We show that chronic impairment of mitochondrial respiration is associated with marked accumulation of cytochrome c (Cytc) protein. Using SCO2-deficient HCT116 cells lacking functional cytochrome c oxidase and wild-type cells exposed to sustained hypoxia, we found that substantial mitochondrial Cytc accumulation parallels reduced electron flux through Cytc. SCO2-deficient cells exhibited equally elevated Cytc levels under normoxia (19% O2) and hypoxia (0.1-3% O2). Wild-type cells under sustained hypoxia accumulated Cytc, reaching levels comparable to those in SCO2-deficient cells. This effect was reversible upon reoxygenation. Increased Cytc protein levels were also observed in other cell models, including primary cortical neurons cultured under chronic hypoxia and in cerebral cortex tissue from hypoxia-exposed mice. Cytc accumulation occurred independently of CYCS transcription, mRNA translation, HIF activation, ROS production and changes in mitochondrial network. Pharmacological inhibition of complex III was likewise accompanied by increased Cytc levels, whereas mitochondrial uncoupling had no effect, suggesting that impaired electron transfer rather than membrane depolarisation per se underlies this association. Raman spectroscopy revealed enrichment of reduced Cytc and an increased Cytc-to-cytochrome b ratio in respiration-deficient cells. Further supporting a stabilisation-based mechanism, the fraction of membrane-unbound ferro-Cytc was decreased in SCO2-deficient cells, consistent with moderate cardiolipin enrichment, which is known to enhance retention of Cytc at the inner mitochondrial membrane. Despite elevated mitochondrial Cytc content, SCO2-deficient cells were less susceptible to apoptosis induced by intermittent hypoxia or dichloroacetate. Together, these findings indicate that reduced electron flux through complex IV is associated with Cytc accumulation through increased protein stability and membrane retention without enhancing apoptotic sensitivity.
Culturing cells and micro-tissue samples in 3D bio-scaffolding structures is gaining popularity; however, precise control of tissue micro-environment in such systems remains challenging. We describe a family of new hybrid bio-scaffolds with 3D O2-sensing ability, produced by simple means from readily available bio-scaffolding and O2-sensing materials. Three different types of phosphorescent O2-sensing materials-polymeric microparticles (MPs), supramolecular probe MitoXpress and nanoparticulate probes NanO2 and Nano-IR (NPs)-were integrated in Matrigel and agarose scaffolding materials and evaluated. Key working characteristics of such hybrid scaffolds, including heterogeneity, stability, cytotoxicity, optical signals and O2-sensing properties, ease of fabrication and use, were compared. The results show superiority of the Matrigel hybrids with NanO2 and Nano-IR probes. Demonstration experiments were conducted with HCT116 cells and individual spheroids derived from these cells, culturing them in the Matrigel-NP hybrid scaffolds and monitoring oxygenation and local O2 gradients on a time-resolved fluorescence plate reader and by phosphorescence lifetime imaging microscopy (PLIM).
The mood stabilizers lithium and valproate are psychotropic medications widely used in clinical practice. Despite their proven benefits, many individuals stop their treatment due to the adverse effects. Chronic diarrhoea is a common reason for discontinuation of these drugs; however, the underlying mechanisms are unknown. Excessive loss of bile acids (BA) into the colon is a major cause of diarrhoea. Therefore, we aimed to investigate the effects of these drugs on BA metabolism. We measured BA levels in the liver, plasma and faeces of Sprague–Dawley rats treated with lithium or valproate for 4 weeks. Next, we analysed changes in the expression of genes and proteins involved in BA production and enterohepatic circulation. Lithium and valproate markedly increased BA levels across all body sites. This was accompanied by the up‐regulation of hepatic cytochrome P450 7A1 (Cyp7a1), the rate‐limiting enzyme in de novo BA synthesis. Under normal conditions, elevated levels of BAs suppress Cyp7a1 via activation of the hepatic farnesoid X receptor (Fxr)/small heterodimer partner (Shp) and intestinal Fxr/fibroblast growth factor 19 (Fgf19) pathways. This signalling was disrupted in both treatment groups. The Fxr‐mediated responses in the expression of Ntcp, Asbt, Ilbp and Ostα/β bile transporters were also affected by treatment. In conclusion, lithium and valproate disrupted farnesoid X receptor signalling at the hepatic and intestinal levels, inducing sustained overproduction of bile in rats. These findings provide novel insights into the peripheral effects of these drugs. Given that similar changes in bile circuits underlie the pathophysiology of primary BA diarrhoea in humans, this study suggests a potential mechanism behind chronic diarrhoea in patients undergoing lithium or valproate therapy.
