test pieces in the present APS SR to inform the design of a fully-functional machine protection system for APS 4GSR operations at 200 mA. A comprehensive suite of diagnostics was utilized during the studies. The diagnostics used in these experiments are not new, but employed in different ways to obtain unique data sets. With these sets now in hand, we are developing new numerical tools to guide collimator design using pelegant [M. Borland, elegant: A flexible SDDS-compliant code for accelerator simulation, Technical Report No. LS-287, Advanced Photon Source, 2000; Y. Wang and M. Borland, Implementation and performance of parallelized elegant, in Proceedings of the 2007 Particle Accelerator Conference, http://cern.ch/AccelConf/p07/PAPERS/THPAN095.PDF, pp. 3444--3446], mars [N. V. Mokhov and S. I. Striganov, Fermilab-conf-07/008-ad, AIP Conf. Proc. 896, 50 (2007)], and flash [B. Fryxell et al., flash: An adaptive mesh hydrodynamics code for modeling astrophysical thermonuclear flashes, Astrophys. J. Suppl. Ser. 131, 273 (2000); P. Tzeferacos et al., Laboratory evidence of dynamo amplification of magnetic fields in a turbulent plasma, Nat. Commun. 9, 591 (2018)].
The effects on beam dynamics from long-range and short-range wakefields from TESLA-type cavities are considered in regard to a proposed FEL oscillator (FE-LO) operating at 120 nm. This would be driven by the Fermilab Accelerator Science and Technology (FAST) linac at 300 MeV with a 3-MHz micropulse repetition rate. Our wakefield studies showed measurable effects on submacropulse centroid stability and on submicropulse head-tail kicks that can lead to emittance degradation. In the case of the former, we use MINERVA/OPC to simulate the ~100-$\mu$m centroid slew effects on the saturated output power levels of the FELO.
In this paper we discuss the design choices and construction strategy of the tapered undulator system designed for a high energy extraction efficiency experiment in the ultraviolet region of the electromagnetic spectrum planned for installation at the Argonne National Laboratory Linac Extension Area (LEA) beamline. The undulator is comprised of 4 sections pure permanent magnet Halbach array separated by short break sections, each one of them housing a focusing quadrupole doublet and a phase shifter. The quadrupoles use a novel hybrid design which allows one to vary the gradient and match the beam transversely. The undulator tapering profile is optimized to maximize the energy conversion efficiency from a 343 MeV 1 kA beam into coherent 257.5 nm radiation taking into account the longitudinal current profile generated by the linac.
2-ps temporal resolution). Steering off axis before CC1, resulted in a 100-kHz bunch centroid oscillation within the macropulse that was detected by the downstream rf BPMs and the streak camera*. At 500 pC/b, 50b, and 4-mrad off-axis vertical steering into CC2, we observed an ~ 100-micron head -tail centroid shift in the streak camera image y(t) profiles which we attributed to a short-range wakefield effect. Additional results for kick-angle compensations and model results will be presented.
The Fermilab Integrable Optics Test Accelerator (IOTA) ring optical stochastic cooling (OSC) experiment is designed for a low nominal beam current (~0.1 microAmps of 100-MeV electrons) to reduce intrabeam scattering (IBS), and during cooling, OSC is expected to reduce the bunch length from ~200 ps to ~130 ps. These equilibrium bunch lengths can be measured using a streak camera and the optical synchrotron radiation (OSR) generated in a ring dipole by the circulating beam as demonstrated on a small ring elsewhere recently. The same model streak camera has been installed on IOTA, and one expects the integrated sys-tem will have sufficient sensitivity and resolution for measuring the evolution and equilibrium values of the bunch length during OSC experiments.
Observations of optical synchrotron radiation emitted over millions of passes from a few electrons circulating in the particle accumulator ring at the Advanced Photon Source were performed with a digital CMOS camera and a synchroscan streak camera operating at 117.3 MHz. Discrete changes of integrated counts in the CMOS image region of interest are ascribed to single electron steps in a 10-s sensor integration time. Circulations of a single electron at 375 and at 425 MeV were demonstrated in the 12-bit digital CMOS camera images. The streak camera operating at the 12th harmonic of the fundamental revolution frequency at 9.77 MHz was used to measure the bunch length from 0.5-nC circulating charge down to tens of electrons or <10 aC. The measurements were performed with -8-ps temporal resolution uniquely at such ultralow charges. These results also serve as a proof-of-principle longitudinal profile diagnostic for the predicted effects of optical stochastic cooling at low charge in commissioning experiments at the Fermilab Integrable Optics Test Accelerator ring.