A deep understanding of mammalian cell metabolism and bioenergetics, and their alterations in disease states, is essential for many areas including cell biology, medicine, pharmacology, drug development and biotechnology. New sensor based systems and applications have enabled major advancements in this field, and they continue to develop and spread rapidly. Here we review the current analytical systems for the assessment of cell metabolism that rely on optochemical O2, pH and CO2 sensors. We describe the main operational principles of the sensors, analytical readouts that report on the key metabolic pathways (mainly glycolysis, the OxPhos and TCA cycle), and the corresponding sensing formats and platforms for measuring fluxes of cellular glycolysis, the OxPhos and the TCA cycle. Exemplary metabolic assays performed on these sensing platforms are also provided, explaining the data they generate. Finally, merits and limitations of current sensor-based systems and applications are discussed, highlighting potential avenues of their further development.
Ribosome profiling is a powerful technique used to study gene expression on a transcriptome-wide scale. It involves sequencing of mRNA fragments protected by ribosomes from ribonuclease digestion. The initial steps commonly involve cell lysis followed by centrifugation and ribonuclease digestion. We find that centrifugation depletes 329 translated mRNAs in HEK293T cells. Many of these mRNAs encode cytoskeleton proteins. This suggests that the expression of a subset of mRNAs may be significantly underestimated in most ribosome profiling experiments. We show that omitting the centrifugation step after cell lysis can resolve this issue.
Monitoring of tissue O 2 is essential for cancer development and treatment, as hypoxic tumour regions develop resistance to radio- and chemotherapy. We describe a minimally invasive technique for the monitoring of tissue oxygenation in developing grafted tumours, which uses the new phosphorescence lifetime based Tpx3Cam imager. CT26 cells stained with a near-infrared emitting nanoparticulate O 2 probe NanO2-IR were injected into mice to produce grafted tumours with characteristic phosphorescence. The tumours were allowed to develop for 3, 7, 10 and 17 days, with O 2 imaging experiments performed on live and euthanised animals at different time points. Despite a marked trend towards decreased O 2 in dead animals, their tumour areas produced phosphorescence lifetime values between 44 and 47 µs, which corresponded to hypoxic tissue with 5–20 μM O 2 . After the O 2 imaging in animals, confocal Phosphorescence Lifetime Imaging Microscopy was conducted to examine the distribution of NanO2-IR probe in the tumours, which were excised, fixed and sliced for the purpose. The probe remained visible as bright and discrete ‘islands’ embedded in the tumour tissue until day 17 of tumour growth. Overall, this O 2 macro-imaging method using NanO2-IR holds promise for long-term studies with grafted tumours in live animal models, providing quantitative 2D mapping of tissue O 2 .
Monitoring pH and extracellular acidification in biological samples containing live mammalian cells can provide valuable information on the glycolytic activity and bioenergetic status of cells. Compared to pH electrodes, optochemical pH sensors look more advantageous, since they allow rapid, non-invasive parallel analysis of multiple samples with stable readout of pH. We have developed new fluorescent pH sensors based on hydrophobic protonable metal-free porphyrins (OEP and OEPK) embedded in a proton-permeable polymeric matrix together with a proton transfer agent. These pH sensors provide internally-referenced calibration-free operation, both in ratiometric intensity and lifetime based detection modes. Sensor development included optimization of the indicator dye and its photophysical characteristics, screening of different proton transfer agents to minimize sensor toxicity, tuning of protonation range and pKa, long-term storage stability and response time studies. Optimised pH sensor coatings were then deposited on plastic substrates (96-well microplates) and used for real-time monitoring of Extracellular Acidification Rate (ECAR) for cultured cancer cells and 3D spheroid structures on standard laboratory equipment (multi-label plate reader and confocal FLIM microscope). The advanced pH sensors tailored for use with biological samples have high potential for cell analysis and related applications.
In this study, rapid respirometric microbial testing was combined with 16S rRNA amplicon sequencing, to assess the composition of microbiota in a total of 64 samples of commercial beef, turkey, lamb and pork mince. The O2 sensor-based respirometry system, while producing the anticipated total aerobic viable counts (TVC) data and patterns for most samples, also revealed unusual (linear) respiration profiles for some samples, mostly lamb and pork mince. The TVC values for beef mince, produced by respirometry and calculated using the available calibration equation, correlated well with the conventional plate counting method, ISO 4833-1:2013, 2013, while for the other species the correlation was less good. These effects, not observed in previous studies employing various food matrices, require further investigation. Using the same samples (crude homogenates) as in respirometry, the whole microbiome was also analysed by 16S rRNA amplicon sequencing for each mince-type. The sequencing showed an overall decrease in alpha diversity over shelf-life, with lamb and pork mince maintaining a proportion of rare taxa. Some taxa exhibited significant changes in abundance over shelf-life and after the respirometric analysis, with beef mince exhibiting a decrease in aerobic bacteria and an increase in facultative anaerobes. Beta diversity was also seen to depend on mince-type. Thus, the combined use of respirometry and sequencing techniques shows promise as a useful and unique analytical approach for food quality and safety evaluation, However, more data points and in-depth analysis are required to back up the findings of this initial study.
This paper presents a new photoluminescence lifetime imager designed to map the molecular oxygen (O2) concentration in different phosphorescent samples ranging from solid-state, O2-sensitive coatings to live animal tissue samples stained with soluble O2-sensitive probes. In particular, the nanoparticle-based near-infrared probe NanO2-IR, which is excitable with a 625 nm light-emitting diode (LED) and emits at 760 nm, was used. The imaging system is based on the Timepix3 camera (Tpx3Cam) and the opto-mechanical adaptor, which also houses an image intensifier. O2 phosphorescence lifetime imaging microscopy (PLIM) is commonly required for various studies, but current platforms have limitations in their accuracy, general flexibility, and usability. The system presented here is a fast and highly sensitive imager, which is built on an integrated optical sensor and readout chip module, Tpx3Cam. It is shown to produce high-intensity phosphorescence signals and stable lifetime values from surface-stained intestinal tissue samples or intraluminally stained fragments of the large intestine and allows the detailed mapping of tissue O2 levels in about 20 s or less. Initial experiments on the imaging of hypoxia in grafted tumors in unconscious animals are also presented. We also describe how the imager can be re-configured for use with O2-sensitive materials based on Pt-porphyrin dyes using a 390 nm LED for the excitation and a bandpass 650 nm filter for emission. Overall, the PLIM imager was found to produce accurate quantitative measurements of lifetime values for the probes used and respective two-dimensional maps of the O2 concentration. It is also useful for the metabolic imaging of ex vivo tissue models and live animals.
Using several types of Pt-porphyrin based oxygen sensing materials and conditions, we evaluated comparatively four different detection platforms that perform phosphorescence lifetime (PLT) measurements in the microsecond time domain. The time-resolved fluorescence reader Victor 2, which utilises Rapid Lifetime Determination method and Xe-flash lamp excitation, produced stable but inaccurate readings at PLT values <15 µs, affected by the flash-lamp afterglow and sensor heterogeneity in oxygenated conditions. The luminescence spectrometer Cary Eclipse, which utilises multi-point phosphorescence decay method, was able to partly correct these interfering factors and produce more accurate PLT values from mono- and bi-exponential fits, however short PLT values were still affected by Xe-flash lamp afterglow. The wide-field Tpx3Cam cam-era-based macroscope and the confocal laser-scanning FLIM/PLIM microscope, which use short-pulse excitation (ns LED or ps diode laser pulses, respectively) and TCSPC method, revealed the presence of short-lived components (1.5 – 6.0 µs) in sample decays, which have to be considered in PLT calculations. The imaging platforms produced more accurate and in-formative PLT data, but they operate with large volumes of raw and processed data. Overall, for each PLT platform a number of potential sources of error and measurement artefacts have been revealed, which can be minimised by careful optimisation of settings and validation with alternative platforms and sensor materials.