Laser plasma accelerators produce ultra-short, low emittance electron bunches that show potential for use in multistage colliders or for seeding free electron lasers. However, to optimize these novel accelerators for such applications, new diagnostics for micron-scale beams must be developed. In this paper we present single shot coherent optical transition radiation diagnostics that measure spatial and momentum distributions of microbunched high energy electron populations at the exit of a laser plasma accelerator. We show correspondence between the measured position and momentum of the electron beamlets as well as transverse distribution reconstructions of the coherent portion of the beam on a single shot at a variety of wavelengths. Finally, we propose a scheme for a full three-dimensional reconstruction of an electron bunch through coherent transition radiation analysis.
Higher-order modes (HOMs) in superconducting rf cavities present problems for an electron bunch traversing the cavity in the form of long-range wakefields from previous bunches. These may dilute the emittance of the macropulse average, especially with low emittance beams at facilities such as the European X-ray Free-electron Laser (XFEL) and the upgraded Linac Coherent Light Source (LCLS-II). Here we present observations of HOMs driven by the beam at the Fermilab Accelerator Science and Technology (FAST) facility. The FAST facility features two independent TESLA-type cavities (CC1 and CC2) after a photocath-ode rf gun followed by an 8-cavity cryomodule. The HOM signals were acquired from cavities using bandpass filters of 1.75 ± 0.15 GHz, 2.5 ± 0.2 GHz, and 3.25 ± 0.2 GHz and recorded using an 8-GHz, 20 GSa/s oscilloscope. The frequency resolution obtained is sufficient to separate polarization components of many of the HOMs. These HOM signals were captured from CC1 and cavities 1 and 8 of the cryomodule for various initial trajectories through the cavities, and we observe correlations between trajectory, HOM signals, and which polarization component of a mode is affected.
Experiments at the Fermilab Accelerator Science and Technology (FAST) facility detected electron beam-induced high order mode (HOM) signals from Tesla superconducting cavities. This paper describes some of the signal detection hardware used in this experiment, as well as measurements of the HOM signal magnitude versus beam trajectory. These measurements were made both with a single bunch and with a train of 50 bunches at bunch charges from 400 pC/b down to 10 pC/b. The detection hardware is designed for use with the Tesla superconducting cavities of LCLS-II at SLAC and is based on a prototype already in use at Fermilab. The HOM signal passes through a band-pass filter that is centered on several cavity dipole modes and a zero bias Schottky diode detects its magnitude. Direct comparisons were made between the FNAL chassis and the SLAC prototype for identical beam steering conditions. To support measurements with bunch charges as low as 10 pC, the SLAC detector has RF amplification between the band-pass filter and the diode detector. With this hardware, usable HOM signal measurements are obtained with a single bunch of 10 pC in cryomodule cavities as will be needed for LCLS-II.
Low emittance electron beams are of high importance at facilities like the Linac Coherent Light Source II (LCLS-II) at SLAC. Emittance dilution effects due to off-axis beam transport for a TESLA-type cryomodule (CM) have been shown at the Fermilab Accelerator Science and Technology (FAST) facility. The results showed the correlation between the electron beam-induced cavity high-order modes (HOMs) and bunch-by-bunch centroid slewing and oscillation down-stream of the CM. Mitigation of emittance dilution can be achieved by reducing the HOM signals and the standard deviation in the bunch-by-bunch beam positions downstream of the CM. Here we present a Machine Learning (ML) based optimization and model construction for HOM signal level reduction using Neural Networks (NN). To gather training data we performed experiments using 50 bunch electron beams with charges up to 600 pC/b. We measured HOM signals of all cavities and beam position with a set of BPMs downstream of the CM. The beam trajectory was changed using V/H125 corrector set located upstream of the CM. The preliminary results presented here will inform the LCLS-II injector commissioning and will serve as a prototype for HOM reduction and emittance preservation.