Cell analysis by optochemical sensing represents large and important niche in life and biomedical sciences. We present advanced multi-modal, multi-analyte sensing platform and dedicated materials for cell analysis based on the substituted phosphorescent Pt(II)- or Pd(II)-porphyrin indicator dyes bearing dual O2 and pH sensing functionality (MePor-SB). The study includes screening of the different host matrices for the sensor, synthesis and evaluation of new MePor-SB derivatives with altered protonation behaviour, development of the ratiometric version of the pH sensor, assessment of photoluminescent signal enhancement options, deposition of sensor coatings on common cell analysis substrates and their demonstration of sensor performance in Oxygen Consumption Rate (OCR) and Extracellular Acidification (ECA) measurements with relevant cell models. The main outcomes include the elaboration of the structure-function relationships for this biosensor system, development of the self-referenced tandem O2/pH and OCR/ECA sensing system which enables calibration-free operation, demonstration of the sensor operation on common plastic substrates in cell analysis, benchmarking against the existing platforms and real-life experiments with cells. This new sensing platform shows potential for wide practical use.
Activated ghrelin receptor GHS-R1α triggers cell signalling pathways that modulate energy homeostasis and biosynthetic processes. However, the effects of ghrelin on mRNA translation are unknown. Using various reporter assays, here we demonstrate a rapid elevation of protein synthesis in cells within 15–30 min upon stimulation of GHS-R1α by ghrelin. We further show that ghrelin-induced activation of translation is mediated, at least in part, through the de-phosphorylation (de-suppression) of elongation factor 2 (eEF2). The levels of eEF2 phosphorylation at Thr56 decrease due to the reduced activity of eEF2 kinase, which is inhibited via Ser366 phosphorylation by rpS6 kinases. Being stress-susceptible, the ghrelin-mediated decrease in eEF2 phosphorylation can be abolished by glucose deprivation and mitochondrial uncoupling. We believe that the observed burst of translation benefits rapid restocking of neuropeptides, which are released upon GHS-R1α activation, and represents the most time- and energy-efficient way of prompt recharging the orexigenic neuronal circuitry.
Mutations in genes encoding cytochrome c oxidase (mitochondrial complex IV) subunits and assembly factors [e.g., synthesis of cytochrome c oxidase 2 (SCO2)] are linked to severe metabolic syndromes. Notwithstanding that SCO2 is under transcriptional control of tumor suppressor p53, the role of mitochondrial complex IV dysfunction in cancer metabolism remains obscure. Herein, we demonstrate that the loss of SCO2 in HCT116 colorectal cancer cells leads to significant metabolic and signaling perturbations. Specifically, abrogation of SCO2 increased NAD(+) regenerating reactions and decreased glucose oxidation through citric acid cycle while enhancing pyruvate carboxylation. This was accompanied by a reduction in amino acid levels and the accumulation of lipid droplets. In addition, SCO2 loss resulted in hyperactivation of the insulin-like growth factor 1 receptor (IGF1R)/AKT axis with paradoxical downregulation of mTOR signaling, which was accompanied by increased AMP-activated kinase activity. Accordingly, abrogation of SCO2 expression appears to increase the sensitivity of cells to IGF1R and AKT, but not mTOR inhibitors. Finally, the loss of SCO2 was associated with reduced proliferation and enhanced migration of HCT116 cells. Collectively, herein we describe potential adaptive signaling and metabolic perturbations triggered by mitochondrial complex IV dysfunction.
Optochemical sensors are actively used in cell analysis, however existing systems have limitations with respect to their robustness and analytical performance. We have developed advanced multimodal and multi-parametric solid-state pH sensors for cell analysis based on hydrophobic protonable metal-free porphyrins, such as octaethylporphine (OEP), and octaethylporphine-ketone (OEPK), as fluorescent pH indicators. The internally referenced ratiometric intensity and nanosecond lifetime-based versions of the pH sensors were developed and also multiplexed with the O2 sensors based on phosphorescent PtOEP dye. We optimised the key parameters of the pH sensor, including: dye encapsulation matrix, the type and concentration of proton transfer reagent, measurement pH range and pKa, dye concentrations and cross-talk with the O2 sensor. Subsequently, sensor coatings were deposited on common substrates used in cell analysis (96-well plates), fine-tuned for their operational performance, dual O2/pH sensing functionally and the ability to measure Extracellular Acidification (ECAR) and Oxygen Consumption (OCR) rates in biological samples containing cells. The optimised sensors with stable internally referenced calibrations, convenient spectral characteristics and low cytotoxicity, were demonstrated with cultured cells and 3D spheroid structures, measuring their ECAR, OCR and responses to stimulation. These pH and dual pH/O2 sensors are well-suited for detailed metabolic studies of biological samples on widely available laboratory equipment.
Biological applications of phosphorescent probes for sensing molecular oxygen (O2) and bioimaging have gained popularity, but their choice is rather limited. We describe a family of new heterosubstituted phosphorescent bioprobes based on the Pt(II)-tetrakis(pentafluorophenyl)porphyrin (PtPFPP) dye. The probes are produced by simple click modification of its para- fluorine atoms with thiols, such as 1/2-thio-glucose, thio-poly(ethylene glycol) (PEG), or cysteamine. The probes were designed to have one cell-targeting moiety and three polar moieties forming a hydrophilic shell. Their chemical synthesis and purification were optimized to produce high reaction yields and easy scale-up. The ability to perform as cell-permeable or-impermeable probes was tuned by the polarity and molecular charge of the bioconjugate. The new PtPFPP derivatives were characterized for their spectral properties and cell-penetrating ability in the experiments with mammalian cell cultures, using a time-resolved fluorescence reader and PLIM imaging detection. Structure-activity relationships were established. Thus, the tri-and tetra-PEGylated structures showed low cell internalization allowing their use as extracellular probes, while cysteamine derivatives performed as efficient intracellular probes. No significant cytotoxicity was observed for all of the probes under the experimental conditions used.
BackgroundThe role of the gut microbiome in the biotransformation of drugs has recently come under scrutiny. It remains unclear whether the gut microbiome directly influences the extent of drug absorbed after oral administration and thus potentially alters clinical pharmacokinetics.MethodsIn this study, we evaluated whether changes in the gut microbiota of male Sprague Dawley rats, as a result of either antibiotic or probiotic administration, influenced the oral bioavailability of two commonly prescribed antipsychotics, olanzapine and risperidone.FindingsThe bioavailability of olanzapine, was significantly increased (1.8-fold) in rats that had undergone antibiotic-induced depletion of gut microbiota, whereas the bioavailability of risperidone was unchanged. There was no direct effect of microbiota depletion on the expression of major CYP450 enzymes involved in the metabolism of either drug. However, the expression of UGT1A3 in the duodenum was significantly downregulated. The reduction in faecal enzymatic activity, observed during and after antibiotic administration, did not alter the ex vivo metabolism of olanzapine or risperidone. The relative abundance of Alistipes significantly correlated with the AUC of olanzapine but not risperidone.InterpretationAlistipes may play a role in the observed alterations in olanzapine pharmacokinetics. The gut microbiome might be an important variable determining the systemic bioavailability of orally administered olanzapine. Additional research exploring the potential implication of the gut microbiota on the clinical pharmacokinetics of olanzapine in humans is warranted.FundingThis research is supported by APC Microbiome Ireland, a research centre funded by Science Foundation Ireland (SFI), through the Irish Government's National Development Plan (grant no. 12/RC/2273 P2) and by Nature Research-Yakult (The Global Grants for Gut Health; Ref No. 626891).
Specific bioenergetic signature reports on the current metabolic state of the cell, which may be affected by metabolic rearrangement, dysfunction or dysregulation of relevant signaling pathways, altered physiological condition or energy stress. A combined analysis of respiration , glycolytic flux, Krebs cycle activity, ATP levels, and total biomass allows informative initial assessment. Such simple, high-throughput, multiparametric methodology, called cell energy budget (CEB ) platform, is presented here and demonstrated with particular cell and tissue models. The CEB uses a commercial fluorescent lanthanide probe pH-Xtra™ to measure extracellular acidification (ECA) associated with lactate (L-ECA) and combined lactate/CO2 (T-ECA), a phosphorescent probe MitoXpress®-Xtra to measure oxygen consumption rate (OCR), a bioluminescent ATP kit, and an absorbance-based total protein assay. All the assays are performed on a standard multi-label reader. Using the same readouts, the CEB approach can be extended to more detailed mechanistic studies, by targeting specific pathways in cell bioenergetics and measuring other cellular parameters, such as NAD(P)H, Ca2+, mitochondrial pH, membrane potential, redox state, with conventional fluorescent or luminescent probes.
Identification of tumour margins during resection of the brain is critical for improving the post-operative outcomes. Current methods of tumour identification use 5-ALA, an exogenous precursor, metabolized to fluorescent PpIX in tumour tissue. Although visible under fluorescent microscope, PpIX is easily photo-bleached and tumour tagging is subjective, resulting in tumour under-resection and accelerated recurrence. To address this issue, photo-bleaching resistant and quantitative method is required. This study describes the characterization of a pulsed, multi-wavelengths system designed to measure diffuse reflectance and auto-fluorescence under strong ambient illumination conditions. The performance was tested on n = 400 liquid tissue phantoms containing a wide concentration range of absorber, scatterer and two fluorophores as well as on ex-vivo samples of gray and white matter. The background subtraction technique was shown to be efficient for a range of ambient illumination intensities. A linear relationship was observed between system response and predicted fluorophore concentrations as well as 97.8% accuracy of tissue classification by 5-fold cross-correlation, linear SVM.
While near-cognate codons are frequently used for translation initiation in eukaryotes, their efficiencies are usually low (<10% compared to an AUG in optimal context). Here, we describe a rare case of highly efficient near-cognate initiation. A CUG triplet located in the 5' leader of POLG messenger RNA (mRNA) initiates almost as efficiently (∼60 to 70%) as an AUG in optimal context. This CUG directs translation of a conserved 260-triplet-long overlapping open reading frame (ORF), which we call POLGARF (POLG Alternative Reading Frame). Translation of a short upstream ORF 5' of this CUG governs the ratio between POLG (the catalytic subunit of mitochondrial DNA polymerase) and POLGARF synthesized from a single POLG mRNA. Functional investigation of POLGARF suggests a role in extracellular signaling. While unprocessed POLGARF localizes to the nucleoli together with its interacting partner C1QBP, serum stimulation results in rapid cleavage and secretion of a POLGARF C-terminal fragment. Phylogenetic analysis shows that POLGARF evolved ∼160 million y ago due to a mammalian-wide interspersed repeat (MIR) transposition into the 5' leader sequence of the mammalian POLG gene, which became fixed in placental mammals. This discovery of POLGARF unveils a previously undescribed mechanism of de novo protein-coding gene evolution.
The recently designed Tpx3Cam camera based PLIM (Phosphorescence Lifetime IMaging) macro-imager was tested using an array of phosphorescent chemical and biological samples. A series of sensor materials prepared by incorporating the phosphorescent O2-sensitive dye, PtBP, into five polymers with different O2 permeability were imaged along with several commercial and non-commercial sensors based on PtBP and PtOEPK dyes. The PLIM images showed good lifetime contrast between the different materials, and phosphorescence lifetime values obtained were consistent with those measured by alternative methods. A panel of live tissues samples stained with PtBP based nanoparticle probe were also prepared and imaged under resting conditions and upon inhibition of respiration. The macro-imager showed promising results as a tool for PLIM of O2 in chemical and biological samples.